SPECIFICATION SUMMARY
Capacitance Range
0.001µF to 1.0µF Capacitance is measured at 25°C and at or
referred to a frequency of 1KHz.
Capacitance Tolerance
K=?0%, J=?0%, G=?0%, F=?0%
Operating Temperature Range
From -55ºC to 125ºC
Enclosure/ Construction
Hermetically sealed ceramic case with tinned metal end caps.
Voltage Rating
DC working voltage ratings at +85ºC, 50VDC, 100VDC,
150VDC, 200VDC and 300VDC. Voltage derating of 1.25% per
degree C is necessary to +125°C.
Quality Control
Capacitors are tested 100% for:
?Capacitance tolerance
?Dissipation Factor
?Dielectric withstanding voltage
?Insulation Resistance
?Seal per Method 112 of MIL-STD-202
HECR-test condition A
M39022/11 - also tested to condition C, procedure llla.
Complete process and inspection data is maintained on file and
is available on special request.
Environmental
Parameter Condition Method
Vibration
Immersion
Shock
Humidity
Thermal Shock
Reference MIL-STD-202
CHARACTERISTICS
Insulation Resistance
Temparature(°C) 25°C 85°C 125°C
Megaohms x
Microfarads
100,000 7,000 700
Insulation Resistance
Dielectric Strength
Capacitors will withstand a DC potential of 200% rated
voltage for two (2) minutes without damage or
breakdown.
Test voltage is applied and discharged through a
resistance of 1 OHM per volt minimum, and at 25°C.
Capacitance Change
Temparature(°C) -55°C +25°C +85°C +125°C
Percentage Change
(typical)
-2.5 0 ?.0 ?.0
Capacitance Change
Dissipation Factor
When measured at 1KHz, the dissipation factor will not exceed
0.2% form +25?to 125°C