1
Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)
E2CY-SD
Digital Display
Fluororesin
Head
Digital Display
Fluororesin
Head
Non-ferrous
Metal Detection
Non-ferrous
Metal Detection
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Ordering Information
Sensors [Refer to Dimensions on page 7.]
Appearance Stable sensing distance Model
M5 E2CY-X1R5A 3M
5.4 dia. E2CY-C1R5A-1 3M
8 dia. E2CY-C2A 3M
Flat E2CY-V3A 3M
8 dia. E2CY-C2AF 3M
Shielded
1.5mm
2mm
3mm
2mm
Amplifier Units
Output configuration Model
DC 3-wire
NPN open collector E2CY-SD11 2M
Proximity Sensor with Separate
Amplifier Unit for Detection of
Non-ferrous Metals with Simple
Sensitivity Adjustment
Detects aluminum, copper, and other non-ferrous metals.
Product lineup includes compact, flat Sensor Head (E2CY-V3A) and
model with fluororesin (E2CY-C2AF) for resistance to chemicals.
Simple teaching function to easily adjust sensitivity.
Check detection status at a glance with numeric values on a digital
display.
Be sure to read Safety Precautions on
page 6.
2
E2CY-SD
Ratings and Specifications
Sensors
*1. The average value when using the DC-switching control output on the
Amplifier Unit.
Measurement conditions are as follows: standard sensing object, a distance
of twice the standard sensing object, and a set distance of half the stable
sensing distance.
*2. When the temperature around the Amplifier Unit is stable at 23°C.
*3. E2CY-C1R5A-1: ±15% max. of sensing distance at 23°C
*4. When extending the cable, use a 1.5D-2V (equivalent to JIS C 3501) cable
with characteristic impedance of 50 Ω.
Amplifier Units
*1. If the Sensor approaches iron or other ferrous metals, the digital display will
show negative values.
*2. When the temperature around the Sensor is stable at 23°C.
Note: You can mount the Amplifier Unit on a DIN Track without using the
Mounting Bracket.
Model
E2CY-X1R5A
E2CY-C1R5A-1
E2CY-C2A(F)
E2CY-V3A
Item
Stable sensing
distance 0 to 1.5 mm 0 to 2 mm 0 to 3 mm
Differential travel
10% max. of sensing distance with Amplifier
Unit in FINE mode
15% max. of sensing distance with Amplifier
Unit in NORM mode
Detectable object Non-ferrous metal
Standard sensing
object Aluminum: 8 × 8 × 1 mm Aluminum:
12 × 12 × 1 mm
Response
frequency *1
40 Hz min. with Amplifier Unit in FINE mode
100 Hz min. with Amplifier Unit in NORM mode
Ambient
temperature range
Operating: 10 to 55°C, Storage: 25 to
70°C (with no icing or condensation)
Ambient humidity
range
Operating and Storage: 35% to 95%
(with no condensation)
Temperature
influence *2
10 to 55
°
C
±15% max.
of sensing
distance at
23°C
±10% max.
of sensing
distance at
23°C
±15% max.
of sensing
distance at
23°C
0 to 40
°
C
±10% max.
of sensing
distance at
23°C *3
±10% max.
of sensing
distance at
23°C
Vibration resistance
Destruction: 10 to 500 Hz, 2-mm double am-
plitude or 150 m/s2 for 2 hours each in X, Y,
and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y,
and Z directions
Degree of
protection IEC 60529 IP67
Connection method Pre-wired Models (High-frequency coaxial
cable, Standard cable length: 3 m)
Cable length
compensation 0.5 to 5 m *4
Weight
(packed state) Approx. 35 g
Materials
Case Stainless steel Zinc die-cast
Sensing
surface
Heat-resistant ABS
(E2CY-C2AF: Fluororesin)
Cable Soft PVC (E2CY-C2AF: Fluororesin)
Clamping
nut
Nickel-plated brass (E2CY-X1R5A only)
Toothed
washer Zinc-plated iron (E2CY-X1R5A only)
Mounting
screws Zinc-plated iron (E2CY-V3A only)
Item Model E2CY-SD11
Power supply voltage
12 to 24 VDC ±10%, ripple: 10% max.
