1
General-purpose Relay MY
An Improved Miniature Power Relay
with Many Models for Sequence Control
and Power Applications
A
wide range of relay variations including ones with
operation indicators, high-capacity capability,
built-in diodes, etc.
Arc barrier standard on 3- and 4-pole relays.
Withstand voltage: 2,000 VAC.
Ordering Information
Type Contact form
Plug-in socket/solder terminals
PCB terminals
Upper-mounting/
solder terminals
W
ith indicator
Standard SPDT *MY1 ––– *MY1-02 MY1F
DPDT MY2 MY2N MY2-02 MY2F
DPDT (bifurcated)
MY2Z MY2ZN MY2Z-02 MY2ZF
3PDT MY3 MY3N MY3-02 MY3F
4PDT MY4 MY4N MY4-02 MY4F
4PDT (bifurcated)
MY4Z MY4ZN MY4Z-02 MY4ZF
W
ith built-in diode
DPDT MY2-D MY2N-D2 –––** –––
(DC only)
DPDT (bifurcated)
MY2Z-D MY2ZN-D2 ––– –––
3PDT MY3-D MY3N-D2 ––– –––
4PDT MY4-D MY4N-D2 ––– –––
4PDT (bifurcated)
MY4Z-D MY4ZN-D2 ––– –––
With built-in CR DPDT MY2-CR MY2N-CR –––
Not available.
(AC only)
DPDT (bifurcated)
MY2Z-CR ––– –––
3PDT MY3-CR ––– –––
4PDT MY4-CR MY4N-CR –––
4PDT (bifurcated)
MY4Z-CR ––– –––
W
ith test button
DPDT MY2I4 MY2I4N ––– –––
4PDT MY4I4 MY4I4N ––– –––
MY MY
2
Type Upper-mounting/
solder terminals
PCB terminals
Plug-in socket/solder terminals
Contact form
W
ith indicator
High-humidity DPDT MY2-TU ––– ––– –––
DPDT (bifurcated)
MY2Z-TU ––– ––– –––
3PDT MY3-TU ––– ––– –––
4PDT MY4-TU MY4N-TU ––– –––
4PDT (bifurcated)
MY4Z-TU ––– –––
Not available.
High-capacity (7 A)
DPDT MY2-Y MY2N-Y –––
High-sensitivity 3PDT MYC3
Not available
MYC3-02
Rated coil voltage
Note: 1.
When ordering, add the rated coil voltage to the model number
. Rated coil voltages are given in the coil ratings table.
Example: MY2, 6 V
AC
*2.
Models mark with an asterisk are not available with international safety standard ratings.
3.
Add “-G” to the model number if mounting studs are required (e.g., MY4-G).
4.
The standard contacts for MY2Z-series Relays and for the MY4Z are gold-plated.
**5.
Models denoted by “–––” will be manufactured upon request. Ask your OMRON representative.
6.
The following variations are also available.
Plastic-sealed relays (MYQ4):
See page 46.
Latching relays (MY2K):
See page 51.
Hermetically sealed relays (MY4H):
Ask your OMRON representative.
Accessories (Order Separately)
Sockets
Poles Front-mounting
socket
Back-mounting socket
(DIN-rail/screw mounting)
Solder terminals
W
ire-wrap terminals
PCB
W/ clip
W/o clip
W/ clip
W/o clip
terminals
1 or 2
PYF08A-E, PYF08A,
PYF08A-N (finger protection)
PY08 PY08-Y1 PY08QN PY08QN-Y1 PY08–02
3PYF1
1A-E, PYF1
1A PY11 PY11-Y1 PY11QN PY11QN-Y1 PY11-02
4
PYF14A-E, PYF14A
PYF14A-N (finger protection)
PY14
PY14-3* PY14-Y1 PY14QN PY14QN-Y1 PY14-02
Note: *1.
Equipped with operation check terminal.
2.
The PYF08A(-E), PYF1
1A(-E), and PYF14A(-E) have been approved as individual sockets by UL S08 and CSA C22.2.
Mounting Plates for Sockets
Socket
model For 1 socket
For 18 sockets For 36 sockets
PY08, PY1
1, PY14, PY08QN(2),
PY11QN(2), PY14QN(2) PYP-1 PYP-18 PYP-36
Note:
PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of sockets.
