74 General-purpose Limit Switch D4A-@N
General-pu rp ose Limi t Switch
D4A-@N
The Limit Switch with Better Seal, Shock
Resistance, and Strength
A double se al on the h ead , a co mp lete gas ket cov er, and ot her
fea tures ens ure a bett er seal (mee ts UL NEM A 3, 4, 4 X, 6P, 12,
13).
Block mounting method to reduce weight to 290 g.
Block mounting method also reduces downtime for mainte-
nance.
Wide standard operating temperature range:
–40°C to 100°C (standard type).
Models with fluoro-rubber available for greater resistance to
chemicals.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
Model Number Structure
Model Number Legend
1. Receptacle Box
1: 1/2-14 NPT conduit (SPDT, double-break)
2: 1/2-14 NPT conduit (DPDT, double-break)
3: G 1/2 conduit (SPDT, double-break)
4: G 1/2 conduit (DPDT, double-break)
2. Switch Box
1: SPDT, double-break, without indicator
3: SPDT, double-break, neon lamp
E: SPDT, double-break, LED
(24 VDC, leakage current: 1.3 mA)
5: DPDT, double-break, simultaneous operation, without indi-
cator
7: DPDT, double-break, sequential operation, without indicator
(See note 1.)
9: DPDT, double-break, center neutral operation, without indi-
cator (See note 2.)
L: DPDT, double-break, simultaneous operation, neon lamp
P: DPDT, double-break, simultaneous operation, LED
3. Head
01: Roller lever, standard
02: Roller lever, high-sensitivity
03: Roller lever, low torque
04: Roller lever, high-sensitivity, low torque
05: Roller lever, maintained
17: Roller lever, sequential operation
18: Roller lever, center neutral operation
06: Side plunger, standard
07-V: Side plunger, ver tical roller
07-H: Side plunger, hor izontal roller
08: Side plunger, adjustable
09: Top plunger, standard
10: Top plunger, roller
11: Top plunger, adjustable
12: Fle x ible rod, spring wire
14: Flexible rod, plastic rod
15: Flexible rod, cat whisker
16: Flexible rod, coil spring
Note: 1. Use the D4A-0017N Special Head.
2. Use the D4A-0018N Special Head.
3. Fluoro-rubber sealed type is also available.
1 2 3
D4A-@@@@N
General-pu rpose Limit Switc h D4A-@N 75
Ordering Information
List of Models
SPDT, Double-break Switches
Note: 1. The lever is not included with the Roller Level Models. Select the lever from those listed in this data sheet and order it separately (refer
to Levers on pages 92 and 93).
2. The Maintained Switches have a loc k mechanism for the s witch operation and thus use a Fork Le ver Lock.
3. Switches are also available with @1/2-14 NPT conduits. The model numbers correspond as fol lows:
G 1/2 Conduits 1/2-14 NPT Conduits
D4A-3@@@N D4A-1@@@N
D4A-4@@@N D4A-2@@@N
4. Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these
Switches, however, is 10 to 120°C.) Add “-F” to the model number. (Exam ple: D4A-3101N becomes D4A-3101N-F.) Ask your nearest
OMRON representative for details .
Receptacle box G 1/2 Conduit
Indicator Without indicator With neon lamp indicator
(AC) With LED indicator (DC)
Actuator Model Approved
standards Model Approved
standards Model
Roller le ver
(See note 1.) Standard D4A-3101N UL, CSA D4A-3301N UL, CSA D4A-3E01N
High-sensitivity D4A-3102N UL, CSA D4A-3302N UL, CSA D4A-3E02N
Low-torque D4A-3103N UL, CSA --- UL, CSA ---
High-sensitivity, Low-
torque D4A-3104N UL, CSA D4A-3304N UL, CSA ---
Maintained
(See note 2.) D4A-3105N UL, CSA D4A-3305N UL, CSA D4A-3E05N
Side plunger Standard D4A-3106N UL, CSA --- UL, CSA ---
Vertical roller D4A-3107-VN UL, CSA D4A-3307-VN UL, CSA D4A-3E07-VN
Horizontal roller D4A-3107-HN UL, CSA D4A-3307-HN UL, CSA ---
Adjustable D4A-3108N UL, CSA D4A-3308N UL, CSA D4A-3E08N
Top plunger Standard D4A-3109N UL, CSA D4A-3309N UL, CSA ---
Roller D4A-3110N UL, CSA D4A-3310N UL, CSA ---
Adjustable D4A-3111N UL, CSA D4A-3311N UL, CSA ---
Flexible rod Spring wire D4A-3112N UL, CSA D4A-3312N UL, CSA D4A-3E12N
Plastic rod D4A-3114N UL, CSA D4A-3314N UL, CSA D4A-3E14N
Cat whisker D4A-3115N UL, CSA D4A-3315N UL, CSA D4A-3E15N
Coil spring D4A-3116N UL, CSA D4A-3316N UL, CSA D4A-3E16N
76 General-purpose Limit Switch D4A-@N
DPDT, Double-break Switches
Note: 1. The lever is not included with the Roller Level Models. Select the lever from those listed in this data sheet and order it separately (refer
to Levers on pages 92 and 93).
2. The Maintained Switches have a lock mechanism for the switch operation and thus use a Fork Lever Lock.
3. Switches are also available with @1/2-14 NPT conduits . The model numbers correspond as follows:
G 1/2 Conduits 1/2-14 NPT Conduits
D4A-3@@@N D4A-1@@@N
D4A-4@@@N D4A-2@@@N
4. Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these
Switches, however, is 10 to 120°C.) Add “-F” to the model number. (Example: D4A-4501N becomes D4A-4501N-F.) Ask your nearest
OMRON representative about delivery times and prices.
