MPS-45 series
45W Single Output for Medical Type
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082 Fax: 508-823-8181
WWW.ASTRODYNE.COM
SPECIFICATION
MPS-45-3.3 MPS-45-5 MPS-45-7.5 MPS-45-12 MPS-45-13.5 MPS-45-15 MPS-45-24 MPS-45-27 MPS-45-48
MODEL
DC�VOLTAGE
RATEDCURRENT
CURRENT�RANGE
RATEDPOWER
OUTPUT
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISETIME
HOLD�TIME (Typ.)
VOLTAGE�RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSH�CURRENT (Typ.)
LEAKAGE�CURRENT
WORKING�HUMIDITY
WORKING�TEMP.
STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER�LOAD
OVER�VOLTAGE
AC�CURRENT (Typ.)
3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V
8A 8A 5.4A 3.7A 3.3A 3A 1.9A 1.7A 1A
0�~�10.7A 0�~�10.5A 0�~�7A 0�~�4.4A 0�~�3.9A 0�~�3.5A 0�~�2.2A 0�~�1.95A 0�~�1.1A
26.4W 40W 40.5W 44.4W 44.6W 45W 45.6W 45.9W 48W
52W(+3.3V:35W)with18CFM�min.�Forcedair�convection
80mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
3.0% 3.0% 3.0% 2.0%
2.0%
2.0% 2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
3.0% 3.0% 3.0% 2.0%
90�~�264VAC����������127�~�370VDC
47�~�440Hz
65% 72% 75% 76% 76% 77% 78% 78% 78%
1.2A/115VAC����������0.7A/230VAC
COLD�START 15A/115VAC����������30A/230VAC
<0.3mA /�264VAC
53�~�75W�(3.3V:36�~�55W) rated�output�power
Protection�type�: Hiccupmode,�recovers�automaticallyafter�fault�conditionis�removed
Protection�type�: Hiccupmode,�recovers�automaticallyafter�fault�conditionis�removed
-20�~�+85 ,�10�~�95%�RH
0.04%/ (0�~�50
10�~�500Hz,2G�10min./1cycle,�Periodfor�60min.each�alongX, Y,�Zaxes
366.1Khrs�min.����MIL-HDBK-217F�(25 )
127*76.2*28mm�(L*W*H)
0.18Kg;�72pcs/15.1Kg/1.35CUFT
File�Name:MPS-45-SPEC���2005-10-07
800ms,�30ms/230VAC�������1200ms,30ms/115VACat�full�load
50ms/230VAC������16ms/115VACat�full�load
-10�~�+60 (Referto�output�loadderating�curve)
20�~�90%RH�non-condensing
SAFETY STANDARDS
HARMONIC�CURRENT
EMS�IMMUNITY
UL2601-1, TUV�EN60601-1,�IEC601-1 Approved
Compliance�to�EN55011�(CISPR11)Class�B
Compliance�to EN61000-3-2,-3
Compliance�to EN61000-4-2,3,4,5,6,8,11;ENV50204,�EN60601-1-2Medical�level,�criteria A
45WSingleOutputMedical Type MPS-45 series

 






 


 


