LCA120 Single-Pole, Normally Open OptoMOS(R) Relay INTEGRATED CIRCUITS DIVISION Parameter Blocking Voltage Load Current On-Resistance (max) Ratings 250 170 20 Units VP mArms & mADC Description The LCA120 is a single-pole, normally open (1-Form-A) solid state relay that uses optically coupled MOSFET technology to provide 3750Vrms of input to output isolation. Its optically coupled outputs, which use the patented OptoMOS architecture, are controlled by a highly efficient GaAIAs infrared LED. Features * 3750Vrms Input/Output Isolation * Low Drive Power Requirements (TTL/CMOS Compatible) * High Reliability * Arc-Free With No Snubbing Circuits * No EMI/RFI Generation * Small 6-Pin Package * Machine Insertable, Wave Solderable * Surface Mount Tape & Reel Version Available * V-0 Flammability Classification Rating LCA120 can be used to replace mechanical relays, and offers the superior reliability associated with semiconductor devices. Because it has no moving parts, it can offer faster, bounce-free switching in a more compact surface mount or thru-hole package. Approvals Applications * Telecommunications * Telecom Switching * Tip/Ring Circuits * Modem Switching (Laptop, Notebook, Pocket Size) * Hook Switch * Dial Pulsing * Ground Start * Ringing Injection * Instrumentation * Multiplexers * Data Acquisition * Electronic Switching * I/O Subsystems * Meters (Watt-Hour, Water, Gas) * Medical Equipment--Patient/Equipment Isolation * Security * Aerospace * Industrial Controls * UL Recognized Component: File E76270 * CSA Certified Component: Certificate 1175739 * EN/IEC 60950-1 Certified Component: TUV Certificate B 09 07 49410 004 Ordering Information Part # LCA120 LCA120S LCA120STR Description 6-Pin DIP (50/Tube) 6-Pin Surface Mount (50/Tube) 6-Pin Surface Mount (1,000/Reel) Pin Configuration AC/DC Configuration + Control - Control Do Not Use 1 6 2 5 3 4 Load Do Not Use Load DC Only Configuration + Control - Control Do Not Use 1 6 2 5 3 4 + Load - Load Switching Characteristics of Normally Open Devices Form-A IF 90% Pb DS-LCA120-R11 10% ILOAD e3 ton www.ixysic.com toff 1 INTEGRATED CIRCUITS DIVISION LCA120 Absolute Maximum Ratings @ 25C Parameter Blocking Voltage Reverse Input Voltage Input Control Current Peak (10ms) Input Power Dissipation 1 Total Power Dissipation 2 Isolation Voltage, Input to Output Operational Temperature Storage Temperature 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Ratings 250 5 50 1 150 800 3750 -40 to +85 -40 to +125 Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Units VP V mA A mW mW Vrms C C Electrical Characteristics @ 25C Parameter Output Characteristics Load Current AC/DC Configuration, Continuous 1 DC Configuration, Continuous 1 Peak On-Resistance 2 AC/DC Configuration DC Configuration Off-State Leakage Current Switching Speeds Turn-On Turn-Off Output Capacitance Input Characteristics Input Control Current to Activate Input Control Current to Deactivate Input Voltage Drop Reverse Input Current Common Characteristics Capacitance, Input to Output 1 2 Conditions Symbol Min Typ Max Units - - 170 200 350 mArms & mADC mADC mA 15 5 - 20 6 1 ILEAK - A VL=50V, f=1MHz ton toff COUT - 50 3 3 - ms ms pF IL = Load Current IF = 5mA VR = 5V IF IF VF IR 0.4 0.9 - 0.7 1.2 - 5 1.4 10 mA mA V A - CI/O - 3 - pF t=10ms IL ILPK IL=170mA IL=200mA VL=250VP RON IF = 5mA, VL = 10V If both poles operate, then the load current must be derated so that the package power dissipation value is not exceeded. Measurement taken within 1 second of on-time. 2 www.ixysic.com R11 INTEGRATED CIRCUITS DIVISION LCA120 PERFORMANCE DATA @25C (Unless Otherwise Noted)* 25 20 15 10 5 1.17 25 1.19 1.21 1.23 15 10 5 20 15 10 5 0 1.25 0.35 0.625 0.875 1.125 1.375 1.625 1.875 2.125 0.40 0.45 0.50 0.55 0.60 0.65 LED Forward Voltage Drop (V) Turn-On Time (ms) Turn-Off Time (ms) Typical IF for Switch Operation (N=50, IL=170mADC) Typical IF for Switch Dropout (N=50, IL=170mADC) Typical On-Resistance Distribution (N=50, IF=5mA, IL=170mADC) 25 20 Device Count (N) Device Count (N) 20 0 0 Typical Turn-Off Time (N=50, IF=5mA, IL=170mADC) 25 Device Count (N) Device Count (N) Device Count (N) 30 25 Typical Turn-On Time (N=50, IF=5mA, IL=170mADC) 15 10 5 35 30 20 Device Count (N) 35 Typical LED Forward Voltage Drop (N=50, IF=5mA) 15 10 5 0.40 0.50 0.60 0.70 0.80 0.90 20 15 10 5 0 0 25 0 0.3 1.0 0.4 0.5 0.6 0.7 0.8 0.9 11.6 11.8 12.0 12.2 12.4 On-Resistance (:) LED Current (mA) LED Current (mA) Typical Blocking Voltage Distribution (N=50) 35 Device Count (N) 30 25 20 15 10 5 0 305 315 325 335 345 355 365 Blocking Voltage (VP) Typical Turn-On Time vs.LED Forward Current (IL=170mADC) 1.4 1.8 0.40 1.4 IF=50mA IF=30mA IF=20mA IF=10mA IF=5mA 1.2 1.0 Turn-Off Time (ms) 1.6 1.0 0.8 0.6 0.4 -20 0 20 40 60 Temperature (C) 80 100 120 0.38 0.37 0.36 0.34 0 -40 0.39 0.35 0.2 0.8 Typical Turn-Off Time vs. LED Forward Current (IL=170mADC) 0.41 1.2 Turn-On Time (ms) LED Forward Voltage Drop (V) Typical LED Forward Voltage Drop vs. Temperature 0 5 10 15 20 25 30 35 40 LED Forward Current (mA) 45 50 0 5 10 15 20 25 30 35 40 45 50 LED Forward Current (mA) *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R11 www.ixysic.com 3 INTEGRATED CIRCUITS DIVISION LCA120 Typical Turn-On Time vs. Temperature (IL=170mADC) Typical Turn-Off Time vs. Temperature (IF=5mA, IL=170mADC) 0.7 IF=5mA IF=10mA IF=20mA 0.5 0.4 0.3 0.2 2.5 0 20 40 60 80 100 20 15 10 0 0 -20 25 5 0.1 -40 Typical On-Resistance vs. Temperature (IF=5mA, IL=170mADC) 30 0.6 On-Resistance (:) 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 Turn-Off Time (ms) Turn-On Time (ms) PERFORMANCE DATA @25C (Unless Otherwise Noted)* -40 -20 0 20 40 60 80 -40 100 -20 0 20 40 60 80 100 Temperature (C) Temperature (C) Temperature (C) Typical IF for Switch Operation vs. Temperature (IL=170mADC) Typical IF for Switch Dropout vs. Temperature (IL=170mADC) Typical Load Current vs. Load Voltage (IF=5mA) 2.5 200 1.5 1.0 0.5 2.0 Load Current (mA) LED Current (mA) LED Current (mA) 150 2.0 1.5 1.0 0.5 100 50 0 -50 -100 -150 0 0 -40 -20 0 20 40 60 80 100 -40 0 20 40 60 80 -200 -2.5 -2.0 -1.5 -1.0 -0.5 100 Load Voltage (V) Maximum Load Current vs. Temperature Typical Blocking Voltage vs. Temperature Typical Leakage vs. Temperature Measured across Pins 4&6 0.025 150 IF=20mA IF=10mA IF=5mA 100 50 0 345 0.020 340 Leakage (PA) Blocking Voltage (VP) 200 335 330 325 0 20 40 60 80 100 120 -40 -20 0 20 40 60 80 100 Temperature (C) Temperature (C) 0.015 0.010 0.005 320 315 -20 0.5 1.0 1.5 2.0 2.5 