Receptacle box G 1/2 Conduit
Indicator Without indicator With neon lamp indicator
(AC) With LED indicator (DC)
Actuator Model Approved
standards Model Approved
standards Model
Roller lever
(See note 1.) Sta ndard D4A- 4501N UL, CSA D4A-4L01N UL, CSA D4A-4P01N
High-sensitivity D4A- 4502N UL, CSA --- --- ---
Low-torque D4A- 4503N UL, CSA --- --- ---
High-sensitivity, Low-
torque D4A-4504N UL, CSA --- --- ---
Maintained
(See note 2.) D4A-4505N UL, CSA --- --- ---
Sequential operation D4A-4717N UL, CSA --- --- ---
Center neutral opera-
tion D4A-4918N UL, CSA --- --- ---
Side plunger Standard D4A- 4506N UL, CSA --- --- ---
Vertical roller D4A-4507-VN UL, CSA --- --- ---
Hori zontal roller D4A-4507-HN UL, CSA --- --- ---
Adjustable D4A- 4508N UL, CSA --- --- ---
Top plunger Standard D4A-4509N UL, CSA --- --- ---
Roller D4A- 4510N UL, CSA D4A-4L10N UL, CSA D4A-4P10N
Adjustable D4A- 4511N UL, CSA --- --- ---
Flexible rod S pr ing wire D4A-4512N UL, CSA --- --- ---
Plastic rod D4A-4514N UL, CSA --- --- ---
Cat whisker D4A-4515N UL, CSA --- --- ---
Coil spring D4A-4516N UL, CSA --- --- ---
General-pu rpose Limit Switc h D4A-@N 77
Individual Parts
Replacement of Parts
Because the D4A-@N employs block mounting construction, the
switch box, receptacle, and operating head may be ordered as a
complete assembly or individually as replacement parts.
Receptacle Bo x
Note: 1. M6-screw mounting (standard mounting)
2. 10-32UNF-sc rew mounting (standard mounting)
Switch Box
Receptacle Switch box Head Lever
D4A-1101N D4A-1000N D4A-0100N D4A-0001N
Levers for Roller Lever Switches are
optionally available. Select the lever from
those listed in this datasheet and order
(refer to Levers on pages 92 and 93).
Ty pe Appearance 1/2-14NPT conduit (See note 2.) G1/2 conduit (See note 1.)
Model Approved
standards Model Approved
standards
SPDT
double-
break
D4A-1000N UL , CSA D4A-3000N UL, CSA
DPDT
double-
break
D4A-2000N UL , CSA D4A-4000N UL, CSA
Type Appearance Without indicator With neon lamp indicator
(AC) With LED
indicator (DC)
Model Approved
standards Model Approved
standards Model
SPDT
double-break D4A-0100N UL, CSA D4A-0300N UL, CSA D4A-0E00N
DPDT
double-break Simultaneous
operation D4A-0500N UL, CSA D4A-0L00N --- D4A-0P00N
Sequential oper-
ation D4A-0700N UL, CSA --- --- ---
Center neutral
operation D4A-0900N UL, CSA --- --- ---
(Without indicator lamp)
(Without indicator lamp)
78 General-purpose Limit Switch D4A-@N
Heads
Note: 1. Lever s for Roller Lever Switches are opt ionally available. Selec t the lever from those listed in this data sheet and order (refer to Levers
on pages 92 and 93).
2. The D4A-C00 adjustable roller lev er is too heavy and long f or these heads and it should not be used or mechanical malfunction will result.
3. These heads cannot be used for double break operations.
Levers
Note: Refer to page 92 for Lever shapes and applicable models.
Type Appearance Approved standard s
Roller lever
(See note 1.) UL, CSA
UL, CSA
Side pl unge r UL, CSA
Top plunger UL, CSA
Flexible rod UL, CSA
Standard: D4A-0001N
High-sensitivity: D4A-0002N
Low torque: D4A-0003N (see note 2)
Sequential operation: D4A-0017N (see note 3)
Center neutral operation: D4A-0018N (see note 3)
Maintained: D4A-0005N
Standard:
D4A-0006N Horizontal roller:
D4A-0007-HN Vertical roller:
D4A-0007-VN Side adjustable:
D4A-0008N
Standard:
D4A-0009N Roller plunger:
D4A-0010N Plunger adjustable:
D4A-0011N
Spring wire
D4A-0012N Plastic rod
D4A-0014N Cat whisker
D4A-0015N Coil spring
D4A-0016N
Actuator type Model
Roller Lever D4A-A00
D4A-A10
D4A-A20
D4A-A30
D4A-B06
Adjustable Roller Le ver D4A-C00
D4A-D00
Resin Loop Lever D4A-F00
Fork Lever Lock D4A-E30
D4A-E20
D4A-E10
D4A-E00
General-pu rpose Limit Switc h D4A-@N 79
Specifications
Approv ed Standards
Note: Ask your OMRON representative for information on approved models.
Approv ed Standard Ratings
UL/CSA
A600
D4A-@1@@N (SPDT, Double-break, Without Indicator)
A300
D4A-@3@@N (SPDT, Double-break, With Neon Lamp)
B600
D4A-@5@@N (DPDT, Double-break, Simultaneous Operation)
D4A-@7@@N (DPDT, Double-break, Sequential Operation)
D4A-@9@@N (DPDT, Double-break, Center Neutral Operation)
CCC (GB14048.5)
Agency Standard File No.
UL UL508 E76675
CSA CSA C22.2 No. 14 LR45746
CCC (CQC) GB14048.5 2003010305077615
Rated volta ge Carry current Current Volt-amperes
Make Break Make Break
120 VAC
240 VAC
480 VAC
600 VAC
10 A 60 A
30 A
15 A
12 A
6 A
3 A
1.5 A
1.2 A
7,200 VA 720 VA
Rated volta ge Carry current Current Volt-amperes
Make Break Make Break
120 VAC
240 VAC 10 A 60 A
30 A 6 A
3 A 7,200 VA 720 VA
Rated volta ge Carry current Current Volt-amperes
Make Break Make Break
120 VAC
240 VAC
480 VAC
600 VAC
5 A 30 A
15 A
7.5 A
6.0 A
3 A
1.5 A
0.75 A
0.6 A
3,600 VA 360 VA
Applicable category and ratings
AC-15 2 A/125 VAC
80 General-purpose Limit Switch D4A-@N
Gener al Rat ings
Note: 1. The above current ratings are for steady-state current.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp loads have an inrush current of 10 times the steady-state current.
