1
CSM_E2EQ_DS_E_7_1
Spatter-resistant Proximity Sensor
E2EQ
Spatter-resistant Fluororesin-
coated Proximity Sensor
Superior spatter resistance.
Long Sensing-distance Models added for sensing
distances up to 15 mm.
Pre-wired Smartclick Connector Models are also
available.
Be sure to read Safety Precautions on
page 6.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Ordering Information
Sensors [Refer to Dimensions on page 7.]
Pre-wired Models
Long Sensing-distance Models
Standard Models
Pre-wired Smartclick Connector Models (M12)
Long Sensing-distance Models
Standard Models
Appearance Sensing distance Output configuration Operation mode Model
M12
DC 2-wire
(no polarity) NO
E2EQ-X4X1 2M
M18 E2EQ-X8X1 2M
M30 E2EQ-X15X1 2M
Shielded
4 mm
8 mm
15 mm
Appearance Sensing distance Output configuration Operation mode Model
M12
DC 2-wire NO
E2EQ-X3D1 2M
M18 E2EQ-X7D1 2M
M30 E2EQ-X10D1 2M
Shielded
3 mm
7 mm
10 mm
Appearance Sensing distance Output configuration Operation mode Model
M12 DC 2-wire
(no polarity)
(3)-(4)
pin arrangement
NO
E2EQ-X4X1-M1TJ 0.3M
M18 E2EQ-X8X1-M1TJ 0.3M
M30 E2EQ-X15X1-M1TJ 0.3M
Shielded
4 mm
8 mm
Standard Models Sensing distance Output configuration Operation mode Model
M12
DC 2-wire
(1)-(4)
pin arrangement
NO
E2EQ-X3D1-M1TGJ 0.3M
M18 E2EQ-X7D1-M1TGJ 0.3M
M30 E2EQ-X10D1-M1TGJ 0.3M
Shielded
3 mm
7 mm
10 mm
E2EQ
2
Pre-wired Connector Models (M12)
Long Sensing-distance Models
Standard Models
Accessories (Order Separately)
Sensor I/O Connectors (M12, Sockets on One Cable End)
(Models with Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.)
[Refer to XS2, XS5.]
Note: Refer to Introduction to Sensor I/O Connectors/Sensor Controllers for details.
Ratings and Specifications
Long Sensing-distance Models
*1. Use the Sensor within the range in which the green indicator is ON.
*2. The response frequency is an average value.
*3. The residual voltage is 5 V. Make sure that the device connected to the Sensor can withstand the residual voltage.
Appearance Sensing distance Output configuration Operation mode Model
M12 DC 2-wire
(without polarity)
(3)-(4)
pin arrangement
NO
E2EQ-X4X1-M1J 0.3M
M18 E2EQ-X8X1-M1J 0.3M
M30 E2EQ-X15X1-M1J 0.3M
Standard Models Sensing distance Output configuration Operation mode Model
M12
DC 2-wire
(1)-(4)
pin arrangement
NO
E2EQ-X3D1-M1GJ 0.3M
M18 E2EQ-X7D1-M1GJ 0.3M
M30 E2EQ-X10D1-M1GJ 0.3M
Appearance Cable length Sensor I/O Connector model number Applicable Proximity Sensor model number
2 m XS2F-D421-DC0-F
E2EQ-X@X1-M1J
5 m XS2F-D421-GC0-F
2 m XS2F-D422-DC0-F
5 m XS2F-D422-GC0-F
2 m XS2F-D421-DA0-F
E2EQ-X@D1-M1GJ
5 m XS2F-D421-GA0-F
2 m XS2F-D422-DA0-F
5 m XS2F-D422-GA0-F
2 m XS5F-D421-D80-F E2EQ-X@X1-M1TJ
E2EQ-X@D1-M1TGJ
5 m XS5F-D421-G80-F
Model E2EQ-X4X1
E2EQ-X4X1-M1(T)J
E2EQ-X8X1
E2EQ-X8X1-M1(T)J
E2EQ-X15X1
E2EQ-X15X1-M1(T)J
Item
Sensing distance 4 mm 10% 8 mm 10% 15 mm 10%
Set distance *10 to 3.2 mm 0 to 6.4 mm 0 to 12 mm
Differential travel 15% max. of sensing distance
Standard sensing object Iron, 12 12 1 mm Iron, 18 18 1 mm Iron, 30 30 1 mm
Response frequency *21 kHz 0.5 kHz 0.25 kHz
Control
output
Load current 3 to 100 mA
Residual voltage *35 V max. (Load current: 100 mA, Cable length: 2 m)
Operation mode (with sensing
object approaching) Load ON: NO; For details, refer to the timing charts on page 5.