MY MY
3
Socket Hold-down Clip Pairing
Relay
type
Poles Front-connecting
sockets
Back-connecting sockets
(rail-/screw-mounted) Solder/wire-wrap
terminals
PCB
terminals
Socket Clip Socket Clip Socket Clip
Standard, bifurcated contacts, operation
indicator
, built-in diode, high-capacity
,
high-sensitivity
, or high-humidity
1, 2
PYF08A-N,
PYF08A-E,
PYF08A
PYC-A1 PY08(QN) PYC-P PY08(QN) PYC-P
gy
,g y
3 PYF11A PY11(QN) PY11(QN)
4 PYF14A-N,
PYF14A-E,
PYF14A
PY14(QN) PY14(QN)
MY2N-D4 4 PYF14A-N,
PYF14A-E,
PYF14A
Y92H-3 PY14(QN) PYC-1 PY08(QN) PYC-1
T
est button
1, 2
PYF08A-N,
PYF08A-E,
PYF08A
PYC-A1 PY08(QN) PYC-P2 PY08(QN) PYC-P2
3 PYF11A PY11(QN) PY11(QN)
4 PYF14A-N,
PYF14A-E,
PYF14A
PY14(QN) PY14(QN)
CR circuit
1, 2
PYF08A-N,
PYF08A-E,
PYF08A
Y92H-3 PY08(QN) PYC-1 PY08(QN) PYC-1
3 PYF11A PY11(QN) PY11(QN)
4 PYF14A-N,
PYF14A-E,
PYF14A
PY14(QN) PY14(QN)
Specifications
Coil Ratings
Rated
voltage
Rated current
Coil
resistance Inductance
(reference value)
Must
operate Must
release Max.
voltage Power
consum.
(A )
50 Hz 60 Hz
resistance
Arm.
OFF Arm. ON
% of rated voltage
consum.
(Approx.)
AC
6 V
214.1 mA
183 mA
12.2
0.04 H 0.08 H
80% 30% 110%
1.0 to
12V
A
12 V
106.5 mA
91 mA
46
0.17 H 0.33 H
max. min.
1.2 V
A
(60 Hz)
24 V
53.8 mA
46 mA
180
0.69 H 1.30 H
(60
H
z
)
50 V
25.7 mA
22 mA
788
3.22 H 5.66 H
100/1
10 V
1
1.7/12.9 mA
10/1
1 mA
3,750
14.54 H
24.6 H
0.9 to
11V
A
1
10/120 V 9.9/10.8 mA 8.4/9.2 mA
4,430
19.20 H
32.1 H
1.1 V
A
(60 Hz)
200/220 V
6.2/6.8 mA 5.3/5.8 mA
12,950
54.75 H 94.07 H
(60
H
z
)
220/240 V
4.8/5.3 mA 4.2/4.6 mA
18,790
83.50 H
136.40 H
DC
6 V
150 mA
40
0.17 H 0.33 H
10%
0.9 W
12 V
75 mA
160
0.73 H 1.37 H
min.
24 V
36.9 mA
650
3.20 H 5.72 H
48 V
18.5 mA
2,600
10.60 H 21.00 H
100/1
10 V
9.1/10 mA
1
1,000
45.60 H 86.20 H
Note:
See notes under next table on next page.
MY MY
4
High-sensitivity Relays
Power
supply ratings
Input ratings
Voltage Current Coil
resistance Max.
voltage*
Power consum.
Input
voltage Must
operate Must
release Power
consum.
% of rated voltage
24 VDC
36.9 mA
650 W
110%
Approx. 900 mW
2 to 12 V
2 V max.
1 V min. 0.5 to 52 mW
Note: 1. The
rated current and coil resistance are measured at a coil temperature of 23
°
C with tolerances
of +15%/–20% for rated currents
and
±
15% for DC coil resistance.
2.
Performance characteristic data are measured at a coil temperatures of 23
°C.
3.
The must operate and must release voltages for High-sensitivity Relays was measured at the rated power supply voltage.
4.
AC coil resistance and impedance are provided as reference values (at 60 Hz).
5. Power
consumption drop was measured for the above data. When
driving transistors, check leakage current and connect a bleeder
resistor
if required.
