CSM_E52_DS_E_20_1
1
Temperature Sensor
E52
A Wide Variety of High-precision
Temperature Sensors
Previous models with M3 screw connections have been joined
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.
Ordering Information
List of Models (Temperature Sensors)
Note: 1. Exclusive models are provided on the following page.
2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use.
3. The temperature range varies with the material, thickness, construction, and element type of the protective tubing.
Classifi-
cation
Descrip-
tion
Model and appearance Tempera-
ture range
(See note 3.)
Element
type
Conduc-
tor type
Class Protective
tubing
material
Terminal
type
Page
General-
purpose
Models
Sheathed
platinum
resistance
thermom-
eter
E52-P@AY 196°C to
450°C
Pt100 3-conduc-
tor system
B SUS316 Exposed
lead wires
5
E52-P@C-N 196°C to
450°C
ASTM316L Enclosed
terminals
6
E52-P@B-N Exposed
terminals
Standard
platinum
resistance
thermom-
eter
E52-P@C-N 0°C to 450°C SUS316 Enclosed
terminals
7
Sheathed
thermo-
couple
E52-CA@AY
E52-IC@AY
0°C to 900°CK (CA)
J (IC)
Non-
grounded
type
2 (0.75) ASTM316L Exposed
lead wires
9 to
12
E52-CA@B-N
E52-IC@B-N
Exposed
terminals
13
E52-CA@C-N
E52-IC@C-N
Enclosed
terminals
Standard
thermo-
couple
E52-CA@B-N
E52-IC@B-N
SUS316 Exposed
terminals
14
E52-CA@C-N
E52-IC@C-N
Enclosed
terminals
15
E52-PR@C-N 0°C to
1,400°C
R (PR) 2 (0.25) JIS ceramic
JIS special
ceramic
Enclosed
terminals
16
Low-cost
Models
Low-cost
platinum
resistance
thermom-
eter
E52-P10AEY 0°C to 250°C Pt100 3-conduc-
tor system
B SUS316 Exposed
lead wires
17
E52-P6DY 50°C to
250°C
SUS304
E52-P6FY
Low-cost
thermo-
couple
E52-CA@ASY
E52-IC@ASY
0°C to 400°CK (CA)
J (IC)
Non-
grounded
type
2 (0.75) 18
E52-CA1DY
E52-IC1DY
Grounded
type
19
E52-CA6F-N
E52-IC6F-N
E52-CA6D-N
E52-IC6D-N
20
E52-CA10AE-N
E52-IC10AE-N
Non-
grounded
type
Refer to Safety Precautions for All Temperature
Controllers.
E52
2
Note: 1. General-purpose models and low-cost models are provided on the previous page.
2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use.
3. The temperature range varies with the material, thickness, construction, and element type of the protective tubing.
Use the temperature sensors with ferrule from the list on the next page.
Classifi-
cation
Descrip-
tion
Model and appearance Tempera-
ture range
(See note 3.)
Element
type
Conduc-
tor type
Class Protective
tubing
material
Terminal
type
Page
Exclusive
Models
Bayonet
spring for
molding
machines
E52-CA2GVY
E52-IC2GVY
0°C to 350°CK (CA)
J (IC)
Grounded
type
2 (0.75) SUS304 Exposed
lead wires
21
Crimping
terminals
E52-CA1GTY
E52-IC1GTY
0°C to 300°C---
Used for
measur-
ing sur-
face
tempera-
tures
E52-P2GSY 50°C to
250°C
Pt100 3-conduc-
tor system
BSUS304
Used for
room tem-
perature
measure-
ment
E52-P10GRY 50°C to
60°C
22
Double-el-
ement
model
E52-CA20AY-7 0°C to 900°C K (CA) Two non-
grounded
types
2 (0.75) ASTM316L 27
E52-P20AY-7 196°C to
250°C
Pt100 Two 3-
conductor
systems
B
E52-P20C-N-7 200°C to
450°C
Enclosed
terminals
28
Water-
proof mod-
el
E52-P10GPY 0°C to 70°C 3-conduc-
tor system
SUS304 Exposed
lead wires
22
E52-P5AY-40 50°C to
180°C
Fluororesin
tubing
24
Corrosion-
resistant
model
E52-P20AY-1 80°C to
180°C
E52-CA20AY-1 0°C to 180°CK (CA) Non-
grounded
type
2 (0.75)
Silicone-
covered
lead wires
E52-CA1DY-40 0°C to 300°C Grounded
type
SUS304 29
E52-CA1GTY-14
0°C to 200°C---
Explosion-
proof mod-
el
E52-P
@@
C-N-6
--- Pt100 3-conduc-
tor system
B ASTM316L Enclosed
terminals
25
E52-CA
@@
C-N-6
--- K (CA) Non-
grounded
type
2 (0.75)
Thermistors E52-THE5A
E52-THE6F
E52-THE6D
50°C to
300°C
Ther-
mistor
Element-
inter-
change-
able
thermistor
1 SUS304 Exposed
lead wires
31
3
E52
List of Models (Temperature Sensors with ferrule)
Note: 1. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use.
2. The temperature range varies with the material, thickness, construction, and element type of the protective tubing.
Accessories
It is recommended that the following accessories be used for mounting Temperature Sensors.
Classifi-
cation
Descrip-
tion
Model and appearance Tempera-
ture range
(See note 3.)
Element
type
Conduc-
tor type
Class Protective
tubing
material
Terminal
type
Page
General-
purpose
Models
Sheathed
platinum re-
sistance
thermometer
E52-P@AF 196°C to
450°C
Pt100 3-conduc-
tor system
B SUS316 Exposed
lead wires
33
Sheathed
thermocou
ple
E52-CA@AF 0°C to 900°CK (CA) Non-
grounded
type
2 (0.75) ASTM316L 35 to
33
Low-cost
Models
Low-cost
platinum
resistance
thermometer
E52-P10AEF 0°C to 250°C Pt100 3-conduc-
tor system
BSUS316 37
E52-P6DF 50°C to
250°C
SUS304
E52-P6FF
Low-cost
thermo-
couple
E52-CA1DF 0°C to 400°C K (CA) Grounded
type
2 (0.75) 38
Exclusive
Models
Bayonet
spring for
molding
machines
E52-CA2GVF 0°C to 350°C K (CA) Grounded
type
2 (0.75) SUS304 39
Crimping
terminals
E52-CA1GTF 0°C to 300°C---
Used for
measuring
surface tem-
peratures
E52-P2GSF 50°C to
250°C
Pt100 3-conduc-
tor system
BSUS304
Used for
room temper-
ature mea-
surement
E52-P10GRF 50°C to
60°C
40
Waterproof
model
E52-P10GPF 0°C to 70°C
E52-P5AF-40 50°C to
180°C
Fluororesin
tubing
41
Silicone-
covered
lead wires
E52-CA1DF-40
0°C to 300°C K (CA) Grounded
type
2 (0.75) SUS304 42
E52-CA1GTF-14
0°C to 200°C---
Accessory Temperature
range
Mounting example Page
Compression
Fitting
600°C max. Mounting with
Compression
Fitting
Note: The Compression Fitting is not of
airtight construction. Do not use
the Compression Fitting for
applications in which the exposure
of the sensing object will cause
problems.
43
Loose Flange 400°C max. Mounting with
Loose Flange Note: 1. Use the Loose Flange in
normal atmospheric pressure.
The Loose Flange is not of
airtight construction.
2. Use the Loose Flange at 400°C
max.
3. Do not apply the Loose Flange
to protective tubing diameters
other than the applicable ones.
Compression Fitting
PT screw
Welding
Terminal box
Protective tubing
Loose Flange
Mounting screw
Terminal box
Protective tubing
E52
4
General-purpose Models
Model Number Legend
The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.
Platinum Resistance Thermometers
1. Element type
P: Pt100
2. Protective tubing length (L)
Specify the length in centimeters within the following range:
Unit (cm)
E52-@@AY
E52-@@B-N
E52-@@C-N
3. Terminal
AY: Exposed lead wires (Y-type crimp terminal for M3.5)
B-N: Exposed terminals
C-N: Enclosed terminals
4. Diameter
3.2: 3.2-mm dia. (Protective tubing construction: Sheathed)
E52-@@AY and E52-@@C-N only
4.8: 4.8-mm dia. (Protective tubing construction: Sheathed)
E52-@@AY and E52-@@C-N only
6.4: 6.4-mm dia. (Protective tubing construction: Sheathed)
E52-@@AY and E52-@@C-N only
8: 8-mm dia. (Protective tubing construction: Sheathed)
E52-@@B-N and E52-@@C-N only
10: 10-mm dia. (Protective tubing construction: Standard)
E52-@@C-N only
5. Heat resistance
Specify for E52-@@AY model only.
6. Lead length (M)
Specify the length in meters within the following range for the E52-
@@AY only:
Range: 0.5, 1 to 100 m
Examples
Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-P42AY D=4.8 NETU 10M
Sheathed Platinum Resistance Thermometers
Refer to Model Number Legend above for the Pt100.
Specifications
E52-@@@ D=@@@M
123 4 56
Diameter (D) Length (L)
3.2 7 to 100
4.8 10 to 600
6.4 13 to 1,300
Diameter (D) Length (L)
8 20 to 100
Diameter (D) Length (L)
3.2 12 to 100
4.8 15 to 600
6.4 18 to 1,300
8 21 to 100
10 26 to 100
Code Temperature range Lead type
--- 20°C to 70°C
Sleeve: 0°C to 70°C
Vinyl-covered
NETU 0°C to 180°C
Sleeve: 0°C to 100°C
Glass-wool-covered,
externally shielded with
stainless
Element type Pt100
Class JIS class B
Sheath material SUS316 (E52-P@AY)
ASTM316L (E52-P@B-N, E52-P@C-N)
Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia., 8 dia
Conductor type 3-conductor system
Temperature range 196°C to 450°C (in dry air)
5
E52
Exposed-lead Models
E52-P@AY
Dimensions
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Terminal type Protective
tubing
diameter D
(mm)
Protective
tubing length
L (cm)
Lead wire
type
Lead wire length M (m)
1248
Model
Exposed-lead
Models
3.2 dia. 15 Standard E52-P15AY D=3.2
1M
E52-P15AY D=3.2
2M
E52-P15AY D=3.2
4M
E52-P15AY D=3.2
8M
Heat resistive E52-P15AY D=3.2
NETU 1M
E52-P15AY D=3.2
NETU 2M
E52-P15AY D=3.2
NETU 4M
E52-P15AY D=3.2
NETU 8M
20 Standard E52-P20AY D=3.2
1M
E52-P20AY D=3.2
2M
E52-P20AY D=3.2
4M
E52-P20AY D=3.2
8M
Heat resistive E52-P20AY D=3.2
NETU 1M
E52-P20AY D=3.2
NETU 2M
E52-P20AY D=3.2
NETU 4M
E52-P20AY D=3.2
NETU 8M
35 Standard E52-P35AY D=3.2
1M
E52-P35AY D=3.2
2M
E52-P35AY D=3.2
4M
E52-P35AY D=3.2
8M
Heat resistive E52-P35AY D=3.2
NETU 1M
E52-P35AY D=3.2
NETU 2M
E52-P35AY D=3.2
NETU 4M
E52-P35AY D=3.2
NETU 8M
4.8 dia. 20 Standard E52-P20AY D=4.8
1M
E52-P20AY D=4.8
2M
E52-P20AY D=4.8
4M
E52-P20AY D=4.8
8M
Heat resistive E52-P20AY D=4.8
NETU 1M
E52-P20AY D=4.8
NETU 2M
E52-P20AY D=4.8
NETU 4M
E52-P20AY D=4.8
NETU 8M
35 Standard E52-P35AY D=4.8
1M
E52-P35AY D=4.8
2M
E52-P35AY D=4.8
4M
E52-P35AY D=4.8
8M
Heat resistive E52-P35AY D=4.8
NETU 1M
E52-P35AY D=4.8
NETU 2M
E52-P35AY D=4.8
NETU 4M
E52-P35AY D=4.8
NETU 8M
50 Standard E52-P50AY D=4.8
1M
E52-P50AY D=4.8
2M
E52-P50AY D=4.8
4M
E52-P50AY D=4.8
8M
Heat resistive E52-P50AY D=4.8
NETU 1M
E52-P50AY D=4.8
NETU 2M
E52-P50AY D=4.8
NETU 4M
E52-P50AY D=4.8
NETU 8M
6.4 dia. 20 Standard E52-P20AY D=6.4
1M
E52-P20AY D=6.4
2M
E52-P20AY D=6.4
4M
E52-P20AY D=6.4
8M
Heat resistive E52-P20AY D=6.4
NETU 1M
E52-P20AY D=6.4
NETU 2M
E52-P20AY D=6.4
NETU 4M
E52-P20AY D=6.4
NETU 8M
35 Standard E52-P35AY D=6.4
1M
E52-P35AY D=6.4
2M
E52-P35AY D=6.4
4M
E52-P35AY D=6.4
8M
Heat resistive E52-P35AY D=6.4
NETU 1M
E52-P35AY D=6.4
NETU 2M
E52-P35AY D=6.4
NETU 4M
E52-P35AY D=6.4
NETU 8M
50 Standard E52-P50AY D=6.4
1M
E52-P50AY D=6.4
2M
E52-P50AY D=6.4
4M
E52-P50AY D=6.4
8M
Heat resistive E52-P50AY D=6.4
NETU 1M
E52-P50AY D=6.4
NETU 2M
E52-P50AY D=6.4
NETU 4M
E52-P50AY D=6.4
NETU 8M
40
(30) (80)
D±0.05 8 dia.
M±4% 85±10L±3%
Sleeve (SUS304)
Swage
Marking tube
(Red)
Shrinkable tube
(Black)
Sheath (SUS316)
Lead wire Product Label
Marking tube
(White)
White
Crimping terminal
Y type for M3.5
Red
Red (A)
White (B)
Black (B)
Unit (mm)
Ddl
3.2 dia. 8 40
4.8 dia. 8 40
6.4 dia. 8 40
Lead Wire
Standard (20°C to 70°C):
Fully vinyl-covered with twelve 0.18-dia
conductors (0.3 mm thick) and 4.8 mm
in outer dia. The sleeve resists a
temperature range between 0°C and
70°C.
Heat Resistive (0°C to 180°C):
Fully glass-wool-covered with thirty
0.12-dia. conductors (0.3 mm thick)
externally shielded with stainless steel,
4 mm in outer dia. The sleeve resists a
temperature range between 0°C and
100°C.
Lead Wire Length (M): 1, 2, 4, or 8 m
E52
6
Enclosed-terminal Models
E52-P@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Terminal box: The permissible temperature is 0°C to 90°C.
Note: 1. The terminals in the cap indicate polarity (A, B, b).