Power consumption 1,080 mW max. (45 mA max. at 24 VDC)
Sensing distance
adjustment range 10% min. of stable sensing distance
Sensitivity setting Teaching / manual adjustment
Control output
NPN open collector (26.4 VDC max.), load cur-
rent:100 mA max., residual voltage: 1 V max.
Functions
OFF-delay
timer
0 to 40 ms (1 to 20 ms: 1-ms increments, 20
to 40 ms: 5-ms increments)
Zero
reset Supported.
Intial
reset
Supported. (All settings are returned to their
default values.)
Hysteresis
setting
3 to variable
Self
diagnosis
Displays errors (sensor disconnection, sen-
sor short-circuit, or output short-circuit)
Operation mode Changed with NO/NC switch.
Protection circuits Power supply reverse polarity protection
and output short-circuit protection
Indicator Operation indicator (orange)
Digital display *1
Detection amount display (FINE: 4,000 max., NORM:
2,000 max.), bar display, function display (red)
Reverse display Supported.
Ambient temperature
range
Operating: 10 to 55°C, Storage: 25 to
70°C (with no icing or condensation)
Ambienthumidity
range
Operating and storage: 35% to 85% (with
no condensation)
Temperature influ-
ence *2
±10% max. of sensing distance at 23°C in
the temperature range of 10 to 55°C
Voltage influence ±1% max. of sensing distance in the rated
voltage range ±10%
Insulation resistance 20 MΩ min. (at 500 VDC) between current-
carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute. between
current-carrying parts and case
Vibration resistance
Destruction: 10 to 150 Hz, 1.5-mm double
amplitude or 100 m/s2 for 2 hours each in X,
Y, and Z directions
Shock resistance Destruction: 300 m/s2 3 times each in X, Y,
and Z directions
Degree of protection IEC 60529 IP50 (with Sensor cable con-
nected and protective cover attached)
Connection method
Pre-wired Model (Standard cable length: 2 m)
Weight (packed state)
Approx. 100 g
Materials
Case PBT
Cover Polycarbonate
Cable
connecting
screws
Zinc-plated iron
Accessories E39-L143 Mounting Bracket (SUS304
stainless steel), instruction manual
E2CY-SD
3
Engineering Data (Reference Value)
Sensing area
E2CY-X1R5A/E2CY-C1R5A-1 E2CY-C2A(F) E2CY-V3A
Influence of Sensing Object Size and Material
E2CY-X1R5A/E2CY-C1R5A-1 E2CY-C2A(F) E2CY-V3A
Temperature influence
E2CY-X1R5A/E2CY-C1R5A-1 E2CY-C2A(F) E2CY-V3A
*1. When the set distance is the maximum stable sensing distance multiplied by 1.2 and at an ambient temperature 23°C.
*2. When the set distance is the maximum stable sensing distance and at an ambient temperature 23°C.
