OUTPUT SPECIFICATIONS
Voltage adjustability Vout on singles -8%/+16%
+5V output on multiple ±20%
Remote sense ±10%
Line regulation Single outputs ±0.2%
(LL to HL, FL) Multiple: +5V output ±0.2%
Multiple: aux. outputs, Note 5 ±0.5%
Load regulation Single outputs: ±0.2%
(20% to 100% FL) Multiple: +5V output ±1.0%
Multiple: -5V output ±4.0%
Multiple: ±12V, 24V, Note 5 ±2.0%
Cross regulation 5A load step on main output 1.0%
Auxiliary outputs, Note 5
Transient response 25% di/dt 1% max. dev., 1ms recov.
Temperature coefficient Main/single output ±0.02%/°C
Multiple: auxiliary outputs ±0.04%/°C
Overvoltage protection Main/single output 130% ±10% Vout
Output power limit Multiples: 300W Pout
primary power limited
Singles: 105%-120% Iout
current foldback
Short circuit protection All outputs Yes
INPUT SPECIFICATIONS
Input voltage range LX200-46xx models, 175 to 264VAC
See Note 3 (230VAC version)
LX200-76xx models, 98 to 132VAC
autorange version 190 to 264VAC
Drop-out voltage 90VAC
Input frequency 50Hz/60Hz
Input surge current 25A max.
Safety ground 115VAC, 60Hz 1.6mA
leakage current 230VAC, 50Hz 2.5mA
Remote OFF Logic 0 on ROF
LX200 SERIES
Flexible single and muliple outputs
[ 2 YEAR WARRANTY ]
• 200W continuous, 300W peak output power
• Industry standard footprint, low profile
• Conducted noise to meet EN55022 class B
• AC and DC input voltage options in same package
• Efficiency up to 88%
• Optional power sharing/VME signals board
• Autoranging input option
The LX200 series offers 200 Watts of continuous output power in a low profile
industry standard footprint. With two single output options and a flexible
multiple output version, the series can address most power requirements as
standard. The design is specifically tailored to allow full flexibility and
modifications to meet customer applications can be implemented with relative
ease. The LX200 AC input series meets the safety requirements of EN60950,
VDE0805, UL1950 and CSA C22.2 No. 950. Input conducted noise levels meet
the requirements of FCC and EN55022 class B. LX200 series power supplies
are ideal for use in applications such as point-of-sale equipment, central and
public telecom power systems and network equipment.
SPECIFICATION
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
PAGE 1
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS
Conducted emissions EN55022, level A
Radiated emissions EN55022, level B
ESD air EN61000-4-2, level 3 Perf. criteria 1
ESD contact EN61000-4-2, level 4 Perf. criteria 1
Surge EN61000-4-5, level 3 Perf. criteria 1
Fast transients EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 2
Conducted immunity EN61000-4-6, level 3 Perf. criteria 2
GENERAL SPECIFICATIONS
Hold-up time 110/230VAC 28ms
Efficiency 82% min.
Isolation voltage Input/output 3000VAC
Input/chassis 1500VAC
Switching frequency Fixed 44kHz
Approvals and EN60950, VDE0805, UL1950
standards See Note 7 CSA C22.2 No. 950
Weight 1.3kg (46oz)
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating 0°C to +70°C
Non-operating –25°C to +85°C
0°C to +40°C ambient, 200W
convection cooled
40°C to 70°C ambient, Derate linearly
convection cooled to 25% full load
Peak (0°C to 40°C, max. 10s) 300W
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non-operating 30,000 feet max.
Vibration Operating, 5–50Hz 0.05mm pk-pk
Operating, 50–100Hz 0.025mm pk-pk
Non-operating 100mm drop on
chassis face
OVERLOAD/SHORT CIRCUIT PROTECTION
The overload/short circuit protection mechanisms are different for the single
output models and the multiple output model.
The single output models will current limit when the output load reaches
105-120% of maximum load during overload or short circuit conditions.
The unit will operate in a constant current mode making the single output
models suitable for battery charging applications.
The multiple output model uses a power limiting function. When the total
output power reaches 300W the outputs will foldback to the values detailed
below:
Output Foldback Value
+5V 15A continuous
+12V 4A continuous
+24V 2A continuous
–5V/–12V Protected by 4A Multi Fuse™
The outputs will not foldback until the total output power exceeds the maxi-
mum power limits. This allows the units to have a peak power capability
but it requires that care must be taken not to permanently overload any
individual output. The +5V, +12V and +24V outputs are not individually pro-
tected and it is recommended that the maximum continuous load does not
exceed the value given in the output specifications. The -5V and -12V out-
puts are individually protected by a 4A Multi Fuse™ and the maximum con-
tinuous load should not exceed the value given in the output specifications.