2. The length L is in centimeters, but “35” is 35 millimeters.
Therefore, for the E52-P35C-N: L = 35 (cm), the sheath length L 35 = 350 35 = 315 mm.
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Exposed-terminal Models
E52-P@B-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Note: The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-P35B-N: L = 35 (cm), the sheath length L 40 = 350 40 = 310 mm.
Terminal type Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
3.2 dia. 4.8 dia. 6.4 dia. 8 dia.
Model
Enclosed-terminal
Models
20 E52-P20C-N D=3.2 E52-P20C-N D=4.8 E52-P20C-N D=6.4 E52-P20C-N D=8
35 E52-P35C-N D=3.2 E52-P35C-N D=4.8 E52-P35C-N D=6.4 E52-P35C-N D=8
50 E52-P50C-N D=3.2 E52-P50C-N D=4.8 E52-P50C-N D=6.4 E52-P50C-N D=8
75 --- E52-P75C-N D=4.8 E52-P75C-N D=6.4 ---
40
(15)
(66)
(66)
58 dia.
L-35±3%
D±0.05
Product label
Socket (SUS304)
Chain
Terminal box
(Packing internal diameter : 6.5 dia)
Sheath (ASTM316L)
Cap
Swage
38
GUse wiring terminals that fit M3 screws.
5.6
19.2
45
30.5
42.5
17
17.6
(51)
(15)
21.5
b
B
A
3×M3
L-40±3%
19 dia.
Product label
Socket (SUS304)
Swage Sheath (ASTM316L)
Terminal box
8±0.05 dia.
Model Information
Custom-made models are available on request. Refer to page 4 for
details
Terminal
type
Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
8 dia.
Model
Exposed-
terminal
Models
20 E52-P20B-N D=8
35 E52-P35B-N D=8
50 E52-P50B-N D=8
Terminal box: The permissible temperature is 0°C to 100°C.
7
E52
Standard Platinum Resistance Thermometers
Refer to Model Number Legend on page 4 for the Pt100.
Specifications
Note: 1. Use the sheathed platinum resistance thermometer if condensation is likely to result.
Enclosed-terminal Models
E52-P@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Note: 1. The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-P75C-N: L = 75 (cm), the protective tubing length L 50 = 750 50 = 700 mm.
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (A, B, B).
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Element type Pt100
Class JIS class B
Protective tubing material SUS316
Conductor type 3-conductor system
Temperature range 0°C to 450°C (in dry air)
Terminal type Protective tubing
length L (cm)
Protective tubing
diameter D (mm)
10 dia.
Model
Enclosed-terminal
Models
35 E52-P35C-N D=10
50 E52-P50C-N D=10
75 E52-P75C-N D=10
100 E52-P100C-N D=10
53
(5)
(86)
(92)
82 dia.
38 dia.
L-50±3%
Chain
Cap
Terminal
box
Socket (SUS304)
Protective tubing (SUS316)
(Packing internal
diameter : 9 dia.)
Full-circled Welding
Product label
10±0.3 dia.
12
G
E52
8
Model Number Legend
The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.
Thermocouples
1. Element type
CA:K
IC: J
PR:R
2. Protective tubing length (L)
Specify the length in centimeters in the following range: Unit (cm)
E52-@@AY (Exposed-lead Model)
E52-@@B-N and E52-@@C-N (except E52-PR@C-N)
E52-PR@C-N
3. Terminal
AY: Exposed lead wires (Y-type crimp terminal for M3.5)
(element type: K, J)
B-N: Exposed terminals (element type: K, J)
C-N: Enclosed terminals (element type: K, J, R)
4. Diameter
Specify the protective tubing material according to the table.
5. Heat resistance
Specify this item for the exposed-lead models only.
6. Lead length (M)
Specify the length in meters in the following range for the E52-
@@AY only.
Range: 1 to 100 m
7. Protective tubing material
Examples
Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-CA42AY D=4.8 NETU 10M
Element: J; protective tubing length: 360 mm, enclosed terminals, protective tubing dia.: 3.2
E52-IC36C-N D=3.2
Diameter (D) Length (L)
1 2 to 200
1.6 3 to 500
3.2 5 to 2,000
4.8 8 to 2,300
6.4 10 to 1,200
8 12 to 1,000
Diameter (D) Length (L)
3.2 11 to 2,000
4.8 14 to 2,300
6.4 16 to 1,200
8.0 18 to 1,000
10 21 to 126
12 24 to 126
15 29 to 156
22 39 to 206
Diameter (D) Length (L)
15 50, 75, 100
Code Diameter
(D)
Protective tubing
construction
Protective tubing
material
1 1 mm Sheathed ASTM316L
1.6 1.6 mm Sheathed ASTM316L
3.2 3.2 mm Sheathed ASTM316L
4.8 4.8 mm Sheathed ASTM316L
6.4 6.4 mm Sheathed ASTM316L
8 8 mm Sheathed ASTM316L
10 10 mm Standard SUS316, SUS310S
12 12 mm Standard SUS316, SUS310S
15 15 mm Standard SUS316, SUS310S
PT1, PT0 (E52-PR)
22 22 mm Standard SUS316, SUS310S
Code Temperature range Lead type
--- 20°C to 70°C
Sleeve: 0°C to 70°C
Vinyl-covered
NETU 0°C to 150°C
Sleeve: 0°C to 100°C
Glass-wool-covered with exter-
nal shield of stainless
Code Protective tubing
material
Element type
--- ASTM316L K, J
SUS310S SUS310S K, D = 10 to 22
PT1 JIS ceramic Cat.1 R
PT0 JIS special ceramic R
9
E52
Sheathed Thermocouples
Specifications Permissible Temperature in Dry Air
Note: For details on the permissible temperature, refer to page D-5 of
Introduction of Temperature Controllers (Cat. No. H900).
Exposed-lead Models
E52-CA@AY
Dimensions
K (CA) Model Information (E52-CA@AY)
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Element type K (CA), J(IC)
Class JIS class 2 (0.75)
Thermal contact Non-grounded type
Sheath material CA: ASTM316L
IC: ASTM316L
D Element wire
K (CA)
ASTM316L
J (IC)
ASTM316L
1 dia. 650°C450°C
1.6 dia. 650°C450°C
3.2 dia. 750°C650°C
4.8 dia. 800°C750°C
6.4 dia. 800°C750°C
8.0 dia. 900°C750°C
Terminal type Protective
tubing diameter
D (mm)
Protective
tubing length L
(cm)
Lead wire type Lead wire length M (m)
1248
Model
Exposed-lead
Models
1 dia. 15 Standard E52-CA15AY D=1
1M
E52-CA15AY D=1
2M
E52-CA15AY D=1
4M
E52-CA15AY D=1
8M
Heat resistive E52-CA15AY D=1
NETU 1M
E52-CA15AY D=1
NETU 2M
E52-CA15AY D=1
NETU 4M
E52-CA15AY D=1
NETU 8M
20 Standard E52-CA20AY D=1
1M
E52-CA20AY D=1
2M
E52-CA20AY D=1
4M
E52-CA20AY D=1
8M
Heat resistive E52-CA20AY D=1
NETU 1M
E52-CA20AY D=1
NETU 2M
E52-CA20AY D=1
NETU 4M
E52-CA20AY D=1
NETU 8M
35 Standard E52-CA35AY D=1
1M
E52-CA35AY D=1
2M
E52-CA35AY D=1
4M
E52-CA35AY D=1
8M
Heat resistive E52-CA35AY D=1
NETU 1M
E52-CA35AY D=1
NETU 2M
E52-CA35AY D=1
NETU 4M
E52-CA35AY D=1
NETU 8M
L±3% 55
(80)
d
30±5
M±4% 90±10
D±0.05
Crimping terminal
Y type for M3.5
Product label
Sleeve (SUS304)
Sheath (ASTM316L)
Shrinkable tube
(CA:Blue, IC:Yellow)
Lead
wire
Swage
Marking tube (White)
Transparent
Red (+)
White ()
Unit (mm)
Ddl
1 dia. 8 55
1.6 dia. 8 55
3.2 dia. 8 55
4.8 dia. 8 55
6.4 dia. 11 55
8 dia. 11 55
Permissible Temperature in Dry Air
D Element wire
K (CA)
ASTM316L
1 dia. 650°C
1.6 dia. 650°C
3.2 dia. 750°C
4.8 dia. 800°C
6.4 dia. 800°C
8.0 dia. 900°C
Note: 1. Lead Wire (Compensating Conductor)
Standard (20°C to 70°C):
Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm
thick) and external dimensions of 2.4 × 4.1.
Heat Resistive (0°C to 150°C):
Fully glass-wool-covered with seven 0.3-dia. conductors
(0.5 mm thick) with external shield of stainless steel and
external dimensions of 2.8 × 4.6
The heat-resistive lead wires cannot be used in locations
exposed to water or other liquids.
Lead Wire Length (M): 1, 2, 4, or 8 m
2. The sleeve resists temperatures ranging between 20°C and
70°C for standard models and 0°C and 100°C for heat-resistive
models.
E52
10
Exposed-lead
Models
1.6 dia. 15 Standard E52-CA15AY D=1.6
1M
E52-CA15AY D=1.6
2M
E52-CA15AY D=1.6
4M
E52-CA15AY D=1.6
8M
Heat resistive E52-CA15AY D=1.6
NETU 1M
E52-CA15AY D=1.6
NETU 2M
E52-CA15AY D=1.6
NETU 4M
E52-CA15AY D=1.6
NETU 8M
20 Standard E52-CA20AY D=1.6
1M
E52-CA20AY D=1.6
2M
E52-CA20AY D=1.6
4M
E52-CA20AY D=1.6
8M
Heat resistive E52-CA20AY D=1.6
NETU 1M
E52-CA20AY D=1.6
NETU 2M
E52-CA20AY D=1.6
NETU 4M
E52-CA20AY D=1.6
NETU 8M
35 Standard E52-CA35AY D=1.6
1M
E52-CA35AY D=1.6
2M
E52-CA35AY D=1.6
4M
E52-CA35AY D=1.6
8M
Heat resistive E52-CA35AY D=1.6
NETU 1M
E52-CA35AY D=1.6
NETU 2M
E52-CA35AY D=1.6
NETU 4M
E52-CA35AY D=1.6
NETU 8M
3.2 dia. 15 Standard E52-CA15AY D=3.2
1M
E52-CA15AY D=3.2
2M
E52-CA15AY D=3.2
4M
E52-CA15AY D=3.2
8M
Heat resistive E52-CA15AY D=3.2
NETU 1M
E52-CA15AY D=3.2
NETU 2M
E52-CA15AY D=3.2
NETU 4M
E52-CA15AY D=3.2
NETU 8M
20 Standard E52-CA20AY D=3.2
1M
E52-CA20AY D=3.2
2M
E52-CA20AY D=3.2
4M
E52-CA20AY D=3.2
8M
Heat resistive E52-CA20AY D=3.2
NETU 1M
E52-CA20AY D=3.2
NETU 2M
E52-CA20AY D=3.2
NETU 4M
E52-CA20AY D=3.2
NETU 8M
35 Standard E52-CA35AY D=3.2
1M
E52-CA35AY D=3.2
2M
E52-CA35AY D=3.2
4M
E52-CA35AY D=3.2
8M
Heat resistive E52-CA35AY D=3.2
NETU 1M
E52-CA35AY D=3.2
NETU 2M
E52-CA35AY D=3.2
NETU 4M
E52-CA35AY D=3.2
NETU 8M
50 Standard E52-CA50AY D=3.2
1M
E52-CA50AY D=3.2
2M
E52-CA50AY D=3.2
4M
E52-CA50AY D=3.2
8M
Heat resistive E52-CA50AY D=3.2
NETU 1M
E52-CA50AY D=3.2
NETU 2M
E52-CA50AY D=3.2
NETU 4M
E52-CA50AY D=3.2
NETU 8M
4.8 dia. 20 Standard E52-CA20AY D=4.8
1M
E52-CA20AY D=4.8
2M
E52-CA20AY D=4.8
4M
E52-CA20AY D=4.8
8M
Heat resistive E52-CA20AY D=4.8
NETU 1M
E52-CA20AY D=4.8
NETU 2M
E52-CA20AY D=4.8
NETU 4M
E52-CA20AY D=4.8
NETU 8M
35 Standard E52-CA35AY D=4.8
1M
E52-CA35AY D=4.8
2M
E52-CA35AY D=4.8
4M
E52-CA35AY D=4.8
8M
Heat resistive E52-CA35AY D=4.8
NETU 1M
E52-CA35AY D=4.8
NETU 2M
E52-CA35AY D=4.8
NETU 4M
E52-CA35AY D=4.8
NETU 8M
50 Standard E52-CA50AY D=4.8
1M
E52-CA50AY D=4.8
2M
E52-CA50AY D=4.8
4M
E52-CA50AY D=4.8
8M
Heat resistive E52-CA50AY D=4.8
NETU 1M
E52-CA50AY D=4.8
NETU 2M
E52-CA50AY D=4.8
NETU 4M
E52-CA50AY D=4.8
NETU 8M
6.4 dia. 20 Standard E52-CA20AY D=6.4
1M
E52-CA20AY D=6.4
2M
E52-CA20AY D=6.4
4M
E52-CA20AY D=6.4
8M
Heat resistive E52-CA20AY D=6.4
NETU 1M
E52-CA20AY D=6.4
NETU 2M
E52-CA20AY D=6.4
NETU 4M
E52-CA20AY D=6.4
NETU 8M
35 Standard E52-CA35AY D=6.4
1M
E52-CA35AY D=6.4
2M
E52-CA35AY D=6.4
4M
E52-CA35AY D=6.4
8M
Heat resistive E52-CA35AY D=6.4
NETU 1M
E52-CA35AY D=6.4
NETU 2M
E52-CA35AY D=6.4
NETU 4M
E52-CA35AY D=6.4
NETU 8M
50 Standard E52-CA50AY D=6.4
1M
E52-CA50AY D=6.4
2M
E52-CA50AY D=6.4
4M
E52-CA50AY D=6.4
8M
Heat resistive E52-CA50AY D=6.4
NETU 1M
E52-CA50AY D=6.4
NETU 2M
E52-CA50AY D=6.4
NETU 4M
E52-CA50AY D=6.4
NETU 8M
8 dia. 20 Standard E52-CA20AY D=8
1M
E52-CA20AY D=8
2M
E52-CA20AY D=8
4M
E52-CA20AY D=8
8M
Heat resistive E52-CA20AY D=8
NETU 1M
E52-CA20AY D=8
NETU 2M
E52-CA20AY D=8
NETU 4M
E52-CA20AY D=8
NETU 8M
35 Standard E52-CA35AY D=8
1M
E52-CA35AY D=8
2M
E52-CA35AY D=8
4M
E52-CA35AY D=8
8M
Heat resistive E52-CA35AY D=8
NETU 1M
E52-CA35AY D=8
NETU 2M
E52-CA35AY D=8
NETU 4M
E52-CA35AY D=8
NETU 8M
50 Standard E52-CA50AY D=8
1M
E52-CA50AY D=8
2M
E52-CA50AY D=8
4M
E52-CA50AY D=8
8M
Heat resistive E52-CA50AY D=8
NETU 1M
E52-CA50AY D=8
NETU 2M
E52-CA50AY D=8
NETU 4M
E52-CA50AY D=8
NETU 8M
Terminal type Protective
tubing diameter
D (mm)
Protective
tubing length L
(cm)
Lead wire type Lead wire length M (m)
1248
Model
11
E52
Exposed-lead Models
E52-IC@AY
Dimensions
J (IC) Model Information (E52-IC@AY)
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details
Terminal type Protective
tubing
diameter D
(mm)
Protective
tubing length
L (cm)
Lead wire
type
Lead wire length M (m)
124
Model
Exposed-lead
Models
1 dia. 15 Standard E52-IC15AY D=1 1M E52-IC15AY D=1 2M E52-IC15AY D=1 4M
Heat resistive E52-IC15AY D=1 NETU
1M
E52-IC15AY D=1 NETU
2M
E52-IC15AY D=1 NETU
4M
20 Standard E52-IC20AY D=1 1M E52-IC20AY D=1 2M E52-IC20AY D=1 4M
Heat resistive E52-IC20AY D=1 NETU
1M
E52-IC20AY D=1 NETU
2M
E52-IC20AY D=1 NETU
4M
35 Standard E52-IC35AY D=1 1M E52-IC35AY D=1 2M E52-IC35AY D=1 4M
Heat resistive E52-IC35AY D=1 NETU
1M
E52-IC35AY D=1 NETU
2M
E52-IC35AY D=1 NETU
4M
1.6 dia. 15 Standard E52-IC15AY D=1.6 1M E52-IC15AY D=1.6 2M E52-IC15AY D=1.6 4M
Heat resistive E52-IC15AY D=1.6
NETU 1M
E52-IC15AY D=1.6
NETU 2M
E52-IC15AY D=1.6
NETU 4M
20 Standard E52-IC20AY D=1.6 1M E52-IC20AY D=1.6 2M E52-IC20AY D=1.6 4M
Heat resistive E52-IC20AY D=1.6
NETU 1M
E52-IC20AY D=1.6
NETU 2M
E52-IC20AY D=1.6
NETU 4M
35 Standard E52-IC35AY D=1.6 1M E52-IC35AY D=1.6 2M E52-IC35AY D=1.6 4M
Heat resistive E52-IC35AY D=1.6
NETU 1M
E52-IC35AY D=1.6
NETU 2M
E52-IC35AY D=1.6
NETU 4M
L±3% 55
(80)
d
30±5
M±4% 90±10
D±0.05
Crimping terminal
Y type for M3.5
Product label
Sleeve (SUS304)
Sheath (ASTM316L)
Shrinkable tube
(CA:Blue, IC:Yellow)
Lead wire
Swage
Marking tube (White)
Transparent
Red (+)
White ()
Unit (mm)
Ddl
1 dia. 8 55
1.6 dia. 8 55
3.2 dia. 8 55
4.8 dia. 8 55
6.4 dia. 11 55
8 dia. 11 55
Permissible Temperature in Dry Air
D Element wire
J (IC)
ASTM316L
1 dia. 450°C
1.6 dia. 450°C
3.2 dia. 650°C
4.8 dia. 750°C
6.4 dia. 750°C
8.0 dia. 750°C
Note: 1. Lead Wire (Compensating Conductor)
Standard (20°C to 70°C):
Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm
thick) and external dimensions of 2.4 × 4.1.
