1
Features ––––––––––––––––––––––––
• Both crimp style and insulation displacement
receptacles can be used
Both crimp style and insulation displacement HR connector
receptacles can be accommodated by the THR connector.
• Arm lock mechanism
An arm lock mechanism securely holds the plug and the
receptacle together when they are connected. Releasing the
lock is easy.
• Mountable on a variety of panels
Due to our unique panel installation locking mechanisms, the
housing can be easily installed on panels of various thickness
without using tools.
Specifications –––––––––––––––––––
• Current rating:
Crimp style HR connectors type/3A AC, DC max.
Insulation displacement HR connectors type/2A AC, DC max.
• Voltage rating: 250V AC, DC max.
• Temperature range: -25˚C to +85˚C
(including temperature rise in applying
electrical current)
• Contact resistance: Initial value/15m max.
After environmental testing/25m max.
• Insulation resistance: 500M min.
• Withstanding voltage: 1,000V AC/minute
• Applicable wire:
Crimp style HR connectors type/AWG #26 to #22
0.13 to 0.33mm2
Insulation displacement HR connectors type/AWG #28, #26, #24
• Applicable panel thickness: 0.5 to 2.0mm
*Compliant with RoHS.
*Refer to "General Instruction and Notice when using
Terminals and Connectors" at the end of this catalog.
* Contact JST for details.
THR CONNECTOR
Wire-to-wire connectors - Matable with HR receptacles
Crimp
2.5mm
pitch
2
THR CONNECTOR
THR Connector –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
HJST
6
B
A
7.8
4.0
22.7
10.4
2.5
2.95
2.5
6.0
B
A
11.6
(10.8) (23.1)
(10.4)
Housing: PA 66, UL94V-0
Post: Copper alloy, copper-undercoated, tin-plated (reflow treatment)
Circuits Dimensions (mm)Model No.
A
Q´ty /
bag
B1-N type 1-1 type
3
6
12
BU03P-THR
BU06P-THR
BU12P-THR
BU03P-THR-1-K
BU06P-THR-1-K
BU12P-THR-1-K
5.0
12.5
27.5
200
100
50
11.6
19.1
34.1
Material and Finish
Receptacle / Insulation displacement HR connector ––––––––––––––––––––––––––––
A
B
4.1
10.3
3.6
2.5
2.5
Contact: Phosphor bronze, tin-plated (reflow treatment)
Housing: PA 66, UL94V-0
Circuits Model No. Dimensions (mm)
A
Q´ty /
box
B
3
6
12
03HR-8M-P-N
06HR-8M-P-N
12HR-8M-P-N
5.0
12.5
27.5
1,000
1,000
500
10.0
17.5
32.5
Material and Finish
03HR-6S-P-N
06HR-6S-P-N
12HR-6S-P-N
03HR-4K-P-N
06HR-4K-P-N
12HR-4K-P-N
#28 #26 #24
Receptacle
Housing
1-N type
1-1 type
RoHS compliance This product displays (LF)(SN) on a label.
RoHS compliance
3
THR CONNECTOR
Circuits Housing
3
6
12
BU03P-THR
BU06P-THR
BU12P-THR
0.5 to 2.0
15.3
22.8
37.8
Panel hole dimensions (mm)
General tolerance
C[±0.05]
Applicable Panel
thickness (mm)
Circuits Housing
C[±0.05] D[ ]
+0.1
0
3
6
12
BU03P-THR-1-K
BU06P-THR-1-K
BU12P-THR-1-K
0.5 to 2.0
15.3
22.8
37.8
11.8
19.3
34.3
Panel hole dimensions (mm)
General tolerance
Applicable Panel
thickness (mm)
Panel layout and Assembly layout –––––––––––––––––––––––––––––––––––––––––––
C
12.0+0.1
0
6.5±0.05
7.8
+0.1
0
22.7
7.5
1.1
D
D
C
6.2±0.05
8.3+0.1
0
11.8+0.1
0
10.3+0.1
0
23.1
10.1
Receptacle / Crimp style HR connector –––––––––––––––––––––––––––––––––––––––
8.2
1.9
2.1
4.85
2.85
1.3
Phosphor bronze, tin-plated (reflow treatment)
Model No.
Applicable wire Q´ty /
reel
Insulation O.D.
(mm)
SHR-001T-P0.6 26 to 22 9,000
1.3 to 1.7
Material and Finish
mm AWG #
2
0.13 to 0.33
10.3 4.1
A
B
2.5
2.5
PA 66, UL94V-0
Circuits Model No. Dimensions (mm)
A
Q´ty /
bag
B
3
6
12
HRP-03-S
HRP-06-S
HRP-12-S
5.0
12.5
27.5
2,000
1,000
500
10.0
17.5
32.5
Material
Housing
Contact
1-N type
1-1 type
1-N type 1-1 type
Note: 1. Punch holes in the panel according to the sketch and table shown above. Burrs must be removed.
2. The strength of the panel must be considered when punching two or more holes.
3. The connector must be inserted from the same side as the hole is punched.
RoHS compliance
RoHS compliance
Contact
Crimping
machine
Crimp applicator Dies Crimp applicator
with dies
Crimping machine, Applicator–––––––––––––––––––––––––––––––––––––––––––––––
SHR-001T-P0.6 AP-K2N MKS-L
*MKS-SC
MK/SHR/MR-001-06
SC/SHR/MR-001-06
APLMK SHR/MR001-06
APLSC SHR/MR001-06
Note: *Strip-crimp applicator