4. Motor loads have an inrush current of 6 times the steady-state current.
5. For those with indicators, refer to the following rated voltages.
Ratings for Indicators
Type Rated voltage Non-inductive load Inductive load
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
SPDT double-break
(with/without
indicator)
125 VAC (See note 5.) 10 A 10 A 3 A 1.5 A 10 A 5 A 2.5 A
250 VAC (See note 5.) 10 A 10 A 2 A 1 A 10 A 3 A 1.5 A
480 VAC 10 A 10 A 1.5 A 0.8 A 3 A 1.5 A 0.8 A
600 VAC 3 A 1 A 1 A 0.5 A 1.5 A 1 A 0.5 A
8 VDC 10 A 6 A 3 A 10 A 6 A
14 VDC 10 A 6 A 3 A 10 A 6 A
30 VDC6 A4 A3 A6 A4 A
125 VDC (See note 5.) 0.8 A 0.2 A 0.2 A 0 .8 A 0.2 A
250 VDC (See note 5.) 0.4 A 0.1 A 0.1 A 0 .4 A 0.1 A
DPDT double-break
(without indicator) 125 VAC 5 A 2 A 4 A 3 A
250 VAC 3 A 1 A 2 A 1.5 A
480 VAC 1.5 A 0.5 A 1 A 0.8 A
600 VAC 1 A 0.4 A 0.7 A 0.5 A
14 VDC5 A2 A4 A3 A
30 VDC3 A1 A2 A1.5 A
125 VDC 0.4 A 0.1 A 0.4 A 0. 1 A
250 VDC 0.2 A 0.05 A 0.2 A 0.05 A
DPDT double-break
(wit h indic a tor) 125 VAC 5 A 2 A 4 A 3 A
250 VAC 3 A 1 A 2 A 1.5 A
12 VDC 5 A --- --- --- ---
24 VDC 3 A
48 VDC 1 A
Type SPDT, double-brea k DPDT, double-break
Without ind icator With indicator Without indicator With indicator
Inrush
current Normally cl osed 30 A max.
Normally open 20 A max.
Classification Indicator Model Rated voltage Carry current Internal resistance
SPDT
double-break Neon lamp D4A-0300N 125 VAC, 250 VAC Approx. 0.47 mA 150 k
LED D4A-0E00N 12 VDC Approx. 3.2 mA 2.2 k
24 VDC Approx. 4 mA 4.7 k
24 VDC Approx. 1.3 mA 15 k
48 VDC Approx. 2 mA 22 k
DPDT
double-break Neon lamp D4A-0L00N 125 VAC, 250 VAC Approx. 0.28 mA 240 k
LED D4A-0P00N 48 VDC Approx. 1.4 mA ---
General-pu rpose Limit Switc h D4A-@N 81
Characteristics
Note: 1. The above figures are initial values.
2. Excluding maintained models.
3. The values are calculated at an operating t emperature of 5°C to 35°C, and an operating humidity of 40% to 70%. Contact your OMRON
sales representative for more detailed information on other operating environments.
4. 1,500 VAC is applied to the indicator lamp type.
5. Not including wobble levers (cat whisker, plastic rod, coil spring, and spring wire types).
5-1. Excluding low-torque and high-sensitivity models.
5-2. Including roller lever low-torque and high-sensitivity operating models.
Degree of protection IP67
Durability (See note 3.) Mechanical: SPDT, double-break, roller lev er: 50,000,000 operations min. (See note 2.)
DPDT, double-break, roller lever : 30,000,000 operations min. (See note 2.)
Electrical: SPDT, double-break: for 125 VAC, 10 A resistive load: 1,000,000 operations min.
DPDT, double-break: fo r 125 VAC, 5 A resistive load: 750,000 operations min.
Operating speed 1 mm to 2 m/s (for D4A-3101N roller le ver model)
Operating frequency Mechanical: 300 operations/minute
Electrical: 30 operations/minute
Rated frequency 50/60 Hz
Insulation resistance 100 M min. (at 500 VDC) between terminals of the same polarity, between current-carrying metal parts and
ground, and between each term in al and non-current-carrying metal par t
Contact resistance 25 m max. (initial v alue)
Temperature rise 50°C max.
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min. between terminals of same polarity
2,200 VAC, 50/60 Hz for 1 min. between current-carrying metal parts and ground, and between each terminal
and non-current-carrying metal par t (See note 4.)
Pollution degree
(operating environment) 3
Protection against electric
shock Class I (with grounding terminal)
Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (See note 5.)
Shock resistance Destruction : 1,000 m/s2 min.
Malfunction: SPDT, double-break, roller le ver: 600 m/s2 min. (See note 5.)
DPDT, double-break, roller lever : 300 m/s2 min. (See note 5.)
Ambient operating humidity 35% to 95% (with no icing)
Weight Approx. 290 g (for D4A-3101N roller lever model)
Type Roller lever
(See note 5-1.) Plunger, flexible rod
(See note 5-2.) With indicator Fluoro-rubber seal
Ambient temperature –40°C to 100°C –20°C to 100°C –10°C to 80°C–10°C to 120°C
82 General-purpose Limit Switch D4A-@N
Connections
Conta ct Fo rms (Switc h Bo x es )
STDP Double-break Switches
Note: Switches with indicators are factory-set to light when the switch is not operated.
DTDP Double-break Switches
Each of these Switches can be used to replace two limit swit ches in applications, such as high-speed control in machine tools and s witching motors
between forward and revers e, that previously required 2 limit switches. This simplifies wiring, saves space, and reduces costs.
Type Contact model Operating pattern
Without indicat or With neon l a mp ind icat or
(See note.) With LED indicator
(See note.)
1NC/1NO snap-action D4A-0100N D4A-0300N
Lamp Unit Internal Circuits
D4A-0E00N
Lamp Unit Internal Circuits
3
4
1
2
Za
4
12
3
Lamp
unit
Lamp
unit
Za
Neon lamp
Resistor
4
12
3
Lamp
unit
Lamp
unit
Za
Bridge rectifier LEDs
Resistor
1-2
3-4
Energized
Stroke
Type Contact model Operating pattern Remarks
Without indicator With neon lamp
indicator
(See note.)
With LE D indicator
(See note.)
2NC/2NO snap-action,
simultaneous opera-
tion
D4A-0500N D4A-0L00N D4A-0P00N Head is compatible
with double-break
head. Can be switched
for operation on both
sides of actuator.
2NC/2NO snap-action,
sequential operation
(2-step operation)
D4A-0700N --- --- Use the D4A-0017N
Special Head.
2NC/2NO snap-action,
central neutral opera-
tion
D4A-0900N --- --- Use the D4A-0018N
Special Head.