Heat Resistive (0°C to 150°C):
Fully glass-wool-covered with seven 0.3-dia. conductors
(0.5 mm thick) with external shield of stainless steel and
external dimensions of 2.8 × 4.6
The heat-resistive lead wires cannot be used in locations
exposed to water or other liquids.
Lead Wire Length (M): 1, 2, 4, or 8 m
2. The sleeve resists temperatures ranging between 20°C and
70°C for standard models and 0°C and 100°C for heat-resistive
models.
E52
12
Exposed-lead
Models
3.2 dia. 15 Standard E52-IC15AY D=3.2 1M E52-IC15AY D=3.2 2M E52-IC15AY D=3.2 4M
Heat resistive E52-IC15AY D=3.2
NETU 1M
E52-IC15AY D=3.2
NETU 2M
E52-IC15AY D=3.2
NETU 4M
20 Standard E52-IC20AY D=3.2 1M E52-IC20AY D=3.2 2M E52-IC20AY D=3.2 4M
Heat resistive E52-IC20AY D=3.2
NETU 1M
E52-IC20AY D=3.2
NETU 2M
E52-IC20AY D=3.2
NETU 4M
35 Standard E52-IC35AY D=3.2 1M E52-IC35AY D=3.2 2M E52-IC35AY D=3.2 4M
Heat resistive E52-IC35AY D=3.2
NETU 1M
E52-IC35AY D=3.2
NETU 2M
E52-IC35AY D=3.2
NETU 4M
50 Standard E52-IC50AY D=3.2 1M E52-IC50AY D=3.2 2M E52-IC50AY D=3.2 4M
Heat resistive E52-IC50AY D=3.2
NETU 1M
E52-IC50AY D=3.2
NETU 2M
E52-IC50AY D=3.2
NETU 4M
4.8 dia. 20 Standard E52-IC20AY D=4.8 1M E52-IC20AY D=4.8 2M E52-IC20AY D=4.8 4M
Heat resistive E52-IC20AY D=4.8
NETU 1M
E52-IC20AY D=4.8
NETU 2M
E52-IC20AY D=4.8
NETU 4M
35 Standard E52-IC35AY D=4.8 1M E52-IC35AY D=4.8 2M E52-IC35AY D=4.8 4M
Heat resistive E52-IC35AY D=4.8
NETU 1M
E52-IC35AY D=4.8
NETU 2M
E52-IC35AY D=4.8
NETU 4M
50 Standard E52-IC50AY D=4.8 1M E52-IC50AY D=4.8 2M E52-IC50AY D=4.8 4M
Heat resistive E52-IC50AY D=4.8
NETU 1M
E52-IC50AY D=4.8
NETU 2M
E52-IC50AY D=4.8
NETU 4M
6.4 dia. 20 Standard E52-IC20AY D=6.4 1M E52-IC20AY D=6.4 2M E52-IC20AY D=6.4 4M
Heat resistive E52-IC20AY D=6.4
NETU 1M
E52-IC20AY D=6.4
NETU 2M
E52-IC20AY D=6.4
NETU 4M
35 Standard E52-IC35AY D=6.4 1M E52-IC35AY D=6.4 2M E52-IC35AY D=6.4 4M
Heat resistive E52-IC35AY D=6.4
NETU 1M
E52-IC35AY D=6.4
NETU 2M
E52-IC35AY D=6.4
NETU 4M
50 Standard E52-IC50AY D=6.4 1M E52-IC50AY D=6.4 2M E52-IC50AY D=6.4 4M
Heat resistive E52-IC50AY D=6.4
NETU 1M
E52-IC50AY D=6.4
NETU 2M
E52-IC50AY D=6.4
NETU 4M
8 dia. 20 Standard E52-IC20AY D=8 1M E52-IC20AY D=8 2M E52-IC20AY D=8 4M
Heat resistive E52-IC20AY D=8 NETU
1M
E52-IC20AY D=8 NETU
2M
E52-IC20AY D=8 NETU
4M
35 Standard E52-IC35AY D=8 1M E52-IC35AY D=8 2M E52-IC35AY D=8 4M
Heat resistive E52-IC35AY D=8 NETU
1M
E52-IC35AY D=8 NETU
2M
E52-IC35AY D=8 NETU
4M
50 Standard E52-IC50AY D=8 1M E52-IC50AY D=8 2M E52-IC50AY D=8 4M
Heat resistive E52-IC50AY D=8 NETU
1M
E52-IC50AY D=8 NETU
2M
E52-IC50AY D=8 NETU
4M
Terminal type Protective
tubing
diameter D
(mm)
Protective
tubing length
L (cm)
Lead wire
type
Lead wire length M (m)
124
Model
13
E52
Exposed-terminal Models
E52-CA@B-N
E52-IC@B-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
Permissible Temperature in Dry Air
Terminal box: The permissible temperature is 0°C to 100°C.
Note: The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-CA50B-N: L = 50 (cm), the sheath length L 40 = 500 40 = 460 mm.
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Enclosed-terminal Models
E52-CA@C-N
E52-IC@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
Permissible Temperature in Dry Air
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (+ or ).
Note: The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-CA35C-N: L = 35 (cm), the sheath length L 40 = 350 40 = 310 mm.
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
+
(15)
38.5
(52)
18
44
16
4
83.5
2×M3
22 dia. L-40±3%
2×10 dia.
D±0.05
Swage
Socket (SUS304)
Terminal box
Sheath (ASTM316L)
Product label
D Element wire
K (CA)
ASTM316L
J (IC)
ASTM316L
3.2 dia. 750°C650°C
4.8 dia. 800°C750°C
6.4 dia. 800°C750°C
8.0 dia. 900°C750°C
Element type Terminal type Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
3.2 dia. 4.8 dia. 6.4 dia. 8 dia.
Model
K (CA) Exposed-ter-
minal Models
20 E52-CA20B-N D=3.2 E52-CA20B-N D=4.8 E52-CA20B-N D=6.4 ---
35 E52-CA35B-N D=3.2 E52-CA35B-N D=4.8 E52-CA35B-N D=6.4 E52-CA35B-N D=8
50 E52-CA50B-N D=3.2 E52-CA50B-N D=4.8 E52-CA50B-N D=6.4 E52-CA50B-N D=8
75 --- E52-CA75B-N D=4.8 E52-CA75B-N D=6.4 E52-CA75B-N D=8
J (IC) Exposed-ter-
minal Models
20 E52-IC20B-N D=3.2 E52-IC20B-N D=4.8 E52-IC20B-N D=6.4 ---
35 E52-IC35B-N D=3.2 E52-IC35B-N D=4.8 E52-IC35B-N D=6.4 E52-IC35B-N D=8
50 E52-IC50B-N D=3.2 E52-IC50B-N D=4.8 E52-IC50B-N D=6.4 E52-IC50B-N D=8
75 --- E52-IC75B-N D=4.8 E52-IC75B-N D=6.4 E52-IC75B-N D=8
(66)
40
(15)
(66)
L-40±3%
D±0.05
58 dia.
Chain
Cap
Product label
Socket (SUS304)
Terminal box
Swage Sheath (ASTM316L)
(Packing internal diameter 6.5 dia.)
38
G
Use wiring terminals that fit M3 screws.
D Element wire
K (CA)
ASTM316L
J (IC)
ASTM316L
3.2 dia. 750°C650°C
4.8 dia. 800°C750°C
6.4 dia. 800°C750°C
8.0 dia. 900°C750°C
Element type Terminal type Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
3.2 dia. 4.8 dia. 6.4 dia. 8 dia.
Model
K (CA) Enclosed-ter-
minal Models
20 E52-CA20C-N D=3.2 E52-CA20C-N D=4.8 E52-CA20C-N D=6.4 ---
35 E52-CA35C-N D=3.2 E52-CA35C-N D=4.8 E52-CA35C-N D=6.4 E52-CA35C-N D=8
50 E52-CA50C-N D=3.2 E52-CA50C-N D=4.8 E52-CA50C-N D=6.4 E52-CA50C-N D=8
75 --- E52-CA75C-N D=4.8 E52-CA75C-N D=6.4 E52-CA75C-N D=8
J (IC) Enclosed-ter-
minal Models
20 E52-IC20C-N D=3.2 E52-IC20C-N D=4.8 E52-IC20C-N D=6.4 ---
35 E52-IC35C-N D=3.2 E52-IC35C-N D=4.8 E52-IC35C-N D=6.4 E52-IC35C-N D=8
50 E52-IC50C-N D=3.2 E52-IC50C-N D=4.8 E52-IC50C-N D=6.4 E52-IC50C-N D=8
75 --- E52-IC75C-N D=4.8 E52-IC75C-N D=6.4 E52-IC75C-N D=8
E52
14
Standard Thermocouples
Specifications
Note: Specify PT1 or PT0 if the element is R.
Permissible Temperature in Dry Air (See note.)
Note: For details on the permissible temperature, refer to Technical
Guide for Temperature Sensors.
Exposed-terminal Models
E52-CA@B-N
E52-IC@B-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Terminal box: The permissible temperature is 0°C to 100°C.
Note: The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-CA75B-N: L = 75 (cm), the protective tubing length L 50 = 750 50 = 700 mm.
Permissible Temperature in Dry Air
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Element wire K (CA), J(IC), R(PR)
Class K (CA), J (IC) JIS class 2 (0.75)
R(PR), JIS class 2 (0.25)
Protective tubing material K (CA) SUS316
J (IC) SUS316
R (See
note.)
JIS ceramic cat. 1 (PT1)
JIS special ceramic (PT0)
Thermal contact Non-grounded type
D Element wire
K (CA) SUS316 J (IC) SUS316
10 dia. 750°C 450°C
12 dia. 850°C 500°C
15 dia. 900°C 550°C
22 dia. 900°C 600°C
D Element wire
R
15 dia. 0°C to 1,400°C
D Element wire
K (CA) SUS316 J (IC) SUS316
10 dia. 750°C 450°C
12 dia. 850°C 500°C
15 dia. 850°C 550°C
22 dia. 900°C 600°C
Element type Terminal type Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
10 dia. 12 dia. 15 dia. 22 dia.
Model
K (CA) Exposed-ter-
minal Models
35 E52-CA35B-N D=10 E52-CA35B-N D=12 E52-CA35B-N D=15 ---
50 E52-CA50B-N D=10 E52-CA50B-N D=12 E52-CA50B-N D=15 E52-CA50B-N D=22
75 E52-CA75B-N D=10 E52-CA75B-N D=12 E52-CA75B-N D=15 E52-CA75B-N D=22
100 E52-CA100B-N D=10 E52-CA100B-N D=12 E52-CA100B-N D=15 E52-CA100B-N D=22
J (IC) Exposed-ter-
minal Models
35 E52-IC35B-N D=10 E52-IC35B-N D=12 E52-IC35B-N D=15 ---
50 E52-IC50B-N D=10 E52-IC50B-N D=12 E52-IC50B-N D=15 E52-IC50B-N D=22
75 E52-IC75B-N D=10 E52-IC75B-N D=12 E52-IC75B-N D=15 E52-IC75B-N D=22
100 E52-IC100B-N D=10 E52-IC100B-N D=12 E52-IC100B-N D=15 E52-IC100B-N D=22
8
8
30.8
70
49.5
(65.5)
25.5
25
18
3.8
18
534.5 (5)
D
9.6
2×M4
+
30 dia.