Contact Ratings
Item Single-,
double- or three-pole
Four-pole and High-sensitivity
High-capacity
Resistive load
(cosf
= 1)
Inductive load
(cosf
=0.4,
L/R=7 ms)
Resistive load
(cosf
= 1)
Inductive load
(cosf
=0.4,
L/R=7 ms)
Resistive load
(cosf
= 1)
Inductive load
(cosf
=0.4,
L/R=7 ms)
Rated load
5 A, 220 V
AC
5 A, 24 VDC
2 A, 220 V
AC
2 A, 24 VDC
3 A, 220 V
AC
3 A, 24 VDC
0.8 A, 220 V
AC)
1.5 A, 24 VDC
7 A, 220 V
AC
7 A, 24 VDC
3.5 A, 220 V
AC
3.5 A, 24 VDC
Carry
current
5 A 3 A 7 A
Max.
switching
voltage
250 V
AC
125 VDC
250 V
AC
125 VDC
250 V
AC
125 VDC
Max.
switching
current
5 A 5 A 3 A 3 A 7 A 7 A
Max.
switching
capacity
1,100 V
A
120 W
440 V
A
48 W
660 V
A
72 W
176 V
A
36 W
1,540 V
A
168 W
770 V
A
84 W
Min.
permissible
load*
Standard type: 100 mA, 5 VDC
Bifurcated type: 100
µA, 1 VDC
Standard and high sensitivity types: 1
mA, 1 VDC
Bifurcated type: 100
µA, 1 VDC
–––
*Note:
P level:
λ60
= 0.1 x 10
-6
/operation, reference value
Characteristics
Item All
relays but High-sensitivity Relays High-sensitivity Relays
Contact resistance
50 m
max.
Operate time
20 ms max.
Release time
20 ms max.
Max. operating frequency
Mechanical:
18,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
min. (at 500 VDC)
Dielectric withstand voltage
2,000 V
AC, 50/60 Hz for 1 min (1,000 V
AC
between contacts of same polarity)
1,500 V
AC, 50/60 Hz for 1 min (1,000 V
AC
between contacts of same polarity)
V
ibration resistance
Destruction:
10 to 55 Hz, 1.0-mm double amplitude
Malfunction:
10 to 55 Hz, 1.0-mm double amplitude
Shock resistance
Destruction:
1,000 m/s
2
(approx. 100G)
Malfunction:
200 m/s
2
(approx. 20G)
Life expectancy
See following table.
Ambient operating temperature*
Single- and double-pole standard, bifurcated-contact, test-button, and high-humidity relays:
–55°
C to 70
°
C (with no icing)
All other relays: –55
°
C to 60
°
C (with no icing)
Ambient operating humidity
35% to 85%
Weight
Approx. 85 g
Note:
The values given above are initial values.
MY MY
5
Life Expectancy Characteristics
Relays Mechanical
life
(at 18,000 operations/hr)
Electrical life
(at 1,800 operations/hr under rated load)
Normal, High-humidity
, With test button (except relays
with operation indicator), With CR
AC
50,000,000 operations min.
DC:
100,000,000 operations min.
1-,2-,3-pole:
500,000 operations min.
4-pole:
200,000 operations min.
High-capacity AC
50,000,000 operations min.
DC:
100,000,000 operations min. 500,000 operations min.
With operation indicator or built-in diode
AC
50,000,000 operations min.
DC:
100,000,000 operations min.
1-,2-,3-pole:
500,000 operations min.
4-pole:
200,000 operations min.
With bifurcated contacts
2-pole:
50,000,000 operations min.
4-pole:
20,000,000 operations min.
2-pole:
200,000 operations min.
4-pole:
100,000 operations min.
High-sensitivity
100,000,000 operations min. 200,000 operations min.
Note:
See following tables for real load life expectancies.
