Current Transducer HXS 10-NP/SP3
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
All Data are given with a RL = 10 kΩ
Electrical data
Primary nominal Primary current Type
r.m.s. current measuring range
IPN (A) IP (A)
Serial Parallel Serial Parallel
±10 ±20 ±30 ±60 HXS 10-NP/SP3
VOUT Analog output voltage @ IPVREF ± (0.625·IP/IPN)V
IP = 0 VREF ± 0.0125 V
VREF Internal Reference 1) - Output voltage 2.5 ± 0.025 V
VREF Output impedance typ. 200 Ω
VREF Load impedance ≥ 200 kΩ
R L Output load resistance ≥ 2 kΩ
ROUT Output impedance < 10 Ω
C L Max. output capacitive load < 1µF
VCSupply voltage (± 5 %) 5V
ICCurrent consumption @ VC = 5 V 22 mA
Accuracy - Dynamic performance data
XAccuracy 2) @ IPN , TA = 25°C ≤±1 % of IPN
εLLinearity 0.. IPN ≤±0.5 % of IPN
.. 3 x IPN ≤±1 % of IPN
TCVOUT Thermal drift of VOUT @ IP = 0 ≤±0.4 mV/K
TCVREF Thermal drift of VREF ≤±0.01 %/K
TCVOUT / VREF Thermal drift of VOUT / VREF @ IP = 0 ≤±0.2 mV/K
TCεGThermal drift of the gain ≤±0.05% of reading/K
VOM Residual voltage @ IP = 0, after an overload of 3 x IPN DC <±0.7 % of IPN
tra Reaction time @ 10 % of IPN < 3 µs
trResponse time @ 90 % of IPN < 5 µs
di/dt di/dt accurately followed > 50 A/µs
Output noise (DC ..10 kHz) < 15 mVpp
(DC .. 1 MHz) < 40 mVpp
fFrequency bandwidth (-3 dB) 3) DC .. 50 kHz
General data
TAAmbient operating temperature - 40 .. + 85 °C
TSAmbient storage temperature - 40 .. + 85 °C
dCp Creepage distance > 5.5 mm
dCl Clearance distance > 5.5 mm
CTI Comparative tracking index (Group I ) > 600 V
UL94 classification V0
mMass 10 g
Standards EN 50178 (97-10-01)
Features
•Hall effect measuring principle
•Multirange current transducer
through PCB pattern lay-out
•Galvanic isolation between primary
and secondary circuit
•Isolation test voltage 2500V
•Low power consumption
•Extremely low profile, 10mm
•Single power supply +5V
•Fixed offset & gain
Special Feature
•Two separate primary windings for
dual phase measurement
Advantages
•Small size and space saving
•Only one design for wide current
ratings range
•High immunity to external
interference.
•Internal & external reference
Applications
•AC variable speed drives
•Static converters for DC motor drives
•Battery supplied applications
•Uninterruptible Power Supplies
(UPS)
•Switched Mode Power Supplies
(SMPS)
•Power supplies for welding
applications.
IPN = 10 A
DUAL PHASE
041222/2
LEM Components www.lem.com