2×12 dia.
L-50±3%
Product label
Full-circled welding
Socket (SUS304)
Protective tubing (SUS316 or SUS310S)
Terminal box
15
E52
Enclosed-terminal Models
E52-CA@C-N
E52-IC@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Note: The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-CA50C-N: L = 50 (cm), the protective tubing length L 50 = 500 50 = 450 mm.
Permissible Temperature in Dry Air
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (+ or ).
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details
D Element wire
K (CA) SUS316 J (IC) SUS316
10 dia. 0 to 750°C 0 to 450°C
12 dia. 0 to 850°C 0 to 500°C
15 dia. 0 to 850°C 0 to 550°C
22 dia. 0 to 900°C 0 to 600°C
Element type Terminal type Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
10 dia. 12 dia. 15 dia. 22 dia.
Model
K (CA) Enclosed-ter-
minal Models
35 E52-CA35C-N D=10 E52-CA35C-N D=12 E52-CA35C-N D=15 ---
50 E52-CA50C-N D=10 E52-CA50C-N D=12 E52-CA50C-N D=15 E52-CA50C-N D=22
75 E52-CA75C-N D=10 E52-CA75C-N D=12 E52-CA75C-N D=15 E52-CA75C-N D=22
100 E52-CA100C-N D=10 E52-CA100C-N D=12 E52-CA100C-N D=15 E52-CA100C-N D=22
J (IC) Enclosed-ter-
minal Models
35 E52-IC35C-N D=10 E52-IC35C-N D=12 E52-IC35C-N D=15 ---
50 E52-IC50C-N D=10 E52-IC50C-N D=12 E52-IC50C-N D=15 E52-IC50C-N D=22
75 E52-IC75C-N D=10 E52-IC75C-N D=12 E52-IC75C-N D=15 ---
100 E52-IC100C-N D=10 E52-IC100C-N D=12 E52-IC100C-N D=15 ---
53
D
(5)
(86)
(92)
82 dia.
L-50±3%
38 dia.
Protective tubing (SUS316 or SUS310S)
Socket (SUS304)
Product
label Full-circled Welding
Terminal
box
(Packing internal diameter : 9 dia.)
Cap
Chain
12
G
E52
16
Enclosed-terminal Models (High-temperature Use)
E52-PR@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Note: The length L is in centimeters, but “150” is 150 millimeters.
Therefore, for the E52-PR75C-N: L = 75 (cm), the protective tubing length L 150 = 750 150 = 600 mm.
Model Information
Note: The permissible temperature given for the protective tubing is higher than 1,400°C, but the permissible temperature of the thermocouple
element wire is only 1,400°C. Therefore, the protective tubing of the E52-PR@C-N can withstand high temperatures momentarily to the
levels given in the table as exceptions, but the element wire will deteriorate quickly if the thermocouple is used regularly at temperatures
that exceed the permissible temperature for the element wire.
Element
type
Terminal
type
Protective
tubing
length L
(cm)
Protective tubing
diameter D (mm)
15 dia.
Model
R (See
note 1.)
Enclosed-ter-
minal Models
50 E52-PR50C-N D=15 PT1
75 E52-PR75C-N D=15 PT1
100 E52-PR100C-N D=15 PT1
R (See
note 2.)
Enclosed-ter-
minal Models
50 E52-PR50C-N D=15 PT0
75 E52-PR75C-N D=15 PT0
100 E52-PR100C-N D=15 PT0
Standard Protective tubing
material
Permissible
temperature in dry
air
Note 1:
JIS ceramic Cat.1
(PT1)
Mullite, high
alumina, etc.
1,500°C (See note.)
Note 2:
JIS special ceramic
(PT0)
Recrystallized
alumina, fused
alumina, etc.
1,600°C (See note.)
53
(5)
(100)
A
(86)
(92)
82 dia.
21.7 dia.
38 dia.
L-150±3%
* Tubing distortion
A dimensions more than 500mm:
0.6% or less
A dimensions are less than 500mm:
3mm or less
Support (SUS304)
Ceramic protective tubing (PT0 or PT1)
Product label
Terminal
box
Chain
Cap
(Packing internal diameter : 9 dia.)
12
G
15±0.7 dia.
*
Use wiring terminals that fit M4 screws.
Permissible Temperature in Dry Air
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (+ or ).
D Element wire
R
15 dia. 0°C to 1,400°C
17
E52
Low-cost Models
Low-cost Platinum Resistance Thermometers
Exposed-lead Models with Screws
Exposed-lead Models with Flange
Exposed-lead Models
Specifications
Element type Pt100
Conductor type 3-conductor system
Class Class B
Protective tubing
material
SUS304
Sensor length 30 mm
Max. detectable
temperature
250°C
Temperature
range
50°C to 250°C
Lead wire Fluororesin-covered
wire (PFA) with 1.0
outer dia.
7/0.18
50°C to 150°C
E52-P6DY
Dimensions
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m) Model
1 E52-P6DY 1M
2 E52-P6DY 2M
4 E52-P6DY 4M
14
(30)
15
(16)
(M-16)
M±5%
6±0.5
10±0.5
65 0
-2
4±0.4 dia.
Protective tubing
(SUS304)
Siliconized shrinkable tube
Product label
Lead wire
Marking tube (Red)
Red
Crimping terminal Y type for M3.5
White
Marking tube (White)
Full-circled welding
Taper screw for tube R1/8 (SUS304)
Red (A)
Black (B)
Black (B)
Specifications
Element wire Pt100
Conductor type 3-conductor system
Class Class B
Protective tubing
material
SUS304
Sensor length 30 mm
Max. detectable
temperature
250°C
Temperature
range
50°C to 250°C
Lead wire Fluororesin-covered
wire (PFA) with 1.0
outer dia.
7/0.18
50°C to 150°C
E52-P6FY
Dimensions
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m) Model
1 E52-P6FY 1M
2 E52-P6FY 2M
4 E52-P6FY 4M
15
1
120°
120°
30 dia.
20 dia. (30) (M-16)
3×3.5 dia.
65 0
-2 M±5%
Flange (SUS304)
Nickel brazing
Marking tube (Red)
White
Product label
Lead wire
Protective tubing
(SUS304)
Red
Siliconized shrinkable tube
Marking tube (White)
Crimping terminal Y type for M3.5
Red (A)
Black (B)
Black (B)
4±0.4 dia.
Specifications
Element type Pt100
Conductor type 3-conductor system
Class Class B
Protective tubing
material
SUS316
Max. detectable
temperature
250°C
Temperature
range
0°C to 250°C
Lead wire Fluororesin-covered
wire (PFA) with 1.0
outer dia.
7/0.18
50°C to 150°C
E52-P10AEY
Dimensions
Note: 1. The protective tubing is of pipe construction, which must not be bent.
2. A Compression Fitting (PT@) cannot be used for mounting.
Lead wire length (m) Model
1 E52-P10AEY 1M
2 E52-P10AEY 2M
4 E52-P10AEY 4M
30 80±10
M±4%
30±5
100±3%
Product label
Shrinkable tube (Black)
Protective tubing (SUS316)
Crimping terminal Y type for M3.5
Siliconized shrinkable tube Transparent
Marking tube
(White)
Lead wire
Red (A)
White (B)
White (B)
3.2±0.05 dia.
E52
18
Low-cost Thermocouples
Exposed-lead Models with Spring
Note: The protective tubing is of pipe construction, which must not be bent.
Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Element type: J (IC)
Model
65 1 E52-CA6ASY 1M E52-IC6ASY 1M
2 E52-CA6ASY 2M E52-IC6ASY 2M
4 E52-CA6ASY 4M E52-IC6ASY 4M
100 1 E52-CA10ASY 1M E52-IC10ASY 1M
2 E52-CA10ASY 2M E52-IC10ASY 2M
4 E52-CA10ASY 4M E52-IC10ASY 4M
150 1 E52-CA15ASY 1M E52-IC15ASY 1M
2 E52-CA15ASY 2M E52-IC15ASY 2M
4 E52-CA15ASY 4M E52-IC15ASY 4M
200 1 E52-CA20ASY 1M E52-IC20ASY 1M
2 E52-CA20ASY 2M E52-IC20ASY 2M
4 E52-CA20ASY 4M E52-IC20ASY 4M
+
(20) (70)
100°
L±332±2
18±1
6.3±1
5±0.5
M±1%
80±10
150±1
0
+0.02
-0.1
+0.2 Protective spring
(SUS304)
Sleeve
(Brass nickel chrome
plating)
Protective tubing
(SUS304)
Shrinkable tube
(CA:Blue, IC:Yellow)
Marking tube
(White)
Crimping terminal
Y type for M3.5
Lead wire
Red (+)
White ()
8.2±0.1 dia.
12±0.05 dia.
1.2±0.02 dia.
4.8 dia.
11±0.2 dia.
14.5 dia.
Specifications
Note: The sleeve resists temperatures ranging between 0°C
and 100°C.
Element type K (CA), J (IC)
Element dia. 0.65 mm (single wire)
Class Class 2 (0.75)
Protective tubing
material
SUS304
Thermal contact Non-grounded type
Temperature range 0°C to 400°C: K (CA)
0°C to 350°C: J (IC)
Lead wire Fully glass-wool-covered
compensating cable and external
dimensions of approx. 5.1 x 3.0
4/0.65
0°C to 180°C
E52-CA@ASY, E52-IC@ASY
Dimensions
L: Protective tubing length
M: Lead wire length
19
E52
Exposed-lead Models with Screw
Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Element type: J (IC)
Model
M6 screw 1 E52-CA1DY M6 1M E52-IC1DY M6 1M
2 E52-CA1DY M6 2M E52-IC1DY M6 2M
4 E52-CA1DY M6 4M E52-IC1DY M6 4M
M8 screw 1 E52-CA1DY M8 1M E52-IC1DY M8 1M
2 E52-CA1DY M8 2M E52-IC1DY M8 2M
4 E52-CA1DY M8 4M E52-IC1DY M8 4M
W1/4 screw 1 E52-CA1DY W1/4 1M E52-IC1DY W1/4 1M
2 E52-CA1DY W1/4 2M E52-IC1DY W1/4 2M
4 E52-CA1DY W1/4 4M E52-IC1DY W1/4 4M
120°
B
C
(70)
(20)
80±10
M±1%
A±0.3
3.8±1
9±1
1±0.1
3.8±0.1 dia.
5±0.05 dia.
10 -
0.5
0
0
2.8
+0.3
Shrinkable tube
(CA:Blue, IC:Yellow)
Lead wire
Screw
(SUS304) Protective
copper wire
Sleeve
(Brass nickel plated)
Blue
PVC less tube
Crimping terminal
Y type for M3.5
Marking tube (White)
End ring (Brass)
Movable ring (Brass) Red
Black ()
Red (+)
End Workpiece
Brass
0.65-dia.
black wire
Movable ring
Cut after silver
soldering
M6
Screw
Closely wound
enamel-bonded coil.
Brass pipe
Shielded
glass-wool lead
wire
Specifications
Note: 1. The thermocouple is a single wire from
the tip to the terminal.
2. Specify the type of screw (i.e., M6, M8, or
W1/4) when ordering.
3. The thermocouple is not of airtight
construction.
4. OMRON recommends that the tip of the
thermocouple is touching the sensing
object.
Installation Example
Cut a thread into the workpiece, and screw in the
thermocouple while pushing in so that the tip
makes complete contact.
Element type K (CA), J (IC)
Element dia. 0.65 mm (single wire)
Class Class 2 (0.75)
Protective tubing
material
SUS304
Thermal contact Grounded type
Temperature range 0°C to 400°C: K (CA)
0°C to 350°C: J (IC)
Lead wire Fully glass-wool-covered
with external copper
shield and external
dimensions of approx.
3.1 x 2.0
1/0.65
0°C to 180°C
Terminal shape Y-type crimp terminal for
M3.5
E52-CA1DY, E52-IC1DY
Dimensions
Lead wire
length (m)
Screw
W1/4
(P=1.27)
M6
(P=1.0)
M8
(P=1.25)
A (mm) 4.3 4 5.3
B (mm) 11.5 11.5 15
C (mm) 10 10 13
Note: E52-CA1DY with the same shape and multiple element wires are also available (E52-CA1DY-40).
Refer to page 29 for details.
Internal Construction (E52-CA1DY)
E52
20
Exposed-lead Models with Flange
Exposed-lead Models with Screws
Exposed-lead Models
Specifications
Element type K (CA), J (IC)
Class Class 2 (0.75)
Protective
tubing material
SUS304
Thermal contact Grounded type
Temperature
range
0°C to 350°C: K (CA)
0°C to 350°C: J (IC)
Lead wire
Fluororesin-covered
thermocouple wire (PFA) with
external dimensions of 1.6 x 1.0
1/0.32
0°C to 150°C
E52-CA6F-N, E52-IC6F-N
Dimensions
Note: 1. The thermocouple is a single wire from the tip to the terminal.
2. The protective tubing is of pipe construction, which must not be bent.
Lead wire
length (m)
Element type: K (CA) Element type: J (IC)
Model
1 E52-CA6F-N 1M E52-IC6F-N 1M
2 E52-CA6F-N 2M E52-IC6F-N 2M
4 E52-CA6F-N 4M E52-IC6F-N 4M
15
1(30)
(30)
120°
(75)
(10)
120°
(M-16)
20 dia.
30 dia.
3×3.5 dia.
65±2M±5%
80±10
Protective tubing
(SUS304)
Flange (SUS304)
Silver brazing Siliconized
shrinkable tube
Lead wire
Product label Peel treatment
Shrinkable tube
(CA:Blue, IC:Yellow)
White ()
Red (+)
4±0.05 dia.
Lead wire length (M): 1, 2, or 4 m
Specifications
Element type K (CA), J (IC)
Class Class 2 (0.75)
Protective
tubing material
SUS304
Thermal contact Grounded type
Temperature
range
0°C to 350°C: K (CA)
0°C to 350°C: J (IC)
Lead wire
Fluororesin-covered
thermocouple wire (PFA) with
external dimensions of 1.6 x 1.0
1/0.3
0°C to 150°C
E52-CA6D-N, E52-IC6D-N
Dimensions
Note: 1. The thermocouple is a single wire from the tip to the terminal.
