Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
DSP
ASCTB180E 201202-T
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
Characteristics Item Specifications
Contact Arrangement 1 Form A 1 Form A 1 Form B 2 Form A
Contact resistance (Initial) Max. 30 mΩ (By voltage drop 6 V DC 1A)
Contact material Au-flashed AgSnO2 type
Rating
Nominal switching capacity (resistive load) 8 A 250 V AC, 5A 30V DC 5 A 250 V AC, 5 A 30 V DC
Max. switching power (resistive load) 2,000 VA, 150 W 1,250 VA, 150 W
Max. switching voltage 250 V AC, 125 V DC
Max. switching current 8 A AC, 5 A DC 5 A AC, DC
Nominal operating power 300 mW
Min. switching capacity (Reference value)*110m A 5 V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdo wn voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact sets 2,000 Vrms (1 Form A 1 Form B, 2 Form A) (Detection current: 10mA.)
Between contact and coil 3,000 Vr ms for 1min. (Detection current: 10mA.)
Surge breakdown
voltage*2between contacts and coil 5,000 V
Temperature rise (coil) (at 65°C 149°F)Max. 55°CMax. 40°CMax. 55°C
Operate time [Set time] (at 20°C 68°F)Max. 10 ms [10 ms] (Nominal coil voltage applied to the coil, e xcluding contact bounce time .)
Release time [Reset time] (at 20°C 68°F)Max. 5 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock resistance Functional Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Destructive Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 2 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 3.5 mm
Expected life Mechanical Min. 5×107 (at 180 times/min.)
Electrical Min. 105 (resistive load)
Conditions
Conditions for operation, transport and storage*3
(Not freezing and condensing at low temperature)
Ambient temperature:
–40°C to +60°C
–40°F to +140°F
Ambient temperature:
–40°C to +65°C
–40°F to +149°F
Ambient temperature:
–40°C to +60°C
–40°F to +140°F
Solder heating 250°C 482°F (10s), 300°C 572°F (5s), 350°C 662°F (3s)
(Soldering depth: 2/3 terminal pitch)
Max. operating speed 3 cps
Unit weight Approx. 4.5 g .16 oz
1. Max. switching capacity 2.-(1) Life curve (1 Form A 1 Form B) 2.-(2) Life curve (1 Form A 1 Form B)
10
0.1 100 1000
Contact voltage, V
Contact current, V
1
10
DC resistive
load (1a)
DC resistive load
(1a1b,2a)
AC resistive
load (1a)
AC resistive
load
(1a1b,2a)
100
10
012 43765
Switching capacity, A
No. of operations, ×104
265 V·130 V AC cosϕ = 1
265 V·130 V AC
cosϕ = 0.4
100
50
10
0.5 1 105
Switching capacity, A
No. of operations, ×104
30 V DC L/R = 7 ms
30 V DC resistive
3.-(1) Coil temperature rise (1 Form A)
Tested sample: DSP1a-DC12V, 5 pcs. 3.-(2) Coil temperature rise
(1 Form A 1 Form B)
Tested sample: DSP1-DC12V, 5 pcs.
3.-(3) Coil temperature rise (2 Form A)
Tested sample: DSP2a-DC12V, 5 pcs.
50
60
40
10
20
30
080 100 120
8A
0A
Coil applied voltage, %V
Coil temperature rise, °C
50
60
40
10
20
30
080 100 120
5A
0A
Coil applied voltage, %V
Coil temperature rise, °C
50
60
40
10
20
30
080 100 120
5A
0A
Coil applied voltage, %V
Coil temperature rise, °C