3 2 1 0 1 2
2.0
1.5
1.0
0.5
0
X
Y
Sensing distance (variable):
0.15 to 1.5 mm
Distance X (mm)
Distance Y (mm)
Sensitivity
adjustment: 50%
Sensitivity
adjustment:
100%
Y
X
4 3 2 1 0 1 2 3
3.0
2.5
2.0
1.5
1.0
0.5
0
Distance X (mm)
Sensitivity
adjustment: 50%
Sensitivity
adjustment: 100%
Sensing distance (variable):
0.2 to 2 mm
Distance Y (mm)
X
Y
5 4 3 2 1 0 1 2 3 4
6
5
4
3
2
1
0
Distance X (mm)
Sensitivity
adjustment: 50%
Sensitivity
adjustment: 100%
Sensing distance
(variable): 0.3 to 3 mm
Distance Y (mm)
X
2.0
1.5
1.0
0.5
0 5 10 15 20 25 30
d ×
d t = 1 mm
Side length d of sensing object (mm)
Aluminum,
brass,
copper
Stainless
steel
(SUS304)
Distance X (mm)
X
3.0
2.5
2.0
1.5
1.0
0.5
0 5 10 15 20 25 30
d ×
d t = 1 mm
Side length d of sensing object (mm)
Aluminum,
brass,
copper
Stainless
steel
(SUS304)
Distance X (mm)
X
6
5
4
3
2
1
0 5 10 15 20 25 30
d
×
d t = 1 mm
Side length d of sensing object (mm)
Aluminum,
brass,
copper
Stainless steel
(SUS304)
Distance X (mm)
5
4
3
2
1
0
100 23405055
*1
*2
Ambient temperature (°C)
Sensitivity
adjustment: 120%
Sensitivity
adjustment: 100%
Distance (mm)
Measurement conditions: Sensor and Amplifier Unit
used as a set, Amplifier Unit set to NORM mode
5
4
3
2
1
0
10 0 23 40 50 55
Ambient temperature (°C)
Sensitivity
adjustment: 120%
Sensitivity
adjustment: 100%
Distance (mm)
Measurement conditions: Sensor and Amplifier Unit
used as a set, Amplifier Unit set to NORM mode
*1
*2
5
4
3
2
1
0
10 0 23405055
Ambient temperature (°C)
Sensitivity
adjustment: 120%
Sensitivity
adjustment: 100%
Distance (mm)
Measurement conditions: Sensor and Amplifier Unit
used as a set, Amplifier Unit set to NORM mode
*1
*2
E2CY-SD
4
I/O Circuit Diagrams
Connection
Sensing Distance Vs. Digital Display Value
E2CY-X1R5A/E2CY-C1R5A-1 E2CY-C2A(F) E2CY-V3A
Operation mode Timing Chart Output circuit
NO
NC
NORM
FINE
0
250
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
3250
3500
3750
4000
4250
Sensing Distance (mm)
0 0.3 0.6 0.9 1.2 1.5 1.8
Digital Display Value
0
250
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
3250
3500
3750
4000
4250
0 0.5 1 1.5 2 2.5 3
NORM
FINE
Sensing Distance (mm)
Digital Display Value
0
250
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
3250
3500
3750
4000
4250
0 0.6 1.2 1.82.4 33.6
NORM
FINE
Sensing Distance (mm)
Digital Display Value
Present
Not present
ON
OFF
ON
OFF
Sensing object
Amplifier Unit
Operation
indicator (orange)
Output
transistor 4.7 Ω
39 V
12 to 24 VDC
0 V
Load
Proximity
Sensor
main
circuit
100 mA
max.
Black
Control output
Blue
Brown
Present
Not present
ON
OFF
ON
OFF
Sensing object
Amplifier Unit
Operation
indicator (orange)
Output
transistor
0 V
12 to 24 VDC
Brown
Black
Blue
Control output
Sensors
Shield Amplifier Units
Line Sensor cable connecting screws
Sensor cable
Sensor Cable Connection Diagram (Enlarged)
Side View
E2CY-SD
5
Nomenclature
Amplifier Units
(3) Operation Buttons
Use these buttons to change the display or to change the function settings. Button functions depend on the current mode.
The following table lists the available functions.
* FINE Mode enables you to perform measurements at twice the step of NORM Mode. However, this results in a slower response.
UP
SET RUNE2CY-SD11
DOWN
MODE
(Sensor Head mounting end)
(Pre-wired cable end)
Operation indicator (orange)
(2) Mode selector
Sensor cable connecting
screws (M2.6)
(1) Digital display (red)
(3) Operation buttons
(1) Digital Display
The digital display shows information such as the detection amount or the current
function name.
(2) Mode Selector
The mode selector is used to switch between modes.
Mode Description
SET Select this mode to set detection conditions, perform teaching,
or to initialize settings to their default values.