OUTPUT OUTPUT CURRENTS RIPPLE MODEL NUMBER (3)
VOLTAGE MAX (1) PEAK (2) RMS PK-PK 230VAC AUTORANGE
+5.0V 20.0A 40.0A 0.2% 2.0% LX200-4620 LX200-7620
–5.0V 4.0A 10.0A 0.2% 2.0%
–12.0V 4.0A 10.0A 0.2% 2.0%
+12.0V 8.0A 20.0A 0.2% 2.0%
+24.0V 4.0A 10.0A 0.2% 2.0%
24.0V (4) 9.0A 0.1% 1.0% LX200-4624 LX200-7624
48.0V (4) 4.5A 0.1% 1.0% LX200-4617 LX200-7617
Notes
1 The multiple output LX200 has a continuous output power rating of 200W.
The single-output versions have a continuous output power rating of
216W.
2 Peak power figures for individual outputs on the multiple output unit are
for less than 10 seconds duration. The overall peak power for the unit is
300W for 10 seconds duration.
3 The LX200 is available with a standard 230VAC input operation (order
LX200-46xx) or the input board can be fitted with an autorange circuit
which automatically senses the input voltage and switches to the
appropriate voltage range (order LX200-76xx).
4 Single output models are adjustable -8%, +16%.
5 A 10% load on the main output is necessary to maintain regulation on the
auxiliaries at full load (multiple output model).
6 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
7 Consideration should be given to measuring the temperature on the main
transformer (T1) when the power supply is installed in end-use equipment.
The measured temperature on T1 must not exceed 90°C. For further
information on the LX200 safety approvals, contact Computer Products.
Options
DC input models for 24V and 48V operation are detailed on the LX200,
LX350 and LX550 series DC/DC converter data sheet on page 170.
A cover and signals board are available as options. To order, add the
suffixes ‘-C’, ‘-S’ respectively, see table below.
SIGNALS (OPTIONAL)
An optional signals board supplies the following VME utility bus signals:
ACF (AC Fail) Logic 1 to 0 transition occurs >10ms before outputs fall
below 80%-85% of nominal in the event of input failure.
DCF (DC Fail) Logic 0 occurs if output falls below 85%–95% of nominal.
SRS (System Reset) Logic 1 for system OK (AC and DC good and reset
times [200ms])
PM Power Monitor signal, proportional to the output power, ratio of
20mV/W ±10%.
PS Power Share connections, to be joined for parallel operation of two
or more units, ensuring equal power share. For power share
operation unit outputs need to be set to ±5% of each other and
should be connected in star configurations with the load as star
centre.
OPTIONS SUFFIX EXAMPLE
None LX200-76xx
Cover -C LX200-76xx-C
Signals -S LX200-76xx-S
Cover and Signals -C-S LX200-76xx-C-S
PIN CONNECTIONS
PIN NO INPUT MULTI O/P SINGLE O/P SIGNALS
1 Earth PS PS SRS
2 N/C ACF ACF ACF
3 Neutral SRS SRS DCF
4 N/C ROF ROF PM
5 Live +5VS 0VS PS
6 N/C +5V 0V ROF
7 115V +5V 0V +VS
8 Link +5V 0V 0V
9 N/C 0V 0V
10 N/C 0V 0V
11 N/C 0V +Vout
12 N/C –5V +Vout
13 N/C –12V +Vout
14 N/C +12V +Vout
15 N/C +24V +VS
200 Watt
AC/DC universal input switch mode power supplies
AC/DC POWER SUPPLIES |
200W AC
PAGE 2
http://www.artesyn.com
SIGNALS
1 8
AA
AA
A
115
115
ALL DIMENSIONS IN INCHES (mm)
AA
AA
1.25
(31.75) 1.25
(31.75)
INPUT SYSTEM
O. K. LED OUTPUT
A
9.18 (233.2)
7.15 (181.6)
1.02
(25.9)
8.52 (216.4)
.42
(10.7)
2.06
(52.4)
6.27 (159.3)
0.83
(21)
2.05
(52)
0.59
(15)
Mechanical notes
A Input and output connectors are 15 way terminal block, 5mm pitch.
Signals board option is 8 way, single row right angle 0.1”, Molex
910210128, this mates with 90147 1108 or equivalent.
B Customer fixing screws (A) are M3 isometric. They must not penetrate into
unit by more than 5mm.
International Safety Standard Approvals
Multiple output and 24V Single output units are approved to these
standards. Safety approval pending for 48V output model. See Note 7
EN60950/VDE0805 Reg. File No. 90371
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C/LR101320
50W
200W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
DERATING CURVE (See Notes 1 & 2)
Output Power (Watts)
NATURAL
CONVECTION
COOLING
10% MIN. LOAD FOR AUXILIARY REGULATION
0W
300W
PEAK OUTPUT
POWER
200 Watt
AC/DC universal input switch mode power supplies
AC/DC POWER SUPPLIES |
200W AC
PAGE 3
PAGE 4
http://www.artesyn.com
DS_LX200AC_19980401.PDF
Data Sheet © Artesyn Technologies
®
2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.