ADC12048 ADC12048 12-Bit Plus Sign 216 kHz 8-Channel Sampling Analog-to-Digital Converter Literature Number: SNAS105A ADC12048 12-Bit Plus Sign 216 kHz 8-Channel Sampling Analog-to-Digital Converter General Description Operating from a single 5V power supply, the ADC12048 is a 12 bit + sign, parallel I/O, self-calibrating, sampling analog-to-digital converter (ADC) with an eight input fully differential analog multiplexer. The maximum sampling rate is 216 kHz. On request, the ADC goes through a self-calibration process that adjusts linearity, zero and full-scale errors. The ADC12048's 8-channel multiplexer is software programmable to operate in a variety of combinations of single-ended, differential, or pseudo-differential modes. The fully differential MUX and the 12-bit + sign ADC allows for the difference between two signals to be digitized. The ADC12048 can be configured to work with many popular microprocessors/microcontrollers and DSPs including National's HPC family, Intel386 and 8051, TMS320C25, Motorola MC68HC11/16, Hitachi 64180 and Analog Devices ADSP21xx. For complementary voltage references see the LM4040, LM4041 or LM9140. Features n 8-channel programmable Differential or Single-Ended multiplexer n Programmable Acquisition Times and user-controllable Throughput Rates n n n n n Programmable data bus width (8/13 bits) Built-in Sample-and-Hold Programmable Auto-Calibration and Auto-Zero cycles Low power standby mode No missing codes Key Specifications (fCLK = 12 MHz) n Resolution n 13-bit conversion time n 13-bit throughput rate n Integral Linearity Error (ILE) n Single Supply n VIN Range n Power consumption -- Normal operation -- Stand-by mode 12-bits + sign 3.6 s, max 216 ksamples/s, min 1 LSB, max +5V 10% GND to VA+ 34 mW, max 75 w, max Applications n n n n n Medical instrumentation Process control systems Test equipment Data logging Inertial guidance Block Diagram 01238701 TRI-STATE (R) is a registered trademark of National Semiconductor Corporation. (c) 2002 National Semiconductor Corporation DS012387 www.national.com ADC12048 12-Bit Plus Sign 216 kHz 8-Channel Sampling Analog-to-Digital Converter August 2002 ADC12048 Connection Diagrams PLCC Package PQFP Package 01238702 01238703 Order Number ADC12048CIV See NS Package Number V44A Order Number ADC12048CIVF See NS Package Number VGZ44A Ordering Information Industrial Temperature Range Package -40C TA +85C ADC12048CIV PLCC ADC12048CIVF PQFP Pin Description PLCC Pkg. PQFP Pkg. Pin Number Pin Number Pin Name Description 6 44 CH0 7 1 CH1 8 2 CH2 9 3 CH3 15 9 CH4 16 10 CH5 17 11 CH6 18 12 CH7 14 8 COM This pin is another analog input pin used as a pseudo ground when the multiplexer is configured in single-ended mode. 13 7 VREF+ Positive reference input. The operating voltage range for this input is 1V VREF+ VA+ (see Figure 3 and 4). This pin should be bypassed to AGND at least with a parallel combination of a 10 F and a 0.1 F (ceramic) capacitors. The capacitors should be placed as close to the part as possible. www.national.com The eight analog inputs to the Multiplexer. Active channels are selected based on the contents of bits b3-b0 of the Configuration register. Refer to section titled MUX for more details. 2 ADC12048 Pin Description (Continued) PLCC Pkg. PQFP Pkg. Pin Number Pin Number Pin Name Description 12 6 VREF- Negative reference input. The operating voltage range for this input is 0V VREF- VREF+ -1 (see Figure 3 and 4). This pin should be bypassed to AGND at least with a parallel combination of a 10 F and a 0.1 F (ceramic) capacitor. The capacitors should be placed as close to the part as possible. 19 13 MUX OUT- 21 15 MUX OUT+ The inverting (negative) and non-inverting (positive) outputs of the multiplexer. The analog inputs to the MUX selected by bits b3-b0 of the Configuration register appear at these pins. 20 14 ADCIN- 22 16 ADCIN+ 24 18 WMODE The logic state of this pin at power-up determines which edge of the write signal (WR) will latch in data from the data bus. If tied low, the ADC12048 will latch in data on the rising edge of the WR signal. If tied to a logic high, data will he latched in on the falling edge of the WR signal. The state of this pin should not be changed after power-up. 25 19 SYNC The SYNC pin can be programmed as an input or an output. The Configuration register's bit b8 controls the function of this pin. When programmed as an input pin (b8 = 1), a rising edge on this pin causes the ADC's sample-and-hold to hold the analog input signal and begin conversion. When programmed as an output pin (b8 = 0), the SYNC pin goes high when a conversion begins and returns low when completed. 26-31 20-25 D0-D5 34-40 29-34 D6-D12 13-bit Data bus of the ADC12048. D12 is the most significant bit and D0 is the least significant. The BW (bus width) bit of the Configuration register (b12) selects between an 8-bit or 13-bit data bus width. When the BW bit is cleared (BW = 0), D7-D0 are active and D12-D8 are always in TRI-STATE. When the BW bit is set (BW = 1), D12-D0 are active. ADC inputs. The inverting (negative) and non-inverting (positive) inputs into the ADC. 43 37 CLK The clock input pin used to drive the ADC12048. The operating range is 0.05 MHz to 12 MHz. 44 38 WR WR is the active low WRITE control input pin. A logic low on this pin and the CS will enable the input buffers of the data pins D12-D0. The signal at this pin is used by the ADC12048 to latch in data on D12-D0. The sense of the WMODE pin at power-up will determine which edge of the WR signal the ADC12048 will latch in data. See WMODE pin description. 1 39 RD RD is the active low read control input pin. A logic low on this pin and CS will enable the active output buffers to drive the data bus. 2 40 CS CS is the active low Chip Select input pin. Used in conjunction with the WR and RD signals to control the active data bus input/output buffers of the data bus. 3 41 RDY RDY is an active low output pin. The signal at this pin indicates when a requested function has begun or ended. Refer to section Functional Description and the digital timing diagrams for more detail. 4 42 STDBY This is the standby active low output pin. This pin is low when the ADC12048 is in the standby mode and high when the ADC12048 is out of the standby mode or has been requested to leave the standby mode. 10 4 VA+ Analog supply input pin. The device operating supply voltage range is +5V 10%. Accuracy is guaranteed only if the VA+ and VD+ are connected to the same potential. This pin should be bypassed to AGND with a parallel combination of a 10 F and a 0.1 F (ceramic) capacitor. The capacitors should be placed as close to the supply pins of the part as possible. 3 www.national.com ADC12048 Pin Description (Continued) PLCC Pkg. PQFP Pkg. Pin Number Pin Number 11 5 Pin Name Description AGND Analog ground pin. This is the device's analog supply ground connection. It should be connected through a low resistance and low inductance ground return to the system power supply. 32 and 41 26 and 35 VD+ Digital supply input pins. The device operating supply voltage range is +5V 10%. Accuracy is guaranteed only if the VA+ and VD+ are connected to the same potential. This pin should be bypassed to DGND with a parallel combination of a 10 F and a 0.1 F (ceramic) capacitor. The capacitors should be placed as close to the supply pins of the part as possible. 