Life Expectancies Under Real Loads
MY2
Rated
voltage
Load type
Conditions
Operating frequency
Electrical life
100 V
AC
AC motor
50 W
, 100 V
AC single-phase with
2.8-A inrush current, 0.4-A carry
current
ON for 2 s, OFF for 30 s
100,000 operations
50 W
, 100 V
AC single-phase with
1.6-A inrush current, 1-A carry current
ON for 1 s, OFF for 30 s
300,000 operations
AC solenoid
24 W with 1-A carry current ON for 1.5 s, OFF for 1.5 s
4,000,000 operations
MY2E
Rated voltage
Load type
Conditions
Operating frequency
Electrical life
24 VDC
AC lamp
300 W with 50-A inrush current, 3-A
carry current ON for 5 s, OFF for 55 s
55,000 operations
MY4
Rated voltage
Load type
Conditions
Operating frequency
Electrical life
100 V
AC
AC solenoid
50 V
A with 2-A inrush current, 0.7A
carry current ON for 1 s, OFF for 3 s
25,000 operations
DC magnetic
switch
25 W with L/R = 40 ms , 0.2-A carry
current
AC magnetic
switch
35 V
A with 1.5-A inrush current,
0.35-A carry current
500,000 operations
24 VDC
DC solenoid 40 W with L/R = 10 ms, 1.6-A carry
current
ON for 0.5 s, OFF for 1.5 s
5,000,000 operations
30 W with L/R = 10 ms with 0.34-A
carry current
ON for 0.5 s, OFF for 1.5 s
6,000,000 operations
MY MY
6
Approved by Standards
Some MY Relays are available in models meeting various safety
standards.
When ordering, you must specify
the desired standards.
Refer
to
Ordering Information
for specific models. Note that the rat
-
ing recognized by the various standards sometimes vary from the
ratings
of the individual relays.
UL 508 Recognitions (File No. 41515)
No.
of poles
Coil ratings Contact ratings
2
6 to 240 V
AC
6 to 120 VDC
5 A, 120 V
AC resistive load
5 A, 28 VDC resistive load
5 A, 240 V
AC inductive load
3
5 A, 28 VDC resistive load
5 A, 240 V
AC inductive load
4
6 to 240 V
AC
6 to 120 VDC
3 A 28 VDC resistive load
3 A 120 V
AC inductive load
1.5 A, 240 V
AC inductive load
5 A, 240 V
AC inductive load
(between contacts of same
polarity)
5 A, 28 VDC resistive load
(between contacts of same
polarity)
0.2 A, 120 VDC
CSA 22.2 No. 0 and No.14 (File No. LR31928)
Model No.
of
poles Coil
ratings
Contact ratings
MYj
2, 3 6 to 240
VAC
6 to 120
VDC
5 A, 28 VDC resistive
load
5 A, 240 V
AC inductive
load
43 A, 28VDC resistive
load
3 A, 240 V
AC inductive
load
5 A, 240 V
AC inductive
load (between contacts
of same polarity)
5 A, 28 VDC resistive
load (between contacts
of same polarity)
0.2 A, 120 VDC
SEV
Model No. of
poles Coil
ratings
Contact ratings
MYj
2, 3 6 to 100
VDC
6 to 220
VAC
5 A, 200 V
AC
5 A, 24 VDC
LR (No. 563KOB-204524)
Model No.
of
poles Coil
ratings
Contact ratings
MYj-LR 2
6 to 240
VAC
6 to 120
VDC
2 A, 30 VDC inductive
load
2 A, 200 V
AC inductive
load
4
1.5 A, 30 VDC
inductive load
0.8 A, 200 V
AC
inductive load
1.5 A, 1
15 V
AC
inductive load
Engineering Data
Maximum Switching Capacity
MY1, MY2, MY3
Switching
voltage (V)
MY2-Y
Switching voltage (V)
Switching current (A)
Switching current (A)
AC resistive load
DC resistive
load
DC inductive
load (L/R = 7 ms)
AC inductive load
(cosf
= 0.4)
AC resistive load
DC resistive
load
DC inductive load
L/R = 7 ms
AC inductive load
(cosf
= 0.4)
MY MY
7
MY4, MY4Z
Switching
voltage (V)
Switching current (A)
AC resistive
load
DC resis-
tive load
DC resis-
tive load
L/R = 7 ms
AC inductive load
(cosf
= 0.4)
Life Expectancy
Switching current (A)
MY1,
MY2, MY3 (Inductive Loads)
Switching current (A)
MY1,
MY2, MY3 (Resistive
