Solid State Relays for Heaters G3PE-Single-phase CSM_G3PE-Single-phase_DS_E_2_1 Compact, Slim-profile SSRs with Heat Sinks. Models with No Zero Cross for a Wide Range of Applications. * RoHS compliant. * Models also available with no zero cross * Surge pass protection improved surge dielectric strength for output currents. (OMRON testing) * Compact with a slim profile. * Mount to DIN Track or with screws. * Conforms to UL, CSA, and EN standards (TUV certification). Refer to Safety Precautions for All G3PE Models. Ordering Information List of Models Number of phases Insulation method Operation indicator Rated input voltage Zero cross function Applicable load * Model 15 A, 100 to 240 VAC G3PE-215B DC12-24 Yes 25 A, 100 to 240 VAC G3PE-225B DC12-24 35 A, 100 to 240 VAC G3PE-235B DC12-24 45 A, 100 to 240 VAC G3PE-245B DC12-24 15 A, 100 to 240 VAC G3PE-215BL DC12-24 No Single-phase Phototriac coupler Yes (yellow) 25 A, 100 to 240 VAC G3PE-225BL DC12-24 35 A, 100 to 240 VAC G3PE-235BL DC12-24 45 A, 100 to 240 VAC G3PE-245BL DC12-24 12 to 24 VDC 15 A, 200 to 480 VAC G3PE-515B DC12-24 Yes 25 A, 200 to 480 VAC G3PE-525B DC12-24 35 A, 200 to 480 VAC G3PE-535B DC12-24 45 A, 200 to 480 VAC G3PE-545B DC12-24 15 A, 200 to 480 VAC G3PE-515BL DC12-24 No 25 A, 200 to 480 VAC G3PE-525BL DC12-24 35 A, 200 to 480 VAC G3PE-535BL DC12-24 45 A, 200 to 480 VAC G3PE-545BL DC12-24 * The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 3. 1 G3PE-Single-phase Specifications Certification UL508, CSA22.2 No.14, and EN60947-4-3 Ratings Input (at an Ambient Temperature of 25C) Item G3PE-@@@B Operating voltage range Rated voltage Model 12 to 24 VDC G3PE-@@@BL 7 mA max. 9.6 to 30 VDC Voltage level Rated input current Must operate voltage 9.6 VDC max. 15 mA max. Must release voltage 1.0 VDC max. Output Model Item G3PE-215B(L) G3PE-225B(L) G3PE-235B(L) G3PE-245B(L) G3PE-515B(L) G3PE-525B(L) G3PE-535B(L) G3PE-545B(L) Rated load voltage 100 to 240 VAC (50/60 Hz) 200 to 480 VAC (50/60 Hz) Load voltage range 75 to 264 VAC (50/60 Hz) 180 to 528 VAC (50/60 Hz) Applicable load current 0.1 to 15 A (at 40C) 0.1 to 25 A (at 40C) Inrush current resistance 150 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) Permissible I2t (reference value) 121A2s 260A2s 3 kW (at 200 VAC) 5 kW (at 200 VAC) * Applicable load (resistive load) 0.5 to 35 A (at 25C) 0.1 to 15 A (at 40C) 0.1 to 25 A (at 40C) 440 A (60 Hz, 1 cycle) 150 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 1,260A2s 128A2s 7 kW (at 200 VAC) 0.5 to 45 A (at 25C) 9 kW (at 200 VAC) 6 kW (at 400 VAC) 0.5 to 35 A (at 25C) 0.5 to 45 A (at 25C) 440 A (60 Hz, 1 cycle) 1,350A2s 10 kW (at 400 VAC) 6,600A2s 14 kW (at 400 VAC) 18 kW (at 400 VAC) * The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 3. Characteristics Model Item G3PE -215B G3PE -225B G3PE -235B Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. G3PE -245B G3PE -215BL G3PE -225BL G3PE -235BL G3PE -245BL 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current 10 mA max. (at 200 VAC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 55 to10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) (Mounted to DIN track) Shock resistance Destruction: 294 m/s2 (Mounted to DIN track) Ambient storage temperature -30 to 100C (with no icing or condensation) Ambient operating temperature -30 to 80C (with no icing or condensation) Ambient operating humidity 45% to 85% Weight Approx. 240 g Model Item G3PE -515B Approx. 400 g G3PE -525B G3PE -535B Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Approx. 240 g G3PE -545B G3PE -515BL Approx. 400 g G3PE -525BL G3PE -535BL G3PE -545BL 1 ms max. Output ON voltage drop 1.8 V (RMS) max. Leakage current 20 mA max. (at 480 VAC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 55 to10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) (Mounted to DIN track) Shock resistance Destruction: 294 m/s2 (Mounted to DIN track) Ambient storage temperature -30 to 100C (with no icing or condensation) Ambient operating temperature -30 to 80C (with no icing or condensation) Ambient operating humidity 45% to 85% Weight Approx. 240 g Approx. 400 g Approx. 240 g Approx. 