33 and 42 27 and 36 DGND Digital ground pin. This is the device's digital supply ground connection. It should be connected through a low resistance and low inductance ground return to the system power supply. www.national.com 4 ESD Susceptibility (Note 5) (Notes 1, 3.0 kV 2) Operating Ratings (Notes 1, 2, 6, 7, 8, 9) If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications. Supply Voltage (VA+ and VD+) Voltage at all Inputs Temperature Range (Tmin TA Tmax) 6.0V -0.3V to V+ + 0.3V |VA+ - VD+| 300 mV |AGND - DGND| 300 mV 30 mA 120 mA Input Current at Any Pin (Note 3) Package Input Current (Note 3) at TA = 25C 875 mW 100 mV |AGND - DGND| 100 mV GND VIN VA+ VREF+ Input Voltage 1V VREF+ VA+ VREF- Input Voltage 0 VREF- VREF+ - 1V 1V VREF VA+ VREF+ - VREF- Lead Temperature VREF Common Mode (Note 16) VF Package 210C Infared (15 sec.) 4.5V to 5.5V at all Inputs -65C to +150C Vapor Phase (60 sec.) VA+, VD+ |VA+ - VD+| VIN Voltage Range Power Dissipation (Note 4) Storage Temperature -40C TA 85C Supply Voltage 0.1 VA+ VREFCM 0.6 VA+ 220C V Package, Infared (15 sec.) 300C Converter DC Characteristics The following specifications apply to the ADC12048 for VA+ = VD+ = 5V, VREF+ = 4.096V, VREF- = 0.0V, 12-bit + sign conversion mode, fCLK = 12.0 MHz, RS = 25, source impedance for VREF+ and VREF- 1, fully differential input with fixed 2.048V common-mode voltage (VINCM), and minimum acquisition time, unless otherwise specified. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = 25C Symbol Parameter Conditions Typical Limits Unit (Note 10) (Note 11) (Limit) 13 Bits (max) 1 LSB (max) 1 LSB (max) Resolution with No Missing Codes After Auto-Cal ILE Integral Linearity Error After Auto-Cal (Notes 12, 17) DNL Differential Non-Linearity After Auto-Cal Zero Error After Auto-Cal (Notes 13, 17) 0.6 5.5 2.5 5.5 2.5 2.5 5.5 VINCM = 5.0V VINCM = 2.048V VINCM = 0V TUE Positive Full-Scale Error After Auto-Cal (Notes 12, 17) Negative Full-Scale Error After Auto-Cal (Notes 12, 17) DC Common Mode Error After Auto-Cal (Note 14) Total Unadjusted Error After Auto-Cal (Note 18) 1.0 1.0 2 1 LSB (max) LSB (max) LSB (max) LSB (max) LSB (max) LSB (max) LSB Power Supply Characteristics The following specifications apply to the ADC12048 for VA+ = VD+ = 5V, VREF+ = 4.096V, VREF- = 0.0V, 12-bit + sign conversion mode, fCLK = 12.0 MHz, RS = 25, source impedance for VREF+ and VREF- 1, fully differential input with fixed 2.048V common-mode voltage, and minimum acquisition time, unless otherwise specified. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = 25C Symbol PSS Parameter Power Supply Sensitivity Conditions Typical Limits Unit (Note 10) (Note 11) (Limit) VD+ = VA+ = 5.0V 10% (Note 15) Zero Error VREF+ = 4.096V Full-Scale Error VREF- = 0V 0.1 0.5 0.1 Linearity Error 5 LSB LSB LSB www.national.com ADC12048 Absolute Maximum Ratings ADC12048 Power Supply Characteristics (Continued) The following specifications apply to the ADC12048 for VA+ = VD+ = 5V, VREF+ = 4.096V, VREF- = 0.0V, 12-bit + sign conversion mode, fCLK = 12.0 MHz, RS = 25, source impedance for VREF+ and VREF- 1, fully differential input with fixed 2.048V common-mode voltage, and minimum acquisition time, unless otherwise specified. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = 25C Symbol ID+ IA+ IST Parameter VD+ Digital Supply Current VA+ Analog Supply Current Standby Supply Current (ID+ + IA+) Conditions Typical Limits Unit (Note 10) (Note 11) (Limit) 2.8 mA (max) 4.0 mA (max) 5 15 A (max) 100 120 A (max) Start Command (Performing a conversion) with SYNC configured as an input and driven with a 214 kHz signal. Bus width set to 13. fCLK = 12.0 MHz, Reset Mode 850 fCLK = 12.0 MHz, Conversion 2.45 A Start Command (Performing a conversion) with SYNC configured as an input and driven with a 214 kHz signal. Bus width set to 13. fCLK = 12.0 MHz, Reset Mode 2.3 fCLK = 12.0 MHz, Conversion 2.3 mA Standby Mode fCLK = Stopped fCLK = 12.0 MHz Analog MUX Inputs Characteristics The following specifications apply to the ADC12048 for VA+ = VD+ = 5V, VREF+ = 4.096V, VREF- = 0.0V, 12-Bit + sign conversion mode, fCLK = 12.0 MHz, RS = 25, source impedance for VREF+ and VREF+ 1, fully differential input with fixed 2.048V common-mode voltage, and minimum acquisition time, unless otherwise specified. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = 25C Symbol Parameter ION MUX ON Channel Leakage Current IOFF MUX OFF Channel Leakage Current Conditions Typical Limits Unit (Note 10) (Note 11) (Limit) ON Channel = 5V, OFF Channel = 0V 0.05 1.0 A (min) ON Channel = 0V, OFF Channel = 5V -0.05 -1.0 A (max) ON Channel = 5V, OFF Channel = 0V 0.05 1.0 A (min) ON Channel = 0V, OFF Channel = 5V -0.05 -1.0 A (max) IADCIN ADCIN Input Leakage Current 0.05 2.0 A (max) RON MUX On Resistance VIN = 2.5V 310 500 (max) MUX Channel-to-Channel RON Matching VIN = 2.5V 20% CMUX MUX Channel and COM Input Capacitance 10 pF CADC ADCIN Input Capacitance 70 pF CMUXOUT MUX Output Capacitance 20 pF Reference Inputs The following specifications apply to the ADC12048 for VA+ = VD+ = 5V, VREF+ = 4.096V, VREF- = 0.0V, 12-bit + sign conversion mode, fCLK = 12.0 MHz, RS = 25, source impedance for VREF+ and VREF- 1, fully differential input with fixed 2.048V common-mode voltage, and minimum acquisition time, unless otherwise specified. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = 25C Symbol IREF Parameter Reference Input Current www.national.com Conditions Typical Limits Unit (Note 10) (Note 11) (Limit) VREF+ 4.096V, VREF- = 0V Analog Input Signal: 1 kHz 145 A (Note 20) 136 A 80 kHz 6 (Continued) The following specifications apply to the ADC12048 for VA+ = VD+ = 5V, VREF+ = 4.096V, VREF- = 0.0V, 12-bit + sign conversion mode, fCLK = 12.0 MHz, RS = 25, source impedance for VREF+ and VREF- 1, fully differential input with fixed 2.048V common-mode voltage, and minimum acquisition time, unless otherwise specified. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = 25C Symbol CREF Parameter Conditions Typical Limits Unit (Note 10) (Note 11) (Limit) Reference Input Capacitance 85 pF Digital Logic Input/Output Characteristics The following specifications apply to the ADC12048 for VA+ = VD+ = 5V, VREF+ = 4.096V, VREF- = 0.0V, 12-bit + sign conversion mode, fCLK = 12.0 MHz, RS = 25, source impedance for VREF+ and VREF- 1, fully differential input with fixed 2.048V common-mode voltage, and minimum acquisition time, unless otherwise specified. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = 25C Symbol Parameter Conditions Typical Limits (Note 10) Unit (Note 11) (Limit) VIH Logic High Input Voltage VA+ = VD+ = 5.5V 2.0 V (min) VIL Logic Low Input Voltage VA+ = VD+ = 4.5V 0.8 V (max) IIH Logic High Input Current VIN = 5V 0.035 2.0 A (max) IIL Logic Low Input Current VIN = 0V -0.035 -2.0 A (max) VOH Logic High Output Voltage VA+ = VD+ = 4.5V 2.4 V (min) 0.4 V (max) 2.0 A (max) IOUT = -1.6 mA VOL Logic Low Output Voltage VA+ = VD+ = 4.5V IOUT = 1.6 mA IOFF TRI-STATE (R) Output Leakage Current CIN D12-D0 Input Capacitance VOUT = 0V VOUT = 5V 10 pF Converter AC Characteristics The following specifications apply to the ADC12048 for VS+ = VD+ = 5V, VREF+ = 4.096V, VREF- = 0.0V, 12-bit + sign conversion mode, fCLK = 12.0 MHz, RS = 25, source impedance for VREF+ and VREF- 1, fully differential input with fixed 2.048V common-mode voltage, and minimum acquisition time, unless otherwise specified. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = 25C Symbol Parameter tZ Auto Zero Time tCAL Full Calibration Time Conditions Typical CLK Duty Cycle Limits Unit (Note 10) (Note 11) (Limit) 78 78 clks + 120 ns clks (max) 4946 4946 clks + 120 ns clks (max) 40 % (min) 50 % 60 % (max) 44 clks (max) tCONV Conversion Time Sync-Out Mode tAcqSYNCOUT Acquisition Time (Programmable) Minimum for 13 Bits 9 9 clks + 120 ns clks (max) Maximum for 13 Bits 79 79 clks + 120 ns clks (max) 44 Digital Timing Characteristics The following specifications apply to the ADC12048, 13-bit data bus width, VA+ = VD+ = 5V, fCLK = 12 MHz, tf = 3 ns and CL = 50 pF on data I/O lines Symbol tTPR Parameter Throughput Rate Conditions Sync-Out Mode (SYNC Bit = "0") 9 Clock Cycles of Acquisition Time 7 Typical Limits Units (Note 10) (Note 11) (Limit) 222 kHz www.national.com ADC12048 Reference Inputs ADC12048 Digital Timing Characteristics (Continued) The following specifications apply to the ADC12048, 13-bit data bus width, VA+ = VD+ = 5V, fCLK = 12 MHz, tf = 3 ns and CL = 50 pF on data I/O lines Symbol Parameter Conditions Typical Limits Units (Note 10) (Note 11) (Limit) tCSWR Falling Edge of CS to Falling Edge of WR 0 tWRCS Active Edge of WR to Rising Edge of CS 0 tWR WR Pulse Width 20 tWRSETFalling Write Setup Time ns ns 30 ns (min) WMODE = "1" 20 ns (min) tWRHOLDFalling Write Hold Time WMODE = "1" 5 ns (min) tWRSETRising WMODE = "0" 20 ns (min) WMODE = "0" 5 ns (min) Write Setup Time tWRHOLDRising Write Hold Time tCSRD Falling Edge of CS to Falling Edge of RD 0 tRDCS Rising Edge of RD to Rising Edge of CS 0 tRDDATA Falling Edge of RD to Valid Data 8-Bit Mode (BW Bit = "0") 40 58 ns (max) tRDDATA Falling Edge of RD to Valid Data 13-Bit Mode (BW Bit = "1") 26 44 ns (max) tRDHOLD Read Hold Time 23 32 ns (max) tRDRDY Rising Edge of RD to Rising Edge of RDY 24 38 ns (max) tWRRDY Active Edge of WR to Rising Edge of RDY WMODE = "1" 42 65 ns (max) tSTNDBY Active Edge of WR to Falling Edge of STDBY WMODE = "0". Writing the Standby Command into the Configuration Register 200 230 ns (max) Active Edge of WR to Rising Edge of STDBY WMODE = "0". Writing the RESET Command into the Configuration Register 30 45 ns (max) Active Edge of WR to Falling Edge of RDY WMODE = "0". Writing the RESET Command into the Configuration Register 1.4 2.5 ms (max) 5 10 ns (min) tSTDONE tSTDRDY tSYNC Minimum SYNC Pulse Width ns ns Notes on Specifications Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. Note 2: All voltages are measured with respect to GND, unless otherwise specified. Note 3: When the input voltage (VIN) at any pin exceeds the power supply rails (VIN < GND or VIN > (VA+ or VD+)), the current at that pin should be limited to 30 mA. The 120 mA maximum package input current limits the number of pins that can safely exceed the power supplies with an input current of 30 mA to four. Note 4: The maximum power dissipation must he derated at elevated temperatures and is dictated by TJmax, (maximum junction temperature), JA (package junction to ambient thermal resistance), and TA (ambient temperature). The maximum allowable power dissipation at any temperature is PDmax = (TJmax - TA)/JA or the number given in the Absolute Maximum Ratings, whichever is lower. For this device, TJmax = 150C, and the typical thermal resistance (JA) of the ADC12048 in the V package, when board mounted, is 55C/W, and in the VF package, when board mounted, is 67.8C/W. Note 5: Human body model, 100 pF discharged through 1.5 k resistor. Note 6: Each input and output is protected by a nominal 6.5V breakdown voltage zener diode to GND; as shown below, input voltage magnitude up to 0.3V above VA+ or 0.3V below GND will not damage the ADC12048. There are parasitic diodes that exist between the inputs and the power supply rails and errors in the A/D conversion can occur if these diodes are forward biased by more than 50 mV. As an example, if VA+ is 4.50 VDC, full-scale input voltage must be 4.55 VDC to ensure accurate conversions. www.national.com 8 ADC12048 Notes on Specifications (Continued) 01238704 Note 7: VA+ and VD+ must be connected together to the same power supply voltage and bypassed with separate capacitors at each V+ pin to assure conversion/comparison accuracy. Refer to the Power Supply Considerations section for a detailed discussion. Note 8: Accuracy is guaranteed when operating at fCLK = 12 MHz. Note 9: With the test condition for VREF (VREF+ - VREF-) given as +4.096V, the 12-bit LSB is 1.000 mV. Note 10: Typicals are at TA = 25C and represent most likely parametric norm. Note 11: Limits are guaranteed to National's AOQL (Average Outgoing Quality Level). Note 12: Positive integral linearity error is defined as the deviation of the analog value, expressed in LSBs, from the straight line that passes through positive full-scale and zero. For negative integral linearity error, the straight line passes through negative full-scale and zero. Note 13: Zero error is a measure of the deviation from the mid-scale voltage (a code of zero), expressed in LSB. It is the average value of the code transitions between -1 to 0 and 0 to +1 (see Figure 8). Note 14: The DC common-mode error is measured with both inputs shorted together and driven from 0V to 5V. The measured value is referred to the resulting output value when the inputs are driven with a 2.5V input. Note 15: Power Supply Sensitivity is measured after an Auto-Zero and Auto Calibration cycle has been completed with VA+ and VD+ at the specified extremes. Note 16: VREFCM (Reference Voltage Common Mode Range) is defined as Note 17: The ADC12048's self-calibration technique ensures linearity and offset errors as specified, but noise inherent in the self-calibration process will result in a repeatability uncertainly of 0.20 LSB. Note 18: Total Unadjusted Error (TUE) includes offset, full scale linearity and MUX errors. Note 19: The ADC12048 parts used to gather the information for these curves were auto-calibrated prior to taking the measurements at each test condition. The auto-calibration cycle cancels any first order drifts due to test conditions. However, each measurement has a repeatability uncertainty error of 0.2 LSB. See (Note 17). Note 20: The reference input current is a DC average current drawn by the reference input with a full-scale sinewave input. The ADC12048 is continuously converting with a throughput rate of 206 kHz. Note 21: These typical curves were measured during continuous conversions with a positive half-scale DC input. A 240 ns RD pulse was applied 25 ns after the RDY signal went low. The data bus lines were loaded with 2 HC family CMOS inputs (CL 20 pF). Note 22: Any other values placed in the command field are meaningless. However, if a code of 101 or 110 is placed in the command field and the CS, RD and WR go low at the same time, the ADC12048 will enter a test mode. These test modes are only to be used by the manufacturer of this device. A hardware power-off and power-on reset must be done to get out of these test modes. 9 www.national.com ADC12048 Electrical Characteristics 01238705 FIGURE 1. Output Digital Code vs the Operating Input Voltage Range (General Case) 01238706 FIGURE 2. Output Digital Code vs the Operating Input Voltage Range for VREF = 4.096V www.national.com 10 ADC12048 Electrical Characteristics (Continued) 01238707 FIGURE 3. VREF Operating Range (General Case) 01238708 FIGURE 4. VREF Operating Range for VA = 5V 11 www.national.com ADC12048 Electrical Characteristics (Continued) 01238709 FIGURE 5. Transfer Characteristic 01238710 FIGURE 6. Simplified Error vs Output Code without Auto-Calibration or Auto-Zero Cycles www.national.com 12 ADC12048 Electrical Characteristics (Continued) 01238711 FIGURE 7. Simplified Error vs Output Code after Auto-Calibration Cycle 01238712 FIGURE 8. Offset or Zero Error Voltage (Note 13) 13 www.national.com ADC12048 Timing Diagrams 01238713 FIGURE 9. Sync-Out Write (WMODE = 1, BW = 1), Read and Convert Cycles 01238714 FIGURE 10. Sync-In Write (WMODE = 1, BW = 1), Read and Convert Cycles www.national.com 14 ADC12048 Timing Diagrams (Continued) 01238746 FIGURE 11. Sync-Out Write (WMODE = 0, BW = 1), Read and Convert Cycles 01238747 FIGURE 12. Sync-In Write (WMODE = 0, BW = 1), Read and Convert Cycles 15 www.national.com ADC12048 Timing Diagrams (Continued) 01238748 FIGURE 13. Sync-Out Read and Convert Cycles. The MUX channel is the channel selected on the most recent write cycle. 