RUN
Select this mode to perform actual sensing operation or to
perform the following functions.
Manually adjusting the threshold
Checking the current threshold value
Zero reset
Locking button operation
Button SET Mode RUN Mode
UP Button Changes the function in the forward direction. Changes
the set value in the forward direction. Performs posi-
tioning teaching.
Increases the threshold value.
DOWN Button Changes the function in the reverse direction. Changes
the set value in the reverse direction. Performs teach-
ing without a workpiece.
Decreases the threshold value.
MODE Button Selects the function. Selects the set value. Checks the current threshold value. Performs a zero
reset.
Function Set value
Description
Change function: UP/DOWN Buttons
Change set value: UP/DOWN Buttons
Select function: MODE Button
Select set value: MODE Button
Sensing threshold value
Performs the following types of teaching:
Teaching without a workpiece
Positioning teaching
Teaching with/without a workpiece
1- p NO/NC
Changes the operation mode.
NO (normally open): Turn output ON when an object is detected.
NC (normally close): Turn output ON when no object is detected.
2-fn NORM/FINE
Changes sensor precision.
NORM: Standard *
FINE: High precision
3-tf 0 to 40ms
Changes the OFF-delay time.
Sets a delay between 0 to 20 ms in increments of 1 ms. Sets a delay between 20 to 40 ms in
increments of 5 ms.
4-dp Value/segment bar Changes the detection amount display.
5-r Normal or reverse
Changes the display direction.
Normal: The Sensor is connected to the left end.
Reverse: The Sensor is connected to the right end.
6-hy 3 to variable Changes the hysteresis width.
o
u
E2CY-SD
6
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the product under ambient conditions that exceed the
ratings.
Design
Influence of Surrounding Metal
When mounting the Sensor within a
metal panel, ensure that the
clearances given in the following
table are maintained. Failure to
maintain these distances may cause
deterioration in the performance of
the Sensor.
Influence of Surrounding Metal (Unit: mm)
The E2CY-V3A can be embedded in metal with the sensing surface
at the same level as the metal surface.
Mutual Interference
When installing Sensors face-to-face or side-by-side, ensure that the
minimum distances given in the following table are maintained.
Effects of a High-frequency Electromagnetic Field
If the Sensor is located near a device that generates high frequencies
or a transceiver, it may be affected by such a device and malfunctions
may occur.
Mounting
Do not use excessive force when tightening the nuts on the E2CY-
X1R5A. A toothed washer must be used with the nut.
Mounting Unthreaded Cylindrical Models
When using a set screw, tighten it to a torque of 0.2 N·m max.
Do not tighten the mounting screw for the E2CY-V3A with
excessive force. Always use a washer when tightening the
mounting screw.
Adjustment
Power ON
The E2CY requires a minimum of 200 ms from the time the power
supply is turned ON before it can begin detection. Do not remove the
Sensor Head while the power supply is turned ON. If the E2CY-SD11
and load are connected to separate power supplies, always turn ON
the power supply to the E2CY-SD11 first.
Power OFF
Output pulses may occur when the power supply is turned OFF. Turn
OFF the power supply to the load or load line first.
Teaching
Make sure that the Sensor is in operating condition before making
sensitivity adjustments.
Processing the Sensor Cable Ends
When cutting or extending the cable, the end of the Sensor cable
connected to the E2CY-@ must be processed as shown in the
following illustration.
The length compensation range for cutting or extending the cable is
0.5 to 5 m. When extending the cable, use a 1.5D-2V (equivalent to
JIS C 3501) cable with characteristic impedance of 50 Ω.
Amplifier Unit Cable Extension
Do not extend the cable to more than 30 m. Use a cable of 0.3 mm2
or greater for extensions.
WARNING
Precautions for Correct Use
Model Item l d D m
E2CY-X1R5A
0
5
0
9
E2CY-C1R5A-1 5.4
E2CY-C2A(F) 815
E2CY-V3A 12 18
l
mD
d dia.
