2007-04-19
1
BAT60B...
Silicon Schottky Diode
High current rectifier Schottky diode with
very low VF drop (typ. 0.24 V at IF = 10mA)
For power supply applications
For clamping and protection in
low voltage applications
For detection and step-up-conversion
Pb-free (RoHS compliant) package1)
Qualified according AEC Q101
BAT60B
ESD (Electrostatic discharge) sensitive device, observe handling precaution!
Type Package Configuration Marking
BAT60B SOD323 single white/5
Maximum Ratings at T
A
= 25°C, unless otherwise specified
Parameter Symbol Value Unit
Diode reverse voltage2) VR10 V
Forward current IF3 A
Non-repetitive peak surge forward current
(t 10ms) IFSM 5
Total power dissipation
TS 28°C Ptot 1350 mW
Junction temperature T
j
150 °C
Operating temperature range To
p
-55 ... 125
Storage temperature Tst
g
-55 ... 150
1Pb-containing package may be available upon special request
2For TA > 25 °C the derating of VR has to be considered. Please refer to curve Permissible reverse voltage.
2007-04-19
2
BAT60B...
Thermal Resistance
Parameter Symbol Value Unit
Junction - soldering point1) RthJS 90 K/W
Electrical Characteristics at T
A
= 25°C, unless otherwise specified
Parameter Symbol Values Unit
min. typ. max.
DC Characteristics
Reverse current2)
VR = 5 V
VR = 8 V
VR = 5 V, TA = 80 °C
VR = 8 V, TA = 80 °C
IR
-
-
-
-
5
10
100
410
15
25
800
1500
µA
Forward voltage2)
IF = 10 mA
IF = 100 mA
IF = 500 mA
IF = 1000 mA
VF
0.2
0.26
0.32
0.36
0.24
0.32
0.4
0.48
0.3
0.38
0.5
0.6
V
AC Characteristics
Diode capacitance
VR = 5 V, f = 1 MHz CT12 25 30 pF
1For calculation of RthJA please refer to Application Note Thermal Resistance
2Pulsed test: tp = 300 µs; D = 0.01
2007-04-19
3
BAT60B...
Reverse current IR = ƒ(VR)
TA = Parameter
02468V12
VR
-10
10
-9
10
-8
10
-7
10
-6
10
-5
10
-4
10
-3
10
-2
10
A
IR
25°C
-40°C
85°C
125°C
Forward current IF = ƒ (VF)
TA = Parameter
0 0.1 0.2 0.3 0.4 0.5 0.6 V0.8
VF
-5
10
-4
10
-3
10
-2
10
-1
10
0
10
A
IF
-40°C
25°C
85°C
125°C
Permissible Reverse voltage VR = ƒ (TA)
tp = Parameter; duty cycle < 0.01
Device mounted on PCB with Rth = 160 K/W
0 20 40 60 80 100 120 °C 150
TA
0
1
2
3
4
5
6
7
8
9
10
V
12
VR
300µs
100ms
DC
Forward current IF = ƒ (TS)
0 15 30 45 60 75 90 105 120 °C 150
TS
0
500
1000
1500
2000
2500
mA
3500
IF
2007-04-19
4
BAT60B...
Permissible Puls Load RthJS = ƒ (tp)
10 -6 10 -5 10 -4 10 -3 10 -2 10 0
s
tp
-1
10
0
10
1
10
2
10
K/W
RthJS
0.5
0.2
0.1
0.05
0.02
0.01
0.005
D = 0
Permissible Pulse Load
IFmax/ IFDC = ƒ (tp)
10 -6 10 -5 10 -4 10 -3 10 -2 10 0
s
tp
0
10
1
10
2
10
-
IFmax/IFDC
D = 0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
2007-04-19
5
BAT60B...
Package SOD323
Package Outline
Foot Print
Marking Layout (Example)
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel
Reel ø330 mm = 10.000 Pieces/Reel
BAR63-03W
Type code
Cathode marking
Laser marking
0.80.8
0.6
1.7
marking
Cathode
±0.2
2.5
0.25
0.3
1
-0.05
M
A
+0.1
+0.2
2
1.25
-0.1
+0.05
-0.2
1.7
0.3
0.15
-0.06
+0.1
0
±0.05
+0.2
-0.1
A
0.9
+0.2
-0.1
±0.15
0.45
0.2
4
8
2.9
1
2
1.35
0.65
Cathode
marking
2007-04-19
6
BAT60B...
Edition 2006-02-01
Published by
Infineon Technologies AG
81726 München, Germany
© Infineon Technologies AG 2007.
All Rights Reserved.
Attention please!
The information given in this dokument shall in no event be regarded as a guarantee
of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any
examples or hints given herein, any typical values stated herein and/or any information
regarding the application of the device, Infineon Technologies hereby disclaims any
and all warranties and liabilities of any kind, including without limitation warranties of
non-infringement of intellectual property rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices
please contact your nearest Infineon Technologies Office (www.infineon.com).
Warnings
Due to technical requirements components may contain dangerous substances.
For information on the types in question please contact your nearest
Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or
systems with the express written approval of Infineon Technologies, if a failure of
such components can reasonably be expected to cause the failure of that
life-support device or system, or to affect the safety or effectiveness of that
device or system.
Life support devices or systems are intended to be implanted in the human body,
or to support and/or maintain and sustain and/or protect human life. If they fail,
it is reasonable to assume that the health of the user or other persons
may be endangered.