400 g 2 G3PE-Single-phase Engineering Data Input Voltage vs. Input Impedance and Input Voltage vs. Input Current 6 5 Input current 4 3 2 Input impedance 1 0 0 5 10 15 20 25 30 35 Input voltage (V) G3PE-5@@B Ta = 25C Input current Input current (mA) 7 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Input impedance (k) 8 Input current (mA) Ta = 25C 9 Input impedance (k) G3PE-2@@BL 10 Input current (mA) Input impedance (k) G3PE-2@@B 10 Ta = 25C 9 8 7 6 5 Input current 4 3 Input impedance 2 Input impedance 1 0 0 5 10 15 20 25 30 35 Input voltage (V) 0 5 10 15 20 25 30 35 Input voltage (V) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Input current (mA) Input impedance (k) G3PE-5@@BL Ta = 25C Input current Input impedance 0 5 10 15 20 25 30 35 Input voltage (V) Load Current vs. Ambient Temperature G3PE-235B(L), G3PE-245B(L) G3PE-535B(L), G3PE-545B(L) 30 Load current (A) Load current (A) G3PE-215B(L), G3PE-225B(L) G3PE-515B(L), G3PE-525B(L) 25 G3PE-225B(L) G3PE-525B(L) 20 50 G3PE-245B(L) G3PE-545B(L) 45 40 G3PE-235B(L) 35 30 15 G3PE-215B(L) G3PE-515B(L) 7 0 -30 G3PE-535B(L) 20 18 17 14 10 10 -20 0 20 0 -30 40 60 80 100 Ambient temperature (C) -20 0 20 25 40 60 80 100 Ambient temperature (C) Inrush Current Resistance: Non-repetitive Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively. 250 200 150 G3PE-235B(L), G3PE-245B(L) G3PE-535B(L), G3PE-545B(L) Inrush current (A. Peak) G3PE-225B(L), G3PE-525B(L) Inrush current (A. Peak) Inrush current (A. Peak) G3PE-215B(L), G3PE-515B(L) 250 200 150 500 400 300 100 100 200 50 50 100 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) 3 G3PE-Single-phase Close Mounting (3 or 8 SSRs) 13 12 10 25 3 Relays 20 19 15 G3PE-235B(L) Load current (A) 3 Relays 15 30 8 Relays 40 3 Relays 30 28 26 G3PE-245B(L) Load current (A) G3PE-225B(L) 20 Load current (A) Load current (A) G3PE-215B(L) 8 Relays 20 0 Load current (A) 3 Relays 15 13 12 30 25 20 0 -40 20 40 60 80 100 Ambient temperature (C) G3PE-525B(L) 20 3 Relays 15 0 5.7 5 20 40 60 80 100 Ambient temperature (C) 0 -40 3 Relays 30 28 26 8 Relays 0 -20 0 20 25 40 60 80 100 Ambient temperature (C) G3PE-545B(L) 50 40 3 Relays 31 30 29 8 Relays 20 11 10 -20 0 -40 20 25 40 60 80 100 Ambient temperature (C) 40 20 10 7 6 5 0 -20 8 Relays 8 Relays -20 11 10 G3PE-535B(L) 17 16 10 0 -40 -20 Load current (A) G3PE-515B(L) Load current (A) 0 -40 20 40 60 80 100 Ambient temperature (C) 11 10 Load current (A) 5.7 5 0 3 Relays 31 30 29 20 10 8 7 5 -20 40 8 Relays 8 Relays 0 -40 50 20 40 60 80 100 Ambient temperature (C) 0 -40 11 10 -20 0 20 25 40 60 80 100 Ambient temperature (C) 0 -40 -20 0 20 25 40 60 80 100 Ambient temperature (C) Close Mounting Example DIN Track 4 G3PE-Single-phase Dimensions Note: All units are in millimeters unless otherwise indicated. Solid State Relays G3PE-215B(L) G3PE-225B(L) G3PE-515B(L) G3PE-525B(L) 130.2 Two, 4.6 dia. Two, M4 100 max. 900.2 24 68 84 Two, M3.5 4.6 x 5.6 elliptical hole 4.2 6.3 Note: Without terminal cover. 4.5 22.5 max. Note: With terminal cover. Mounting Holes Terminal Arrangement/Internal Circuit Diagram G3PE-5@@B G3PE-2@@B (+) 1 (+) 1 Input circuit Trigger circuit Output side A1 Input side (90) (85) Input circuit (100) 900.3 Trigger circuit Output side A1 A2 2 Three, 4.5 dia. or M4 G3PE-235B(L) G3PE-245B(L) G3PE-535B(L) G3PE-545B(L) 250.2 Input side 130.3 A2 2 )-( )-( 4.6 dia. Two, M5 100 max. 68 24 900.2 84 Two, M3.5 6 13.5 Note: Without terminal cover. 4.6 x 5.6 elliptical hole 44.5 max. Note: With terminal cover. Mounting Holes Terminal Arrangement/Internal Circuit Diagram 250.3 G3PE-5@@B G3PE-2@@B (+) 1 Input circuit Trigger circuit Output side A2 Three, 4.5 dia. or M4 2 )-( (+) A1 Input side (90) Input circuit (85) Trigger circuit (100) 900.3 Output side A1 Input side 1 A2 2 )-( 5 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2010.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2010 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: G3PE-515B DC12-24 G3PE-525B DC12-24 G3PE-535B DC12-24 G3PE-545B DC12-24 G3PE-215BL DC12-24 G3PE-225BL DC12-24 G3PE-235BL DC12-24 G3PE-245BL DC12-24 G3PE-515BL DC12-24 G3PE-525BL DC12-24 G3PE-535BL DC12-24 G3PE-545BL DC12-24