JS
3
ds_61B05_en_js: 010611D
RATING
1. Coil data
Note: * When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with
20C 68F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.
2. Specifications
Notes:
*1.This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2.The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
*3.When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with 20C
68F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.
Nominal coil
voltage Pick-up voltage
(at 20C 68F)Drop-out voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
(at 20C 68F)
Max. applied voltage
(at 70C 158F)
5V DC
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
72 mA 69.4
360mW
130%V of
nominal voltage
[When using relays at
85C 185F, see Note*]
6V DC 60 mA 100
9V DC 40 mA 225
12V DC 30 mA 400
18V DC 20 mA 900
24V DC 15 mA 1,600
48V DC 7.5mA 6,400
Characteristics Item Specifications
Contact Contact material AgSnO2 type
Contact resistance (Initial) Max. 100 m (By voltage drop 6 V DC 1A)
Arrangement 1 Form A, 1 Form C 1 Form A Long endurance type
Rating
Nominal switching capacity (resistive load) 10 A 250 V AC (NO), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC 10 A 250 V AC, 10 A 277 V AC, 5 A 30 V DC
Max. switching power (resistive load) 2,500VA 150W (NO), 1,662VA 150W (NC) 2,770VA 150W
Max. switching voltage 250V AC, 100V DC (0.5A)
Max. switching current 10A (AC), 5A (DC)
Nominal operating power 360mW
Min. switching capacity*1100mA, 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 100M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial) Between open contacts 750 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 1,500 Vrms for 1 min. (Detection current: 10 mA)
Temperature rise (coil) Max. 35C 95F (By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 10A, at 70C 158F)
Operate time (at nominal voltage) (at 20C 68F) Max. 10 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20C 68F) Max. 10 ms (excluding contact bounce time) (Without diode)
Mechanical
characteristics
Shock resistance Functional 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 2 mm
Expected life
Mechanical (at 180 times/min.) Min. 107
Electrical (resistive load)
1105
[10A 125V AC, 6A 277V AC, 5A 30V DC]
5104 (NO contact only)
[10A 250V AC]
2105
[10A 277V AC]
1.5105
[10A 250V AC (at 20 times/min., 105C 221F)]
1105
[5A 30V DC]
Conditions Conditions for operation, transport and storage*2
–40C to +70C –40F to +158F
(Class E insulation)
–40C to +85C –40F to +185F
(Class B insulation)*3
–40C to +105C –40F to +221F
(Class F insulation)*3
Humidity: 5 to 85% R.H. (Not freezing and
condensing at low temperature)
–40C to +105C –40F to +221F*3;
Humidity: 5 to 85% R.H. (Not freezing and
condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 12 g .423 oz