SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
20 ~ 90% RH non-condensing
-30 ~ +70℃(Refer to "Derating Curve")
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
SAFETY STANDARDS
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
PROTECTION
Protection type : Shut off o/p voltage, clamping by zener diode
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
LEAKAGE CURRENT
< 0.25mA/277VAC
SETUP, RISE TIME
LEAD TEMPERATURE 260 5 ,5s (max.)±℃
OPERATING ALTITUDE Note.4 2000 meters
IEC62368-1, UL62368-1, TUV EN62368-1, EAC TP TC 004, -1 approvedBSMI CNS14336
EN55035, EN61000-6-2
EMC IMMUNITY
EMC EMISSION
Parameter
Conducted
Radiated
Harmonic Current (Note 5)
Voltage Flicker
Standard
EN55032(CISPR32), CNS13438
EN61000-3-2
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Radiated Susceptibility
EFT/Burest
Surge
Standard
EN61000-4-2
Test Level /Note
Level 3, 8KV air; Level 2, 4KV contact, criteria A
Level 4,2KV/L-N, criteria A
Conducted
Magnetic Field
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11
Voltage Dips and interruptions
Level 3, criteria A
Level 3, criteria A
Level 3, criteria A
Level 4, criteria A
EN55032(CISPR32), CNS13438
>.95% dip 0 5 periods, 30% dip 25 periods,
95% interruptions 250 periods>
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
5. The power supply is considered as an independent unit ,but the final equipment still need to re-confirm that the whole system complies with the EMC
directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
EMC
(Note.5)
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
File Name:IRM-20-SPEC 2019-08-30
1000ms, 20ms/230VAC 1000ms, 20ms/115VAC at full load
47 ~ 440Hz
970.3Khrs min. MIL-HDBK-217F (25 )℃
52.4*27.2*24mm (L*W*H)
0.05Kg/240pcs/13Kg/0.97CUFT
IRM-20 series
20W AC-DC PCB-Mount Green Power Module
40ms/230VAC 8ms/115VAC at full load
85 ~ 305VAC 120 ~ 430VDC
79%76% 84%
13.8 ~ 16.2V
84%
17.25 ~ 20.25V
85%
27.6 ~ 32.4V
0.6A/115VAC 0.4A/230VAC 0.3A/277VAC
COLD START 20A/115VAC 40A/230VAC
115%~160% rated output power
5.75 ~ 6.75V3.8 ~ 4.46V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
±1% ±1%
±0.3%
±0.5%
±0.3%
±0.5%
±0.3%
±0.5%
±0.5% ±0.5%
±2.5%±2.5% ±2.5% ±2.5% ±2.5%
200mVp-p200mVp-p 200mVp-p 200mVp-p 200mVp-p
3.3V 12V 15V 24V
4A4.5A 1.8A 1.4A 0.9A
0 ~ 4A0 ~ 4.5A 0 ~ 1.8A 0 ~ 1.4A 0 ~ 0.9A
20W14.85W 21.6W 21W 21.6W
IRM-20-5 IRM-20-12 IRM-20-15 IRM-20-24IRM-20-3.3
5V