Loads)
110 VAC resistive load
220 VAC
resistive load
24 VDC resistive
load
24 VDC inductive load
(L/R = 7 ms)
110 VAC inductive
load (cosf
= 0.4)
220 VAC in-
ductive load
(cosf
= 0.4)
Life expectancy (x10 operations)
3
1,000
500
100
5,000
Life expectancy (x10 operations)
3
1,000
500
100
5,000
Switching current (A)
MY4 (Inductive Loads)
Switching current (A)
MY4 (Resistive Loads)
110 VAC resistive
load
30 VDC resistive
load
220 VAC resis-
tive load 110 VAC resistive
load
220 VAC resistive
load 30 VDC resistive
load
Life expectancy (x10 operations)
3
1,000
500
100
5,000
Life expectancy (x10 operations)
3
1,000
500
100
5,000
MY MY
8
Switching current (A)
MY4Z (Inductive Loads)
Switching current (A)
MY4Z (Resistive Loads)
220 VAC resis-
tive load
24 VDC resistive load
110 VAC (cosf
= 0.4)
24 VDC
L/R = 7 ms
220 VAC (cosf
= 0.4)
Life expectancy (x10 operations)
3
1,000
500
100
5,000
Life expectancy (x10 operations)
3
1,000
500
100
5,000
Switching current (A)
MY2-Y (Inductive Loads)
Switching current (A)
MY2-Y (Resistive Loads)
110 VAC resistive
load
220 VAC resistive load
24 VDC resistive
load
110 VAC (cosf
= 0.4)
24 VDC L/R = 7 ms
220 VAC (cosf
= 0.4)
Life expectancy (x10 operations)
3
1,000
500
100
5,000
Life expectancy (x10 operations)
3
1,000
500
100
5,000
MY MY
9
Dimensions
Note: All
units are in millimeters unless otherwise indicated.
Relays with Solder Terminals
2.6
Five, 1.2 dia. x 2.2 elliptic holes
0.5
35.5 max.
28 max.
6.3
MY1 Terminal arrangement/internal connections
(bottom view)
21.5
max.
6.4
MY1
2.6
MY2, MY2-TU, MY2N, MY2N-D2
Eight, 1.2 dia. x 2.2 ellipse holes
0.5
0.5 6.4 21.5
max.
6.3
28 max.
MY2N
Standard DC
type
AC type
Note: 1. AC type is equipped with a coil disconnection
self–diagnostic
function.
2.
Pay due attention as DC type has polarity
.
MY2N-D2
36
max.
MY MY
10
MY3, MY3-TU, MY3N, MY3N-D2, MYC3
2.6
Eleven, 1.2 dia. x 2.2
ellipse holes
0.5
36
max. 6.4
28 max.
6.3
21.5
max.
MY3N
Standard DC
type
AC type
Note: 1. AC
type is equipped with a coil disconnection self–
diagnostic
function.
2.
Do not reverse the polarity of DC relays.
MY4N-D2 MYC3
Coil connections
Input
Note: The MYC3 High–sensitivity Relay incorporates a
semi–conductor. A surge–absorb element should
be
attached to it
if the relay is used with a load that
can generate noise, or a surge current cannot be
avoided
in the circuit.
MY MY
11
MY4, MY4-TU
2.6
Fourteen, 1.2 dia. x 2.2
ellipse holes.
0.5
0.5
36
max. 6.4 21.5
max.
28 max.
6.3
Terminal arrangement/internal connections
(bottom view)
MY4N
Standard DC
type
AC type
Note: 1. AC
type is equipped with a coil disconnection self-
diagnostic function.
2.
Do not reverse the polarity of DC relays.
MY4N-D2
MYjI4
2.6
Fourteen, 1.2 dia. x 2.2
ellipse holes
3.3
20.3
36
max.
0.5
6.4 21.5 max..
6.3
28 max.
3 max.
Push button
Push button
2.6 2.6
Fourteen, 1.2 dia. x 2.2
ellipse holes
0.8
4 max. 0.5
36
max. 6.4 21.5 max.
28 max.
6.3
Mounting
holes
16.4
3.8
0.5
13.2
19.4
Two, 5 dia.
holes
3.4 dia.
hole
Note: 1. Mount
the relay with a socket.
2. The
above dimensions are for
-G type relays
(with
mounting studs).
3. T
est button
I4:
AC with red push button
DC with blue push button
MYjI
Note:
The terminal arrangement and internal connections of the above relays are as same as these of MY
j relays.
MY MY
12
MYj(N)-CR, MYj(Z)-CR, MY4N-D4
2.6
Fourteen, 1.2 dia. x 2.2 ellipse holes
0.5
0.5
53
max. 6.4
28 max.
6.3
21.5
max.