ENVIRONMENT
SAFETY &
EMC
(Note�4)
PROTECTION
EMI�CONDUCTION�&RADIATION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:4KVAC���I/P-FG:1.5KVAC����O/P-FG:0.5KVAC
I/P-O/P,�I/P-FG:100MOhms/500VDC
RIPPLE�&�NOISE(max.) Note.2
VOLTAGE�TOLERANCE Note.3
OUTPUT�POWER�(max.)
3.8�~�4.46V 5.75�~�6.75V 8.63~�10.1V 13.8�~16.2V 15.5�~�18.2V
17.25�~�20.25V
27.6�~�32.4V 31~�36.45V 55.2�~�64.8V
VOLTAGE ADJ.�RANGE 2.97�~�3.63V 4.5�~�5.5V 6.75�~�8.25V 10.8�~�13.2V 12.2�~�14.85V 13.5�~�16.5V 21.6�~�26.4V 24.3�~�29.7V 43.2�~�52.8V
MPS-45 series
45W Single Output for Medical Type
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082 Fax: 508-823-8181
WWW.ASTRODYNE.COM
File�Name:MPS-45-SPEC���2005-10-07
Unit:mm
fosc�:�45KHz
DCOutput�Connector�(CN2)�:Molex�5273-06�or�equivalent
Pin�No.
1,2,3
4,5,6
Assignment
+V
-V
MatingHousing
Molex�5195
orequivalent
Terminal
Molex�5194
orequivalent
ACInput�Connector�(CN1)�:Molex�5277-02��or�equivalent
Pin�No.
1
2
Assignment MatingHousing
Molex�5195 Molex�5194
orequivalent or�equivalent
Terminal
LOAD�(%)
Block�Diagram
Mechanical�Specification
Static�CharacteristicsOutput�Derating
-V
FG
I/P
CIRCUIT
CONTROL
O.L.P. PWM
O.V.P.
SWITCH-
RECTIFIERS
FILTER
EMI
FILTER &
POWER
ING
DETECTION
RECTIFIERS
FILTER
&+V
AMBIENT�TEMPERATURE�( )
(HORIZONTAL)
-10 0 10 20 30 40 50 60
20
40
60
80
100 Others
3.3V,5V
90 100 110 135 155 264230
100
90
80
70
60
50
40
INPUT�VOLTAGE�(V)60Hz
LOAD(%)
5.6
5.6
64.8
28
76.2
M1
127
115.8
FS1
CN1
ACFUSE
T2A/250V
T2A/250V
2
FS2
1
ACFUSE
SVR1
LED
4- 3.8
4
5
6
1
3
2
CN2
FG
M2
AC/N
AC/L
45WSingleOutputMedical Type MPS-45 series
MPD-45 series
45W Dual Output for Medical Type
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082 Fax: 508-823-8181
WWW.ASTRODYNE.COM
SPECIFICATION
MPD-45A MPD-45B
MODEL
DC�VOLTAGE
RATEDCURRENT
CURRENT�RANGE
RATEDPOWER
OUTPUT
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISETIME
HOLD�TIME (Typ.)
VOLTAGE�RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSH�CURRENT (Typ.)
LEAKAGE�CURRENT
WORKING�TEMP.
WORKING�HUMIDITY
STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER�LOAD
OVER�VOLTAGE
AC�CURRENT (Typ.)
5V 12V
CH2
5V
CH1
24V
CH2
3.2A 2A 3.2A 1.2A
0.4�~�5A 0.2�~�2.5A 0.4�~�5A 0.2�~�1.8A
40W 44.8W
52W�with�18CFMmin.�Forced�airconvection
60mVp-p 120mVp-p 60mVp-p 150mVp-p
4.0%
CH1:4.5�~�5.5V
7.0% 4.0%
CH1:4.5�~�5.5V
7.0%
1.0% 2.0% 1.0% 2.0%
3.0% 4.0% 3.0% 4.0%
90�~�264VAC����������127�~�370VDC
47�~�440Hz
76% 78%
1.2A/115VAC����������0.7A/230VAC
COLD�START 15A/115VAC����������30A/230VAC
<0.3mA /�264VAC
53�~�75W rated�outputpower
5.75�~�6.75Von�CH1
Protection�type�: Hiccupmode,�recovers�automaticallyafter�fault�conditionis�removed
Protection�type�: Hiccupmode,�recovers�automaticallyafter�fault�conditionis�removed
-20�~�+85 ,�10�~�95%�RH
0.04%/ (0�~50 )�on�+5Voutput
10�~�500Hz,2G�10min./1cycle,�Periodfor�60min.each�alongX, Y,�Zaxes
291.3Khrs�min.����MIL-HDBK-217F�(25 )
127*76.2*28mm�(L*W*H)
0.2Kg;�72pcs/17.4Kg/1.35CUFT
File�Name:MPD-45-SPEC���2005-09-13
800ms,�20ms/230VAC�������800ms,20ms/115VACat�full�load
50ms/230VAC������16ms/115VACat�full�load
-10�~�+60 (Referto�output�loadderating�curve)
20�~�90%RH�non-condensing
SAFETY STANDARDS
HARMONIC�CURRENT
EMS�IMMUNITY
UL2601-1, TUV�EN60601-1,�IEC601-1 Approved
Compliance�to�EN55011�(CISPR11)Class�B
Compliance�to EN61000-3-2,-3
Compliance�to�EN61000-4-2,3,4,5,6,8,11;�ENV50204,�EN60601-1-2Medical�level,�criteria A
VOLTAGE ADJ.�RANGE
45WDualOutputMedical Type MPD-45 series

