26
A Softline Matt
B Splashproof (with Arcshield)
V Curved
W Splashproof (with Arcshield)
P Lit window Matt
X Two colour Matt
F Flat lens Gloss (0480 only)
A Softline lens Matt (0480 only)
as F but with raised profile
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR,VOLTAGE ETC
C1553 A L
---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
1550 Series 16(4)A 250Vac T125
UL CSA 16A 250Vac, (2 posn) 250Vac 1hp,125Vac 1/2hp,
(3 posn) 250 Vac 1/2hp,125Vac 1/4hp. UL 85˚C, file E45221, CSA file LR10990
Inrush 36A to EN61058-1 & 20A 28Vdc
1350 series 16(4)A 250Vac T85 1E4 (10,000 Ops.)
On request 16(6)A 250Vac T125 5E4 (50,000 Ops.) & 150A Inrush to IEC 65
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp
UL 72Vdc 7A, 36Vdc 14A. UL 85˚C, file E45221, CSA file LR10990
20A 28Vdc
3mm contact gap except if marked
µ.
Technical data on pages 4 & 5 (switches),66 (indicators)
ON - OFF
1550 Standard & 1350 Hi Inrush Switches 150A to IEC65 and 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
On Off Switches - ON when pressed over terminal 1
TERMINAL
Hi Inrush
1350
C
6.3 x 0.8
H
4.8 x 0.8*
K
2.8 x 0.8*
T
Solder
U
Right angle T Solder (Not DP)
X
PCB 0.8Sq*
*
Contact factory for details on 1350 series
9.1
7.0
Ø2.1
9.1
9.1
2.0 1.2
3.2
Ø2.1
9.1
4.0
12 3
45 6
In house test
In house test
Standard
1550
ON - OFF
(momentary ON)
1551
HP rating N/A
ON - OFF
(momentary OFF)
1552
HP rating N/A
ON - OFF
Lit
1353
Not W,X or B rocker
1553
Not W,X or B rocker
ON - ON
1560 µ
ON - ON
(momentary 1 side)
1561 µ
HP rating N/A
2 Circuit
ON - ON
1562 µ
In house tests only
ON - OFF - ON
1570 µ
125V & 250V 1/2 HP
H terminal rated T100 only
ON - OFF - ON
(momentary 1 side)
1571 µ
HP rating N/A
H terminal rated T100 only
ON - OFF - ON
(momentary 2 sides)
1572 µ
HP rating N/A
H terminal rated T100 only
3 position selective
OFF - A - A+B
1484 µ
In-house tested to 10(3)A 250Vac
3 position selective
A - B - C
(link not supplied)
1487 µ
In-house tested to 10(3)A 250Vac
Indicator
Technical data on page 66
0480
X terminal N/A
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
“Arcshield” feature hides visible switching arc
Lit (not momentary)
Lit (not momentary)
Lit (not momentary)
Matt or gloss Gloss only
Top view
(On Off only - not momentary)
27
Examples of printing
EN602A EN730 EN822
C1350AL ---
C0480AL ---
C1550XL --- C1553PL ---
Finish Matt is standard
Colour Call factory for custom colours.
A full range is available for large orders
Legend printing Select from the examples or
call factory for custom legends
Lamp voltage Call factory for details
Blanking plates A0494 Dummy units
to fill unused panel holes
Protective cover (designed to IP65)
Snaps on to A, L, Q or T bodies
(add G after body in cat no).This reduces
panel thickness by 1mm.
Panel sealing washer W42 is available for
the above body sizes but reduces panel
thickness by a further 0.8mm.
Covers are not suitable for momentary types.
Arcshield
Hides switching arc
For all options call the factory
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
A
Gloss or Matt
B
Matt only
L
Matt only
Q
Gloss or matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
Panel cut-out *Flange
OPTIONS
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R0.75 to 3.0mm
*For cut-out details
on momentary switches
call the factory
Terminal spacing - Poles 10.2 between centres
22.3/22.4
27.2
27.3
22.1/22.2
30.0
30.1
22.3/22.4
28.2
28.3
22.3/22.4
28.2
28.3
23.0/25.4
28.4
28.5
22.1/22.2
30.0
30.1
25.0
30.2
25.0
33.4
R3.5
32.0
25.0
R1.0
25.0
30.2
R1.6
28.9
33.2
30.2
25.0
R1.6
C1553AA with M616 guard
Cut-out 22.0/22.1x29.4/29.5
Guard accepts “A body onl y
Optional snap-in M441 barrier
Cut-outs must be punched in the direction of insertion
plunger tube
1350 High inrush, positive break switching
The 1350 series mechanism ensures
contact welds formed at switch-on,
are positively separated by the
plunger tube acting directly on the
step in the moving contact.
step