1
G
6
B
G6B
PCB Power Relay
High Capacity and High
Dielectric Strength Miniature
Relay with Fully Sealed
Construction in 5 A (8 A)
SPST-NO(1a),
SPST-NO+SPST-NC(1a1b),
DPST-NO(2a),
DPST-NC(2b) Types
High sensitive with operating power of 98 mW.
(G6B-1114P-US and G6B-1174P-US models)
High insulation with dielectric strength of 3,000VAC
between coil and contacts (impulse withstand voltage of 6 kV).
Stick packing models are provided in consideration of compatibility to the automatic production line.
Standard model conforms to UL/CSA standards. Other SEV approved models are also available.
AgSnIn contacts suitable for loads that generate surge voltage (inductive load, capacity load, etc.) available. (-FD type)
Ultrasonic cleanable models available. (-U type)
Operation indicator & built-in surge absorption diode available. (-ND type)
2-Pole type available.
Model Number Legend
RoHS Compliant
Application Examples
Ideal for output applications of control equipments
12345678910
-G6B@-@@@@@-@-@-@-@-@
1. Relay Function
None: Single-side stable
U : Single-winding latching
(G6B@-1114 models only)
K : Double-winding latching
(G6B@-1114 models only)
2. Contact Form
21: SPST-NO + SPST-NC
22: DPST-NO
20: DPST-NC
11: SPST-NO
3. Classification
1: Standard
7: High-capacity
4. Enclosure rating
4: Fully sealed
7: Flux protection
5. Terminal Shape
P: PCB terminals
Socket mounting terminals
6. Contact material
None: Standard (Ag-alloy (Cd free))
FD : AgSnIn contact
(Suitable for DC inductive load with
high inrush current)
7. Operation Indicator Diode
Availability
None: Standard
ND : Operation indicator & coil surge
absorption diode
(for -1177 type only)
8. Approved Standards
US: UL/CSA
9. Washability
None: Standard
U : For ultrasonically cleanable
10.Mounting
None: Mounted directly to PCB
P6B : Mounted to Socket
2
G6B PCB Power Relay
G
6
B
Ordering Information
Standard Models (UL, CSA certified)
Note: AgSnIn contact models are highly welding-resistant, and roughening of contacts due to inrush current and inductive load is lessened.
Models for Ultrasonically Cleanable
Note: When ordering, add the rated coil voltage to the model number.
Example: G6B-1114P-US DC5
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
Connecting Sockets (Sold Separately)
Note 1. G6B-1174P-US-P6B and G6B-1177P-ND-US-P6B are rated for 8 A when mounted on a PCB. However,
when used with the P6B-04P socket models, the allowable current is derated to 5 A.
2. The P6B sockets are designed to be used with G6B-@@@@P(-FD)-US-P6B relays. Only use G6B relays
that include "-P6B" in their model numbers with the sockets. Do not use standard G6B's that omit "-P6B"
from their model numbers with the sockets.
3.The hold-down clips of the P6B-C2 model are not suitable for the G6B-1174P and G6B-1177P models
since they have different heights.
4.Products with UL/CSA certification marks will be supplied for orders of standard models.