5-6
7-8
1-2
3-4
Energized
Stroke
5-6
7-8
1-2
3-4
Energized
Stroke
5-6
7-8
1-2
3-4
Right
operation
Left
operation Free
position
Energized
General-pu rpose Limit Switc h D4A-@N 83
Note: Switches with indicators are factory-set to light when the switch is not operated, but the setting can be changed to light for operation (dotted
lines).
Nomenclature
DPDT Double-break
Note: 1. NBR is used in rubber components.
2. Fluoro-r ubber sealed types use fluoro-rubber.
3. For Roller Levers, there is some lever play in the free position (about 2 mm), but this is due to the structure of the head and does not
interfere with performance.
Item Without indicat or With neon la m p indicator ( See note.) With LED indicator (See note.)
Contact
form D4A-0500N
D4A-0700N
D4A-0900N
D4A-0L00N D4A-0P00N
Lamp unit
internal cir-
cuit
---
4
1
8
5
3
2
7
6
Za
34
12
78
56
Lamp
unit
Lamp
unit
Lamp
unit
Lamp
unit
Za Za
34
12
78
56
Lamp
unit Lamp
unit
Lamp
unit Lamp
unit
Za Za
Neon lamp
Resistor
Bridge rectifier
Constant
current
diode
LED
Head
Operating Position Mark
(arrow)
Bearings
Receptacle
Conduit Opening
Roller
The roller actuator is made of hardened
stainless steel and excels in resistance to
wear.
Lever
With the Roller Lever Switch, the lever can be
installed anywhere in a 360° range (180° if the
lever is reversed and attached to the shaft).
Oil Seal
Improved sealing property is ensured with a
double-seal construction (a oil seal plus an
X-ring seal).
Switch Box
Boasts long life expectancy (50 million mechanical
operations or more with the 2-pole Double-break
Switches and 30 million mechanical operations or
more with the DPDT Double-break Switches).
Ground T erminal Screw
A ground terminal is provided to enhance safety.
Switch Box Screw
Sealed Gasket
With the Roller Lever and Side Plunger Switches, the
direction of the switch head can be varied to any of the four
directions by loosing the roller lever switch screws at the
four corners of the head.
The Roller Lever Switch
employs a system which
allows selection of the
operation of only one side
(left or right) or both sides
without use of any tools.
The copper-alloy bearings ensure long life ex-
pectancy.
The plug-in type receptacle provides adequate
space for wiring.
G 1/2 conduit threads featuring high sealing
property are used. (Consult your OMRON
representative for details on SC connectors).
A terminal box with 1/2-14NPT conduit threads
is also available on request. The employed full-cover method
prevents the gasket from direct
exposure to oil or water spray.
A Phillips screw is used to secure the switch
housing for ease of use, and features a meas-
ure to prevent the screw from coming off.
84 General-purpose Limit Switch D4A-@N
Easy-maintenan ce Block Mounting
Block mounting makes it possible to easily assemble or disassemble
the head, s witch body, and receptacle of the D4A-@N by ti ghtening or
loosening the attached screws .
Engineering Data
Electrical Durability (SPDT Double-break)
Electrical Durability (DPDT Double-break)
Actuator
Head
Receptacle
Switch box
125 V A C
250 V A C
480 V A C
125 V A C
250 V A C
480 V A C
(Ambient temperature: 5°C to 35°C; ambient humidity: 40% to 70%)
Switching current (A)
Durability (x 104 operations)
Durability (x 104 operations)
Switching current (A)
Operating frequencies:
30 operations/min,
cosφ = 1 Operating frequencies:
30 operations/min,
cosφ = 0.4
125 V A C
250 V A C
480 V A C
125 V A C
250 V A C
480 V A C
Durability (x 104 operations)
Durability (x 104 operations)
Switching current (A) Switching current (A)
Operating frequencies:
30 operations/min,
cosφ = 1
Operating frequencies:
30 operations/min,
cosφ = 0.4
General-pu rpose Limit Switc h D4A-@N 85
Installation
Operation
Changing the Operating Direction
The head of the side rotary type can be converted in seconds to CW,
CCW, or both-way operation. Follow the procedures on the right
hand side for conversion (not applicable to the Maintained, Sequen-
tial Operating, Center Neutral Operating Switches).
Operating Part (Rear of Head)
Procedures
1. Dismount the head by loosening the four screws that secure it.
2. Turn over the head to set the desired operation (CW, CCW, or
both). The desired side can be selected by setting the mode
selector knob shown in the figure. This knob is factory set to the
“CW+CCW” (both-wa y oper ati on) position.
3. When set to the CW position, the head rotates in clockwise direc-
tion.
When set to the CCW position, the head rotate s in counterclock-
wise direction.
In either case, be sure to accurately align the arrow mark to the
setting position.
Operating position
arrow marks
86 General-purpose Limit Switch D4A-@N
Head and Lever Positions
The operating head can be positioned and lock ed in any of four 90° positions and a lev er can lock in any position through 360° around the shaft of
the Limit Switch. Furthermore, the lever can be reversed and attached to the shaft (ref er to the figures below on the right hand side). Therefore t he
roller is compatible with a wide movement range of a dog. A Fork Lever Lock can be used with maintained models (D4A-0005N ) only.
Lighting Mode Selection of Indicators
The lighting mode of the operation indicator can be changed easily between two modes: lighting when the Switch is operating and lighting when
the Switch is not operating.
Loosen the screw
to adjust the
length of the rod.
Loosen the bolt to
adjust the length
of the lever. Adjustable
between 33
and 91 mm
D4A-E00 D4A-E10
D4A-E20 D4A-E30
Four, M4 x 12
Remove the head from the Switch by
loosening the screws (the screws can be
loosened but not removed from the
head).
The operating head can be
positioned and locked in
any of four 90° positions.
The lever can lock in any position through 360° around
the shaft. The lever can be reversed and attached to the
shaft, in which case the switching operation should com-
plete in a range of 0° to 180°.
By loosening the Allen-head bolt on an adjustable roller lever
or rod lever, the length of the lever can be adjusted.
D4A-C00 D4A-D00
180° operating
position
360°
operating
position
There are four kinds of fork lever locks. The position of each
roller is different. It is possible to use D4A-E00 through
D4A-E30 levers instead, if they are reversed before attaching.
