www.clare.com
2R01
LCB710
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
AC/DC Configuration, Continuous IF=0mA IL
--1
A
DC Configuration, Continuous - - 2
Peak IF=0mA , t < 10ms ILPK --5
On-Resistance 1
IF=0mA, IL=1A - 0.39 0.6 AC/DC Configuration RON Ω
DC Configuration IF=0mA, IL=2A - 0.1 0.2
Switching Speeds
Turn-On ton - 0.63 3
IF=5mA, VL=10V ms
Turn-Off toff - 1.5 3
Off-State Leakage Current IF=2mA, VL=60V ILEAK --1μA
Output Capacitance IF=2mA, VL=50V, f=1MHz COUT - 125 - pF
Input Characteristics
Input Control Current IL=1A IF- 0.22 2 mA
Input Dropout Current - IF0.1 0.21 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10μA
Common Characteristics
Capacitance, Input to Output - CI/O -3-pF
1 Measurement taken within 1 second of on-time.
Parameter Ratings Units
Blocking Voltage 60 VP
Reverse Input Voltage 5 V
Input Control Current
Peak (10ms)
50 mA
1A
Input Power Dissipation 1100 mW
Total Power Dissipation 2800 mW
Isolation Voltage, Input to Output 3750 Vrms
ESD Rating, Human Body Model 8 kV
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Absolute Maximum Ratings @ 25ºC