01238749 FIGURE 14. Sync-In Read and Convert Cycles. The MUX channel is the channel selected on the most recent write cycle. www.national.com 16 ADC12048 Timing Diagrams (Continued) 01238750 FIGURE 15. 8-Bit Bus Read Cycle (Sync-Out) 01238751 FIGURE 16. 8-Bit Bus Read Cycle (Sync-In) 17 www.national.com ADC12048 Timing Diagrams (Continued) 01238715 FIGURE 17. Write Signal Negates RDY (Writing the Standby, Auto-Cal or Auto-Zero Command) 01238716 FIGURE 18. Standby and Reset Timing (13-Bit Data Bus Width) www.national.com 18 (See (Note 19), Electrical Characteristic Section) Integral Linearity Error (INL) Change vs. Clock Frequency Full-Scale Error Change vs. Clock Frequency 01238718 01238717 Zero Error Change vs. Clock Frequency Integral Linearity Error (INL) Change vs. Temperature 01238720 01238719 Full-Scale Error Change vs. Temperature Zero Error Change vs. Temperature 01238721 01238722 19 www.national.com ADC12048 Typical Performance Characteristics ADC12048 Typical Performance Characteristics (See (Note 19), Electrical Characteristic Section) Integral Linearity Error (INL) Change vs. Reference Voltage (Continued) Full-Scale Error Change vs. Reference Voltage 01238724 01238723 Zero Error Change vs. Reference Voltage Integral Linearity Error (INL) Change vs. Supply Voltage 01238725 01238739 Full-Scale Error Change vs. Supply Voltage Zero Error Change vs. Supply Voltage 01238741 01238740 www.national.com 20 ADC12048 Typical Performance Characteristics (See (Note 21), Electrical Characteristic Section) Supply Currents vs. Clock Frequency Reference Currents vs. Clock Frequency 01238742 01238743 Analog Supply Current vs. Temperature Digital Supply Current vs. Temperature 01238744 01238745 Full Scale Differential 1,099 Hz Sine Wave Input Full Scale Differential 18,677 Hz Sine Wave Input 01238726 01238727 21 www.national.com ADC12048 Typical Performance Characteristics (See (Note 21), Electrical Characteristic Section) Full Scale Differential 38,452 Hz Sine Wave Input (Continued) Full Scale Differential 79,468 Hz Sine Wave Input 01238728 01238729 Half Scale Differential 20 kHz Sine Wave Input, fS = 153.6 kHz Half Scale Differential 1 kHz Sine Wave Input, fS = 153.6 kHz 01238730 01238731 Half Scale Differential 75 kHz Sine Wave Input, fS = 153.6 kHz Half Scale Differential 40 kHz Sine Wave Input, fS = 153.6 kHz 01238733 01238732 www.national.com 22 ADC12048 Register Bit Description CONFIGURATION REGISTER (Write Only) of this register cannot be read. This is a 13-bit write-only register that is used to program the functionality of the ADC12048. All data written to the ADC12048 will always go to this register only. The contents MSB b12 BW LSB b11 b10 b9 COMMAND FIELD b8 b7 b6 b5 SYNC HB SE ACQ TIME b4 b3 b2 b1 b0 MUX ADDRESS connect to the MUXOUT+ and MUXOUT- pins. (Refer to the MUX section for more details on the MUX.) Power-up value is 0000. Power on State: 0100Hex b3-b0: The MUX ADDRESS bits configure the analog input MUX. They select which input channels of the MUX will TABLE 1. MUX Channel Assignment b3 b2 b1 b0 MUXOUT+ MUXOUT- 0 0 0 0 CH0 CH1 0 0 0 1 CH1 CH0 0 0 1 0 CH2 CH3 0 0 1 1 CH3 CH2 0 1 0 0 CH4 CH5 0 1 0 1 CH5 CH4 0 1 1 0 CH6 CH7 0 1 1 1 CH7 CH6 1 0 0 0 CH0 COM 1 0 0 1 CH1 COM 1 0 1 0 CH2 COM 1 0 1 1 CH3 COM 1 1 0 0 CH4 COM 1 1 0 1 CH5 COM 1 1 1 0 CH6 COM 1 1 1 1 CH7 COM b5-b4: The ACQ TIME bits select one of four possible acquistion times in SYNC-OUT mode. (Refer to Selectable Acquisition Time section.) b5 b4 0 0 9 0 1 15 1 0 47 1 1 79 b6: When the Single-Ended bit (SE bit) is set, conversion results will be limited to positive values only and any negative conversion results will appear as a code of zero in the Data register. The SE bit is cleared at power-up. b7: The High Byte bit (HB) is meaningful only in 8-bit mode (BW bit b12 = "0") and is a don't care condition in 13-bit mode (BW bit b12 = "1"). This bit is used to access the upper byte of the Configuration Register in 8-bit mode. When this bit is set and bit b12 = 0, the next byte written to the ADC12048 will program the upper byte of the Configuration register. The HB bit will automatically be cleared when data is written to the upper byte of the Configuration register, allowing the lower byte to be accessed with the next write. The HB bit is cleared at power-up. Clocks b8: The SYNC bit. When the SYNC bit is set, the SYNC pin is programmed as an input and the converter is in synchronous mode. In this mode a rising edge on the SYNC pin causes the ADC to hold the input signal and begin a conversion. When b15 cleared, the SYNC pin is programmed as an output and the converter is in an asynchronous mode. In this mode the signal at the SYNC pin indicates the status of the converter. The SYNC pin is high when a conversion is taking place. The SYNC bit is set at power-up. b11-b9: The command field. These bits select the mode of operation of the ADC12048. Power-up value is 000. (See (Note 22)) 23 www.national.com ADC12048 Register Bit Description (Continued) b11 b10 b9 0 0 0 Standby command. This puts the ADC in a low power consumption mode Command 0 0 1 Ful-Cal command. This will cause the ADC to perform a self-calibrating cycle that will correct linearity and zero errors. 0 1 0 Auto-zero command. This will cause the ADC to perform an auto-zero cycle that corrects offset errors. 0 1 1 Reset command. This puts the ADC in an idle mode. 1 0 0 Start command. This will put the converter in a start mode, preparing it to perform a conversion. If in asynchronous mode (b8 = "0"), conversions will immediately begin after the programmed acquisition time has ended. In synchronous mode (b8 = "1"), conversions will begin after a rising edge appears on the SYNC pin. b12: This is the Bus Width (BW) bit. When this bit is a '0' the ADC12048 is configured to interface with an 8-bit data bus; data pins D7-D0 are active and pins D12-D9 are in TRI-STATE. When the BW bit is a '1', the ADC12048 is configured to interface with a 16-bit data bus and data pins D13-D0 are all active. The BW bit is a '0' at power-up. register on the data bus. When reading the data register in 8-bit mode, the sign bit is extended (b12 through b8 all contain the sign bit). DATA REGISTER (Read Only) This is a 13-bit read only register that holds the 12-bit +sign conversion result in two's compliment form. All reads performed from the ADC12048 will place the contents of this MSB b12 LSB b11 b10 b9 b8 sign b7 b6 b4 b3 b2 b1 b0 Conversion Data Power on State: 0000Hex b11-b0: b11 is the most significant bit and b0 is the least significant bit of the conversion result. b12: This bit contains the sign of the conversion result: 0 for positive results and 1 for negative. used to access the upper byte. If the HB bit is set with a write to the lower byte, the next byte written to the ADC will be placed in the upper byte of the Configuration register. After data is written to the upper byte of the Configuration