2. The protective tubing is of pipe construction, which must not be bent.
Lead wire
length (m)
Element type: K (CA) Element type: J (IC)
Model
1 E52-CA6D-N 1M E52-IC6D-N 1M
2 E52-CA6D-N 2M E52-IC6D-N 2M
4 E52-CA6D-N 4M E52-IC6D-N 4M
(30) (M-16)
15
(30)
(10)
14
(16)
(75)
65±2M±5%
80±10
Full-circled welding
Protective tubing (SUS304)
Siliconized shrinkable tube
Lead wire
Product label Peel treatment
Shrinkable tube (CA:Blue, IC:Yellow)
Taper screw for tube
R
1
/
8
(SUS304)
White ()
Red (+)
4±0.05 dia.
Lead wire length (M): 1, 2, or 4 m
Specifications
Element type K (CA), J (IC)
Class Class 2 (0.75)
Protective
tubing material
SUS304
Thermal contact Non-grounded type
Temperature
range
0°C to 350°C: K (CA)
0°C to 200°C: J (IC)
Lead wire
Fluororesin-covered
thermocouple wire (PFA) with
external dimensions of 1.6 x 1.0
1/0.32
0°C to 180°C
E52-CA10AE-N, E52-IC10AE-N
Dimensions
Note: 1. The thermocouple is a single wire from the tip to the terminal.
2. Lead wire length M: 1, 2, or 4 m
3. The protective tubing is of pipe construction, which must not be bent.
4. The thermocouple cannot be mounted using a PT@ Compression Fitting.
Lead wire
length (m)
Element type: K (CA) Element type: J (IC)
Model
1 E52-CA10AE-N 1M E52-IC10AE-N 1M
2 E52-CA10AE-N 2M E52-IC10AE-N 2M
4 E52-CA10AE-N 4M E52-IC10AE-N 4M
(10)
(75)
(30)
100±5M±5% 80±10
Protective tubing
(SUS304)
Swage Lead wire
Product label
Shrinkable tube
(CA:Blue, IC:Yellow)
Fluorocarbon resin protective tubing
Peel treatment
White ()
Red (+)
3.2±0.05 dia.
21
E52
Exclusive Models
Thermocouples
Thermocouples for Molding Machines
Thermocouples with Crimp Terminals
15 20 (30)
10
1510
(80)
85±10
25±2100±10
M±5%
15 dia. 6.8 dia.
5 dia.
8 dia.12 dia.
Product label
Shrinkable tube
(CA:Blue, IC:Yellow)
Red
White
White/Red Stripes (+)
CA: White/Blue Stripes ()
IC: White/Yellow Stripes ()
Lead wire
Spring retainer
(Brass nickel plated)
Spring
Bayonet
(Brass nickel plated)
Protective tubing
(SUS304)
Taper screw for tube
R
1
/
8 (Brass nickel plated)
Details of mounting bracket
Marking tube
(White)
Marking tube
(Red)
Crimping terminal
Y type for M3.5
4.8±0.05 dia.
Specifications
Element type K (CA), J (IC)
Element
diameter
1.0 mm (single wire)
Class Class 2 (0.75)
Protective
tubing material
SUS304
Thermal contact Grounded type
Temperature
range
0°C to 350°C
Lead wire Glass-covered stainless steel
shielded thermocouple wire
with 4 dia.
1/1.0
0°C to 180°C
E52-CA2GVY, E52-IC2GVY
Dimensions
Lead wire
length (m)
Element type: K (CA) Element type: J (IC)
Model
1 E52-CA2GVY 1M E52-IC2GVY 1M
2 E52-CA2GVY 2M E52-IC2GVY 2M
Note: The Adapter is included with
the Thermocouple.
If it is lost or damaged, you can
order a replacement with the
following model number.
Adapter: Y92F-S1
Lead wire length (M): 1 or 2 m
Specifications
Note: The E52-CA1GTY is also available with double
elements. Refer to page 29 for details.
Element type K (CA), J (IC)
Element
diameter
0.65 mm (single wire)
Class Class 2 (0.75)
Thermal contact Grounded type
Temperature
range
0°C to 300°C
Lead wire Glass-covered stainless steel
shielded thermocouple wire
with 4 dia.
1/1.0
0°C to 150°C
Terminal shape Y-type crimp terminal for M3.5
E52-CA1GTY, E52-IC1GTY
Dimensions
Lead wire
length (m)
Element type: K (CA) Element type: J (IC)
Model
1 E52-CA1GTY 1M E52-IC1GTY 1M
2 E52-CA1GTY 2M E52-IC1GTY 2M
(80)
8
White ()
15±5
Max. 6 dia.
4.3 dia.
30±5
M±4%
90±10
Crimping terminal Y type for M3.5
Crimping terminal
round type for M4
(N1.25-4)
Siliconized
shrinkable tube
Lead wire
Shrinkable tube
(CA:Blue, IC:Yellow)
Transparent vinyl tube
Marking tube
(White)
Transparent
White/Red Stripes (+)
Temperature
measuring junction
Product label
Lead wire length (M): 1 or 2 m
E52
22
Platinum Resistance Thermometers
Platinum Resistance Thermometers for Surface Temperature Measurement
Platinum Resistance Thermometers for Room Temperature Measurement
Waterproof Platinum Resistance Thermometers
Specifications
Element type Pt100
Class Class B
Protective
tubing material
SUS304
With brass-nickel-
plated bracket
Conductor type 3-conductor system
Temperature
range
50°C to 250°C
Lead wire Silicone-covered
3-conductor cable
and approx. 3.9 dia.
30/0.08
50°C to 150°C
E52-P2GSY
Dimensions
Lead wire length (m) Model
1 E52-P2GSY 1M
2 E52-P2GSY 2M
(
30
)
(50) (80)
5
3
1.5
6
4.5
20±0.5
28±1
30±5
90±10M±4%
20±1
14±0.5
4×3.2 dia. (7.5 dia.)
Crimping terminal Y type for M3.5
Shrinkable tube
(Black)
Siliconized shrinkable tube
Blacket
(Brass nickel plated)
Transparent
Lead wire
Marking tube (White)
Product label Red (A)
White (B)
White (B)
Lead wire length (M): 1 or 2 m
(95)
(30)
60
85
(80)
85±10
M±5%
97±1
100±4
4.5±1
4.8 dia.
8 dia.
56±1
69.5±1
42±1
2×8 dia.
70±1
Red
Shrinkable tube (Black)
Lead wire
Protective tubing
(SUS304)
Protective piping
(Brass nickel plated)
Terminal box
Chain
Product label
Crimping terminal Y type for M3.5
Marking tube (Red)
Marking tube (White)
White
Red (A)
White (B)
Black (B)
22.2±1 dia.
Specifications
Element type Pt100
Class Class B
Protective
tubing material
SUS304
Conductor type 3-conductor system
Temperature
range
50°C to 60°C
Lead wire Vinyl-covered 3-conductor
cable with 6.1 dia.
20/0.18
25°C to 60°C
E52-P10GRY
Dimensions
Lead wire length (m) Model
2 E52-P10GRY 2M
Specifications
Element wire Pt100
Class Class B
Protective tubing
material
SUS304
Conductor type 3-conductor system
Temperature range 0°C to 70°C (underwater)
20°C to 70°C (in the air)
Lead wire
Vinyl-covered 3-conductor
cable with 6.1 dia.
12/0.18
25°C to 60°C
Resistive pressure 981 kps
E52-P10GPY
Dimensions
Note: The lead wires are vinyl-covered, and cannot be used underwater.
Use the E52-P5AY-40 if waterproof lead wires are required for use underwater.
Refer to page 24 for details.
Lead wire length (m) Model
2 E52-P10GPY 2M
4 E52-P10GPY 4M
(80)
12
62 5
(30)
100±2M±5%
85±10
20 dia.
Red
White
Marking tube (White)
Full-circled
Welding
Sleeve (SUS304)
Lead wire Product label
Shrinkable tube (Black) Crimping terminal
Y type for M3.5
Marking tube (Red)
Protective tubing
(SUS304)
Red (A)
White (B)
Black (B)
7±0.2 dia.
Lead wire length (M): 1 or 2 m
23
E52
Corrosion-resistant Models with Fluororesin-covered
Protective Tubing
Thermocouples
Exposed-lead Models
Platinum Measurement
Exposed-lead Models
22
8
55
(80)
d
(L-5)
D±0.1
Ds±0.05
L0
+4
5-5
+9
M±4%
30±5
90±10
Shrinkable tube
(CA:Blue, IC:Yellow)
Crimping terminal Y type for M3.5
Marking tube (White)
Product label
Lead wire
Sleeve (SUS304)
Fixed with adhesive tape and
siliconized shrinkable tube
FEP-covered tubing
Transparent
Sheath (ASTM316L)
White ()
Red (+)
E52-CA20AY-1
Dimensions
Model Protective
tubing
diameter
Sleeve
diameter
(mm)
Sleeve length
(mm)
tube
thickness
(mm)
Lead wire
length (m)
E52-CA20AY-1 D=4.6 2M
D = 4.6 d = 8
l = 55
0.7 0.5
E52-CA20AY-1 D=6 2M D = 6.0 0.6
E52-CA20AY-1 D=8 2M D = 8.0 d = 11
l = 55
0.8
Specifications
Element type K (CA)
Class Class 2 (0.75)
Protective tubing
material
ASTM316L with
Fluororesin-covered
(FEP) tube
Thermal contact Non-grounded type
Temperature range 0°C to 180°C
Lead wire Vinyl-covered: 20°C
to 70°C
(30)
35
A
(10)
(20)
(10)
(80)
85±10
M±4%
L+5 ±3%
D±0.1
Ds±0.05
8
dia.
Fixed with adhesive tape and
siliconized shrinkable tube
Sheath (SUS316)
FEP-covered
tubing
Sleeve (SUS304)
Product label
Shrinkable tube (Black)
Lead wire
Crimping terminal Y type for M3.5
Tube nose shape :
Round Marking tube
(Red)
Marking tube
(White)
Red
White
Red (A)
White (B)
Black (B)
E52-P20AY-1
Dimensions
Model Protective
tubing
diameter
Sleeve
diameter
(mm)
Coating
thickness
(mm)
Lead wire
length (m)
E52-P20AY-1 D=4.6
2M
D = 4.6 d = 8 0.7 2
E52-P20AY-1 D=6 2M D = 6.0 d = 8 0.6
E52-P20AY-1 D=8 2M D = 8.0 d = 8 0.8
Specifications
Element type Pt100
Class Class B
Protective tubing
material
SUS316 with
Fluororesin-covered
(FEP) tube
Conductor type 3-conductor system
Temperature range 80°C to 180°C
Lead wire Vinyl-covered: 20°C
to 70°C
E52
24
FEP-molded Models (Completely Waterproof)
(80)
90±10
30±5
M±4%
65 -1
+4
6 dia.
-0.5
+0.1 FEP tube
Fusion
(Completely waterproof)
Lead wire Product label
Shrinkable tube (Black)
Crimping terminal Y type for M3.5
Marking tube (White)
Transparent
Red (A)
White (B)
White (B)
E52-P5AY-40
Dimensions
Model Lead wire length (m)
E52-P5AY-40 2M 2
E52-P5AY-40 4M 4
E52-P5AY-40 6M 6
E52-P5AY-40 8M 8
Specifications
Element type Pt100
Class Class B
Protective tubing
material
Fluororesin (FEP) tube
(element / fluororesin
mold (FEP))
Conductor type 3-conductor system
Temperature range 50°C to 180°C
Lead wire
Fluororesin (FEP)
cover (with outer
cover)
: 50°C to 180°C
25
E52
Pressure-resistant Explosion-proof (IICT6) Models
Thermocouples
Enclosed-terminal Models
70
L1=50
L
(64.5)
(113)
(10)
(131.5)
110
15 dia.
L2±3%
6.4±0.05 dia.
Cap
Official approval success label
Chain
Support (SUS304)
Socket (SUS304)
Full-circled Welding
Sheath (ASTM316L)
Pressure-resistant explosion-proof
cable ground
(Adopted cable diameter: for 9-10 dia.)
Back: Product label
Terminal box
Explosion-proof display label
Specifications
Element type K (CA)
Class Class 2 (0.75)
Class 3 (Level 1.5) at -
40
°
C and under
Protective tubing material L2 section: ASTM316L
L1 section: SUS304
Explosion-
proof
specifica-
tions
Construction Pressure-resistant
explosion-proof structure
Explosion-protected
class and ignitability
IICT6
Explosion-proof
temperature range
20°C to 85°C
Lead wire wiring
method
Pressure-resistant
packing cable ground type
Conduit thread G1/2
Installation method Conforms to Technical
Recommendations of the
Research Institute of
Industrial Safety (Japan)
Model Protective
tubing length
L (cm)
Protective
tubing
diameter
L2
(mm)
E52-CA20C-N-6 D=6.4 L2=150 20 D = 6.4 150
E52-CA35C-N-6 D=6.4 L2=300 35 D = 6.4 300
E52-CA50C-N-6 D=6.4 L2=450 50 D = 6.4 450
E52-CA75C-N-6 D=6.4 L2=700 75 D = 6.4 700
E52-CA@@C-N-6
Dimensions
E52
26
Platinum Resistance Thermometers for Surface Temperature Measurement
Enclosed-terminal Models
Model Protective
tubing length
L (cm)
Protective
tubing
diameter
L2
(mm)
E52-P20C-N-6 D=6.4 L2=150 20 D = 6.4 150
E52-P35C-N-6 D=6.4 L2=300 35 D = 6.4 300
E52-P50C-N-6 D=6.4 L2=450 50 D = 6.4 450
E52-P75C-N-6 D=6.4 L2=700 75 D = 6.4 700
70
L1=50
L
(64.5)
(113)
(10)
(131.5)
110
L2±3%
6.4±0.05 dia.
15 dia.
Official approval success label
Support (SUS304)
Socket (SUS304)
Full-circled Welding
Sheath (ASTM316L)
Pressure-resistant explosion-proof
cable ground
(Adopted cable diameter: for 9-10 dia.)
Explosion-proof display label
Back: Product label
Terminal box
Cap
Chain
Specifications
Element type Pt100
Class Class B
Protective tubing material L2 section: ASTM316L
L1 section: SUS304
Explosion-
proof
specifica-
tions
Construction Pressure-resistant
explosion-proof structure
Explosion-protected
class and ignitability
IICT6
Explosion-proof
temperature range
20°C to 85°C
Lead wire wiring
method
Pressure-resistant
packing cable ground type
Conduit thread G1/2
Installation method Conforms to Technical
Recommendations of the
Research Institute of
Industrial Safety (Japan)
E52-P@@C-N-6
Dimensions
27
E52
Double-element Models
Thermocouple
Exposed-lead Models
Platinum Resistance Thermometers
Exposed-lead Models
E52-CA20AY-7
Dimensions
Specifications
Element type K (CA)
Class Class 2 (0.75)
Protective tubing
material
ASTM316L
(with sheath)
Thermal contact Non-grounded type
Temperature
range
0°C to permissible
temperature limit
Lead wire Vinyl-covered with
external dimensions of
2.4 x 4.1
7/0.3
20°C to 70°C
(80)
55
L±3%
30±5
M±4%
90±10
11 dia.