Number
of poles
Contact material Standard (Ag-alloy (Cd free)) AgSnIn contact Minimum
packing unit
Relay Function Contact form Model Rated coil voltage Model Rated coil voltage
1-pole
Single-side stable
SPST-NO (1a)
(Standard) G6B-1114P-US 5, 6, 12, 24 VDC G6B-1114P-FD-US 5, 6, 12, 24 VDC 100
pcs/tray
SPST-NO (1a)
(High-capacity) G6B-1174P-US 5, 6, 12, 24 VDC G6B-1174P-FD-US 5, 6, 12, 24 VDC 20
pcs/tube
Single-winding
latching
SPST-NO (1a)
(Standard) G6BU-1114P-US 5, 6, 12, 24 VDC G6BU-1114P-FD-US 5, 12, 24 VDC 100
pcs/tray
Double-winding
latching
SPST-NO (1a)
(Standard) G6BK-1114P-US 5, 6, 12, 24 VDC G6BK-1114P-FD-US 5, 6, 12, 24 VDC
Single-side stable
SPST-NO (1a)
(Built-in high-capacity
operation indicator &
diode)
G6B-1177P-ND-US 5, 12, 24 VDC G6B-1177P-FD-ND-US 5, 12, 24 VDC 20
pcs/tube
2-pole Single-side stable
SPST-NO (1a)+
SPST-NC (1b) (Standard) G6B-2114P-US 5, 6, 12, 24 VDC G6B-2114P-FD-US 5, 6, 12, 24 VDC
100
pcs/tray
DPST-NO (2a)
(Standard) G6B-2214P-US 5, 6, 12, 24 VDC G6B-2214P-FD-US 5, 6, 12, 24 VDC
DPST-NC (2b)
(Standard) G6B-2014P-US 5, 6, 12, 24 VDC G6B-2014P-FD-US 5, 6, 12, 24 VDC
Number
of poles
Contact material Standard (Ag-alloy (CD free)) AgSnIn contact Minimum
packing unit
Relay Function Contact form Model Rated coil voltage Model Rated coil voltage
1-pole
Single-side stable SPST-NO (1a)
(Standard) G6B-1114P-US-U 5, 6, 12, 24 VDC G6B-1114P-FD-US-U 6, 12, 24 VDC
100
pcs/tray
Single-winding
latching
SPST-NO (1a)
(Standard) G6BU-1114P-US-U 24 VDC −−
Double-winding
latching
SPST-NO (1a)
(Standard) G6BK-1114P-US-U 5, 6, 12, 24 VDC G6BK-1114P-FD-US-U 12, 24 VDC
2-pole Single-side stable
SPST-NO (1a)+
SPST-NC (1b) (Standard) G6B-2114P-US-U 5, 12, 24 VDC G6B-2114P-FD-US-U 5, 12, 24 VDC
DPST-NO (2a)
(Standard) G6B-2214P-US-U 5, 6, 12, 24 VDC G6B-2214P-FD-US-U 5, 12, 24 VDC
DPST-NC (2b)
(Standard) G6B-2014P-US-U 5, 12, 24 VDC G6B-2014P-FD-US-U 5, 12, 24 VDC
Applicable relay Model Minimum ordering unit
G6B-1114P(-FD)-US-P6B
G6B-1174P(-FD)-US-P6B
G6B-1177P(-FD)-ND-US-P6B
G6BU-1114P-US-P6B
P6B-04P
20 pcs
G6BK-1114P-US-P6B P6B-06P
G6B-2114P-US-P6B
G6B-2214P-US-P6B
G6B-2014P-US-P6B
P6B-26P
Removal Tool P6B-Y1 1 pcs
Hold-down Clips P6B-C2
Rated coil voltage
3
G6B PCB Power Relay
G
6
B
Ratings
Coil: 1-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)
Coil: 2-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)
Coil: Single-winding Latching Type (Including models for ultrasonically cleanable)
Coil: Double-winding Latching Type (Including models for ultrasonically cleanable)
Coil: Operation Indicator Model (Flux-resistant type. Do not wash down with water.)
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.The operating characteristics are measured at a coil temperature of 23°C.
3.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Contacts
Note 1. The values in the parentheses ( ) are for -FD models only.
2.Use the -FD type for inductive load and switching load which contact roughening is small.