They can be used with D4A-@@05N models only.
Lights When Not Operating Lights When Operating
Note: 1. The lamp is lit when the actuator is at the free position.
The lamp will be off when the contacts of the Limit
Switch have been actuated and snapped to each other
at the operating position.
2. The lamp is lit when the contacts have been released
and snapped only from the operating position.
(See note 1.) (See note 2.)
2
34
1
Load
Power supply
Built-in switch
Internal circuits
3
4
2
1
Built-in switch
Load
Power supply
Internal circuits
General-pu rpose Limit Switc h D4A-@N 87
Change the lighting mode as follows:
Lever Position
Nameplate
Compatibility with D4A-@
The D4A-@N is compatible with the D4A-@ when the following accessories are attached to the D4A-@N.
Note: The D4A-@N without the above accessor ies is not compatible with the D4A-@.
Push the claw securing
the lamp section to the
right (do not push
strongly).
Remove the
lamp section. Mount the lamp section
so that legend "NC-ON"
or "NO-ON" will appear
in the display window.
Note: In either case, the lamp will
not light when the load is ON.
86.9 to 92.4
73 to 78.5
38.9 to 44.4
67 to 72.5
44.9 to 50.4
59 to 64.5
52.9 to 58.4
D4A-A00 D4A-A10 D4A-A20 D4A-A30
25 to
30.5
The type of switch box is printed.
(The type is also indicated on the
head and receptacle.)
The whole switch model without
lever is printed.
D4A-@
Receptacle box D4A-@N
Switch box D4A-@N
Head
88 General-purpose Limit Switch D4A-@N
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Insert the model number code in @ for the switch body.
3. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Roller Lever Switches
Note: Levers of the side rotary type are optionally available.
SPDT Double-break
DPDT Double-break
The figures in the parentheses are average values.
Model D4A-1@01N D4A-1@02N D4A-1@03N D4A-1@04N D4A-1@05N
OF max. 0.39 N·m 0.39 N·m 0.2 N·m 0.2 N·m 0.39 N·m
RF min. 0.05 N·m 0.05 N·m --- --- ---
PT max. 15° (12°)7° (6°)15° (12°)7° (6°)65° (60°)
OT min. 70°75°70°75°20°
MD max. 5° (4°)4° (3°)5° (4°)4° (3°)35° (30°)
5.2
60.8
70.5
19.138.1
42
62
47.521
75.5
16.5
28
44
59.5±0.2
2.6R
2.6R
29.4±0.2
19 24.5 34
70.5
5.2
42
0.8
6
62.5
48 21
16.5
44
75.5
2.6R
2.6R
29.4±0.2
59.5±0.2
28
29.5
29.5
7.25 dia.
7.25 dia.
Standard
D4A-1@01N, D4A-2@01N
High-sensitivity
D4A-1@02N, D4A-2@02N
Center Neutral Operating
D4A-2@18N
Low T orque
D4A-1@03N, D4A-2@03N
High-sensitivity/Low T orque
D4A-1@04N, D4A-2@04N
Sequential Operation
D4A-2@17N
Maintained
D4A-1@05N, D4A-2@05N
Four, M4 (length: 12)
screws for head
0
5.2+0.2 dia.
mounting holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws for
back-mounting
Four, M4 (length: 12)
screws for head
0
5.2+0.2 dia.
mounting holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws for
back-mounting
Model D4A-2@01N D4A-2@02N D4A-2@03N D4A-2@04N D4A-2@05N D4A-2@17N D4A-2@18N
OF max. 0.39 N·m 0.39 N·m 0.2 N·m 0.2 N·m 0.39 N·m 0.39 N·m 0.39 N·m
RF min. 0.05 N·m 0.05 N·m --- --- --- 0.05 N·m 0.02 N·m
PT max. 15° (12 °)7° (6°)15° (12°)7° (6°)65° (60°) 1-stage: 12° (10°)
2-stage: 20° (17°)19° (15°)
OT min. 70°75°70°75°20°65°65°
MD max. 7° (6°)5° (4°)7° (6°)5° (4°)35° (30°)6° (5°)5° (4°)
General-pu rpose Limit Switc h D4A-@N 89
Side Plunger Switches
6
5.2
44
16.5
28
29.5
75.5
42
19
70.5
0.8
21
OPPT
29.4±0.2
59.5±0.2
2.6R
2.6R
21.531.1
5.2 16.5
28
29.5
44
42
21.5
19 31.1
70.5 75.5
60.8
21
OP
PT
29.4±0.2
59.5±0.2
2.6R
2.6R
42
5.2
60.8
21.5
19 31.1
70.5 75.5
21
16.5
28
29.5
44
OP
PT
59.5±0.2
2.6R
2.6R
29.4±0.2
70.5
19
60.8
21.531.1
5.2
42
75.5
16.5
28
29.5
44
21
59.5±0.2
2.6R
2.6R
OP
PT
29.4±0.2
10 dia.
Standard
D4A-1@06N, D4A-2@06N
Horizontal Roller
D4A-1@07-HN, D4A-2@07-HN
Vertical Roller
D4A-1@07-VN, D4A-2@07-VN
Adjustable
D4A-1@08N, D4A-2@08N
Four, M4 (length: 12)
screws for head
Stainless
steel
plunger
0
5.2
+0.2
dia.
mounting holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws for
back-mounting
Four, M4 (length: 12)
screws for head
11 dia.x 5 stainless
steel roller
0
5.2
+0.2
dia.
mounting holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws
for back-mounting
Four, M4 (length: 12)
screws for head
11 dia.x 5 stainless
steel roller
0
5.2
+0.2
dia.
mounting holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws for
back-mounting
Four, M4 (length: 12)
screws for head
M5 x 0.8 (length: 14
Allen-head bolt
0
5.2
+0.2
dia.