 






RIPPLE�&�NOISE(max.) Note.2
VOLTAGE�TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note�4)
PROTECTION
EMI�CONDUCTION�&RADIATION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:4KVAC���I/P-FG:1.5KVAC����O/P-FG:0.5KVAC
I/P-O/P,�I/P-FG:100MOhms/500VDC
 


 


OUTPUT�POWER�(max.)
CH1
OUTPUT�NUMBER
MPD-45 series
45W Dual Output for Medical Type
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082 Fax: 508-823-8181
WWW.ASTRODYNE.COM
File�Name:MPD-45-SPEC���2005-09-13
Unit:mm
fosc�:�45KHz
DCOutput�Connector�(CN2)�:Molex�5273-06�or�equivalent
Pin�No.
1
2,3
4,5
6
Assignment
+V
+5V
COM
NC
Mating�Housing
Molex�5195
orequivalent
Terminal
Molex�5194
orequivalent
ACInput�Connector�(CN1)�:Molex�5277-02��or�equivalent
Pin�No.
1
2
Assignment MatingHousing
Molex�5195 Molex�5194
orequivalent or�equivalent
Terminal
LOAD�(%)
Block�Diagram
Mechanical�Specification
Static�CharacteristicsOutput�Derating
AMBIENT�TEMPERATURE�( )
(HORIZONTAL)
-10 0 10 20 30 40 50 60
20
40
60
80
100
90 100 110 135 155 264230
100
90
80
70
60
50
40
INPUT�VOLTAGE�(V)60Hz
LOAD(%)
O.V.P.
CONTROL
ING
COM
+5V
RECTIFIERS
&
FILTER
SWITCH-
POWER
FILTER
&
RECTIFIERS
O.L.P.
DETECTION
CIRCUIT
PWM
FILTER
&
RECTIFIERS
+V
FG
I/P FILTER
EMI
5.6
M1
127
115.8
FS1
CN1
ACFUSE
28
4- 3.8
76.2
64.8 5.6
T2A/250V
T2A/250V
2
FS2
1
ACFUSE
SVR1
4
5
6
1
3
2
CN2
FG
M2
AC/N
AC/L
45WDualOutputMedical Type MPD-45 series
MPT-45 series
45W Triple Output for Medical Type
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082 Fax: 508-823-8181
WWW.ASTRODYNE.COM
SPECIFICATION
MPT-45A MPT-45B MPT-45C
MODEL
DC�VOLTAGE
RATEDCURRENT
CURRENT�RANGE
RATEDPOWER
OUTPUT
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISETIME
HOLD�TIME (Typ.)
VOLTAGE�RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSH�CURRENT (Typ.)
LEAKAGE�CURRENT
WORKING�TEMP.
WORKING�HUMIDITY
STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER�LOAD
OVER�VOLTAGE
AC�CURRENT (Typ.)
5V 12V
CH2
-5V
CH3
5V
CH1
12V
CH2
-12V
CH3
5V
CH1
15V
CH2
-15V
CH3
3A 2A 0.3A 3A 2A 0.3A 3A 1.6A 0.3A
0.4�~�5A 0.2�~�2.5A 0�~�0.5A 0.4�~�5A 0.2�~�2.5A 0�~�0.5A 0.4�~�5A 0.2�~�2.3A 0�~�0.5A
40.5W 42.6W 43.5W
52W�with�18CFMmin.�Forced�airconvection
60mVp-p 120mVp-p 60mVp-p 60mVp-p 120mVp-p 100mVp-p 60mVp-p 120mVp-p 100mVp-p
4.0% 4.0% 4.0%
CH1:4.5�~�5.5V
7.0% 5.0% 5.0% 5.0%7.0% 7.0%
1.0% 1.0% 1.0%2.0% 1.0% 1.0% 1.0%
1.0% 1.0% 1.0%
2.0% 2.0%
3.0% 3.0% 3.0%4.0% 4.0% 4.0%
90�~�264VAC����������127�~�370VDC
47�~�440Hz
73% 75% 75%
1.2A/115VAC����������0.7A/230VAC
COLD�START 20A/115VAC����������40A/230VAC
<0.3mA /�264VAC
53�~�75W rated�outputpower
5.75�~�6.75VDCon�CH1
Protection�type�: Hiccupmode,�recovers�automaticallyafter�fault�conditionis�removed
Protection�type�: Hiccupmode,�recovers�automaticallyafter�fault�conditionis�removed
-20�~�+85 ,�10�~�95%�RH
0.04%/ (0�~50 )�on�+5Voutput
10�~�500Hz,2G�10min./1cycle,�Periodfor�60min.each�alongX, Y,�Zaxes
271.5Khrs�min.����MIL-HDBK-217F�(25 )
127*76.2*28mm�(L*W*H)
0.21Kg;�72pcs/18Kg/1.35CUFT
File�Name:MPT-45-SPEC���2005-09-13
800ms,�20ms/230VAC�������800ms,20ms/115VACat�full�load
80ms/230VAC������12ms/115VACat�full�load
-10�~�+60 (Referto�output�loadderating�curve)
20�~�90%RH�non-condensing
SAFETY STANDARDS
HARMONIC�CURRENT
EMS�IMMUNITY
UL2601-1, TUV�EN60601-1,�IEC601-1 Approved
Compliance�to�EN55011�(CISPR11)Class�B
Compliance�to EN61000-3-2,-3
Compliance�to�EN61000-4-2,3,4,5,6,8,11;�ENV50204,�EN60601-1-2Medical�level,�criteria A
VOLTAGE ADJ.�RANGE
45W Triple�Output�Medical Type MPT-45 series