Item
Rated voltage
Rated current
(mA)
Coil resistance
(Ω)
Must operate
voltage (V)
Must release
voltage (V)
Max. voltage
(V) Power consumption
(mW)
% of rated voltage
5 VDC 40 125
70% max. 10% min. 160%
(at 23°C) Approx. 200
6 VDC 33.3 180
12 VDC 16.7 720
24 VDC 8.3 2,880
Item
Rated voltage
Rated current
(mA)
Coil resistance
(Ω)
Must operate
voltage (V)
Must release
voltage (V)
Max. voltage
(V) Power consumption
(mW)
% of rated voltage
5 VDC 60 83.3
80% max. 10% min. 140%
(at 23°C) Approx. 300
6 VDC 50 120
12 VDC 25 480
24 VDC 12.5 1,920
Item
Rated voltage
Rated
current
(mA)
Coil
resistance
(Ω)
Must set
voltage (V)
Must reset
voltage (V)
Max. voltage
(V) Power consumption
% of rated voltage Set coil
(mW)
Reset coil
(mW)
5 VDC 40 125
70% max. 70% max. 160%
(at 23°C) 200 200
6 VDC 33.3 180
12 VDC 16.7 720
24 VDC 8.3 2,880
Item
Rated voltage
Rated current (mA) Coil resistance (Ω)Must set voltage
(V)
Must reset voltage
(V)
Max. voltage
(V) Power consumption
Set coil Reset coil Set coil Reset coil % of rated voltage Set coil
(mW)
Reset coil
(mW)
5 VDC 56 56 89.2 89.2
70% max. 70% max. 130%
(at 23°C) 280 280
6 VDC 46.8 46.8 128.5 128.5
12 VDC 23.3 23.3 515 515
24 VDC 11.7 11.7 2,060 2,060
Item
Rated voltage
Rated current
(mA)
Coil resistance
(Ω)
Must operate
voltage (V)
Must release
voltage (V)
Max. voltage
(V) Power consumption
(mW)
% of rated voltage
5 VDC 43 116
70% max. 10% min. 130%
(at 23°C)
Approx. 200
12 VDC 19.7 610 Approx. 240
24 VDC 11.3 2,120 Approx. 275
Model
G6B-1114P-US
G6BU-1114P-US
G6BK-1114P-US
G6B-1114P-FD-US
G6BU-1114P-FD-US
G6BK-1114P-FD-US
G6B-1174P-US
G6B-1177P-ND-US
G6B-1174P-FD-US
G6B-1177P-FD-ND-US
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
G6B-2114P-FD-US
G6B-2214P-FD-US
G6B-2014P-FD-US
Load
Item
Resistive load Inductive load
(cos
φ
= 0.4; L/R = 7 ms) Resistive load Inductive load
(cos
φ
= 0.4; L/R = 7 ms) Resistive load Inductive load
(cos
φ
= 0.4; L/R = 7 ms)
Contact type Single
Contact material Ag-Alloy (Cd free)
Rated load
5 A (3 A) at 250 VAC
5 A (3 A) at 30 VDC
2 A (2 A) at 250 VAC
2 A (2 A) at 30 VDC
8 A (5 A) at 250 VAC
8 A (5 A) at 30 VDC
2 A (2 A) at 250 VAC
2 A (2 A) at 30 VDC
5 A (3 A) at 250 VAC
5 A (3 A) at 30 VDC
1.5 A (1.5 A) at 250 VAC
1.5 A (1.5 A) at 30 VDC
Rated carry current 5 A (5 A) 8 A (5 A) 5 A (5 A)
Max. switching voltage 380 VAC, 125 VDC
Max. switching current 5 A (5 A) 8 A (5 A) 5 A (5 A)
4
G6B PCB Power Relay
G
6
B
Characteristics
Note 1. The values here are initial values.
2.The G6B-1177P(-FD)-ND model is flux-resistant. Do not wash it down with water.
*1. The contact resistance was measured with 1 A at 5 VDC using a voltage-drop method.
*2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was
measured.(Except the location between set/reset coil)
*3. This value was measured at a switching frequency of 120 operations/min.
Model
G6B-1114P-US
G6B-1114P-FD-US
G6B-1174P-US
G6B-1174P-FD-US
G6BU-1114P-US G6BK-1114P-US G6B
-1177P(-FD)-ND-US
G6B-2114P-US
G6B-2114P-FD-US
G6B-2214P-US
G6B-2214P-FD-US
G6B-2014P-US
G6B-2014P-FD-US
Item Classification Single-side stable Single-winding
latching
Double-winding
latching
Built-in operation
indicator & surge
absorption diode
Single-side stable
Contact resistance *1 30 mΩ max.
Operate (set) time 10 ms max.
Release (reset) time 10 ms max.
Min. set pulse width 15 ms (at 23°C)
Min. reset pulse width 15 ms (at 23°C)
Insulation resistance *2 1,000 MΩ min.