mounting holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws for
back-mounting
Model SPDT double-break DPDT double-break
D4A-1@06N D4A-1@07-HN D4A-1@07-VN D4A-1@08N D4A-2@06N D4A-2@07-HN D4A-2@07-VN D4A-2@08N
OF max. 19.61 N 19.61 N 19.61 N 19.61 N 19.61 N 19.61 N 19.61 N 19.61 N
RF min. 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N
PT max. 2.4 mm 2.4 mm 2.4 mm 2.4 mm 2.4 mm 2.4 mm 2.4 mm 2.4 mm
OT min. 5.1 mm 5.1 mm 5.1 mm 5.1 mm 5.1 mm 5.1 mm 5. 1 mm 5.1 mm
MD max. 0.6 mm 0.6 mm 0.6 mm 0.6 mm 1.0 mm 1.0 mm 1.0 mm 1.0 mm
OP 34±0.8 mm 44±0 .8 mm 44±0.8 mm 41 to 47.5 mm 34±0.8 mm 44±0.8 mm 44±0.8 mm 41 to 47.5 mm
90 General-purpose Limit Switch D4A-@N
Top Plunger Switches
6
42
5.2
70.5
27
0.8
75.5
16.5
28
29.5
44
21
OP
PT
2.6R
2.6R
29.4±0.2
59.5±0.2
6
42
5.2
70.5
27
0.8
16.5
28
29.5
44
21
75.5
2.6R
OP
PT
2.6R
29.4±0.2
59.5±0.2
6
42
5.2
21
75.5
16.5
28
29.5
44
70.5
27 OP
PT
2.6R
2.6R
29.4±0.2
59.5±0.2
0.8
M5 x 0.8 (length:14) Allen-head bolt
11 dia. x 5 stainless steel roller
Stainless steel plunger
10 dia.
Standard
D4A-1@09N, D4A-2@09N
Roller Plunger
D4A-1@10N, D4A-2@10N
Adjustable
D4A-1@11N, D4A-2@11N
Four, M4 (length: 12)
screws for head
0
5.2
+0.2
dia.
mounting holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws for
back-mounting
Four, M4 (length: 12)
screws for head
0
5.2
+0.2
dia.
mounting holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws for
back-mounting
Four, M4 (length: 12)
screws for head
0
5.2
+0.2
dia.
mounting holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws for
back-mounting
Model SPDT double-break DPDT double-break
D4A-1@09N D4A-1@10N D4A-1@11N D4A-2@09N D4A-2@10N D4A-2@11N
OF max. 17.65 N 17.65 N 17.65 N 17.65 N 17.65 N 17.65 N
RF min. 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N
PT max. 1.6 mm 1.6 mm 1.6 mm 1.6 mm 1.6 mm 1.6 mm
OT min. 5.1 mm 5.1 mm 5.1 mm 5.1 mm 5.1 mm 5.1 mm
MD max. 0.4 mm 0.4 mm 0.4 mm 1.0 mm 1.0 mm 1.0 mm
OP 46±0.8 mm 56±0.8 mm 55.5 to 62 mm 46±0.8 mm 56±0.8 mm 55.5 to 62 mm
General-pu rpose Limit Switc h D4A-@N 91
Flexible Rod Switches
(124)
27
0.8
6
42
5.2
93.5 170.5
70.5
16.5
28
29.5
44
75.5
21
PT
2.6R
2.6R
29.4±0.2
59.5±0.2
5.2
42
60.8
27
70.5
(106.5)
150
88.5
44
29.5
28
16.5
75.5
21
PT
2.6R
2.6R
29.4±0.2
59.5±0.2
5.2
42
60.8
88
27
70.5
(287)
44
29.5
28
16.5
75.5
PT
2.6R
2.6R
29.4±0.2
59.5±0.2
21
330
1.4 dia.
Stainless steel wire rod
(see note 1)
(see note 2)
Plastic rod
7 dia.
(see note 1)
(see note 2)
Stainless steel wire rod
8 dia. max.
1.8 dia.
(see note 1)
(see note 2)
Note: 1. The stainless rod can be operated from any direction except the axial direction (i.e., from the top).
2. The optimum operating range of the stainless rod is within 1/3 of the entire length from the top end.
Spring Wire
D4A-1@12N, D4A-2@12N
Plastic Rod
D4A-1@14N, D4A-2@14N
Cat Whisker
D4A-1@15N, D4A-2@15N
Four, M4 (length: 12)
screws for head
0
5.2
+0.2
dia.
mounting
holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws for
back-mounting
Four, M4 (length: 12)
screws for head
0
5.2
+0.2
dia.
mounting holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws for
back-mounting
Four, M4 (length: 12)
screws for head
0
5.2
+0.2
dia.
mounting
holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws for
back-mounting
92 General-purpose Limit Switch D4A-@N
Levers (for Roller Lever Switches)
Note: No D4A-0003N or D4A-0004N head should be used with the adjustable roller lever or mechanical malfunctioning could result because the
total weight of the adjustable roller lever is comparatively large. Use a standard-load head (D4A-0001N or D4A-0002N) instead.
27
0.8
6
42
5.2
70.5
16.5
28
29.5
44
75.5
21
150
(106.5)
PT
2.6R
2.6R
29.4±0.2
59.5±0.2
6.5 dia. Stainless steel coil spring
(see note 1)
(see note 2)
Note: 1. The stainless rod can be operated from any direction except the axial direction (i.e., from the top).
2. The optimum operating range of the stainless rod is within 1/3 of the entire length from the top end.
Coil Spring
D4A-1@16N, D4A-2@16N
Four, M4 (length: 12)
screws for head
0
5.2
+0.2
dia.
mounting holes
Two, M5 (length: 20)
screws for box
1/2-14NPT
conduit
Two, No.10-32UNF
(depth: 10) screws for
back-mounting
Model SPDT double-break DPDT double-break
D4A-1@12N D4A-1@14N
D4A-1@15N D4A-1@16N D4A-2@12N D4A-2@14N
D4A-2@15N D4A-2@16N
OF max. 0.98 N 1.47 N 0.98 N 1.47 N
PT max. 15° (5°)15° (5°)15° (5°)15° (5°)
7.9
38.1
18 39.4
7.9
38.1
18 9 16.5
19.5
38.1
18 9
7.9
11.5
7.9
38.1
18 9
21
15
33.7
18 9
9
M5 Allen bolt
19.1 dia.
7.3 dia.
M5 Allen bolt
19.1 dia.
7.3 dia.
M5 Allen bolt
19.1 dia.
M5 Allen bolt
19.1 dia.
7.3 dia.
M5 Allen bolt
17.5 dia.
7.3 dia.
