www.clare.com
2R03
PAA190
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Ratings Units
Blocking Voltage 400 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
Isolation Voltage, Input to Output 5000 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Electrical Characteristics @ 25ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current *
Continuous, AC/DC Configuration - IL- - 150 mA
Peak t=10ms ILPK - - 400
On-Resistance, AC/DC Configuration IL=150mA RON --22Ω
Off-State Leakage Current VL=400VPILEAK --1µA
Switching Speeds
Turn-On IF=5mA, VL=10V ton --1
ms
Turn-Off toff - - 0.5
Output Capacitance VL=50V, f=1MHz COUT -25-pF
Input Characteristics
Input Control Current IL=150mA IF--5mA
Input Dropout Current - IF0.2 0.7 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics
Capacitance, Input to Output - CI/O -3-pF
*NOTE: If both poles operate simultaneously, then load current must be derated so as not to exceed the package power dissipation value.