Dielectric strength
Between coil and contacts 3,000 VAC, 50/60 Hz for 1 min 2,000 VAC,
50/60 Hz for 1 min 3,000 VAC, 50/60 Hz for 1 min
Between contacts of the same
polarity 1,000 VAC, 50/60 Hz for 1 min
Between contacts of different
polarity 2,000 VAC,
50/60 Hz for 1 min
Between set and reset coils 250 VAC,
50/60 Hz for 1 min
Impulse withstand voltage (between coil and contacts) 6 kV 1.2 × 50 μs 4.5 kV 1.2 × 50 μs 6 kV 1.2 × 50 μs
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance Destruction 1,000 m/s2
Malfunction 100 m/s2300 m/s2100 m/s2
Durability Mechanical 50,000,000 operations min. (at 18,000 operations/hr)
Electrical 100,000 operation min. (at 1,800 operations/hr under rated load)
Failure rate (P level) (reference value) *3 10 mA at 5 VDC
Ambient operating temperature -25°C to 70°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 3.5 to 4.6 g Approx. 3.5 g Approx. 3.7 g Approx. 5.4 g Approx. 4.5 g
5
G6B PCB Power Relay
G
6
B
Engineering Data
Maximum Switching Current
G6B-1114P-US
G6B-1174P-FD-US
G6B-1174P-US
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
Durability
Ambient Temperature vs.
Maximum Coil Voltage
G6B-1114P-US
G6B-1174P-US
G6B-1174P-FD-US
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
G6B-1114P-US
G6B-1174P-US
G6B-1174P-FD-US
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
Note: The maximum coil voltage refers to the
maxi-mum value in a varying range of
operating power voltage, not a continuous
voltage.
Ambient Temperature vs. Must
Operate and Must Release Voltage
G6B-1114P-US
Mutual Magnetic Interference
G6B-1114P-US G6B-1114P-US
Switching current (A)
Switching voltage (V)
40
20
10
5
3
2
1
0.5
0.3
0.2
0.1
AC resistive load
AC
inductive
load
cosφ = 0.4
DC resistive load
DC inductive load
(L/R = 7 ms)
0 3 5 10 20 30 100 300 500
Switching current (A)
Switching voltage (V)
100
50
30
10
8
5
3
2
1
0.5
0.3
0.1
AC resistive load
AC
inductive
load
DC resistive load
DC inductive load
0 3 5 10 30 50 100 380 1,000
Switching current (A)
Switching voltage (V)
100
50
30
10
5
3
2
1.5
1
0.5
0.3
0.1
AC resistive
load
DC resistive load
0 3 5 10 30 50 100 300 500 1,000
AC inductive load
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
AC
resistive
load
G6B-2114P-FD-US
G6B-2214P-FD-US
G6B-2014P-FD-US
1,000
500
300
100
50
30
10
5
3
1
0 1 2 3 4 5 6 7 8 9 10
G6B-1114P-US
250 VAC/30 VDC resistive load
G6B-1114P-US
G6B-1174P-FD-US
G6B-1174P-US
250 VAC/30 VDC inductive load
(cosφ = 0.4, L/R = 7 ms)
G6B-1174P-US
250 VAC/30 VDC
resistive load
G6B-1174P-FD-US
250 VAC/30 VDC resistive load
Durability (x10
4
operations)
Switching current (A)
Higher
capacity
Durability (x10
4
operations)
1,000
500
300
100
50
30
10
5
3
1
0 1 1.5 2 3 4 5 6 7 8 9 10
Switching current (A)
G6B-2114P-FD-US
G6B-2214P-FD-US
G6B-2014P-FD-US
250 VAC resistive load
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
250 VAC/30 VDC resistive load
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
250 VAC/30 VDC inductive load
(cosφ = 0.4, L/R = 7 ms)
Maximum coil voltage (%)
200
180
160
140
130
120
110
100
80
600 20 23 30 40 50 60 70 80 90
G6B-1114P-US
G6B-1174P-US
G6B-1174P-FD-US
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
Ambient temperature (°C)
100
80
60
40
20
0
Ambient temperature (°C)
Must-operate/must-release voltage (%)
Sample:
G6B-1114P-US
Number of Relays: 5 pcs
40 20 0 20 40 60 80
Must operate voltage
Must release voltage
max.
min.
X
max.
min.
X
2.54 mm
+1.0
+0.5
0
0.5
1.0 Average value
Test
Initial stage
+1.0
+0.5
0
0.5
1.0 Average value
Test
Initial stage
Must operate voltage
Must release voltage
De-energized
Sample
Energized
Sample
Change rate on the
basis of initial value (%)
Change rate on the
basis of initial value (%)
6
G6B PCB Power Relay
G
6
B
Dimensions
Shock Malfunction
Hot Start
Z'
Z
Unit: m/s
2
Y
Y'
X
X'
Energized
200
100
300
400
200
100
300
300
300
400
Shock direction
Y
Y'
XX'
Z
Z'
(Coil)
Sample: G6B-1114P-US
Number of Relays: 12 pcs
Test Conditions: Shock is applied in ±X, ±Y,
and ±Z directions three times each with without
energizing the Relays
to check the number of
malfunctions.
