www.clare.com
2R05
CPC1916
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Ratings Units
Blocking Voltage 100 VP
Reverse Input Voltage 5 V
Input control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Isolation Voltage, Input to Output 2500 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 3.33 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current, Continuous Free air IL- - 2.5 ADC/Arms
Peak Load Current t < 10ms ILPK --6
AP
On-Resistance 1IL=1A RON - - 0.34 Ω
Off-State Leakage Current VL=100VPILEAK --1µA
Switching Speeds
Turn-On IF=10mA, VL=10V ton --5
ms
Turn-Off toff --3
Input Characteristics
Input Control Current IL=1A IF- 3.3 10 mA
Input Dropout Current - IF0.3 - - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics
Capacitance, Input/Output - - - 2 - pF
1 Measurement taken within 1 second of on-time.
Electrical Characteristics @ 25ºC
Parameter Conditions Symbol Min Typ Max Units
Thermal Resistance (junction to case) - RθJC - 1.5 - °C/W
Thermal Characteristics