Temperature (C) 350 -40 0 Temperature (C) 250 Load Current (mA) -20 0 -40 -20 0 20 40 60 80 100 Temperature (C) Energy Rating Curve 1.2 Load Current (A) 1.0 0.8 0.6 0.4 0.2 0 10Ps 100Ps 1ms 10ms 100ms 1s 10s 100s Time *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.ixysic.com R11 INTEGRATED CIRCUITS DIVISION LCA120 Manufacturing Information Moisture Sensitivity All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled according to the limitations and information in that standard as well as to any limitations set forth in the information or standards referenced below. Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced product performance, reduction of operable life, and/or reduction of overall reliability. This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033. Device Moisture Sensitivity Level (MSL) Rating LCA120 / LCA120S MSL 1 ESD Sensitivity This product is ESD Sensitive, and should be handled according to the industry standard JESD-625. Reflow Profile This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020 must be observed. Device Maximum Temperature x Time LCA120 / LCA120S 250C for 30 seconds Board Wash IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy should not be used. Pb R11 e3 www.ixysic.com 5 INTEGRATED CIRCUITS DIVISION LCA120 MECHANICAL DIMENSIONS LCA120 8.382 0.381 (0.330 0.015) PCB Hole Pattern 7.239 TYP (0.285 TYP) 2.54 0.127 (0.100 0.005) 6 - 0.800 DIA. (6 - 0.031 DIA.) 9.144 0.508 (0.360 0.020) 6.350 0.127 (0.250 0.005) 2.540 0.127 (0.100 0.005) 7.620 0.127 (0.300 0.005) Pin 1 7.620 0.254 (0.300 0.010) 1.651 0.254 (0.065 0.010) 3.302 0.051 (0.130 0.002) 0.254 0.0127 (0.010 0.0005) 6.350 0.127 (0.250 0.005) 5.080 0.127 (0.200 0.005) 4.064 TYP (0.160 TYP) Dimensions mm (inches) 0.457 0.076 (0.018 0.003) LCA120S 8.382 0.381 (0.330 0.015) 9.524 0.508 (0.375 0.020) Pin 1 0.635 0.127 (0.025 0.005) PCB Land Pattern 2.54 0.127 (0.100 0.005) 2.54 (0.10) 6.350 0.127 (0.250 0.005) 0.457 0.076 (0.018 0.003) 1.651 0.254 (0.065 0.010) 7.620 0.254 (0.300 0.010) 0.254 0.0127 (0.010 0.0005) 8.90 (0.3503) 1.65 (0.0649) 0.65 (0.0255) 3.302 0.051 (0.130 0.002) 4.445 0.254 (0.175 0.010) Dimensions mm (inches) 1.651 0.254 (0.065 0.010) 6 www.ixysic.com R11 INTEGRATED CIRCUITS DIVISION LCA120 LCA120STR Tape & Reel 330.2 Dia (13.00 Dia) Top Cover Tape Thickness 0.102 Max (0.004 Max) W=16.00 (0.63) B0 = 10.10 (0.398) K0 = 4.90 (0.19) K1 = 3.80 (0.15) P = 12.00 (0.472) User Direction of Feed Embossed Carrier Embossment A0 = 10.10 (0.398) Dimensions mm (inches) NOTES: 1. All dimensions carry tolerances of EIA Standard 481-2 2. The tape complies with all "Notes" for constant dimensions listed on page 5 of EIA-481-2 For additional information please visit our website at: www.ixysic.com IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated Circuits Division's Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division's product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice. 7 Specification: DS-LCA120-R11 (c)Copyright 2012, IXYS Integrated Circuits Division OptoMOS(R) is a registered trademark of IXYS Integrated Circuits Division All rights reserved. Printed in USA. 12/22/2012 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: IXYS: LCA120 LCA120S LCA120STR