register, the HB bit will automatically be cleared, causing the next byte written to the ADC to go to the lower byte of the Configuration register. When reading the ADC in 8-bit mode, the first read cycle places the lower byte of the Data register on the data bus followed by the upper byte during the next read cycle. Functional Description The ADC12048 is programmed through a digital interface that supports an 8-bit or 16-bit data bus. The digital interface consists of a 13-bit data input/output bus (D12-D0), digital control signals and two internal registers: a write only 13-bit Configuration register and a read only 13-bit Data register. The Configuration register programs the functionality of the ADC12048. The 13 bits of the Configuration register are divided into 7 fields. Each field controls a specific function of the ADC12048: the channel selection of the MUX, the acquisition time, synchronous or asynchronous conversions, mode of operation and the data bus size. In 13-bit mode the HB bit is a don't care condition and all bits of the data register and Configuration register are accessible with a single read or write cycle. Since the bus width of the ADC12048 defaults to 8 bits after power-up, the first action when 13-bit mode is desired must be set to the bus width to 13 bits. WMODE The WMODE pin is used to determine the active edge of the write pulse. The state of this pin determines which edge of the WR signal will cause the ADC to latch in data. This is processor dependent. If the processor has valid data on the bus during the falling edge of the WR signal, the WMODE pin must be tied to VD+. This will cause the ADC to latch the data on the falling edge of the WR signal. If data is valid on the rising edge of the WR signal, the WMODE pin must be tied to DGND causing the ADC to latch in the data on the rising edge of the WR signal. Features and Operating Modes SELECTABLE BUS WIDTH The ADC12048 can be programmed to interface with an 8-bit or 16-bit data bus. The BW bit (b12) in the Configuration register controls the bus size. The bus width is set to 8 bits (D7-D0 are active and D12-D8 are in TRI-STATE) if the BW bit is cleared or 13 bits (D12-D0 are active) if the BW bit is set. At power-up the bus width defaults to 8 bits and any initial programming of the ADC12048 should take this into consideration. In 8-bit mode the Configuration register is byte accessible. The HB bit in the lower byte of the Configuration register is www.national.com b5 INPUT MULTIPLEXER The ADC12048 has an eight channel input multiplexer with a COM input that can be used in a single-ended, pseudo-differential or fully-differential mode. The MUX select 24 the sample/hold circuit (2500 typical) and the effective output resistance of the source. For conversion results to be accurate, the period during which the sampling capacitor is connected to the source (the "acquisition time") must be long enough to charge the capacitor to within a small fraction of an LSB of the input voltage. An acquisition time of 750 ns is sufficient when the external source resistance is less than 1 k and any active or reactive source circuitry settles to 12 bits in less than 500 ns. When source resistance or source settling time increase beyond these limits, the acquisition time must also be increased to preserve precision. In asynchronous (SYNC-OUT) mode, the acquisition time is controlled by an internal counter. The minimum acquisition period is 9 clock cycles, which corresponds to the nominal value of 750 ns when the clock frequency is 12 MHz. Bits b4 and b5 of the Configuration Register are used to select the acquisition time from among four possible values (9, 15, 47, or 79 clock cycles). Since acquisition time in the asynchronous mode is based on counting clock cycles, it is also inversely proportional to clock frequency: (Continued) bits (b3-b0) in the Configuration register determine which channels will appear at the MUXOUT+ and MUXOUT- multiplexer output pins. (Refer to Register Bit Description Section.) Analog signal conditioning with fixed-gain amplifiers, programmable-gain amplifiers, filters and other processing circuits can be used at the output of the multiplexer before being applied to the ADC inputs. The ADCIN+ and ADCIN- are the fully differential non-inverting (positive) and inverting (negative) inputs to the analog-to-digital converter (ADC) of the ADC12048. If no external signal conditioning is required on the signal output of the multiplexer, MUXOUT+ should be connected to ADCIN+ and MUXOUT- should be connected to ADCIN-. The analog input multiplexer can be set up to operate in either one of eight differential or eight single-ended (the COM input as the zero reference) modes. In the differential mode, the analog inputs are paired as follows: CH0 with CH1, CH2 with CH3, CH4 with CH5 and CH6 with CH7. The input channel pairs can be connected to the MUXOUT+ and MUXOUT- pins in any order. In the single-ended mode, one of the input channels, CH0 through CH7, can be assigned to MUXOUT+ while the MUXOUT- is always assigned to the COM input. Note that the actual acquisition time will be longer than TACQ because acquisition begins either when the multiplexer channel is changed or when RDY goes low, if the multiplexer channel is not changed. After a read is performed, RDY goes high, which starts the TACQ counter (see Figure 9). In synchronous (SYNC-IN) mode, bits b4 and b5 are ignored, and the acquisition time depends on the sync signal applied at the SYNC pin. If a new MUX channel is selected at the start of the conversion, the acquisition period begins on the active edge of the WR signal that latches in the new MUX channel. If no new MUX channel is selected, the acquisition period begins on the falling edge of RDY, which occurs at the end of the previous conversion (or at the end of an autozero or autocalibration procedure). The acquisition period ends when SYNC goes high. To estimate the acquisition time necessary for accurate conversions when the source resistance is greater than 1 k, use the following expression: STANDBY MODE The ADC12048 has a low power consumption mode (75 W @ 5V). This mode is entered when a Standby command is written in the command field of the Configuration register. A logic low appearing on the STDBY output pin indicates that the ADC12048 is in the Standby mode. Any command other than the Standby command written to the Configuration register will get the ADC12048 out of the Standby mode. The STDBY pin will immediately switch to a logic "1" as soon as the ADC12048 is requested to get out of the standby mode. The RDY pin will then be asserted low when the ADC is actually out of the Standby mode and ready for normal operation. The ADC12048 defaults to the Standby mode following a hardware power-up. This can be verified by examining the logic low status of the STDBY pin. SYNC/ASYNC MODE The ADC12048 may be programmed to operate in synchronous (SYNC-IN) or asynchronous (SYNC-OUT) mode. To enter synchronous mode, the SYNC bit in the Configuration register must be set. The ADC12048 is in synchronous mode after a hardware power-up. In this mode, the SYNC pin is programmed as an input and conversions are synchronized to the rising edges of the signal applied at the SYNC pin. Acquisition time can also be controlled by the SYNC signal when in synchronous mode. Refer to the sync-in timing diagrams. When the SYNC bit is cleared, the ADC is in asynchronous mode and the SYNC pin is programmed as an output. In asynchronous mode, the signal