3www.conesys.com sales@aero-electric.com
MIL–DTL– 38999 S I
– –
MIL-DTL-38999
Performance Specifications
Series I
www.conesys.com sales@aero-electric.com
Performance Specifications
Operating Temperature Range
Finish B: -65°C to +175°C (-85°F to +347°F)
Finish F: -65°C to +200°C (-85°F to +392°F
Finish A: -65°C to +150°C (-85°F to +302°F)
Material and Plating Data (Finish)
B – aluminum shell, olive drab cadmium over nickel base
F – aluminum shell, electroless nickel finish
A– aluminum shell, silver to light iridescent yellow color
(bright) cadmium over electroless nickel
Corrosion Resistance
Finishes A and B withstand 500-hour salt spray.
Finish F withstands 48-hour salt spray.
Durability
Minimum of 500 mating cycles
Environmental Seal
Wired, mated connectors with specified accessories
attached, shall meet the altitude-immersion test specified in
MIL-DTL-38999.
Fluid Resistance
Connectors resist specified immersions in MIL-PRF-7808,
MIL-PRF-23699, MIL-PRF-5606, M2-V Chevron oil, Coolanol
25, MIL-DTL-83133 (JP-8), MIL-DTL-5624 (JP-4, JP-5),
SAE-AMS1424 Type I, and other solvents and cleaning agents.
Shell-to-Shell Conductivity
●Finish F = 1.0 millivolt maximum potential drop
●Finishes A and B = 2.5 millivolts maximum potential drop
Voltage Rating
Shielding Effectiveness
RFI and EMI attenuation at the specified frequencies meet
the requirements of MIL-DTL-38999.
●RFI shielding effectiveness of mated connectors with RFI
backshells is measured in a triaxial radio frequency leak-
age fixture.
●EMI shielding effectiveness is measured at the interface
of mated connectors and tested by the mode-stirred
technique specified in method 3008 of MIL-STD-1344.
Shock and Vibration Requirements
Wired, mated connectors shall not be damaged, nor shall
there be a current interruption longer than one microsecond
when subjected to the following:
Standard Shock
Mated connectors withstand a pulse of approximate half
sine wave of 300 G ± 15 percent magnitude with duration of
3 ± 1 milliseconds applied in three axes per MIL-STD-1344,
method 2004.
High Impact Shock
When mounted as specified in MIL-S-901, grade A, a drop
of a 400 lb. Hammer from 1 foot, 3 feet and 5 feet applied to
connector in three axes, totaling nine impacts.
Vibration
Mated connectors, with proper accessories, withstand the
following vibration levels:
●Sine Vibration per MIL-STD-202, method 204, test
condition G.
●Random Vibration per MIL-STD-1344, method 205, test
condition V and test condition VI, Letter “J” at ambient
temperature.
Service Rating
Suggested Operating Voltage Test Voltage Test Voltage Test Voltage Test Voltage
(Sea Level) Sea Level 50,000 Ft. 70,000 Ft. 100,000 Ft.
AC (RMS) DC V RMS V RMS V RMS V RMS
M 400 550 1300 550 350 200
N 300 450 1000 400 260 200
I 600 850 1800 600 400 200
II 900 1250 2300 800 500 200
Note: The establishment of electrical safety factors is left
entirely to the designer, as he is in the best position to know
exactly what peak voltages, switching currents, transients,
etc., can be expected in a particular circuit.