D±0.05
Lead wire
Product label
Sleeve (SUS304)
Sheath (ASTM316L) Swage
Crimping terminal Y type for M3.5
Transparent
Marking tube
(White)
Shrinkable tube (Blue)
White ()
Red (+)
White ()
Red (+)
Permissible Temperature in Dry Air
DElement wire
K (CA)
ASTM316L
3.2 dia. 750°C
4.8 dia. 800°C
6.4 dia. 800°C
8.0 dia. 900°C
Model Protective
tubing
diameter
Sleeve
diameter
(mm)
Permissible
Temperature
(°C)
Lead wire
length (m)
E52-CA20AY-7 D=3.2
2M
D = 3.2 d = 11 750 2
E52-CA20AY-7 D=4.8
2M
D = 4.8 d = 11 800 2
E52-CA20AY-7 D=6.4
2M
D = 6.4 d = 11 800 2
E52-CA20AY-7 D=8.0
2M
D = 8.0 d = 11 900 2
(80)
55
1
2
90±10M±4%L±3%
30±5
11 dia.
D±0.05
Swage
Sheath (ASTM316L) Product label
Shrinkable tube (Black)
Wire mark (1,2) (White)
Sleeve (SUS304)
Crimping terminal
Y type for M3.5
Transparent
Marking tube
(White)
Lead wire
Contradistinctive view
Red (A)
Red (A)
White (B)
White (B)
White/Black
Stripes (B)
White/Black
Stripes (B)
E52-P20AY-7
Dimensions
Specifications
Element type Pt100
Class Class B
Protective tubing
material
ASTM316L
(with sheath)
Conductor type 3-conductor system
Temperature
range
200°C to 450°C
Lead wire Vinyl-covered with 6.5
dia.
19/0.18
20°C to 70°C
Model Protective
tubing diameter
Lead wire
length (m)
E52-P20AY-7 D=4.8 2M D = 4.8 2
E52-P20AY-7 D=6.4 2M D = 6.4 2
E52
28
Enclosed-terminal Models
Note: The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-P20C-N-7: L = 20 (cm), the sheath length L 50 = 200 50 = 150 mm.
53
(15)
L-50±3%
82 dia. 38 dia.
(92)
(86)
D±0.05
Chain
Cap
G
3
/
4
(Packing internal
diameter : 12 dia.)
Socket (SUS304)
Product label
Swage
Terminal box
Sheath (ASTM316L)
E52-P20C-N-7
Dimensions
Specifications
Element type Pt100
Class Class B
Protective tubing
material
ASTM316L
(with sheath)
Conductor type 3-conductor system
Temperature range 200°C to 450°C
Model Protective tubing
length L (cm)
Protective
tubing diameter
E52-P20C-N-7 D=4.8 20 D = 4.8
E52-P20C-N-7 D=6.4 20 D = 6.4
29
E52
Silicone-covered Lead Wires Models
Thermocouples
Exposed-lead Models with Screws
Specifications
Note: Refer to the installation example for the E52-CA1DY.
E52-CA1DY-40
Dimensions
Thermocouples with Crimp Terminals
Specifications
E52-CA1GTY-14
Dimensions
Element type K (CA)
Class Class 2 (0.75)
Screw material SUS304
Thermal contact Grounded type
Temperature range 0°C to 300°C
Lead wire Silicone-covered with external dimensions of 3.5 x 4.9
30/0.1
0°C to 150°C
Terminal shape Y-type crimp terminal for M3.5
Model Screw pitch Lead wire
length (m)
E52-CA1DY-40 M6 1M M6 (P=1.0) 1
E52-CA1DY-40 M6 2M M6 (P=1.0) 2
E52-CA1DY-40 M6 4M M6 (P=1.0) 4
Element type K (CA)
Class Class 2 (0.75)
Thermal contact Grounded type
Temperature range 0°C to 200°C
Lead wire Silicone-covered compensating cable with external dimensions of 3.2 x 4.6
30/0.1
0°C to 150°C
Terminal shape Y-type crimp terminal for M3.5
8±0.05 dia.
0
6.5 dia.
+0.05
0.6 dia.
(20)
120°
3.8±0.1 dia.
B
C
(70)
80±10
M±1%
A±0.3
13±1
80±5
1±0.1
10 -
0.5
0
0
2.8
+0.3
Lead wire
Blue
Marking tube (White)
Crimping terminal Y type for M3.5
Movable ring (Brass)
Screw (SUS304)
Sleeve (Brass nickel plated)
Shrinkable tube (Blue)
Protective spring (SUS304) Red
End ring (Brass)
White ()
Red (+)
6.6
4.3 dia.
Max. 7 dia.
15±530±5(80)
90±10
M±4%
Lead wire
Siliconized shrinkable tube
Shrinkable tube
(CA:Blue, IC:Yellow)
Crimping terminal Y type for M3.5
Product label
Transparent
Marking tube (White)
Crimping terminal round type for M4 (N1.25-4)
White ()
Red (+)
Lead wire length (M): 1 or 2 m
Model Lead wire length (m)
E52-CA1GTY-14 1M 1
E52-CA1GTY-14 2M 2
E52
30
Thermistors
Element Interchangeable Thermistor for E5CS and E5C2
Temperature Ranges
Specifications
Error
Permissible Temperature
Note: Models with non-standard lead wire length and protective
tubing length are available on request.
This Thermistor is a dedicated Thermistor for the E5C2 and E5CS.
Temperature
range
Color code Nominal resistance Thermistor
constant
Lead wire
50°C to 50°CBlue 6 kΩ (0°C) 3390K A pair of 0.12 dia. 7 Fluororesin-insulated stranded wires with
0.86 outer dia. each
0°C to 100°CBlack 6 kΩ (0°C) 3390K
50°C to 150°C Red 30 kΩ (0°C) 3450K
100°C to 200°C Yellow 0.55 kΩ (200°C) 4300K
150°C to 300°C Green 4 kΩ (200°C) 5133K Flat glass-wool-shielded lead cable with 0.12 dia. 10 conductors
and external dimensions of 2.5 × 1.55
Item E52-THE@@
Coupling method Element interchangeable thermistor
Class JIS class 1
Protective tubing material SUS304
Time constant 8 to 15 s in still water
Dissipation factor 2.4 to 2.8 mW/°C in still air
Lead wire heat resistive
temperature
180°C
Detectable temperature Error
50°C to 100°C±1°C max.
100°C to 350°C±1% max. of detectable temperature
Detectable temperature Operating temperature
50°C to 50°C 100°C
0°C to 100°C 150°C
50°C to 150°C 200°C
100°C to 200°C 250°C
150°C to 300°C 350°C
31
E52
Exposed-lead Models
E52-THE5A
Dimensions
Note: The lead wires have no polarity
Exposed-lead Models with Screws
E52-THE6D
Dimensions
Note: The lead wires have no polarity
Exposed-lead Models with Flange
E52-THE6F
Dimensions
Note: The lead wires have no polarity
Note: 1. The Thermistor lead cable can be extended with a standard lead wire for extension.
2. Be sure to specify the model and temperature range when ordering the Thermistor. The Thermistor has a color code according to the
temperature range.
(50) (10)
(5) (4)
4±0.08 dia.
50±1M±5%
(15)
Protective tubing
(SUS304)
Swage Lead wire
Protective tube Peel treatment
Marking tube
Transparent
Temperature range Model
50°C to 50°C E52-THE5A 50-50°C 1M
0°C to 100°C E52-THE5A 0-100°C 1M
50°C to 150°C E52-THE5A 50-150°C 1M
100°C to 200°C E52-THE5A 100-200°C 1M
150°C to 300°C E52-THE5A 150-300°C 1M
610
65±1
(5) (4)
M±5%
(10)
(15)
(15) (50)
14
(16)
4±0.08 dia.
Protective tubing
(SUS304) Lead wire
Protective tube Peel treatment
Marking tube
Transparent
Swage
Tapered
screw
for tube
R
1
/
8
(SUS304)
Temperature range Model
50°C to 50°C E52-THE6D 50-50°C 1M
0°C to 100°C E52-THE6D 0-100°C 1M
50°C to 150°C E52-THE6D 50-150°C 1M
100°C to 200°C E52-THE6D 100-200°C 1M
150°C to 300°C E52-THE6D 150-300°C 1M
120°
120°
20 dia.
30 dia.
3×3.5 dia.
4±0.08 dia.
65±1M±5%
(10)
(50)
(5)
(1)
(4)
(15)
(15)
Protective tubing
(SUS304) Lead wire
Protective tube
Peel treatment
Marking tube
Silver brazing
Transparent
Flange (SUS304)
Swage
Temperature range Model
50°C to 50°C E52-THE6F 50-50°C 1M
0°C to 100°C E52-THE6F 0-100°C 1M
50°C to 150°C E52-THE6F 50-150°C 1M
100°C to 200°C E52-THE6F 100-200°C 1M
150°C to 300°C E52-THE6F 150-300°C 1M
32
E52 (Ferrule)
General-purpose Models (with Ferrule)
Model Number Legend
The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.
Platinum Resistance Thermometers
1. Element type
P: Pt100
2. Protective tubing length (L)
Specify the length in centimeters within the following range:
Unit (cm)
E52-P@AF
3. Terminal
AF: Exposed lead wires (with Ferrule)
4. Diameter
3.2: 3.2-mm dia. (Protective tubing construction: Sheathed)
E52-@@AF only
4.8: 4.8-mm dia. (Protective tubing construction: Sheathed)
E52-@@AF only
6.4: 6.4-mm dia. (Protective tubing construction: Sheathed)
E52-@@AF only
5. Heat resistance
Specify for E52-P@AF model only.
6. Lead length (M)
Specify the length in meters within the following range for the E52-
@@AF only:
Range: 0.5, 1 to 100 m
Examples
Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-P42AF D=4.8 NETU 10M
Sheathed Platinum Resistance Thermometers
Refer to Model Number Legend above for the Pt100.
Specifications
Diameter (D) Length (L)
3.2 7 to 100
4.8 10 to 600
6.4 13 to 1,300
Code Temperature range Lead type
--- 20°C to 70°C
Sleeve: 0°C to 70°C
Vinyl-covered
NETU 0°C to 180°C
Sleeve: 0°C to 100°C
Glass-wool-covered,
externally shielded with
stainless
Element type Pt100
Class JIS class B
Sheath material SUS316 (E52-P@AF)
ASTM316L (E52-P@B-N, E52-P@C-N)
Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia., 8 dia
Conductor type 3-conductor system
Temperature range 196°C to 450°C (in dry air)
33
E52 (Ferrule)
Exposed-lead Models
E52-P@AF
Dimensions
Model Information
Custom-made models are available on request. Refer to page 32 for details.
Terminal type Protective
tubing
diameter D
(mm)
Protective
tubing length
L (cm)
Lead wire
type
Lead wire length M (m)
1248
Model
Exposed-lead
Models
3.2 dia. 15 Standard E52-P15AF D=3.2
1M
E52-P15AF D=3.2
2M
E52-P15AF D=3.2
4M
E52-P15AF D=3.2
8M
Heat resistive E52-P15AF D=3.2
NETU 1M
E52-P15AF D=3.2
NETU 2M
E52-P15AF D=3.2
NETU 4M
E52-P15AF D=3.2
NETU 8M
20 Standard E52-P20AF D=3.2
1M
E52-P20AF D=3.2
2M
E52-P20AF D=3.2
4M
E52-P20AF D=3.2
8M
Heat resistive E52-P20AF D=3.2
NETU 1M
E52-P20AF D=3.2
NETU 2M
E52-P20AF D=3.2
NETU 4M
E52-P20AF D=3.2
NETU 8M
35 Standard E52-P35AF D=3.2
1M
E52-P35AF D=3.2
2M
E52-P35AF D=3.2
4M
E52-P35AF D=3.2
8M
Heat resistive E52-P35AF D=3.2
NETU 1M
E52-P35AF D=3.2
NETU 2M
E52-P35AF D=3.2
NETU 4M
E52-P35AF D=3.2
NETU 8M
4.8 dia. 20 Standard E52-P20AF D=4.8
1M
E52-P20AF D=4.8
2M
E52-P20AF D=4.8
4M
E52-P20AF D=4.8
8M
Heat resistive E52-P20AF D=4.8
NETU 1M
E52-P20AF D=4.8
NETU 2M
E52-P20AF D=4.8
NETU 4M
E52-P20AF D=4.8
NETU 8M
35 Standard E52-P35AF D=4.8
1M
E52-P35AF D=4.8
2M
E52-P35AF D=4.8
4M
E52-P35AF D=4.8
8M
Heat resistive E52-P35AF D=4.8
NETU 1M
E52-P35AF D=4.8
NETU 2M
E52-P35AF D=4.8
NETU 4M
E52-P35AF D=4.8
NETU 8M
50 Standard E52-P50AF D=4.8
1M
E52-P50AF D=4.8
2M
E52-P50AF D=4.8
4M
E52-P50AF D=4.8
8M
Heat resistive E52-P50AF D=4.8
NETU 1M
E52-P50AF D=4.8
NETU 2M
E52-P50AF D=4.8
NETU 4M
E52-P50AF D=4.8
NETU 8M
B
A
B
SUS304
sleeve
Sheath
(SUS316)
Lead wireCaulking
D±0.05
L±3%
Product label Red (A)
White (B)
Black (B)
Ferrule *
Maker tube
Turquoise
M±4% 85±10
Shrinkable tube (black)
(30)
40
8 dia.
Lead Wire
Standard (20°C to 70°C):
Fully vinyl-covered with twelve 0.18-dia
conductors (0.3 mm thick) and 4.8 mm
in outer dia. The sleeve resists a
temperature range between 0°C and
70°C.
Heat Resistive (0°C to 180°C):
Fully glass-wool-covered with thirty
0.12-dia. conductors (0.3 mm thick)
externally shielded with stainless steel,
4 mm in outer dia. The sleeve resists a
temperature range between 0°C and
100°C.
Lead Wire Length (M): 1, 2, 4, or 8 m
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
E52 (Ferrule)
34
Model Number Legend
The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.
Thermocouples
1. Element type
CA:K
2. Protective tubing length (L)
Specify the length in centimeters in the following range: Unit (cm)
E52-CA@AF (Exposed-lead Model)
3. Terminal
AF: Exposed lead wires (with Ferrule) (element type: K, J)
4. Diameter
Specify the protective tubing material according to the table.
5. Heat resistance
Specify this item for the exposed-lead models only.
6. Lead length (M)
Specify the length in meters in the following range for the E52-CA@AF only.