at the SYNC pin indicates the status of the converter. This pin is high when the converter is performing a conversion. Refer to the sync-out timing diagrams. where RS is the source resistance, RM is the MUX "On" resistance, and RS/H is the sample/hold "On" resistance. If the settling time of the source is greater than 500 ns, the acquisition time should be about 300 ns longer than the settling time for a "well-behaved", smooth settling characteristic. FULL CALIBRATION CYCLE A full calibration cycle compensates for the ADC's linearity and offset errors. The converter's DC specifications are guaranteed only after a full calibration has been performed. A full calibration cycle is initated by writing a Ful-Cal command to the ADC12048. During a full calibration, the offset SELECTABLE ACQUISITION TIME The ADC12048's internal sample/hold circuitry samples an input voltage by connecting the input to an internal sampling capacitor (approximately 70 pF) through an effective resistance equal to the multiplexer "On" resistance (300 max) plus the "On" resistance of the analog switch at the input to 25 www.national.com ADC12048 Features and Operating Modes ADC12048 Features and Operating Modes STARTING A CONVERSION: START COMMAND In order to completely describe the events associated with the Start command, both the SYNC-OUT and SYNC-IN modes must be considered. (Continued) error is measured eight times, averaged and a correction coefficient is created. The offset correction coefficient is stored in an internal offset correction register. The overall Iinearity correction is achieved by correctng the internal DAC's capacitor mismatches. Each capacitor is compared eight times against all remaining smaller value capacitors. The errors are averaged and correction coefficients are created. SYNC-OUT/Asynchronous 8-bit mode: The first byte written to the ADC12048 should set the MUX channel, the acquisition time and the HB bit. The second byte should clear the SYNC bit, write the START command and clear the BW bit. In order to initiate a conversion, two reads must be performed from the ADC12048. The rising edge of the second read pulse will force the RDY pin high and begin the programmed acquisition time selected by bits b5 and b4 of the configuration register. The SYNC pin will go high indicating that a conversion sequence has begun following the end of the acquisition period. The RDY and SYNC signal will fall low when the conversion is done. At this time new information, such as a new MUX channel, acquisition time and operational command can be written into the configuration register or it can remain unchanged. Assuming that the START command is in the Configuration register, the previous conversion can be read. The first read places the lower byte of the conversion result contained in the Data register on the data bus. The second read will place the upper byte of the conversion result stored in the Data register on the data bus. The rising edge on the second read pulse will begin another conversion sequence and raise the RDY and SYNC signals appropriately. 13-bit mode: The MUX channel and the acquisition time should be set, the SYNC bit cleared and the START command issued with a single write to the ADC12048. In order to initiate a conversion, a single read must be performed from the ADC12048. The rising edge of the read signal will force the RDY signal high and begin the programmed acquisition time selected by bits b5 and b4 of the configuration register. The SYNC pin will go high indicating that a conversion sequence has begun following the end of the acquisition period. The RDY and SYNC signal will fall low when the conversion is done. At this time new information, such as a new MUX channel, acquisition time and operational command can be written into the configuration register or it can remain unchanged. With the START command in the Configuration register, a read from the ADC12048 will place the entire 13-bit conversion result stored in the data register on the data bus. The rising edge of the read pulse will immediately force the RDY output high. The SYNC will then go high following the elapse of the programmed acquisition time in the configuration register's bits b5 and b4. SYNC-IN/Synchronous For the SYNC-IN case, it is assumed that a series of SYNC pulses at the desired sampling rate are applied at the SYNC pin of the ADC12048. 8-bit mode: The first byte written to the ADC12048 should set the MUX channel and the HB bit. The second byte should set the SYNC bit, write the START command and clear the BW bit. A rising edge on the SYNC pin or the second rising edge of two consecutive reads from the ADC12048 will force the RDY signal high. It is recommended that the action of reading from the ADC12048 (not the rising edge of the SYNC signal) be used to raise the RDY signal. In the SYNC-IN mode, only the rising edge of the SYNC signal will begin a conversion cycle. The rising edge of the SYNC also ends the acquisition period. The acquisition period begins following a write cycle containing MUX channel information. The selected MUX channel is sampled after the rising edge of the Once the converter has been calibrated, an arithmetic logic unit (ALU) uses the offset and linearity correction coefficients to reduce the conversion offset and linearity errors to within guaranteed limits. AUTO-ZERO CYCLE During an auto-zero cycle, the offset is measured only once and a correction coefficient is created and stored in an internal offset register. An auto-zero cycle is initiated by writing an Auto-Zero command to the ADC12048. DIGITAL INTERFACE The digital control signals are CS, RD, WR, RDY and STDBY. Specific timing relationships are associated with the interaction of these signals. Refer to the Digital Timing Diagrams section for detailed timing specifications. The active low RDY signal indicates when a certain event begins and ends. It is recommended that the ADC12048 should only be accessed when the RDY signal is low. It is in this state that the ADC12048 is ready to accept a new command. This will minimize the effect of noise generated by a switching data bus on the ADC. The only exception to this is when the ADC12048 is in the standby mode at which time the RDY is high and the STDBY signal is low. The ADC12048 is in the standby mode at power up or when a STANDBY command is issued. A Ful-Cal, Auto-Zero, Reset or Start command will get the ADC12048 out of the standby mode. This may be observed by monitoring the status of the RDY and STDBY signals. The RDY signal will go low and the STDBY signal high when the ADC12048 leaves the standby mode. The following describes the state of the digital control signals for each programmed event in both 8-bit and 13-bit mode. RDY should be low before each command is issued except for the case when the device is in standby mode. FUL-CAL OR AUTO-ZERO COMMAND 8-bit mode: The first write to the ADC12048 will place the data in the lower byte of the Configuration register. This byte must set the HB bit (b7) to allow access to the upper byte of the Configuration register during the next write cycle. During the second write cycle, the Ful-Cal or Auto-Zero command must be issued. The edge of the second write pulse on the WR pin will force the RDY signal high. At this time the converter begins executing a full calibration or auto-zero cycle. The RDY signal will automatically go low when the full calibration or auto-zero cycle is done. 13-bit mode: In a single write cycle the Ful-Cal or Auto-Zero command must be