For more Information
please call
1-800-Belden1
General Description:
22 AWG stranded (7x30) TC conductor, Datalene® insulation, individually shielded with Beldfoil® (100%
coverage), numbered/color-coded PVC jackets, pair jackets and shields bonded so both strip
simultaneously with automatic stripping equipment.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (in.)
622 7x30 TC - Tinned Copper .030
Total Number of Conductors: 12
Insulation
Insulation Material:
Insulation Trade Name Insulation Material Dia. (in.)
Datalene® FHDPE - Foam High Density Polyethylene 0.060
Inner Shield
Inner Shield Material:
Inner Shield Trade Name Type Inner Shield Material Coverage (%)
Beldfoil® Tape Aluminum Foil-Polyester Tape 100
Inner Shield Drain Wire AWG:
AWG
22
Inner Shield Drain Wire Stranding: 7x30
Inner Shield Drain Wire Conductor Material: TC - Tinned Copper
Inner Jacket
Inner Jacket Material:
Inner Jacket Material Nom. Dia. (in.)
PVC - Polyvinyl Chloride 0.153
Inner Jacket Color Code Chart:
Number Color
1Brown
2Red
3Orange
4Yellow
5Green
6Blue
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Outer Jacket Ripcord: Yes
Overall Cable
Overall Nominal Diameter: 0.578 in.
Pair
Pair Color Code Chart:
Color
Red & Black
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +60°C
Non-UL Temperature Rating: 60°C
Page 1 of 3 01-09-2015
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1218B Multi-Conductor - Flexible, Low-Capacitance Cable
Bulk Cable Weight: 148 lbs/1000 ft.
Max. Recommended Pulling Tension: 164 lbs.
Min. Bend Radius/Minor Axis: 5.750 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
70
Nom. Inductance:
Inductance (µH/ft)
.20
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
19
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
35
Nominal Velocity of Propagation:
VP (%)
78
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
15
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 10.600 Ohm/1000 ft
Max. Operating Voltage - Non-UL:
Voltage
150 V RMS
300 V RMS
Max. Recommended Current:
Current
2 Amps per conductor @ 20°C
Notes (Overall)
Notes: Datalene® insulation features include a low dielectric constant and a low dissipation factor for high-speed, low distortion data handling. Physical properties include good
crush resistance and light weight. Pair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
1218B B591000 1,000 FT 155.000 LB BLACK, MATTE C 6 PR #22 FHDPE FS PVC PVC
1218B B59500 500 FT 82.500 LB BLACK, MATTE C 6 PR #22 FHDPE FS PVC PVC
Notes:
C = CRATE REEL PUT-UP.
Page 2 of 3 01-09-2015
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1218B Multi-Conductor - Flexible, Low-Capacitance Cable
Revision Number: 2 Revision Date: 11-06-2014
© 2015 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 01-09-2015
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1218B Multi-Conductor - Flexible, Low-Capacitance Cable