Range: 1 to 100 m
7. Protective tubing material
Examples
Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-CA@AF D=4.8 NETU 10M
Diameter (D) Length (L)
1 2 to 200
1.6 3 to 500
3.2 5 to 2,000
4.8 8 to 2,300
6.4 10 to 1,200
8 12 to 1,000
Code Diameter
(D)
Protective tubing
construction
Protective tubing
material
1 1 mm Sheathed ASTM316L
1.6 1.6 mm Sheathed ASTM316L
3.2 3.2 mm Sheathed ASTM316L
4.8 4.8 mm Sheathed ASTM316L
6.4 6.4 mm Sheathed ASTM316L
8 8 mm Sheathed ASTM316L
Code Temperature range Lead type
--- 20°C to 70°C
Sleeve: 0°C to 70°C
Vinyl-covered
NETU 0°C to 150°C
Sleeve: 0°C to 100°C
Glass-wool-covered with exter-
nal shield of stainless
Code Protective tubing
material
Element type
--- ASTM316L K
35
E52 (Ferrule)
Sheathed Thermocouples
Specifications Permissible Temperature in Dry Air
Note: For details on the permissible temperature, refer to page D-5 of
Introduction of Temperature Controllers (Cat. No. H900).
Exposed-lead Models
E52-CA@AF
Dimensions
Element type K (CA)
Class JIS class 2 (0.75)
Thermal contact Non-grounded type
Sheath material CA: ASTM316L
IC: ASTM316L
D Element wire
K (CA)
ASTM316L
1 dia. 650°C
1.6 dia. 650°C
3.2 dia. 750°C
4.8 dia. 800°C
6.4 dia. 800°C
8.0 dia. 900°C
Maker tube
White
Lead wire
Shrinkable tube (blue)
Product label Red (+)
White ()
Ferrule *
SUS304
sleeve
Caulking
D±0.05
L±3% M±4% 90±10
55
d
30±5 (80)
Sheath
(ASTM316L)
Unit (mm)
Ddl
1 dia. 8 55
1.6 dia. 8 55
3.2 dia. 8 55
4.8 dia. 8 55
6.4 dia. 11 55
8 dia. 11 55
Permissible Temperature in Dry Air
D Element wire
J (IC)
ASTM316L
1 dia. 450°C
1.6 dia. 450°C
3.2 dia. 650°C
4.8 dia. 750°C
6.4 dia. 750°C
8.0 dia. 750°C
Note: 1. Lead Wire (Compensating Conductor)
Standard (20°C to 70°C):
Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm
thick) and external dimensions of 2.4 × 4.1.
Heat Resistive (0°C to 150°C):
Fully glass-wool-covered with seven 0.3-dia. conductors
(0.5 mm thick) with external shield of stainless steel and
external dimensions of 2.8 × 4.6
The heat-resistive lead wires cannot be used in locations
exposed to water or other liquids.
Lead Wire Length (M): 1, 2, 4, or 8 m
2. The sleeve resists temperatures ranging between 20°C and
70°C for standard models and 0°C and 100°C for heat-resistive
models.
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
E52 (Ferrule)
36
K (CA) Model Information (E52-CA@AF)
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 34 for details.
Terminal type Protective
tubing diameter
D (mm)
Protective
tubing length L
(cm)
Lead wire type Lead wire length M (m)
1248
Model
Exposed-lead
Models
1 dia. 15 Standard E52-CA15AF D=1 1M E52-CA15AF D=1 2M E52-CA15AF D=1 4M E52-CA15AF D=1 8M
Heat resistive E52-CA15AF D=1
NETU 1M
E52-CA15AF D=1
NETU 2M
E52-CA15AF D=1
NETU 4M
E52-CA15AF D=1
NETU 8M
20 Standard E52-CA20AF D=1 1M E52-CA20AF D=1 2M E52-CA20AF D=1 4M E52-CA20AF D=1 8M
Heat resistive E52-CA20AF D=1
NETU 1M
E52-CA20AF D=1
NETU 2M
E52-CA20AF D=1
NETU 4M
E52-CA20AF D=1
NETU 8M
35 Standard E52-CA35AF D=1 1M E52-CA35AF D=1 2M E52-CA35AF D=1 4M E52-CA35AF D=1 8M
Heat resistive E52-CA35AF D=1
NETU 1M
E52-CA35AF D=1
NETU 2M
E52-CA35AF D=1
NETU 4M
E52-CA35AF D=1
NETU 8M
1.6 dia. 15 Standard E52-CA15AF D=1.6
1M
E52-CA15AF D=1.6
2M
E52-CA15AF D=1.6
4M
E52-CA15AF D=1.6
8M
Heat resistive E52-CA15AF D=1.6
NETU 1M
E52-CA15AF D=1.6
NETU 2M
E52-CA15AF D=1.6
NETU 4M
E52-CA15AF D=1.6
NETU 8M
20 Standard E52-CA20AF D=1.6
1M
E52-CA20AF D=1.6
2M
E52-CA20AF D=1.6
4M
E52-CA20AF D=1.6
8M
Heat resistive E52-CA20AF D=1.6
NETU 1M
E52-CA20AF D=1.6
NETU 2M
E52-CA20AF D=1.6
NETU 4M
E52-CA20AF D=1.6
NETU 8M
35 Standard E52-CA35AF D=1.6
1M
E52-CA35AF D=1.6
2M
E52-CA35AF D=1.6
4M
E52-CA35AF D=1.6
8M
Heat resistive E52-CA35AF D=1.6
NETU 1M
E52-CA35AF D=1.6
NETU 2M
E52-CA35AF D=1.6
NETU 4M
E52-CA35AF D=1.6
NETU 8M
Exposed-lead
Models
3.2 dia. 15 Standard E52-CA15AF D=3.2
1M
E52-CA15AF D=3.2
2M
E52-CA15AF D=3.2
4M
E52-CA15AF D=3.2
8M
Heat resistive E52-CA15AF D=3.2
NETU 1M
E52-CA15AF D=3.2
NETU 2M
E52-CA15AF D=3.2
NETU 4M
E52-CA15AF D=3.2
NETU 8M
20 Standard E52-CA20AF D=3.2
1M
E52-CA20AF D=3.2
2M
E52-CA20AF D=3.2
4M
E52-CA20AF D=3.2
8M
Heat resistive E52-CA20AF D=3.2
NETU 1M
E52-CA20AF D=3.2
NETU 2M
E52-CA20AF D=3.2
NETU 4M
E52-CA20AF D=3.2
NETU 8M
35 Standard E52-CA35AF D=3.2
1M
E52-CA35AF D=3.2
2M
E52-CA35AF D=3.2
4M
E52-CA35AF D=3.2
8M
Heat resistive E52-CA35AF D=3.2
NETU 1M
E52-CA35AF D=3.2
NETU 2M
E52-CA35AF D=3.2
NETU 4M
E52-CA35AF D=3.2
NETU 8M
50 Standard E52-CA50AF D=3.2
1M
E52-CA50AF D=3.2
2M
E52-CA50AF D=3.2
4M
E52-CA50AF D=3.2
8M
Heat resistive E52-CA50AF D=3.2
NETU 1M
E52-CA50AF D=3.2
NETU 2M
E52-CA50AF D=3.2
NETU 4M
E52-CA50AF D=3.2
NETU 8M
4.8 dia. 20 Standard E52-CA20AF D=4.8
1M
E52-CA20AF D=4.8
2M
E52-CA20AF D=4.8
4M
E52-CA20AF D=4.8
8M
Heat resistive E52-CA20AF D=4.8
NETU 1M
E52-CA20AF D=4.8
NETU 2M
E52-CA20AF D=4.8
NETU 4M
E52-CA20AF D=4.8
NETU 8M
35 Standard E52-CA35AF D=4.8
1M
E52-CA35AF D=4.8
2M
E52-CA35AF D=4.8
4M
E52-CA35AF D=4.8
8M
Heat resistive E52-CA35AF D=4.8
NETU 1M
E52-CA35AF D=4.8
NETU 2M
E52-CA35AF D=4.8
NETU 4M
E52-CA35AF D=4.8
NETU 8M
50 Standard E52-CA50AF D=4.8
1M
E52-CA50AF D=4.8
2M
E52-CA50AF D=4.8
4M
E52-CA50AF D=4.8
8M
Heat resistive E52-CA50AF D=4.8
NETU 1M
E52-CA50AF D=4.8
NETU 2M
E52-CA50AF D=4.8
NETU 4M
E52-CA50AF D=4.8
NETU 8M
37
E52 (Ferrule)
Low-cost Models (with Ferrule)
Low-cost Platinum Resistance Thermometers
Exposed-lead Models with Screws
Exposed-lead Models with Flange
Exposed-lead Models
Specifications
Element type Pt100
Conductor type 3-conductor system
Class Class B
Protective tubing
material
SUS304
Sensor length 30 mm
Max. detectable
temperature
250°C
Temperature
range
50°C to 250°C
Lead wire Fluororesin-covered
wire (PFA) and
approx. 1.0 dia.
7/0.18
50°C to 150°C
E52-P6DF
Dimensions
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m) Model
1 E52-P6DF 1M
2 E52-P6DF 2M
4 E52-P6DF 4M
Lead wire
4 dia.±0.4
(16)
Silicon
shrinkable tube
65
10±0.5
6
±
0.5
15
(30) (M-16)
0
-2
Red (A)
Black (B)
White (B)
M±5%
Product label
Ferrule *
A
B
B
Maker tube
14
Full-circled welding
Yellow
SUS304
protective
tubing
Tapered pipe thread
SUS304
R1/8
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
Specifications
Element wire Pt100
Conductor type 3-conductor system
Class Class B
Protective tubing
material
SUS304
Sensor length 30 mm
Max. detectable
temperature
250°C
Temperature
range
50°C to 250°C
Lead wire Fluororesin-covered
wire (PFA) and
approx. 1.0 dia.
7/0.18
50°C to 150°C
E52-P6FF
Dimensions
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m) Model
1 E52-P6FF 1M
2 E52-P6FF 2M
4 E52-P6FF 4M
Flange (SUS304)
SUS304 protective
tubing
Silicon
shrinkable tube
Three, 3.5 dia.
20 dia.
30 dia.
Red (A)
Black (B)
White (B)
Ferrule *
Maker tube
Lead wire
Nickel soldering
(M-16)
(30)
A
B
B
4 dia.±0.4
Product label
65 15
0
-2 M±5%
Yellow
120°120°
1
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
Specifications
Element type Pt100
Conductor type 3-conductor system
Class Class B
Protective tubing
material
SUS316
Max. detectable
temperature
250°C
Temperature
range
0°C to 250°C
Lead wire Fluororesin-covered
wire (PFA) and
approx. 1.0 dia.
7/0.2
50°C to 150°C
E52-P10AEF
Dimensions
Note: 1. The protective tubing is of pipe construction, which must not be bent.
2. A Compression Fitting (PT@) cannot be used for mounting.
Lead wire length (m) Model
1 E52-P10AEF 1M
2 E52-P10AEF 2M
4 E52-P10AEF 4M
B
A
B
Lead wire
Silicon
shrinkable tube
Shrinkable tube (black)
3.2±0.05 dia.
100±3%
Product label
Red (A)
White (B)
White (B)
SUS316 protective
tubing
Ferrule *
Maker tube
M±4%
30 30±5 80±10
Yellow
* Ferrule Dimensions
Cross-sectional diameter: 1.5 mm max.
Length: 9 mm max.
E52 (Ferrule)
38
Low-cost Thermocouples
Exposed-lead Models with Screw
Protective tubing length (mm) Lead wire length (m) Element type: K (CA)
Model
M6 screw 1 E52-CA1DF M6 1M
2 E52-CA1DF M6 2M
4 E52-CA1DF M6 4M
M8 screw 1 E52-CA1DF M8 1M
2 E52-CA1DF M8 2M
4 E52-CA1DF M8 4M
W1/4 screw 1 E52-CA1DF W1/4 1M
2 E52-CA1DF W1/4 2M
4 E52-CA1DF W1/4 4M
End Workpiece
Brass
0.65-dia.
black wire
Movable ring
Cut after silver
soldering
M6
Screw
Closely wound
enamel-bonded coil.
Brass pipe
Shielded
glass-wool lead
wire
Red (+)
Black ()
M±1%
3.8±0.1
5±0.05 dia.
9±1
A±0.3
1±0.1 3.8±1
Ferrule *
Maker tube
Turquoise
80±10
10 0
-0.5
2.8 0
+0.3
(70)
(20)
C
B
120°
Lead wire
Movable ring (brass)
Top ring (brass)
+
-
Shrinkable tube
(CA: Blue,
IC: Yellow)
Protective
copper wire
SUS304
screw
Sleeve
(
Brass-nickel plating
)
Specifications
Note: 1. The thermocouple is a single wire from
the tip to the terminal.
2. Specify the type of screw (i.e., M6, M8,
or W1/4) when ordering.
3. The thermocouple is not of airtight
construction.
4. OMRON recommends that the tip of
the thermocouple is touching the
sensing object.
Installation Example
Cut a thread into the workpiece, and screw in the
thermocouple while pushing in so that the tip
makes complete contact.
Element type K (CA)
Element dia. 0.65 mm (single wire)
Class Class 2 (0.75)
Protective tubing
material
SUS304
Thermal contact Grounded type
Temperature range 0°C to 400°C: K (CA)
Lead wire Fully glass-wool-
covered with external
copper shield and
external dimensions of
approx. 3.1 x 2.0
1/0.65
0°C to 180°C
Terminal shape Ferrule
E52-CA1DF
Dimensions
Lead wire
length (m)
Screw
W1/4
(P=1.27)
M6
(P=1.0)
M8
(P=1.25)
A (mm) 4.3 4 5.3
B (mm) 11.5 11.5 15
C (mm) 10 10 13
Note: E52-CA1DF with the same shape and multiple element wires are also available (E52-CA1DF-40).
Refer to page 42 for details.
Internal Construction (E52-CA1DF)
* Ferrule Dimensions
Cross-sectional diameter: 1.5 mm max.
Length: 9 mm max.
39
E52 (Ferrule)
Exclusive Models (with Ferrule)
Thermocouples
Thermocouples for Molding Machines
Thermocouples with Crimp Terminals
Platinum Resistance Thermometers
Platinum Resistance Thermometers for Surface Temperature Measurement
15 dia.
Marker
tube
White/red stripe (+)
Lead wire
Shrinkable tube
(Blue)
Product label Ferrule *
White
(80)
85±10
M±5%
SUS304
protective
tubing
Spring
Spring retainer
(Brass-nickel plating
)
Bayonet
(Brass-nickel plating
)
25±2
10
10
15
100±10
4.8±0.05 dia.
5 dia.
12 dia.8 dia.
R1
/
8
6.8
dia.