Note: Stainless sintered roller
(see note)
Note: Stainless sintered roller
Roller Lever
D4A-A00 Roller Lever
D4A-A10 Roller Lever
D4A-A20
Roller Lever
D4A-A30 Roller Lever
D4A-B06
Stainless
sintered
roller
Stainless
sintered
roller
(see
note)
7.3 dia.
Stainless
sintered
roller
General-pu rpose Limit Switc h D4A-@N 93
Note: A Fork Lever Lock can be used with D4A-@@05N models only.
90°
17
38.1
(2)
3.6 7.9
38.1
9
90°
17
(2) 7.9 3.6
38.1
938.1
10.5
160
20
13
7.5
21.2
4.5
113
13
18
21.2 2.5
4.5
147.9
M5 Allen bolt
19.1 dia.
7.3 dia.
19.1 dia.
7.3 dia.
M5 Allen bolt
3 dia.
7.3 dia.
Stainless rod
M5 Allen bolt
6.4 graduation
19.1 dia.
7.3 dia.
M5 Allen bolt
Adjustable Roller Lever
D4A-C00 Adjustable Rod Lever
D4A-D00
Fork Lever Lock
D4A-E30 Fork Lever Lock
D4A-E20
33 to 91
(adjusta-
ble)
Stainless
sintered
roller
150 max.
(adjusta-
ble)
Stainless
sintered
roller
Stainless
sintered
roller
Stainless
sintered
roller
Stainless sintered
roller
(See note.) (See note.)
90°
38.1
(2)
3.6
7.9
9
6.2
38.1
26
22
26
38.1
(2)
3.6
7.9
9
90°
22
6.2
38.1 M5 Allen bolt
19.1 dia.
7.3 dia.
M5 Allen bolt
19.1 dia.
7.3 dia.
Fork Lever Lock
D4A-E10 Fork Lever Lock
D4A-E00
Stainless
sintered
roller
Stainless
sintered
roller
Stainless
sintered
roller
Stainless
sintered
roller
(See note.) (See note.)
M5 Allen bolt
M5 Allen bolt
Nylon
7.3 dia.
25 max.
Nylon Loop Lever
D4A-F00
94 General-purpose Limit Switch D4A-@N
Precautions
Refer to the “Precautions for General-purpose Limit Switches (Including Multiple Limit Switches, Mechanical Touch Switches, High-precision
Switches, Touch Switches, On-site Flexible Switches; Not Including Safety Switches)” on page 17.
Correct Use
Operating Environment
Seal materi al may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts, opera-
tion failure, reduced durability, and other problems. Excessive
vibration or shock can lead to false contact operation or damage.
Install Switches in locations not subject to shock and vibration and
in orientations that will not produce resonance.
The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the con-
tacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near
the Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
Mounting
Tightening Torque
To maintain the high sealing capability of the Limit Swit ch, tighten the
screws for the head and switch bo x with the f ollowing torques:
Head (four 12-mm M4 screws): 1.2 to 1.4 N·m
Switch box (two 20-mm M5 screws): 2.4 to 2.7 N·m
Solderless Terminals
The D4A-@N with DPDT double-break incorporates solderless
terminals.
Operation
The operating methods, cam and dog shapes, operating frequency,
and ov ertravel (OT) have a significant effect on the service life and
accuracy of the Limit Switch. The shape of the cam should be as
smooth as possible.
A marginal ov ertrav el (O T) v alue should be set. The ideal value i s the
rated OT value x 0.7.
The actuator should not be remodeled to change the operating
position.
Connectors
To satisfy IP67, apply sealing tape to the connector conduit.
Appropriate outer diameter of cables is 5.5 to 14 dia.
Use OMRON’s SC-@M Series.
Tighten the Connectors to a torque of 1.8 to 2.2 N·m.
Maintenance and Repair
The user must not maintain or repair equipment incor porat ing any
D4A-N model. Contact the manuf acturer of the equipment for any
maintenance or repairs required.
Tightening Torque
A loose screw may cause malfunctions. Be sure to tighten each
screw to the proper tightening torque as shown in the table.
Model 1/2-14NPT Conduit
D4A-1@@@N
D4A-2@@@N
Fr ont Mountin g
Rear Mounting
(Rear View)
Not Suitable Suitable
59.5±0.15
29.4±0.15
0
Two, 5.2
+0.2
dia. holes
or M5 tapped holes
59.5±0.15
29.4±0.15
0
Two, 6.2+0.2 dia. holes
(Recommended mount-
ing screws: M6.
Switch Box depth: 10.)
General-pu rpose Limit Switc h D4A-@N 95
Note: When using M5 Allen-head bolts, particularly when the head
direction has been changed, check the torque of each screw
and make sure that the screws are free of foreign substances,
and that each screw is tightened to the proper torque.
No. Type Appr opriate tightening
torque
1 Terminal screws (M3.5 screws)
(including grounding terminals) 0.78 to 0.88 N·m
2 Head mounting screws 1.18 to 1.37 N·m
3 Switch box mounting screws 2.35 to 2.75 N·m
4 Body mount ing screws
(See note.) 4.90 to 5.88 N·m
5 Connectors 1.77 to 2.16 N·m
6 Actuator mounting screws 2.45 to 2.65 N·m
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed
part of all quotes, agreements, purchase orders, acknowledgments, price lists,
catalogs, manuals, brochures and other documents, whether electronic or in
writing, relating to the sale of products or services (collectively, the "Products")
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron
objects to any terms or conditions proposed in Buyer’s purchase order or other
documents which are inconsistent with, or in addition to, these Terms.
2. Prices; Payment Terms. All prices stated are current, subject to change with-
out notice by Omron. Omron reserves the right to increase or decrease prices
on any unshipped portions of outstanding orders. Payments for Products are
due net 30 days unless otherwise stated in the invoice.
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices
sent to Buyer after deducting transportation charges, taxes and duties, and will
be allowed only if (i) the invoice is paid according to Omron’s payment terms
and (ii) Buyer has no past due amounts.
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or
the maximum legal rate, whichever is less, on any balance not paid within the
stated terms.
5. Orders. Omron will accept no order less than $200 net billing.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the impor-
tation or sale of the Products.
7. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon,
imposed directly or indirectly on Omron or required to be collected directly or
indirectly by Omron for the manufacture, production, sale, delivery, importa-
tion, consumption or use of the Products sold hereunder (including customs
duties and sales, excise, use, turnover and license taxes) shall be charged to
and remitted by Buyer to Omron.