Requirement: None
malfuction 100 m/s
2
Z'
Z
Unit: m/s2
Y
Y'
X
X'
Energized
600
1,000
1,000
1,000
1,000
1,000
1,000
Shock direction
Y
Y'
XX'
Z
Z'
(Coil)
Sample: G6B-1174P-US
G6B-1174P-FD-US
Test Conditions: Shock is applied in ±X, ±Y,
and ±Z directions three times each with without
energizing the Relays
to check the number of
malfunctions.
Requirement: None
malfuction 100 m/s
2
Z'
Shock direction
Y
Y'
XX'
Z
Z'
(Coil)
Z
Unit: m/s
2
Y
Y'
X
X'
1,000
1,000
1,000
1,0001,000
1,000
Reset
Set
700
Sample: G6BK-1114P-US
Number of Relays: 12 pcs
Test Conditions: The value at which
malfunction occurred was measured after
applying shock to the
test piece 3 times each
in 6 directions along 3
axes.
Standard value:
300 m/s2
Ambient temperature (°C)
Sample: G6B-1114P-US
G6B-1174P-FD-US
Number of Relays: 10 pcs
Test: the variation of operating voltage is measured
based on cold start at 23°C, during which rated
voltage is applied to the coil with rated
contact current (5A), and left for 1
hour each under different
ambient
temperatures. 120% applied
110% applied
100% applied
50 40 20 0 20 40 60 80 100
Rate of variability (%)
40
30
20
10
0
10
20
Rate of variability (%)
Ambient temperature (°C)
Sample: G6B-1174P-US
Test: the variation of operating voltage is measured
based on cold start at 23°C, during which rated
voltage is applied to the coil with rated contact
current (8A), and left for 1 hour
each under different ambient
temperatures.
40
30
20
10
0
10
20
120% applied
110% applied
100% applied
50 40 20 0 20 40 60 80 100
Rate of variability (%)
Ambient temperature (°C)
Sample: G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
Test: the variation of operating voltage is
measured based on coil cold start at 23°C, during
which rated voltage is applied to the coil with rated
contact current (5A), and left
for 1 hour each under different
ambient temperatures.
40
30
20
10
0
10
20
120% applied
110% applied
100% applied
50 40 20 0 20 40 60 80 100
(1.2)
(1.1)
10.16 7.62
2.54
0.5<0.4>
0.9<1.0>
0.9
<1.0>
0.85
<0.9>
0.3
3.5
0.5
2.54 Four, 1.1-dia. holes
Note: Orientation marks are indicated as follows:
1
6
34
10 max.
(9.8)*
10 max.
(9.8)*
20 max.
(19.9)*
* Average value
Note: Check carefully
the coil polarity of the
Relay.
1-pole Single-side Stable Models
G6B-1114P(-FD)-US PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Dimensions in pointed brackets < > are
for the Relay mounted to Socket.
Note: Orientation marks are indicated as follows:
(1.2)
(1.2)
10.16 7.62
2.54
0.65
3.5
0.45
2.54 Four, 1.1-dia. holes
1
6
34
10 max.
(9.9)*
12.5 max.
(12.45)*
20.2 max.
(20.0)*
* Average value
Note: Check carefully
the coil polarity of the
Relay.
0.5<0.4>
0.9
<1.0>
0.85
<0.9>
0.9<1.0>
1-pole Single-side Stable Models
G6B-1174P(-FD)-US PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Dimensions in pointed brackets < > are
for the Relay mounted to Socket.
7
G6B PCB Power Relay
G
6
B
(1.2)
(1.1)
10.16 7.62
2.54
0.3
3.5
0.5
2.54 Four, 1.1-dia. holes
1
S
6
R34
10 max.
(9.8)*
10 max.
(9.8)*
20 max.
(19.9)* * Average value
Note: Orientation marks are indicated as follows:
0.5<0.4>
0.9<1.0>
0.9
<1.0>
0.85
<0.9>
Note: Check carefully
the coil polarity of the
Relay.
S: Set coil
R: Reset coil
1-pole Single-winding Latching Model
G6BU-1114P-US
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Dimensions in pointed brackets < > are
for the Relay mounted to Socket.