15
20 (30)
+
CA: White/blue stripe
IC: White/yellow stripe
()
Specifications
Element type K (CA)
Element
diameter
1.0 mm (single wire)
Class Class 2 (0.75)
Protective
tubing material
SUS304
Thermal contact Grounded type
Temperature
range
0°C to 350°C
Lead wire
Glass-covered stainless
steel shielded thermocouple
wire with 4 dia.
1/1.0
0°C to 180°C
E52-CA2GVF
Dimensions
Lead wire
length (m)
Element type: K (CA)
Model
1 E52-CA2GVF 1M
2 E52-CA2GVF 2M
Note: The Adapter is included with
the Thermocouple.
If it is lost or damaged, you
can order a replacement with
the following model number.
Adapter: Y92F-S1
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
Specifications
Note: The E52-CA1GTF is also available with
double elements. Refer to page 42 for
details.
Element type K (CA)
Element
diameter
0.65 mm (single wire)
Class Class 2 (0.75)
Thermal contact Grounded type
Temperature
range
0°C to 300°C
Lead wire
Glass-wool-braided shield
with maximum external
dimensions of 2.6 x 4.0
1/0.65
0°C to 150°C
Terminal shape Ferrule
E52-CA1GTF
Dimensions
Lead wire
length (m)
Element type: K (CA)
Model
1 E52-CA1GTF 1M
2 E52-CA1GTF 2M
Ferrule *
Marker tube
Turquoise
M±4%
90±10
30±5
15±5
Shrinkable tube
(Blue)
Silicone
shrinkable tubing
Lead wire
Product label
(80)
M4, round crimp terminal
(N1.25-4)
4.3 dia.
6.6
6 dia. max.
White/red stripe (+)
White stripe ()
+
Sensing point
* Ferrule Dimensions
Cross-sectional diameter: 1.5 mm max.
Length: 9 mm max.
Specifications
Element type Pt100
Class Class B
Protective
tubing material
SUS304
With brass-nickel-
plated bracket
Conductor type 3-conductor system
Temperature
range
50°C to 250°C
Lead wire Silicone-covered
3-conductor cable
and approx. 3.9 dia.
30/0.08
50°C to 150°C
E52-P2GSF
Dimensions
Lead wire length (m) Model
1 E52-P2GSF 1M
2 E52-P2GSF 2M
(80)
M±4% 90±10
30±5
28±1
1.5 4.50
6
3
5
Lead wire
20±1
14±0.5
(7.5-dia.)
20±0.5
(30)
(50)
Ferrule *
Yellow
Shrinkable tube
(Black)
Brass-nickel-plated bracket
Four, 3.2 dia.
Silicon
shrinkable tube Product label
Red (A)
White (B)
White (B)
Marker tube
A
B
B
* Ferrule Dimensions
Cross-sectional diameter: 1.5 mm max.
Length: 9 mm max.
E52 (Ferrule)
40
Platinum Resistance Thermometers for Room Temperature Measurement
Waterproof Platinum Resistance Thermometers
69.5±1
85
85±10
22.2±1 dia.
Protective pipe (Brass-nickel plating)
4.8 dia.
8.0 dia.
SUS304 protective
tubing
Terminal box
Marker tube
Red (A)
White (B)
Black (B)
70±1 dia.
100±4 97±1 M±5%
(95)
Two
,
8
dia.
(30) (80)
A
B
B
56±1
42±160
4.5±1
Lead wire
Chain Ferrule *
Shrinkable tube
(Black)
White
Product label
Specifications
Element type Pt100
Class Class B
Protective tubing
material
SUS304
Conductor type 3-conductor system
Temperature range 50°C to 60°C
Lead wire
Vinyl-covered
3-conductor cable with
6.1 dia.
20/0.18
20°C to 60°C
E52-P10GRF
Dimensions
Lead wire length (m) Model
2 E52-P10GRF 2M
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
85±10
7±0.2 dia.
100±10 62
12
5
Red (A)
White (B)
Black (B)
M±5%
A
B
B
Marker tube
Full-circled welding Ferrule *
White
Product label
Lead wire
Shrinkable tube
(Black)
Sleeve
(SUS304)
20 dia.
(30) (80)
SUS304
protective tubing
Specifications
Element wire Pt100
Class Class B
Protective tubing
material
SUS304
Conductor type 3-conductor system
Temperature range 0°C to 70°C (underwater)
20°C to 70°C (in the air)
Lead wire Vinyl-covered 3-conductor
cable with 6.1 dia.
12/0.18
25°C to 60°C
Resistive pressure 10 kg/cm2 max.
E52-P10GPF
Dimensions
Note: The lead wires are vinyl-covered, and cannot be used underwater.
Use the E52-P5AF-40 if waterproof lead wires are required for use underwater.
Refer to page 41 for details.
Lead wire length (m) Model
2 E52-P10GPF 2M
4 E52-P10GPF 4M
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
41
E52 (Ferrule)
Corrosion-resistant Models with Fluororesin-covered
Protective Tubing (with Ferrule)
FEP-molded Models (Completely Waterproof)
90±10
Product label
Lead wire
FEP-covered tubing
M±4%
30±5 (80)
Ferrule *
White
Shrinkable tube
(Black)
Fused (completely waterproof)
65 +4
1
6 dia.
+0.1
0.5 A
B
B
Red (A)
White (B)
White (B)
Marker tube
E52-P5AF-40
Dimensions
Model Lead wire length (m)
E52-P5AF-40 2M 2
E52-P5AF-40 4M 4
Specifications
Element type Pt100
Class Class B
Protective tubing
material
Fluororesin (FEP) tube
(element / fluororesin
mold (FEP))
Conductor type 3-conductor system
Temperature range 50°C to 180°C
Lead wire
Fluororesin (FEP)
cover (with outer
cover)
: 50°C to 180°C
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
E52 (Ferrule)
42
Silicone-covered Lead Wires Models (with Ferrule)
Thermocouples
Exposed-lead Models with Screws
Specifications
Note: Refer to the installation example for the E52-CA1DY.
E52-CA1DF-40
Dimensions
Thermocouples with Crimp Terminals
Specifications
E52-CA1GTF-14
Dimensions
Lead wire length (M): 1 or 2 m
Element type K (CA)
Class Class 2 (0.75)
Screw material SUS304
Thermal contact Grounded type
Temperature range 0°C to 300°C
Lead wire Silicone-covered (0.1/30): 0°C to
150°C
Terminal shape Ferrule
Element type K (CA)
Class Class 2 (0.75)
Thermal contact Grounded type
Temperature range 0°C to 200°C
Lead wire Silicone-covered : 0°C to 150°C
Terminal shape Ferrule
Red (+)
White ()
Lead wire
Ferrule *
Maker tube
Yellow
80±10
(70)
(20)
M±1%
3.8±0.1
120°
1±0.1
10 0
0.5
2.8 0
+0.3
A±0.3
Shrinkable tube (Blue)
Protective spring
(SUS304)
8±0.05
dia.
0.6 dia.
6.5 dia.
+0.05
0
13±1 80±5
Movable ring (brass)
Top ring (Brass)
+
SUS304
screw
Sleeve
(Brass-nickel plating)
Model Screw
pitch
Lead wire
length (m)
E52-CA1DF-40 M6 1M M6 (P=1.0) 1
E52-CA1DF-40 M6 2M M6 (P=1.0) 2
E52-CA1DF-40 M6 4M M6 (P=1.0) 4
* Ferrule Dimensions
Cross-sectional diameter: 1.5 mm max.
Length: 9 mm max.
Lead wire
Product label
Shrinkable tube (Blue)
Silicone
shrinkable tubing Red (+)
White ()
Ferrule *
Maker tube Yellow
M±4%
15±5 (80)
90±10
30±5
M4, round,
crimp terminal
(N1.25-4)
4.3 dia.
7 dia. max.
6.6
+
Sensing point
Model Lead wire length (m)
E52-CA1GTF-14 1M 1
E52-CA1GTF-14 2M 2
* Ferrule Dimensions
Cross-sectional diameter: 1.5 mm max.
Length: 9 mm max.
43
E52 (Ferrule)
Accessories
Compression Fittings
Model Information
Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the
sensing object will cause problems.
The compression fitting is a screw that adjusts and secures the insertion
length of Temperature Sensors with the above protective tubing diameters.
The material of the Compression Fitting is SUS304 with internal fixing beads
made of brass.
Source: JIS B 0203 (Unit: mm)
Loose Flanges
Model Information
Note: 1. Use the Loose Flange in atmospheric pressure. The Loose
Flange is not of airtight construction.
2. Use the Loose Flange at 400°C maximum.
3. Do not apply the Loose Flange to protective tubing
diameters other than the applicable ones.
Material: Aluminum
Model Screw of part
a
Applicable
protective tubing
diameter
Dimension
b c d Flat diameter
Part c Part b
PT 1/8 D=1.0 R 1/8 1.0 dia. 5 13 10 14 14
PT 1/8 D=1.6 1.6 dia.
PT 1/8 D=3.2 3.2 dia.
PT 1/8 D=4.8 4.8 dia.
PT 1/4 D=3.2 R 1/4 3.2 dia. 5 15 12 17 14
PT 1/4 D=4.8 4.8 dia.
PT 1/4 D=6.4 6.4 dia.
PT 3/8 D=8 R 3/8 8 dia. 5 19 15 21 17
PT 1/2 D=10 R 1/2 10 dia. 15.1 8 19 22 19
M 12 D=4.8 M 12 4.8 dia. 5 15 12 17 14
Sensor side
Protective tubing dia.
Head side
a
bcd
D
Main body Retaining screw
SUS304
Material SUS304
Lock bead
Brass
Tighten using the retaining screw to
secure to the protective tubing.
Main body
SUS316
Front ring
SUS316
Back ring
SUS316
Nut
SUS316
<R1/8, 1/4, R3/8>
<1/2>
Nomi-
nal
thread
size
T.P.I.
(No. of
threads
/inch)
Outer
diame-
ter: d
Effec-
tive
diame-
ter: d2
Root
diame-
ter: d1
Stan-
dard
diame-
ter
posi-
tion a
(from
pipe
end)
Mini-
mum
effec-
tive
screw
length:
f
R 1/8 28 9.728 9.147 8.566 3.97
±0.91
2.5
R 1/4 19 13.157 12.301 11.445 6.01
±1.34
3.7
R 3/8 19 16.662 15.806 14.950 6.35
±1.34
3.7
R 1/2 14 20.955 19.793 18.631 8.16
±1.81
5.0
d1
d2
d
af
Tapered thread
Standard dia.
Applicable protective
tubing diameter
Model
3.2 dia. MF-1 D=3.2
4.8 dia. MF-1 D=4.8
6.4 dia. MF-1 D=6.4
8 dia. MF-1 D=8
10 dia. MF-2 D=10
12 dia. MF-2 D=12
15 dia. MF-2 D=15
22 dia. MF-2 D=22
120°
Three, 5 dia.
21 dia.
D dia.
23 dia.
36
45 dia.
514
M4
Three, 6.5 dia.
54 dia.
31 dia.
D dia.
35 dia.
70 dia.
24
6.6
M6
120°
MF-2MF-1
E52 (Ferrule)
44
Compensating Conductors
The material of the Compensating Conductor is the same as or similar to that of the Thermocouple. Therefore, the Thermocouple can be connected
to the Compensating Conductor just as if the length of the Thermocouple is to be extended. A standard model for a temperature range between
20°C and 70°C and two types of heat-resistive models for a temperature range between 0°C and 150°C are available.
Be sure to use the compensating conductor for the extension of the length of the thermocouple.
Model Information
Note: 1. Compensating Conductors with lengths, increased in units of a meter, up to 100 meters are available on request. Specify lengths above
100 meters in units of 100 meters. The maximum length depends on the product. Contact your OMRON representative for details.
2. It has the same waterproof characteristics as the standard model (fully vinyl-covered) and can be used at high temperatures.
Specifications (JIS C1610-1995)
Note: Symbols conform to JIS standards.
For code having duplicate exterior, check the application and check in our models.
Thermocouple Heat
resistance
Exterior Model
(Length) 1 m 2 m 4 m 8 m
R Standard Fully vinyl-covered (waterproof) WPRG-N 1M WPRG-N 2M WPRG-N 4M WPRG-N 8M
Heat resistive Fully glass-wool-covered WPRH-N 1M WPRH-N 2M WPRH-N 4M WPRH-N 8M
Fully glass-wool-covered with external shield
of stainless steel
WPRH6-N 1M WPRH6-N 2M WPRH6-N 4M WPRH6-N 8M
K (CA) Standard Fully vinyl-covered (waterproof) WCAG-N 1M WCAG-N 2M WCAG-N 4M WCAG-N 8M
Heat resistive Fully glass-wool-covered WCAH-N 1M WCAH-N 2M WCAH-N 4M WCAH-N 8M
Fully glass-wool-covered with external shield
of stainless steel
WCAH6-N 1M WCAH6-N 2M WCAH6-N 4M WCAH6-N 8M
Silicone-covered (See note 2.) WCAG-40 1M WCAG-40 2M WCAG-40 4M WCAG-40 8M
J (IC) Standard Vinyl covered (waterproof) WICG-N 1M WICG-N 2M WICG-N 4M WICG-N 8M
Heat resistive Fully glass-wool-covered WICH-N 1M WICH-N 2M WICH-N 4M WICH-N 8M
Fully glass-wool-covered with external shield
of stainless steel
WICH6-N 1M WICH6-N 2M WICH6-N 4M WICH6-N 8M
Model Type of
thermo-
couple
Use Code
(See note.)
Exterior Number of
wires/wire
diameter
Operating
temperature
range (°C)
Error (°C) Exterior
color
WPRG-N R Standard RCA-2-G Fully vinyl-covered (waterproof) 7/0.3 0 to 90 ±30 Black
WPRH-N Heat resistive RCB-2-H Fully glass-wool-covered 7/0.32 0 to 150 ±60
WPRH6-N Fully glass-wool-covered with
external shield of stainless steel
WCAG-N K (CA) Standard KCC-2-G Fully vinyl-covered (waterproof) 7/0.3 0 to 90 ±100 Blue
WCAH-N Heat resistive KCB-2-H Fully glass-wool-covered 7/0.32 0 to 150
WCAH6-N Fully glass-wool-covered with
external shield of stainless steel
WCAG-40 Heat resistive
for moving parts
KX-2-G Silicone-covered 30/0.1 20 to 150 ±100
WICG-N J (IC) Standard JX-2-G Fully vinyl-covered (waterproof) 7/0.3 20 to 90 ±140 Yellow
WICH-N Heat resistive JX-2-H Fully glass-wool-covered 7/0.32 0 to 150
WICH6-N Fully glass-wool-covered with
external shield of stainless steel
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omrons test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016
.
8
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/