Protection circuits Load short-circuit protection, Surge suppressor
Ambient temperature range Operating: 25 to 70C, Storage: 40 to 85C, (with no icing or condensation)
Temperature influence 15% max. of sensing distance at 23C in the temperature range of 40 to 85C
10% max. of sensing distance at 23C in the temperature range of 25 to 70C
15% max. of sensing distance at 23C in
the temperature range of 25 to 70C
Voltage influence 1% max. of sensing distance at rated voltage in the rated voltage 15% range
Shock resistance Destruction: 1,000m/s2 10 times each in X, Y, and Z directions
Connection method Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
Weight
(packed
state)
Pre-wired Models Approx. 65 g Approx. 140 g Approx. 190 g
Pre-wired
Connector Models Approx. 20 g Approx. 40 g Approx. 90 g
Shielded
4 mm
8 mm
15 mm
Shielded
3 mm
7 mm
10 mm
Straight
L-shape
Straight
L-shape
Smartclick
Connector
Straight
E2EQ
3
Standard Models
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
Common Ratings and Performance
Model E2EQ-X3D1
E2EQ-X3D1-M1(T)GJ
E2EQ-X7D1
E2EQ-X7D1-M1(T)GJ
E2EQ-X10D1
E2EQ-X10D1-M1(T)GJ
Item
Sensing distance 3 mm ±10% 7 mm ±10% 10 mm ±10%
Set distance 0 to 2.4 mm 0 to 5.6 mm 0 to 8 mm
Differential travel 10% max. of sensing distance
Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
Response frequency *1 kHz 500 Hz 400 Hz
Control
output
Load current 3 to 100 mA
Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m)
Operation mode (with sensing
object approaching) Load ON: NO; For details, refer to the timing charts on page 5.
Protection circuits Load short-circuit protection, Surge suppressor
Ambient temperature range Operating/Storage: 25 to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Connection method E2EQ-X@D1: Pre-wired Models (Standard cable length: 2 m)
E2EQ-X@D1-M1GJ: Pre-wired Connector Models (Standard cable length: 300mm)
Weight
(packed
state)
Pre-wired Models Approx. 120 g Approx. 160 g Approx. 220 g
Pre-wired
Connector Models Approx. 80 g Approx. 110 g Approx. 190 g
Model E2EQ-X4X1
E2EQ-X4X1-M1(T)J
E2EQ-X3D1
E2EQ-X3D1-M1(T)GJ
E2EQ-X8X1
E2EQ-X8X1-M1(T)J
E2EQ-X7D1
E2EQ-X7D1-M1(T)GJ
E2EQ-X15X1
E2EQ-X15X1-M1(T)J
E2EQ-X10D1
E2EQ-X10D1-M1(T)GJ
Item
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page
4.)
