Catalog 1308242 Issued 3-03 OEG OMI 2 Pole series 2 Pole Miniature Power PC Board Relay Appliances, HVAC, Office Machines. UL File No. E58304 CSA File No. LR48471 VDE File No. 6678 SEMKO File No. 9517235 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Features Coil Data @ 20C * Meet UL 508, VDE0435 and SEMKO requirements. * 2 Form A and 2 Form C contact arrangements. * Immersion cleanable, sealed version available. * Meet 5,000V dielectric voltage between coil and contacts. * Meet 10,000V surge voltage between coil and contacts (1.2 / 50s). Rated Coil Voltage (VDC) Nominal Current (mA) Coil Resistance (ohms) 10% 5 6 9 12 24 48 106.4 88.0 58.0 44.4 21.8 10.9 47 68 155 270 1,100 4,400 Rated Coil Voltage (VDC) Nominal Current (mA) 5 6 9 12 24 48 138.9 120.0 78.3 60.0 29.3 14.5 Contact Data @ 20C Arrangements: 2 Form A (DPST-NO) and 2 Form C (DPDT). Material: Ag Alloy. Max. Switching Rate: 300 ops./min. (no load). 30 ops./min. (rated load). Expected Mechanical Life: 10 million operations (no load). Expected Electrical Life: 100,000 operations (rated load). Minimum Load: 100mA @ 5VDC. Initial Contact Resistance: 100 milliohms @ 1A, 6VDC. Contact Ratings Ratings: 5A @ 240VAC resistive, 5A @ 120VAC resistive, 5A @ 30VDC resistive, 1/8 HP @ 250VAC. OMI-L Sensitive Must Operate Voltage (VDC) Must Release Voltage (VDC) 4.00 4.80 7.20 9.60 19.20 38.40 0.50 0.60 0.90 1.20 2.40 4.80 Coil Resistance (ohms) 10% Must Operate Voltage (VDC) Must Release Voltage (VDC) 36 50 115 200 820 3,300 3.75 4.50 6.75 9.00 18.00 36.00 0.50 0.60 0.90 1.20 2.40 4.80 OMI-D Standard Operate Data 1.5A @ 240VAC inductive (coso= 0.4), 1.5A @ 120VAC inductive (coso= 0.4), 1.5A @ 24VDC inductive (L/R=7msec). Max. Switched Voltage: AC: 240V. DC: 30V. Max. Switched Current: 5A. Max. Switched Power: OMI: 1,200VA, 150W. Must Operate Voltage: OMI-D: 75% of nominal voltage or less. OMI-L: 80 % of nominal voltage or less. Must Release Voltage: 5% of nominal voltage or more. Operate Time: OMI-D: 15 ms max. OMI-L: 20 ms max. Release Time: 8 ms max. Environmental Data Between Mutually Insulated Elements: 1,000M ohms min. @ 500VDCM. Temperature Range: Operating: OMI-D: -30C to +55C OMI-L: -30C to +70 C Vibration, Mechanical: 10 to 55 Hz., 1.5mm double amplitude Operational: 10 to 55 Hz., 1.5mm double amplitude. Shock, Mechanical: 1,000m/s2 (100G approximately). Operational: 100m/s2 (10G approximately). Operating Humidity: 20 to 85% RH. (Non-condensing). Coil Data Mechanical Data Voltage: 5 to 48VDC. Nominal Power: 720mW (OMI-D), 540mW (OMI-L). Coil Temperature Rise: 45C max., at rated coil voltage. Max. Coil Power: 130% of nominal. Duty Cycle: Continuous. Termination: Printed circuit terminals. Enclosure (94V-0 Flammability Ratings): OMI-SS: Vented (Flux-tight) plastic cover. OMI-SH: Sealed plastic case. Weight: 0.46 oz (13g) approximately. Initial Dielectric Strength Between Open Contacts: 1,000VAC 50/60 Hz. (1 minute). Between Coil and Contacts: 5,000VAC 50/60 Hz. (1 minute). Surge Voltage Between Coil and Contacts: 10,000V (1.2 / 50s). Initial Insulation Resistance Dimensions are shown for 460 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 Ordering Information Typical Part Number OEG B OMI -SS -2 12 L M ,594 1. Basic Series: OMI = 2 Pole Miniature Power PC Board Relay. 2. Enclosure: SS = Vent (Flux-tight)* plastic cover. SH = Sealed, plastic case. 3. Termination: 2 = 2 pole 4. Coil Voltage: 05 = 5VDC 06 = 6VDC 09 = 9VDC 12 = 12VDC 24 = 24VDC 48 = 48VDC 5. Coil Input: D = Standard (720mW) L = Sensitive (540mW) 6. Contact Arrangement: Blank = 2 Form C, DPDT M = 2 Form A, DPST-NO 7. Suffix: ,500 = Standard model for "SS" enclosure ,594 = Standard model for "SH" enclosure Other Suffix = Custom model * Not suitable for immersion cleaning processes. Our authorized distributors are more likely to stock the following items for immediate delivery. OMI-SH-205D,594 OMI-SH-212D,594 OMI-SH-224D,594 OMI-SH-205L,594 OMI-SH-212L,594 OMI-SH-224L,594 Wiring Diagram (Bottom View) Outline Dimensions .811 .02 (20.6 .5) .024 c (.60) .157 .012 (4.0 .3) .012 (.3) .012 (.3) 1.15 .02 (29.2 .5) .039 (1.0) .012 (.3) .100 .008 (2.55 .2) .30 .008 (7.6 .2) .2 (5.08) .6 (15.24) .039 (1.0) PC Board Layout (Bottom View) 6 - .059 DIA (1.5) .504 .02 (12.8 .5) .30 .004 (7.6 .1) 2 - .039 DIA (1.0) .144 (.067) .2 (5.08) .2 (5.08) .2 (5.08) .600 (15.24) Reference Data Operate Time 50 10 40 8 30 20 Life Expectancy 100 240VAC, 24VDC Resistive 4 12 Operation (x 10 ) 60 Time (msec) Temp. Rise (C) Coil Temperature Rise Operate Time 6 4 10 2 10 Release Time 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Coil Power (W) Dimensions are shown for reference purposes only. 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Coil Power (W) Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. 1 0 1 2 4 3 5 Contact Curr ent (A) www.tycoelectronics.com Technical support: 461 Refer to inside back cover.