MODEL
LEA100F-3R3-Y
LEA100F-5 LEA100F-9
LEA100F-12 LEA100F-15 LEA100F-18 LEA100F-24
LEA100F-24-H
LEA100F-30 LEA100F-48
MAX OUTPUT WATTAGE[W] 66 100 103.5 102 100.5 100.8 103.2 103.2 105 105.6
DC OUTPUT
*5
3.3V 20A 5V 20A 9V 11.5A 12V 8.5A 15V 6.7A 18V 5.6A 24V 4.3A
24V 4.3(5.0)A
30V 3.5A 48V 2.2A
SPECIFICATIONS
MODEL
LEA100F-3R3-Y
LEA100F-5 LEA100F-9
LEA100F-12 LEA100F-15 LEA100F-18 LEA100F-24
LEA100F-24-H
LEA100F-30 LEA100F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120 - 370
CURRENT[A]
ACIN 100V
1.0 1.4typ
ACIN 200V
0.5 0.7typ
FREQUENCY[Hz] 50/60 (47-63
)or DC
EFFICIENCY[%]
ACIN 100V
71typ 75typ 79typ 79typ 79typ 81typ 81typ 81typ 82typ 83typ
ACIN 200V
73typ 78typ 81typ 81typ 82typ 83typ 84typ 84typ 85typ 85typ
POWER FACTOR
ACIN 100V
0.98typ 0.99typ
ACIN 200V
0.92typ 0.94typ
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)(
At cold start)(
Ta=25C)
ACIN 200V
30typ (Io=100%)(
At cold start)(
Ta=25C)
LEAKAGE CURRENT[mA] 0.75max (60Hz,According to IEC60950 and DEN-AN)
OUTPUT
VOLTAGE[V] 3.3 5 9 12 15 18 24 24 30 48
CURRENT[A]
*1
20 20 11.5 8.5 6.7 5.6 4.3
4.3 (Peak 5.0)
3.5 2.2
LINE REGULATION[mV] 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 120max 150max 150max 180max 300max
RIPPLE[mVp-p]
0to+50
C
*2
80max 80max 120max 120max 120max 120max 120max 120max 120max 150max
-10-0
C
*2
140max 140max 160max 160max 160max 160max 160max 160max 160max 200max
RIPPLE NOISE[mVp-p]
0to+50
C
*2
120max 120max 150max 150max 150max 150max 150max 150max 150max 350max
-10-0
C
*2
160max 160max 180max 180max 180max 180max 180max 180max 180max 400max
TEMPERATURE REGULATION[mV]
0to+50
C
50max 50max 90max 120max 150max 180max 240max 240max 300max 480max
-10 to +50C
60max 60max 120max 150max 180max 200max 290max 290max 360max 600max
DRIFT[mV]
*3
20max 20max 36max 48max 60max 72max 96max 96max 120max 192max
START-UP TIME[ms] 500max (ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 20typ (Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as optional:t10%)
OUTPUT VOLTAGE SETTING[V]
3.25 - 3.35 4.9 - 5.3 8.6 - 9.4 11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 28.5 - 31.5 46.0 - 50.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rating (works over 105% of peak current at option -H)and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V
Works at 115 - 140% of rating
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Option (Refer to Instruction Manual)
ISOLATION
INPUT-OUTPUT-RC
*4
AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-FG
*4
AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC
*4
AC100V 1minute,Cutoff current = 100mA,DC100V 10MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +70C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,C-UL,EN60950-1,EN60065,EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
CONDUCTED NOISE Complies with FCC-B,CISPR22-B,EN55022-B,VCCI-B
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 62X35X222mm (WXHXD)/380g max (without chassis and cover)
COOLING METHOD Convection
*1Peak load for 10 sec. or less is acceptable if the total wattage is less than the rated wattage.
*2This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:
RM101).
*3Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*4Applicable when remote control (optional) is added.
*5( ):peak current.
*6Please contact us about safety approvals for the model with option.
*Parallel operation with other model is not possible.
*Derating is required when operated with chassis and cover.
LEA100F
AC-DC Power Supplies Open Frame/Enclosed type
LEA 100 F -5 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *6
C :with Coating
G :Low leakage current
J2:Mini terminal block
R :with Remote ON/OFF
S :with Chassis
SN
:with Chassis & cover
Y :with Potentiometer