(1.2)
(1.1)
7.627.622.54
2.54
2.54 Six, 1.1-dia. holes
1
S
6
2
5
R34
0.3
3.5
0.5
10 max.
(9.8)*
10 max.
(9.8)*
20 max.
(19.9)* * Average value
Note: Orientation marks are indicated as follows:
Note: Check carefully
the coil polarity of the
Relay.
S: Set coil
R: Reset coil
0.5<0.4>
0.9<1.0>
0.9
<1.0>
0.85
<0.9>
0.85
<0.9>
1-pole Double-winding Latching Model
G6BK-1114P-US PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Dimensions in pointed brackets < > are
for the Relay mounted to Socket.
7.62
10 max.
(9.9)*
0.3
1.6
1.7
0.65
3.5
15 max.
(14.8)*
20.2 max.
(20)*
* Average value
(1.2)
7.62
(1.11) 10.16 7.62
2.54
2.54 Four, 1.1-dia. holes
1
6
34
10.16 7.62
LED
0.45
3.7
Note: Check carefully the
coil polarity of the Relay.
Note: The G6B-1177P-ND-US model has a flux-resistant
construction. Do not wash it down with water. Pay
attention to the polarity of the coil since the LED and
surge absorption diode are built-in.
0.5<0.4>
0.9<1.0>
0.9
<1.0>
0.85
<0.9>
1-pole Single-side stable Models SPST-NO (1a) (Built-in high capacity operation
indicator & surge absorption diode)
G6B-1177P(-FD)-ND-US PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Dimensions in pointed brackets < > are
for the Relay mounted to Socket.
0.4<0.3>
7.62
0.9<0.8>
11 max.
(10.9)*
11 max.
(10.9)*
20 max.
(19.9)*
* Average value
(1.7)
7.62
(1.11) 10.16 7.62
2.54
2.54 Six, 1.1-dia. holes
1
8
3
6
4
5
1
8
3
6
4
5
1
8
3
6
4
5
10.16 7.62
3.5
Note: Check carefully
the coil polarity of the
Relay.
G6B-2114P-US
G6B-2014P-US
G6B-2214P-US
2-poles Single-side stable Models (SPST-NO (1a) + SPST-NC (1b),
DPST-NC (2c), SPST-NO(1a))
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Dimensions in pointed brackets < > are
for the Relay mounted to Socket.
8
G6B PCB Power Relay
G
6
B
Connecting Sockets Dimensions
(2.71) 10.16 7.62
(1.2)
2.54
2.54 Four, 1.1-dia. holes
3.1
23.2 max.
(23)*
10 max.
(9.9)*
10.1 max.
(10)*
0.4
7.62
0.8
* Average value
10.16 7.62
7
3.5
Socket for 1-pole Single-winding Latching Model and
Single-side Stable Model
P6B-04P
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
(2.71)
2.54
7.627.62
(1.2)
2.54
2.54 Six, 1.1-dia. holes
3.1
23.2 max.
(23)*
10 max.
(9.9)*
10.1 max.
(10)*
0.4
7.62
0.8
* Average value
7.627.622.54
7
3.5
Socket for 1-pole Double-winding Latching Model
P6B-06P PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
(2.61) 10.16 7.62
(1.6)
2.54
2.54 Six, 1.1-dia. holes
3.1
23.2 max.
(23)*
11 max.
(10.8)*
10.1 max.
(10)*
0.4
7.62
0.8
* Average value
10.16 7.62
7
3.5
Socket for Double-pole Single-side Stable
P6B-26P PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Removal Tool
P6B-Y1
Hold-down Clips
P6B-C2
Related Products
The G6B-4 Terminal Relay series with
4-point output is also available.
For details, contact your OMRON sales
representative.
9
G6B PCB Power Relay
G
6
B
Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the
values before use.