Sensing surface of E2CY-V3A
B
A
Mutual Inter
f
erence (Unit: mm)
Model Item A B
E2CY-X1R5A
20 15
E2CY-C1R5A-1
E2CY-C2A(F)
E2CY-V3A 30 12
Model Torque
E2CY-V3A 0.15 N·m
Model Torque
E2CY-X1R5A 0.98 N·m
Note: The above leeways in tighten torque
assume that a toothed washer is being
used.
7 to 11.5 mm
Dimpled end of
set screw (M3)
(Unit: mm)
*2
*1
5
7 to 8
4 to 52.5
14 max.
Sensor cable
*1. Be sure to turn over the braided shield so that
none of its thin wires are left.
*2. Make sure that an insulation distance of at least
2.5 mm is maintained.
E2CY-SD
7
Dimensions
Sensors
Amplifier Units
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
M5 × 0.5 4
9.7 dia.
815
18
Two clamping nuts
Two toothed washers
2.5-dia. coaxial cable (50 Ω) with
1 conductor (Conductor cross
section: 0.14 mm2),
Standard length: 3 m
E2CY-X1R5A
5.4 dia. 18
2.5-dia. coaxial cable (50 Ω) with
1 conductor (Conductor cross
section: 0.14 mm2),
Standard length: 3 m
E2CY-C1R5A-1
E2CY-V3A
2.4
4.9
12
5.2 4.8
10.7
23
25
4.5
Two, M2
4.8
3.7
244.6
Sensing
surface Two mounting
holes
Mounting Hole
Dimensions
8 dia. 18
* E2CY-C2AF: 2.5-dia. coaxial cable (Fluororesin)
with 1 conductor (Conductor cross section:
0.17 mm2),
Standard length: 3 m
2.5-dia. coaxial cable (50 Ω) with
1 conductor (Conductor cross
section: 0.14 mm2),
Standard length: 3 m *
E2CY-C2A(F)
2
4
3.9
10.3
0.2
4
1.85
3.4
4.4
4.4
3.4
R2
4.9×3=14.7
(21.9)
(3.8)
(25.9)
70 6
7
21.6
32.5
16
10.6
33.4 16
24 34.8
1633.4
10
27.5 *
(7.7) (7.2)
With Mounting
Bracket Attached
Sensor cable outlet
Sensor cable
Sensor cable connecting screws (M2.6)
Operation indicator (orange)
Digital display (red)
Two, M3
Mounting Hole Dimensions
Cover
Cover opening
direction
Two mounting holes
Two, 3.2-dia. mounting holes
E39-L143 Mounting Bracket (removable),
Stainless steel (SUS304)
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm),
Standard length: 2 m
* The dimension to the digital display surface is 29.3
mm, and the dimension to the operation button
surface is 29.8 mm.
Note: You can mount the Amplifier Unit on a DIN
Track without using the Mounting Bracket.
E2CY-SD11
Bending start position A
Sensor Head
Minimum bending radius B
Bending start
position C
Amplifier Unit
Minimum bending radius: 12 mm
Bending start position: 10 mm
Cable Bending Start Position and Minimum Bending Radius
Sensors Amplifier Units
(Unit: mm)
Model Item A B C
E2CY-X1R5A
15 25
35
E2CY-C1R5A-1
E2CY-C2A
E2CY-C2AF 30 35
E2CY-V3A 15 25
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or
comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING
SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH
PURPOSES. Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.
Authorized Distributor:
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. D112-E1-01
Printed in Japan
0811 (0811) (W)
© OMRON Corporation 2011 All Rights Reserved.
OMRON Corporation Industrial Automation Company
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON SCIENTIFIC TECHNOLOGIES INC.
6550 Dumbarton Circle,
Fremont, CA 94555-3605 U.S.A.
Tel: (1) 510-608-3400/Fax: (1) 510-744-1442
CSM_2_2_0812
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
E2CY-C1R5A-1 3M E2CY-SD11 2M