SPECIFICATION
MPS-45-3.3 MPS-45-5 MPS-45-7.5 MPS-45-12 MPS-45-13.5 MPS-45-15 MPS-45-24 MPS-45-27 MPS-45-48
MODEL
DC�VOLTAGE
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
OUTPUT
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISE�TIME
HOLD�TIME (Typ.)
VOLTAGE�RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSH�CURRENT (Typ.)
LEAKAGE�CURRENT
WORKING�HUMIDITY
WORKING�TEMP.
STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER�LOAD
OVER�VOLTAGE
AC�CURRENT (Typ.)
3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V
8A 8A 5.4A 3.7A 3.3A 3A 1.9A 1.7A 1A
0�~�10.7A 0�~�10.5A 0�~�7A 0�~�4.4A 0�~�3.9A 0�~�3.5A 0�~�2.2A 0�~�1.95A 0�~�1.1A
26.4W 40W 40.5W 44.4W 44.6W 45W 45.6W 45.9W 48W
52W(+3.3V:35W)with�18CFM�min.�Forced�air�convection
80mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
3.0% 3.0% 3.0% 2.0%
2.0%
2.0% 2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
3.0% 3.0% 3.0% 2.0%
90�~�264VAC����������127�~�370VDC
47�~�440Hz
65% 72% 75% 76% 76% 77% 78% 78% 78%
1.2A/115VAC����������0.7A/230VAC
COLD�START 15A/115VAC����������30A/230VAC
<0.3mA /�264VAC
53�~�75W�(3.3V:36�~�55W) rated�output�power
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
-20�~�+85 ,�10�~�95%�RH
0.04%/ (0�~�50
10�~�500Hz,�2G�10min./1cycle,�Period�for�60min.each�along�X, Y,�Z�axes
366.1Khrs�min.������MIL-HDBK-217F�(25 )
127*76.2*28mm�(L*W*H)
0.18Kg;�72pcs/15.1Kg/1.35CUFT
File�Name:MPS-45-SPEC���2005-10-07
800ms,�30ms/230VAC����������1200ms,�30ms/115VAC�at�full�load
50ms/230VAC����������16ms/115VAC�at�full�load
-10�~�+60 (Refer�to�output�load�derating�curve)
20�~�90%�RH�non-condensing
SAFETY STANDARDS
HARMONIC�CURRENT
EMS�IMMUNITY
UL2601-1, TUV�EN60601-1,�IEC601-1 Approved
Compliance�to�EN55011�(CISPR11)�Class�B
Compliance�to EN61000-3-2,-3
Compliance�to EN61000-4-2,3,4,5,6,8,11;�ENV50204,�EN60601-1-2�Medical�level,�criteria A
45W�Single�Output�Medical Type MPS-45 series
ENVIRONMENT
SAFETY &
EMC
(Note�4)
PROTECTION
EMI�CONDUCTION�&�RADIATION
WITHSTAND�VOLTAGE
ISOLATION�RESISTANCE
I/P-O/P:4KVAC�����I/P-FG:1.5KVAC�����O/P-FG:0.5KVAC
I/P-O/P,�I/P-FG:100M�Ohms/500VDC
RIPPLE�&�NOISE�(max.) Note.2
VOLTAGE�TOLERANCE Note.3
OUTPUT�POWER�(max.)
3.8�~�4.46V 5.75�~�6.75V 8.63�~�10.1V 13.8�~�16.2V 15.5�~�18.2V
17.25�~�20.25V
27.6�~�32.4V 31�~�36.45V 55.2�~�64.8V
VOLTAGE ADJ.�RANGE 2.97�~�3.63V 4.5�~�5.5V 6.75�~�8.25V 10.8�~�13.2V 12.2�~�14.85V 13.5�~�16.5V 21.6�~�26.4V 24.3�~�29.7V 43.2�~�52.8V