written to the ADC12048. The edge of the WR signal will force the RDY high. At this time the converter begins executing a full calibration or auto-zero cycle. The RDY signal will automatically go low when the full calibration or auto-zero cycle is done. www.national.com 26 a conversion, full-calibration or auto-zero cycle. It can also be used to get the ADC12048 out of the standby mode. (Continued) Analog Application Information WR signal until the rising edge of the SYNC pulse, at which time the signal will be held and conversion begins. The RDY signal will go low when the conversion is done. A new MUX channel and/or operational command may be written into the Configuration register at this time, if needed. Two consecutive read cycles are required to retrieve the entire 13-bit conversion result from the ADC12048's data register. The first read will place the lower byte of the conversion result contained in the Data register on the data bus. The second read will place the upper byte of the conversion result stored in the Data register on the data bus. With the START command in the configuration register, the rising edge of the second read pulse will raise the RDY signal high and begin a conversion cycle following a rising edge on the SYNC pin. REFERENCE VOLTAGE The ADC12048 has two reference inputs, VREF+ and VREF-. They define the zero to full-scale range of the analog input signals over which 4095 positive and 4096 negative codes exist. The reference inputs can be connected to span the entire supply voltage range (VREF- = AGND, VREF+ = VA+) or they can be connected to different voltages when other input spans are required. The reference inputs of the ADC12048 have transient capacitive switching currents. The voltage sources driving VREF+ and VREF- must have very low output impedence and noise and must be adequately bypassed. The circuit in Figure 20 is an example of a very stable reference source. The ADC12048 can be used in either ratiometric or absolute reference appplications. In ratiometric systems, the analog input voltage is proportional to the voltage used for the ADC's reference voltage. This technique relaxes the system reference requirements because the analog input voltage moves with the ADC's reference. The system power supply can be used as the reference voltage by connecting the VREF+ pin to VA+ and the VREF- pin to AGND. For absolute accuracy, where the analog input voltage varies between very specific voltage limits, a time and temperature stable voltage source can be connected to the reference inputs. Typically, the reference voltage's magnitude will require an initial adjustment to null reference voltage induced full-scale errors. The reference voltage inputs are not fully differential. The ADC12048 will not generate correct conversions if (VREF+) - (VREF-) is below 1V. Figure 19 shows the allowable relationship between VREF+ and VREF-. 13-bit mode: The MUX channel should be selected, the SYNC bit should be set and the START command issued with a single write to the ADC12048. A rising edge on the SYNC pin or on the RD pin will force the RDY signal high. It is recommended that the action of reading from the ADC12048 (not the rising edge of the SYNC signal) be used to raise the RDY signal. This will ensure that the conversion result is read during the acquisition period of the next conversion cycle, eliminating a read from the ADC12048 while it is performing a conversion. Noise generated by accessing the ADC12048 while it is converting may degrade the conversion result. In the SYNC-IN mode, only the rising edge of the SYNC signal will begin a conversion cycle. The RDY signal will go low when the conversion cycle is done. The acquisition time is controlled by the SYNC signal. The acquisition period begins following a write cycle containing MUX channel information. The selected MUX channel is sampled after the rising edge of the WR signal until the rising edge of the SYNC pulse, at which time the signal will be held and conversion begins. A new MUX channel and/or operational command may be written into the Configuration register at this time, if needed. With the START command in the Configuration register, a read from the ADC12048 will place the entire conversion result stored in the Data register on the data bus and the rising edge of the read pulse will force the RDY signal high. The selected MUX channel will be sampled until a rising edge appears on the SYNC pin, at which the time sampled signal will be held and a conversion cycle started. STANDBY COMMAND 8-bit mode: The first byte written to the ADC12048 should set the HB bit in the Configuration register (bit b7). The second byte must issue the Standby command (bits b11, b10, b9 = 0, 0, 0). 13-bit mode: The Standby command must be issued to the ADC12048 in single write (bits b11, b10, b9 = 0, 0, 0). 01238737 RESET The RESET command places the ADC12048 into a ready state and forces the RDY signal low. The RESET command can be used to interrupt the ADC12048 while it is performing FIGURE 19. VREF Operating Range 27 www.national.com ADC12048 Features and Operating Modes ADC12048 Analog Application Information (Continued) 01238736 *Tantalum **Ceramic FIGURE 20. Low Drift Extremely Stable Reference Circuit Part Number Output Voltage Temperature Tolerance Coefficient 0.5% 0.1% 0.2% 0.1% 0.5% LM4041CI-Adj LM4040AI-4.1 LM4050 LM4121 LM9140BYZ-4.1 Circuit of Figure 20 Adjustable creased to allow the charging current to settle within specified limits. In asynchronous mode, the acquisition time may be increased to 15, 47 or 79 clock cycles. If different acquisition times are needed, the synchronous mode can be used to fully control the acquisition time. OUTPUT DIGITAL CODE VERSUS ANALOG INPUT VOLTAGE The ADC12048's fully differential 12-bit + sign ADC generates a two's complement output that is found by using the equation shown below: INPUT BYPASS CAPACITANCE External capacitors (0.01 F-0.1 F) can be connected between the analog input pins (CH0-CH7) and the analog ground to filter any noise caused by inconductive pickup associated with long leads. Round off the result to the nearest integer value between -4096 and 4095. POWER SUPPLY CONSIDERATIONS Decoupling and bypassing the power supply on a high resolution ADC is an important design task. Noise spikes on the VA+ (analog supply) or VD+ (digital supply) can cause conversion errors. The analog comparator used in the ADC will respond to power supply noise and will make erroneous conversion decisions. The ADC is especially sensitive to power supply spikes that occur during the auto-zero or linearity calibration cycles. The ADC12048 is designed to operate from a single +5V power supply. The separate supply and ground pins for the analog and digital portions of the circuit allow separate external bypassing. To minimize power supply noise and ripple, adequate bypass capacitors should be placed directly between power supply pins and their associated grounds. Both supply pins should be connected to the same supply source. In systems with separate analog and digital supplies, the ADC should be powered from the analog supply. At least a INPUT CURRENT At the start of the acquisition window (tAcqSYNOUT) a charging current (due to capacitive switching) flows through the analog input pins (CH0-CH7, ADCIN+ and ADCIN-, and the COM). The peak value of this input current will depend on the amplitude and frequency of the input voltage applied, the source impedance and the input switch ON resistance. With the MUXOUT+ connected