Power supply voltage
(operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Indicators Operation indicator (red), Setting indicator (green)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Materials
Case Fluororesin coating (Base material: brass)
Sensing surface Fluororesin
Clamping nuts Fluororesin coating (Base material: brass)
Toothed washer Zinc-plated iron
Accessories Instruction manual
4
E2EQ
Engineering Data (Reference Value)
Sensing Area
E2EQ-X@X@(-M1(T)J) Shielded Models E2EQ-X@D@(-M1(T)GJ)
Influence of Sensing Object Size and Material
E2EQ-X4X1(-M1(T)J) E2EQ-X8X1(-M1(T)J) E2EQ-X15X1(-M1(T)J)
E2EQ-X3D1(-M1(T)GJ) E2EQ-X7D1(-M1(T)GJ) E2EQ-X10D1(-M1(T)GJ)
Y
X
5101520
18
16
14
12
10
8
6
4
2
0
20151050
E2EQ-X4X
E2EQ-X8X
E2EQ-X15X
Distance X (mm)
Distance Y (mm)
Y
X
2
4
E2EQ-X3D1 E2EQ-X7D1
20161284048121620
6
8
10
E2EQ-X10D1
Distance X (mm)
Distance Y
(mm)
E2EQ-X10D1 Sensing Head
E2EQ-X7D1 Sensing Head
E2EQ-X3D1 Sensing Head
50
5
4
3
2
1
X
353025201510
d ×
d t = 1 mm
Distance X (mm)
Side length of sensing object: d (mm)
Stainless steel
(SUS304)
Iron
Brass
Copper
0 10 20 30 40 50
10
8
6
4
2
X
d ×
d t = 1 mm
Distance X (mm)
Side length of sensing object: d (mm)
Iron
Brass
Copper
Stainless steel
(SUS304)
20100
20
16
12
8
4
X
807060504030
d ×
d t = 1 mm
Side len
g
th of sensin
g
object: d (mm)
Distance X (mm)
Stainless steel
(SUS304)
Iron
Brass
Aluminum
Copper
1050
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
X
3530252015
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Distance X (mm)
Aluminum
Stainless steel
(SUS304)
Iron
Copper
Brass
510150
10
9
8
7
6
5
4
3
2
1
X
20 25 30 35 40 45
d ×
d t = 1
mm
Side length of sensing object: d (mm)
Distance X (mm)
Aluminum
Iron
Copper
Brass
Stainless steel
(SUS304)
20151050
14
12
10
8
6
4
2
X
35 55504030 4525
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Distance X (mm)
Aluminum
Stainless steel
(SUS304)
Iron
Copper
Brass
E2EQ
5
I/O Circuit Diagrams
Long Sensing-distance Models
Standard Models
Residual Output Voltage Leakage Current
E2EQ-X@X@(-M1(T)J) E2EQ-X@D@(-M1(T)GJ) E2EQ-X@D
Model Operation
mode Timing Chart Output circuit
E2EQ-X4X1
E2EQ-X8X1
E2EQ-X15X1
E2EQ-X4X1-M1(T)J
E2EQ-X8X1-M1(T)J
E2EQ-X15X1-M1(T)J
NO
5
4
3
2
1
01 3 5 10 30 50 100
Load current (mA)
Residual output voltage (V)
31
5
4
3
2
1
0
1,000500300
1005030105
Load current (mA)
Residual output voltage (V)
20100
1.5
1.0
0.5
E2EQ-X7D1
4030
E2EQ-X10D1
E2EQ-X3D1
Leakage current (mA)
Power supply voltage (V)
0
80 (TYP)
100
(%)
Sensing
object
Rated
sensing
distance
Stable sensing areaNon-sensing area
Unstable
sensing
area
Set position
ON
OFF
ON
OFF
ON
OFF
Setting indicator
(green)
Operation indicator
(red)
Control output
0 V
+V
4
2
1
3
3
4
Note 1. The load can be connected to either the +V or
0 V side.
Note 2. There is no polarity. Therefore, the brown and
blue lines have no polarity.
Brown
Blue
Proximity
Sensor
main
circuit
Load
Connector Pin Arrangement
Note: Pins 1 and 2 are not used.
Model Operation
mode Timing Chart Output circuit
E2EQ-X3D1
E2EQ-X7D1
E2EQ-X10D1
E2EQ-X3D1-M1(T)GJ
E2EQ-X7D1-M1(T)GJ
E2EQ-X10D1-M1(T)GJ
NO
80 (TYP) 0100(%)
Sensing
object
Rated
sensing
distance
Stable sensing areaNon-sensing area
Unstable
sensing
area
Set position
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
Setting indicator
(green)
Operation
indicator (red)
Control output
0 V
+V
4
1
42
3
1
Connector Pin Arrangement
Note: Pins 2 and 3 are not used.
Note: The load can be connected to either the +V
or 0 V side.
Load
Brown
Blue
Proximity
Sensor
main
circuit
6
E2EQ
Pre-wired Connector Model Connections
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use this product under ambient conditions that exceed the
ratings.
