G6B G6B
3
Contact Ratings
Item SPST-NO SPST-NO
+ SPST
-NC, DPST-NO, DPST-NC
Load
Resistive load
(cosφ
= 1)
Inductive load
(cosφ
= 0.4; L/R = 7 ms)
Resistive load
(cosφ
= 1)
Inductive load
(cosφ
= 0.4; L/R = 7 ms)
Rated load
5 A at 250 V
AC;
5A at 30 VDC
2 A at 250 V
AC;
2 A at 30 VDC
5 A at 250 V
AC;
5A at 30 VDC
1.5 A at 250 V
AC;
1.5 A at 30 VDC
Contact material
AgCdO
Rated carry current
5 A
Max. switching voltage
380 V
AC, 125 VDC
Max. switching current
5 A
Max. switching capacity
1,250 V
A, 150 W
500 V
A, 60 W
1,250 V
A, 150 W
375 V
A, 80 W
Min. permissible load0
10 mA at 5 VDC
Item SPST-NO (High-capacity)
Load Resistive load (cosφ
= 1)
Inductive load (cos
φ
= 0.4; L/R = 7 ms)
Rated load
8 A at 250 V
AC; 5A at 30 VDC
2 A at 250 V
AC; 2 A at 30 VDC
Contact material
AgCdO
Rated carry current
8 A
Max. switching voltage
380 V
AC, 125 VDC
Max. switching current
8 A
Max. switching capacity
2,000 V
A, 150 W
Min. permissible load0
10 mA at 5 VDC
Note:
P level:
λ60
= 0.1 x 10
–6/operation
Characteristics
Contact
resistance
30 m
Ω
max.
Operate (set) time
10 ms max. (mean value: 1-pole approx. 3 ms, 2-pole approx. 4 ms)
Release (reset) time
Single-side stable types:
10 ms max. (mean value: 1-pole approx. 1 ms, 2-pole approx. 2 ms)
Latching types:
10 ms max. (mean value: approx. 3 ms)
Min. set/reset signal width
Latching type: 15 ms min. (at 23
°C)
Max. operating frequency
Mechanical:
18,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
Ω
min. (at 500 VDC)
Dielectric strength
3,000 V
AC (Latching types: 2,000 V
AC), 50/60 Hz for 1 min between coil and contacts
1,000 V
AC, 50/60 Hz for 1 min between contacts of same polarity
250 V
AC, 50/60 Hz for 1 min between set and reset coils
2,000 V
AC, 50/60 Hz for 1 min between contacts of dif
ferent polarity
V
ibration resistance
Destruction:
10 to 55 Hz, 1.5-mm double amplitude
Malfunction:
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction:
1,000 m/s
2
(approx. 100G)
Malfunction:
Single-side stable: 100 m/s
2
(approx. 10G); Latching: 300 m/s
2
(approx. 30G)
Life expectancy
Mechanical:
50,000,000 operations min. (at 18,000 operations/hr)
Electrical:
100,000 operation min. (at 1,800 operations/hr)
Ambient temperature
Operating: –25°
C to 70
°
C (with no icing)
Storage: –25°
C to 70
°
C (with no icing)
Ambient humidity
Operating:
45% to 85%
Storage:
45% to 85%
Weight
Double-winding latching:
Approx. 3.7 g
High-capacity:
Approx. 4.6 g
Double pole:
Approx. 4.5 g
Other:
Approx. 3.5 g
Note:
The data shown above are initial value