MYj(N)-C
R
CR
MYj(Z)-C
R
CR
MY4N-D4
Relays with PCB Terminals
MYj-02
MY4-02 (4PDT)
3.5
3.3
(2.6)
0.5
0.5
36
max. 4
28 max.
6.3
21.5
max.
Note: 1. The
figures in the parentheses are for MY4-02.
2. The above dimensions also apply to the SPDT,
DPDT,
and 3PDT relays.
4. The
internal connections of
the above relays are as
same
as these of MY
j relays.
PC board mounting holes
SPDT DPDT 3PDT 4PDT
13.2 13.2 13.2 13.2
4.3
6.3
44
4.1
12.65
6.35
3.75 Five,
1.3±0.1
holes
Eight,
1.3±0.1
holes
Eleven,
1.3±0.1
holes
Fourteen,
1.3±0.1
holes
Note:
The tolerance is
±0.1.
1
MY MY
13
Upper-mounting Relays
MYjFMY4F
2.6
Fourteen, 1.2 dia. x 2.2
ellipse holes
0.5
6.4
0.5
36
max
.
24.35
29 max. 38 44 max.
3.5
22.5 max.
Note: 1. The above dimensions also apply to the SPDT,
DPDT,
and 3PDT relays.
2. The
internal connections of
the above relays are as
same
as these of MY
j relays.
Mounting holes
Two 3.5 dia holes or M3 holes
38
Mounting Height with Socket
70
(87)
66 (83)
MY
MY
54 (71) 39 (56) MY
PYFjA(-E) PYF08M
PYj
DIN rail/surface–mounting socket Back-mounting socket
Note: 1. The
PTF-A can be rail–mounted or screw-mounted.
2. For
the MY
j
-CR (CR circuit built-in type) model, figure
in
the parentheses apply
.
3.
PYC-P hold down clip should be used with PYF08M.
Sockets
PYF08A-E PY14 PY14-Y1 PY14QN(2)
PY14QN(2)-Y1 PY14-02
PYF14A-NPYF08A-N
MY MY
14
Mounting Plates for Sockets
27.4
±0.15
21.6
72 wide ellipse
hole
27.4
±0.15
21.6
492
17 x 27.4 = 465.8 ±
0.6
72 wide el-
lipse hole
4.5
3.4
13.1
42±0.1 49
t = 1.6
492
17 x 27.4 = 465.8 ±
0.6
4.5
3.4 R1.7 13.1 21.4+0.2
0
39.7±0.2
39.7±0.2
21.6
13.1
17 x 27.4 = 465.8 ±
0.6
t = 1.6
86.4
Two, 3.4 dia. holes
42
±0.1 49
21.4+0.2
0
28
t = 1.6
PYP-1
Square
hole
PYP-18 PYP-36
Hold-down Clips
Hold-down
clips are used to hold relays to sockets and prevent them from coming loose due to vibration or shock.
Connection to socket
Connection to
mounting plate
For relays with test
buttons
For relays with CR circuits
PYC-A1
PYC-P
PYC-S
PYC–P2
Y92H-3
PYC-1
+0.3
–0
36
+0.3
–0
77.5 +0
–0.4
PY14-3 (for 4PDT)
with operation check terminal
Operation check terminal
81
56
28
38.5
29(7.7)
0.3 34.5+0.4
Operation checklamp can be built-in.
Three, 1.2 dia holes Two dia. holes Short-circuit lead wire
Mounting holes
78
Safety Standards for Sockets
Item Standards File No.
PYF08A (-E), PYF1
1A UL508 E87929
PYF14A (-E) CSA22.2 LR31928
MY MY
15
Precautions
Connections
Do not reverse polarity when connecting DC-operated relays with
built-in
diodes or indicators or high-sensitivity DC-operated relays.
Mounting
Whenever possible, mount relays so that it is not subject to
vibration or shock in the same direction as that of contact
movement.
The test button should be be pointed upwards when mounting
(refer
to the right figure).
T
est button
MY MY
16
OMRON Corporation
Relay Division
28th Fl., Crystal T
ower Bldg.
1-2-27, Shiromi, Chuo-ku,
Osaka 540 Japan
Phone: 06-949-6125 Fax: 06-949-6134
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To
convert millimeters into inches, multiply by 0.03937. T
o convert grams into ounces, multiply by 0.03527.
Cat. No. J01-E1-11 In the interest of product improvement, specifications are subject to change without notice.
Printed
in Japan
0794-2M