Design
Influence of Surrounding Metal
When mounting the Sensor within a metal panel, ensure that the
clearances given in the following table are maintained. Failure to
maintain these distances may cause deterioration in the performance
of the Sensor.
Influence of Surrounding Metal (Unit: mm)
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.
Mutual Interference (Unit: mm)
Mounting
Do not tighten the nut with excessive force. A washer must be used
with the nut.
Note: 1. The allowable tightening strength depends on the distance from the
edge of the head, as shown in the following table. (A is the distance
from the edge of the head. B includes the nut on the head side. If the
edge of the nut is in part A, the tightening torque for part A applies
instead.)
2. The following torque assume washers are being used.
Model E2EQ-X@X1-M1(T)J E2EQ-X@D1-M1(T)GJ
Connections
4
3
2
1
4
3
2
1
Main
circuit
Brown
(not used)
Black (+)
Blue ()
Pre-wired Connector
Model
E2EQ-X@X1-M1J
Sensor I/O Connector
XS2F-D42@-@C0-F
4
3
2
1
4
3
2
1Brown (+)
Blue ()
Pre-wired Connector
Model
E2EQ-X@D1-M1GJ
Sensor I/O Connector
XS2F-D42@-@A0-F
Main
circuit
4
3
2
1
4
3
2
1
Main
circuit
Brown (not used)
White (not used)
Black (+)
Blue ()
Pre-wired Connector
Model
E2EQ-X@X1-M1TJ
Sensor I/O Connector
XS5F-D421-@80-F
4
3
2
1
4
3
2
1Brown (+)
White (not used)
Blue (not used)
Black ()
Pre-wired Connector
Model
E2EQ-X@D1-M1TGJ
Sensor I/O Connector
XS5F-D421-@80-F
Main
circuit
WARNING
Precautions for Correct Use
Model Item l d D m n
E2EQ-X4X1(-M1(T)J) 2.4 18 2.4 12 18
E2EQ-X8X1(-M1(T)J) 3.6 27 3.6 24 27
E2EQ-X15X1(-M1(T)J) 64564545
E2EQ-X3D1(-M1(T)GJ)
0
12
0
818
E2EQ-X7D1(-M1(T)GJ) 18 20 27
E2EQ-X10D1(-M1(T)GJ) 30 40 45
l
m
n
mD
d dia.
l
Model Item A B
E2EQ-X4X1(-M1(T)J) 30 20
E2EQ-X8X1(-M1(T)J) 60 35
E2EQ-X15X1(-M1(T)J) 110 90
E2EQ-X3D1(-M1(T)GJ) 30 20
E2EQ-X7D1(-M1(T)GJ) 50 35
E2EQ-X10D1(-M1(T)GJ) 100 70
Torque Part A Part B
Model Dimension
(mm) Torque Torque
E2EQ-X4X1(-M1(T)J)
---
30 N·m
E2EQ-X8X1(-M1(T)J) 70 N·m
E2EQ-X15X1(-M1(T)J) 180 N·m
E2EQ-X3D1(-M1(T)GJ) 24 15 N·m ---
E2EQ-X7D1(-M1(T)GJ) 29
E2EQ-X10D1(-M1(T)GJ) 26 39 N·m 78 N·m
A
B
Part B Part A
Shielded Model
E2EQ
7
Dimensions
Pre-wired Models
Long Sensing-distance Models
Standard Models
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
38 9
2
10
33
17 4
21 dia.
*1
M12 × 1Indicators *2
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Flame-resistant,
Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm),
Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X4X1
E2EQ-X8X1
43 12
2
10
38
24 4
29 dia.
*1
M18 × 1
*1. 6-dia. vinyl-insulated round cable with 2 conductors
(Flame-resistant, Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
*2. Operation indicator (red), Setting indicator (green)
Indicators *2
Two clamping nuts
Toothed washer
48 12
3
10
43
36 5
42 dia.
*1
M30 × 1.5
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Flame-resistant,
Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. Operation indicator (red), Setting indicator (green)
Indicators *2
Two clamping nuts
Toothed washer
E2EQ-X15X1
38
27.6
24
21 dia.