to the ADCIN+ and the MUXOUT- connected to the ADCIN- the on resistance is typically 2800. Bypassing the MUX and using just the ADCIN+ and ADCIN- inputs the on resistance is typically 2500. For low impedance voltage sources ( < 1000 for 12 MHz operation), the input charging current will decay to a value that will not introduce any conversion errors before the end of the default sample-and-hold (S/H) acquisition time (9 clock cycles). For higher source impedances ( > 1000 for 12 MHz operation), the S/H acquisition time should be inwww.national.com 100ppm/C 100ppm/C 50ppm/C 50ppm/C 25ppm/C 2ppm/C 28 shows a layout using a 44-pin PLCC socket and through-hole assembly. A similar approach should be used for the PQFP package. The analog ground plane should encompass the area under the analog pins and any other analog components such as the reference circuit, input amplifiers, signal conditioning circuits, and analog signal traces. (Continued) 10 F tantalum electrolytic capacitor in parallel with a 0.1 F monolithic ceramic capacitor is recommended for bypassing each power supply. The key consideration for these capacitors is to have low series resistance and inductance. The capacitors should be placed as close as physically possible to the supply and ground pins with the smaller capacitor closer to the device. The capacitors also should have the shortest possible leads in order to minimize series lead inductance. Surface mount chip capacitors are optimal in this respect and should be used when possible. The digital ground plane should encompass the area under the digital circuits and the digital input/output pins of the ADC12048. Having a continuous digital ground plane under the data and clock traces is very important. This reduces the overshoot/undershoot and high frequency ringing on these lines that can be capacitively coupled to analog circuitry sections through stray capacitances. When the power supply regulator is not local on the board, adequate bypassing (a high value electrolytic capacitor) should be placed at the power entry point. The value of the capacitor depends on the total supply current of the circuits on the PC board. All supply currents should be supplied by the capacitor instead of being drawn from the external supply lines, while the external supply charges the capacitor at a steady rate. The ADC has two VD+ and DGND pins. It is recommended that each of these VD+ pins be separately bypassed to DGND with a 0.1 F plus a 10 F capacitor. The layout diagram of Figure 21 shows the recommended placement for the supply bypass capacitors. The AGND and DGND in the ADC12048 are not internally connected together. They should be connected together on the PC board right at the chip. This will provide the shortest return path for the signals being exchanged between the internal analog and digital sections of the ADC. It is also a good design practice to have power plane layers in the PC board. This will improve the supply bypassing (an effective distributed capacitance between power and ground plane layers) and voltage drops on the supply lines. However, power planes are not as essential as ground planes are for satisfactory performance. If power planes are used, they should be separated into two planes and the area and connections should follow the same guidelines as mentioned for the ground planes. Each power plane should be laid out over its associated ground planes, avoiding any overlap between power and ground planes of different types. When the power planes are not used, it is recommended to use separate supply traces for the VA+ and VD+ pins from a low impedance supply point (the regulator output or the power entry point to the PC board). This will help ensure that the noisy digital supply does not corrupt the analog supply. PC BOARD LAYOUT AND GROUNDING CONSIDERATlONS To get the best possible performance from the ADC12048, the printed circuit boards should have separate analog and digital ground planes. The reason for using two ground planes is to prevent digital and analog ground currents from sharing the same path until they reach a very low impedance power supply point. This will prevent noisy digital switching currents from being injected into the analog ground. Figure 21 illustrates a favorable layout for ground planes, power supply and reference input bypass capacitors. It 29 www.national.com ADC12048 Analog Application Information ADC12048 Analog Application Information (Continued) 01238738 FIGURE 21. Top View of Printed Circuit Board for a 44-Pin PLCC ADC12048 The performance improves by having a 0.1 F capacitor between the VREF+ and VREF-, and by bypassing in a manner similar to that described for the supply pins. When a single ended reference is used, VREF- is connected to AGND and only two capacitors are used between VREF+ and VREF- (0.1 F + 10 F). It is recommended to directly connect the AGND side of these capacitors to the VREF- instead of connecting VREF- and the ground sides of the capacitors separately to the ground planes. This provides a significantly lower-impedance connection when using surface mount technology. When measuring AC input signals, any crosstalk between analog input/output lines and the reference lines (CH0-CH7, MUXOUT , ADC IN , VREF ) should be minimized. Crosstalk is minimized by reducing any stray capacitance between the lines. This can be done by increasing the clearance between traces, keeping the traces as short as possible, shielding traces from each other by placing them on different sides of the AGND plane, or running AGND traces between them. Figure 21 also shows the reference input bypass capacitors. Here the reference inputs are considered to be differential. www.national.com 30 ADC12048 Physical Dimensions inches (millimeters) unless otherwise noted 44-Lead Molded Plastic Leaded Chip Carrier Order Number ADC12048CIV NS Package Number V44A 44-Lead (10mm x 10mm) Molded Plastic Quad Flat Package Order Number ADC12048CIVF NS Package Number VGZ44A 31 www.national.com ADC12048 12-Bit Plus Sign 216 kHz 8-Channel Sampling Analog-to-Digital Converter Notes LIFE SUPPORT POLICY NATIONAL'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. National Semiconductor Corporation Americas Email: support@nsc.com www.national.com National Semiconductor Europe Fax: +49 (0) 180-530 85 86 Email: europe.support@nsc.com Deutsch Tel: +49 (0) 69 9508 6208 English Tel: +44 (0) 870 24 0 2171 Francais Tel: +33 (0) 1 41 91 8790 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. National Semiconductor Asia Pacific Customer Response Group Tel: 65-2544466 Fax: 65-2504466 Email: ap.support@nsc.com National Semiconductor Japan Ltd. Tel: 81-3-5639-7560 Fax: 81-3-5639-7507 National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications. IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Communications and Telecom www.ti.com/communications Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps DLP(R) Products www.dlp.com Energy and Lighting www.ti.com/energy DSP dsp.ti.com Industrial www.ti.com/industrial Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical Interface interface.ti.com Security www.ti.com/security Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive Microcontrollers microcontroller.ti.com Video and Imaging RFID www.ti-rfid.com OMAP Mobile Processors www.ti.com/omap Wireless Connectivity www.ti.com/wirelessconnectivity TI E2E Community Home Page www.ti.com/video e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright (c) 2011, Texas Instruments Incorporated