 






RIPPLE�&�NOISE(max.) Note.2
VOLTAGE�TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note�4)
PROTECTION
EMI�CONDUCTION�&RADIATION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:4KVAC���I/P-FG:1.5KVAC����O/P-FG:0.5KVAC�1min.
I/P-O/P,�I/P-FG:100MOhms/500VDC
 


 


OUTPUT�POWER�(max.)
CH1
OUTPUT�NUMBER
MPT-45 series
45W Triple Output for Medical Type
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082 Fax: 508-823-8181
WWW.ASTRODYNE.COM
File�Name:MPT-45-SPEC���2005-09-13
Unit:mm
fosc�:�45KHz
DCOutput�Connector�(CN2)�:Molex�5273-06�or�equivalent
ACInput�Connector�(CN1)�:Molex�5277-02��or�equivalent
Pin�No.
1
2
Assignment MatingHousing
Molex�5195 Molex�5194
orequivalent or�equivalent
Terminal
LOAD�(%)
Block�Diagram
Mechanical�Specification
Static�CharacteristicsOutput�Derating
AMBIENT�TEMPERATURE�( )
(HORIZONTAL)
-10 0 10 20 30 40 50 60
20
40
60
80
100
90 100 110 135 155 264230
100
90
80
70
60
50
40
INPUT�VOLTAGE�(V)60Hz
LOAD(%)
5.6
M1
127
115.8
5.6
64.8
28
76.2
FS1
CN1
ACFUSE
T2A/250V
T2A/250V
2
FS2
1
ACFUSE
SVR1
4- 3.8
4
5
6
1
3
2
CN2
FG
M2
AC/N
AC/L
45W Triple�Output�Medical Type MPT-45 series
O.V.P.
CONTROL
ING
-V
COM
RECTIFIERS
&
FILTER
SWITCH-
POWER
FILTER
&
RECTIFIERS
O.L.P.
DETECTION
CIRCUIT
PWM
FILTER
FILTER
&
&
RECTIFIERS
RECTIFIERS
+5V
+V
FG
I/P FILTER
EMI
Pin�No.
1
2,3
4,5
6
Assignment
+V
+5V
COM
-V
Mating�Housing
Molex�5195
orequivalent
Terminal
Molex�5194
orequivalent