UL Recognized: (File No. E41643)
CSA Certified: (File No. LR31928)
EN/IEC, TÜV Certified: (Registration No. R50158246)
Model Contact
form
Coil
ratings Contact ratings Number of test
operations
G6B-1114P-US
G6B-1114P-FD-US 13 to 24
VDC
5 A, 250 VAC (General Use) at 80°C 6,000
5A, 30 VDC at 80°C
1/8HP, 250 VAC at 80°C 1,000
1/6HP, 250 VAC at 80°C
G6B-1174P-US
G6B-1174P-FD-US 13 to 24
VDC
8 A, 250 VAC (General Use) at 80°C
6,000
8 A, 30 VDC at 80°C
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
23 to 24
VDC
5 A, 250 VAC (General Use) at 40°C
5 A, 30 VDC at 40°C
Model Contact
form
Coil
ratings Contact ratings Number of test
operations
G6B-1114P-US
G6B-1114P-FD-US 13 to 24
VDC
5 A, 250 VAC (General Use) at 80°C 6,000
5A, 30 VDC at 80°C
1/6HP, 250 VAC at 80°C 1,000
360WT, 120 VAC at tungsten 80°C 6,000
G6B-1174P-US
G6B-1174P-FD-US 13 to 24
VDC
8 A, 250 VAC (General Use) at 80°C
6,000
8 A, 30 VDC at 80°C
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
23 to 24
VDC
5 A, 250 VAC (General Use) at 40°C
5 A, 30 VDC at 40°C
Model Contact
form
Coil
ratings Contact ratings Number of test
operations
G6B-1114P-US 1 5, 6 12,
24 VDC
5 A, 250 VAC (cosφ = 1) at 70°C
20,000
2 A, 250 VAC (cosφ = 0.4) at 70°C
5 A, 30 VDC (L/R = 0 ms) at 70°C
G6B-1174P-US 1 5, 6 12,
24 VDC
8 A, 250 VAC (cosφ = 1) at 70°C
2 A, 250 VAC (cosφ = 0.4) at 70°C
8 A, 30 VDC (L/R = 0 ms) at 70°C
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
25, 6 12,
24 VDC
5 A, 250 VAC (cosφ = 1) at 70°C
1.5 A, 250 VAC (cosφ = 0.4) at 70°C
5 A, 30 VDC (L/R = 0 ms) at 70°C
10
G6B PCB Power Relay
G
6
B
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
Mounting
When installing more than two Relays
side by side on a PCB, keep the gaps
as shown below.
It may cause a malfunction if heat is
not dissipated smoothly from the
Relay.
No specified mounting direction.
Mounting Height of Sockets and
Precautions
Hold-down clips (for mounting and
removal) are also available.(For P6B-
C2 model) However, it is not suitable
for G6B-1174P and G6B-1177P
models.
Removal tool is also available.
(For P6B-Y1 model) However, it is not
suitable for G6B-1177P model.
Inhibit Circuit of the
G6B-1177P(-FD)-ND-US Model
Do not use under conditions in which a
surge is included in the power supply,
such as when an inductive load is
connected in parallel to the coil. Doing
so will cause damage to the installed
(or built-in) coil surge absorbing diode.
Using SPDT contact of the
SPST-NO+SPST-NC Relay
Do not construct a circuit so that
overcurrent and burning occur if the
NO, NC and SPDT contacts are
short-circuited with the
SPST-NO+SPST-NC Relay.Arcing
may generate short-circuiting between
contacts if there is short-circuiting
because of conversion to the MBB
contact caused by asynchronous
operation of the NO and NC contacts,
the interval between the NO and NC
contacts is small, or a large current is
left open.
Other precautions
The P6B model has a flux-resistant
construction. Do not wash it down with
water.
Perform wiring of No.1 and No. 2 of
the X terminal as COM for double-
winding latching as shown below. The
operation stability improves by doing
this.
Check carefully the coil polarity (+ and -)
of the Relay G6B-1177P(-FD)-ND-US.
Do not reverse the polarity when
connecting. Otherwise the built-in coil
surge absorption diode may be
damaged.
This Relay is a Power Relay which is
suitable for power load switching. Do
not use the G6B for signal purposes
such as micro load switching under 10
mA.
Correct Use
Pitch: 2.54 mm × 2 min.
between terminals
Pitch:
2.54 mm × 2 min.
between terminals
*17 mm max.
7 mm max.
* 19.5 mm max. for
G6B-1174P-FD-US,
G6B-1174P-US models
and 22 mm max. for
G6B-1177P-FD-ND-US,
G6B-1177P-ND-US models.
L
Inductive
load G6B
Coil
Coil surge
absorption
diode
COM
6
S
1
5
R
2
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K021-E1-14
0316(0207)(O)
Note: Do not use this document to operate the Unit.