17 5
M12 × 14
Two toothed washers
Indicators *2 *1
Two clamping nuts (fluororesin coated)
*1. 6-dia. vinyl-insulated round cable with 2 conductors
(Flame-resistant, Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal
conduit).
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X3D1
47
32
29
6
29 dia.
24
M18 × 14
*1
Two toothed washers
Indicators *2
Two clamping nuts (fluororesin coated)
*1. 6-dia. vinyl-insulated round cable with 2 conductors
(Flame-resistant, Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal
conduit).
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X7D1
56
42
38
36
42 dia.
10
*1
M30 × 1.5 5Two toothed washers
Indicators *2
Two clamping nuts (fluororesin coated)
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Flame-resistant,
Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X10D1
8
E2EQ
Pre-wired Connector Models
Long Sensing-distance Models
Standard Models
938
33
10
2
4
17
21 dia.
1* M12 × 1
M12 × 1
Two clamping nuts
Toothed
washer
Indicators *2
*1. 4-dia. vinyl-insulated round cable (Flame-resistant,
Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 300 mm
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X4X1-M1(T)J
2
1243
38
10424
29 dia.
*1
M12 × 1
M18 × 1
*1. 6-dia. vinyl-insulated round cable (Flame-resistant,
Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 300 mm
*2. Operation indicator (red), Setting indicator (green)
Indicators *2
Two clamping nuts
Toothed
washer
E2EQ-X8X1-M1(T)J
36
1248
43
510
3
42 dia.
1*
M12 × 1
M30 × 1.5
*1. 6-dia. vinyl-insulated round cable (Flame-resistant,
Conductor cross section: 0.5 mm2, Insulator
diameter: 1.9 mm), Standard length: 300 mm
*2. Operation indicator (red), Setting indicator (green)
Indicators *2
Two clamping nuts
Toothed
washer
E2EQ-X15X1-M1(T)J
E2EQ-X3D1-M1(T)GJ
38
27.6
24
17
21 dia.
5
M12 × 14
*1
Two toothed washers
Indicators *2
Two clamping nuts (fluororesin coated) M12 × 1
(aluminum)
*1. 6-dia. vinyl-insulated round cable (flame-resistant),
Standard length: 300 mm
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X7D1-M1(T)GJ
47
32
29
24
29 dia.
6
M18 × 14
*1
Indicators *2
Two toothed washers
Two clamping nuts (fluororesin coated)
M12 × 1 (aluminum)
*1. 6-dia. vinyl-insulated round cable (flame-
resistant), Standard length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
E2EQ-X10D1-M1(T)GJ
56
42
38
10
36
42 dia.
M30 × 1.5 5
*1
Two toothed washers
Two clamping nuts (fluororesin coated)
Indicators*2
M12 × 1 (aluminum)
*1. 6-dia. vinyl-insulated round cable
(flame-resistant), Standard
length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
Mounting Hole Dimensions
F
Model E2EQ-X4X@
E2EQ-X3@E2EQ-X8X@
E2EQ-X7@E2EQ-X15X@
E2EQ-X10@
F (mm) 12.5 dia. 18.5 dia. 30.5 dia.
+0.5
0
+0.5
0
+0.5
0
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omrons representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.1
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
E2EQ-X10D1G-M1GJ-T 0.3M E2EQ-X10D1-M1J-1 0.3M E2EQ-X10D2R-M1GJ-T4 0.3M E2EQ-X15X1 2M E2EQ-
X3D1G-M1GJ-T 0.3M E2EQ-X3D1-M1J-1 E2EQ-X7D1G-M1GJ-T 0.3M E2EQ-X15X1 5M E2EQ-X3D1-M1J 0.3M
E2EQ-X7D1-M1J 0.3M E2EQ-X10D1G-M1TGJ-T-US 0.3M E2EQ-X10D2R-M1TGJ-T4-US 0.3M E2EQ-X3D1G-
M1TGJ-T-US 0.3M E2EQ-X7D1G-M1TGJ-T-US 0.3M E2EQ-X7D1-M1J-1 0.3M E2EQ-X3D1G-M1TGJ-T 0.3M