MODEL NUMBERS D2425D D2440D H12D4825D H12D4840D
OUTPUT SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms] 24-280 24-280 48-530 48-530
Load Current Range [Arms] .15-25 .15-40 .15-25 .15-40
Transient Overvoltage [Vpk] 600 600 1200 1200
Max. Surge Current, (16.6ms) [Apk] 250 625 250 625
Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6
Thermal Resistance Junction to Case (RθJC) [˚C/W] 1.02 .63 1.02 .63
Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 260 1620 260 1620
Max. Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 10
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]500 500 500 500
Max. Turn-On Time 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle
Max. Turn-Off Time 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle
Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5
INPUT SPECIFICATIONS DC CONTROL
Control Voltage Range 4-15Vdc
Max. Turn-On Voltage 4.0 Vdc
Min. Turn-Off Voltage 1.0 Vdc
Nominal Input Impedance 330 Ohms
Typical Input Current @ 5Vdc 12mA
GENERAL NOTES
All parameters at 25ºC and per section unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required, for derating curves see page 2.
Turn-on time for random turn-on (-10) versions is 0.1 msec.
Zero Voltage and Random
Turn-On Switching
SCR Output
Industry Standard Package
Panel Mount
FastFax Document No. 165
DUAL.032698, PAGE 1 OF 2
Two totally independent AC output
relays come in a single standard panel-
mount package. Utilizing an AC switch
output with internal snubber, relays
provide greater protection against false
triggering. Model choices include zero-
voltage or random turn-on (phase con-
trollable) switching.
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
Dual Relays
25-40Amp • 120/240, 480 Vac • AC Output
Crydom Heat Sinks offer excellent thermal
management and are perfectly matched to the
load current ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink specifica-
tion sheet for all the details.
©1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: vertrieb@crydom.com
60
40
20
02010 30 5040 10 20 30 40 50 60 70 80
Load Current [Arms] Max Ambient Temp. [ºC]
Max Allowable Base Temp. [ºC]
Power Dissipation [W]
25A LIMIT
(1 SECTION)
50A LIMIT
(2 SECTIONS)
95
105
75
85
0.5ºC/W
1.0ºC/W
2.0ºC/W
5.0ºC/W
240V Model
B1 LOAD B
B2
A2
A1 120/240Vrms 120/240Vrms
-- B CONTROL
+ B CONTROL
-- A CONTROL
+ A CONTROL
LOAD A
100
80
60
40
20
04020 60 10080 10 20 30 40 50 60 70 80
Load Current [Arms] Max Ambient Temp. [ºC]
Max Allowable Base Temp. [ºC]
Power Dissipation [W]
40A LIMIT
(1 SECTION)
80A LIMIT
(2 SECTIONS)
100
105
90
95
1.0ºC/W
2.0ºC/W
5.0ºC/W
25A 40A
0.5ºC/W
480V Model
B1
LOAD B
B2A2A1
480Vrms
480Vrms
+ B CONTROL
-- B CONTROL
LOAD A
-- A CONTROL
+ A CONTROL
All dimensions are in inches (millimeters)
1.87
(47.5)
.85
(21.6)
1.31
(33.2)
1.00
(25.4)
1.17
(29.7) FASTON
TERMINAL
.250 X .032
(4 PLACES)
PIN .025 SQ.
.100 CENTERS
4 PLACES
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
DUAL SOLID STATE RELAY DUAL SOLID STATE RELAY
± 4-15VDC
CONTROL B
CONTROL A
4-15VDC ±CONTROL B
CONTROL A
A1
A2 B1
B2
120/24OV - 20A
120/24OV - 20A
.85
(21.6)
1.31
(33.2)
.15
(3.8)
.50
(12.7)
.45
(11.4)
.55
(14.0)
2.30
(58.4)
1.80
(45.7)
.77
(19.6)
1.37
(34.8)
1.87
(47.5) 1.60
(40.6)
MOUNTING HOLE/SLOT
.017 (4.3) DIA.
2 PLC'S
A1 A2
120/24OV - 20A 120/24OV - 20A
B1 B2
1.80
(45.7)
2.30
(58.4)
+ +
.250 X .032 FASTON
TERMINAL
(4 PLACES)
.187 X .032
FASTON
TERMINAL
(4 PLACES)
CURRENT DERATING CURVES
WIRING DIAGRAMS
120/240V MODEL 480V MODEL
AVAILABLE OPTIONS
-10 Random Turn-On,
Phase Controllable
(240V Only)
Example: D2440D-10
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc 109Ohm
Max. Capacitance Input/Output 10 pF
Ambient Operating Temperature Range -40 to 80ºC
Ambient Storage Temperature Range -40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical) 3.0 oz. (86.5g)
Encapsulation: Thermally Conductive Epoxy
Terminals: .25” Fastons, .025” Square Pins
APPROVALS
UL E116949
CSA LR81689 (240V only)
VDE 5902 UG
FastFax Document No. 165
DUAL.032698, PAGE 2 OF 2
Dual Relays
25-40Amp • 120/240, 480 Vac • AC Output
©1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: vertrieb@crydom.com