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Omron, Omron reserves the right to stop shipments or require satisfactory
security or payment in advance. If Buyer fails to make payment or otherwise
comply with these Terms or any related agreement, Omron may (without liabil-
ity and in addition to other remedies) cancel any unshipped portion of Prod-
ucts sold hereunder and stop any Products in transit until Buyer pays all
amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all
unpaid accounts.
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Omron against all related costs or expenses.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:
a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship
except in “break down” situations.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall
constitute delivery to Buyer;
c. All sales and shipments of Products shall be FOB shipping point (unless oth-
erwise stated in writing by Omron), at which point title and risk of loss shall
pass from Omron to Buyer; provided that Omron shall retain a security inter-
est in the Products until the full purchase price is paid;
d. Delivery and shipping dates are estimates only; and
e. Omron will package Products as it deems proper for protection against nor-
mal handling and extra charges apply to special conditions.
12. Claims. Any claim by Buyer against Omron for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing
to Omron within 30 days of receipt of shipment and include the original trans-
portation bill signed by the carrier noting that the carrier received the Products
from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the
Products will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Omron (or such other period expressed
in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Omron further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Products or oth-
erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-
gation hereunder shall be, at Omron’s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
the non-complying Product; provided that in no event shall Omron be responsi-
ble for warranty, repair, indemnity or any other claims or expenses regarding
the Products unless Omron’s analysis confirms that the Products were prop-
erly handled, stored, installed and maintained and not subject to contamina-
tion, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Compa-
nies shall not be liable for the suitability or unsuitability or the results from the
use of Products in combination with any electrical or electronic components,
circuits, system assemblies or any other materials or substances or environ-
ments. Any advice, recommendations or information given orally or in writing,
are not to be construed as an amendment or addition to the above warranty.
See http://oeweb.omron.com or contact your Omron representative for pub-
lished information.
14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual
price of the Product on which liability is asserted.
15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
their employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, inves-
tigation, litigation or proceeding (whether or not Omron is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Products. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Omron and defend or set-
tle any action brought against such Companies to the extent based on a claim
that any Product made to Buyer specifications infringed intellectual property
rights of another party.
16. Property; Confidentiality. Any intellectual property in the Products is the exclu-
sive property of Omron Companies and Buyer shall not attempt to duplicate it
in any way without the written permission of Omron. Notwithstanding any
charges to Buyer for engineering or tooling, all engineering and tooling shall
remain the exclusive property of Omron. All information and materials supplied
by Omron to Buyer relating to the Products are confidential and proprietary,
and Buyer shall limit distribution thereof to its trusted employees and strictly
prevent disclosure to any third party.
17. Export Controls. Buyer shall comply with all applicable laws, regulations and
licenses regarding (i) export of products or information; (iii) sale of products to
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
regulated technology or information.
18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
and no course of dealing between Buyer and Omron shall operate as a waiver
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
without Omron's written consent. (c) Law. These Terms are governed by the
law of the jurisdiction of the home office of the Omron company from which
Buyer is purchasing the Products (without regard to conflict of law princi-
ples). (d) Amendment. These Terms constitute the entire agreement between
Buyer and Omron relating to the Products, and no provision may be changed
or waived unless in writing signed by the parties. (e) Severability
. If any provi-
sion hereof is rendered ineffective or invalid, such provision shall not invalidate
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
against the amount owing in respect of this invoice. (g) Definitions. As used
herein, “including” means “including without limitation”; and “Omron Compa-
nies” (or similar words) mean Omron Corporation and any direct or indirect
subsidiary or affiliate thereof.
Certain Precautions on Specifications and Use
1. Suitability of Use. Omron Companies shall not be responsible for conformity
with any standards, codes or regulations which apply to the combination of the
Product in the Buyer’s application or use of the Product. At Buyer’s request,
Omron will provide applicable third party certification documents identifying
ratings and limitations of use which apply to the Product. This information by
itself is not sufficient for a complete determination of the suitability of the Prod-
uct in combination with the end product, machine, system, or other application
or use. Buyer shall be solely responsible for determining appropriateness of
the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases but the following is a
non-exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Use in consumer products or any use in significant quantities.
(iii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety equip-
ment, and installations subject to separate industry or government regulations.
(iv) Systems, machines and equipment that could present a risk to life or prop-
erty. Please know and observe all prohibitions of use applicable to this Prod-
uct.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-
ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
2. Programmable Products. Omron Companies shall not be responsible for the
user’s programming of a programmable Product, or any consequence thereof.
3. Performance Data. Data presented in Omron Company websites, catalogs
and other materials is provided as a guide for the user in determining suitabil-
ity and does not constitute a warranty. It may represent the result of Omron’s
test conditions, and the user must correlate it to actual application require-
ments. Actual performance is subject to the Omron’s Warranty and Limitations
of Liability.
4. Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our prac-
tice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifica-
tions of the Product may be changed without any notice. When in doubt, spe-
cial part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Omron’s representative at any time
to confirm actual specifications of purchased Product.
5. Errors and Omissions. Information presented by Omron Companies has been
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors or omissions.
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
at www.omron247.com under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ELECTRONICS LLC
1 Commerce Drive
Schaumburg, IL 60173
Tel: 847.843.7900
For U.S. technical support or other
inquiries: 800.556.6766
OMRON CANADA, INC.
885 Milner Avenue
Toronto, Ontario M1B 5V8
Tel: 416.286.6465
MEXICO SALES OFFICES
Mexico, D.F. 555.660.3144
Ciudad Juárez 656.623.7083
Monterrey, N.L. 818.377.4281
Querétaro 442.135.4510
BRAZIL SALES OFFICE
Sao Paulo 55.11.2101.6310
ARGENTINA SALES OFFICE
Cono Sur 54.114.787.1129
CHILE SALES OFFICE
Santiago 562.206.4592
OTHER LATIN AMERICAN SALES
mela@omron.com
OMRON ON-LINE
Global -
www.omron.com
USA -
www.omron247.com
Canada -
www.omron.ca
Brazil -
www.omron.com.br
Latin America -
www.espanol.omron.com
Cat. No. X019-E1-07............................407............Specifications subject to change without notice..............Printed in USA