ISO 9001 ISO 14001 AS 9100 CERTIFIED
Mini-Circuits
®
P.O. Box 350166, Brooklyn, New York 11235-0003 (718) 934-4500 Fax (718) 332-4661
The Design Engineers Search Engine Provides ACTUAL Data Instantly at
®
Notes: 1. Performance and quality attributes and conditions not expressly stated in this specification sheet are intended to be excluded and do not form a part of this specification sheet. 2. Electrical specifications
and performance data contained herein are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. 3. The parts covered by this specification sheet are subject to
Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard
Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp.
For detailed performance specs
& shopping online see web site
minicircuits.com
IF/RF MICROWAVE COMPONENTS
Maximum Ratings
Typical Performance Data
Frequency
(MHz)
Insertion Loss
(dB)
Low Pass Filter Electrical Specifi cations
Operating Temperature -55°C to 100°C
Storage Temperature -55°C to 100°C
RF Power Input 0.5W max.
Applications
lab use
test equipment
video equipment
Return Loss
(dB)
Frequency
(MHz)
Group Delay
(nsec)
_
xσ
Low Pass Filter
REV. B
M113397
NLP-100+
090820
Coaxial
50 DC to 98 MHz
PASSBAND
(MHz)
fco (MHz)
Nom.
STOPBAND
(MHz)
VSWR
(:1)
(loss < 1 dB) (loss 3 dB) (loss > 20 dB) (loss > 40 dB)
Passband
Typ.
Stopband
Typ.
DC-98 108 146-189 189-400 1.7 18
electrical schematic
INSERTION LOSS
0
20
40
60
80
100
1 10 100 1000
FREQUENCY(MHz)
INSERTION LOSS (dB)
at RF level of 0 dBm
RETURN LOSS
0
10
20
30
40
50
1 10 100 1000
FREQUENCY(MHz)
RETURN LOSS (dB)
at RF level of 0 dBm
GROUP DELAY
0
4
8
12
16
20
0 52 104 156 208 260
FREQUENCY (MHz)
GROUP DELAY (nsec)
at RF level of 0 dBm
typical frequency response
1.00 0.02 0.1 41.6 1.00 7.802
29.50 0.16 0.1 20.2 15.00 7.718
58.00 0.34 0.1 14.4 29.50 7.812
72.00 0.31 0.1 20.3 43.50 7.901
86.50 0.41 0.1 20.2 58.00 8.226
98.00 0.58 0.1 16.8 72.00 9.283
102.00 0.62 0.1 18.4 86.50 10.402
106.00 0.75 0.1 18.3 98.00 12.091
108.00 0.93 0.2 15.0 102.00 13.505
112.00 1.72 0.5 9.3 104.00 14.551
120.00 5.98 1.3 2.5 106.00 15.904
130.01 13.62 1.3 0.6 108.00 16.952
138.02 19.37 1.2 0.3 112.00 18.647
140.02 20.73 1.2 0.3 115.00 18.923
146.02 24.55 1.2 0.2 120.00 16.027
150.03 26.95 1.1 0.1 125.00 11.256
160.03 32.54 1.2 0.1 130.00 8.381
170.04 37.64 1.2 0.1 138.00 6.335
180.04 42.35 1.2 0.1 140.00 5.440
185.04 44.43 1.3 0.0 146.00 5.302
189.05 46.24 1.4 0.0 150.00 4.068
250.07 67.20 3.6 0.1 155.00 3.545
271.58 76.41 8.4 0.1 160.00 3.249
300.08 75.73 6.4 0.1 165.00 3.192
330.08 75.45 3.9 0.1 170.00 1.495
343.07 73.72 2.6 0.1 180.00 9.308
360.08 75.87 4.3 0.1 185.00 2.440
371.58 77.51 9.8 0.1 189.00 1.634
390.08 79.32 7.8 0.1 250.00 1.412
400.08 75.26 2.4 0.1 260.00 1.228
NLP-100+
Outline Drawing
Outline Dimensions ( )
Features
rugged shielded case
other NLP models available with wide selection of
cut-off frequencies Connectors Model Price Qty.
N-Type NLP-100+ $35.95 ea. (1-9)
inch
mm
CASE STYLE: FF57
+ RoHS compliant in accordance
with EU Directive (2002/95/EC)
The +Suffi x has been added in order to identify RoHS
Compliance. See our web site for RoHS Compliance
methodologies and qualifi cations.
R F IN R F OUT
40 dB
20 dB
3 dB
1 dB
F R E QU E NC Y / F co
AT T E NUAT IO N, dB
DC 0.9 1 1.35 1.75 3
B
D
E
.67
2.90
.82
grams
17.02 73.66 20.83
90.0
Permanent damage may occur if any of these limits are exceeded.