Fluke Industrial Thermal Imagers Models: Ti32, Ti25 and Ti10 Technical Data High performance thermal imagers have never been this affordable. This rugged. Or, this easy to use ... until now. Ti32 Ti25 Industrial, mechanical, electromechanical and general building maintenance. Process, refractory insulation, tank and vessel levels, steam systems and traps, pipes and valves, etc. Electrical, unbalanced loads, overloaded systems, wiring mistakes or component failure, etc. We, at Fluke, are never satisfied leaving the best tools in the hands of the elite, which is why we recently added a new member to our thermal imaging family. The new Fluke Ti32 combines a powerful 320x240 sensor into the award winning, rugged design of the Ti25 and Ti10, delivering the first industrial grade, high performance thermal imager. The result is strikingly crisp, detailed images that, blended with our patented IR-Fusion(R), are sure to make a lasting impression. Don't take our word for it--see it yourself! Fluke thermal imagers are designed, tested, and manufactured in the USA, and feature a two year warranty. Work in a harsh environment? Don't worry. These meet the stringent quality standards that Fluke products are known for worldwide. Able to withstand a 2 meter (6.5 foot) drop, they also meet the requirements for an IP54 rating against dust and moisture. For added versatility and special applications, the Ti32 includes two field-swappable, rechargeable batteries. Use the optional telephoto and wide-angle lenses to bring distant and wide views into sharp focus. Incredible performance at unbelievably low prices. Fluke. Not just infrared, infrared you can use.(R) IR-Fusion(R) Technology, standard on ALL Fluke thermal imagers More than picture in picture Infrared images alone can be difficult to understand, which is why Fluke pioneered IR-Fusion, a revolutionary marriage of visible and infrared images never before seen in commercial or industrial thermal imagers. Automatically capturing a visible image with every infrared image allows to you always know exactly what you're looking at. Not all fusion is created equal Don't be fooled by imitators. Patented IR-Fusion is the only solution with physical parallax correction, enabling the perfect alignment and blending of both infrared and visible images. While many manufacturers have attempted to duplicate Fluke IR-Fusion, none have been able to match it. Turn to Fluke IR-Fusion to deliver the industry's best thermal images. Detailed specifications Temperature Temperature measurement range (not calibrated below -10 C) Temperature measurement accuracy On-screen emissivity correction On-screen reflected background temperature compensation On-screen transmission correction Imaging performance Image capture frequency Detector type Ti32 Ti25 Ti10 -20 C to +600 C (-4 F to +1112 F) -20 C to +350 C (-4 F to +662 F) -20 C to +250 C (-4 F to +482 F) Yes 5 C or 5 % (at 25 C nominal, whichever is greater) -- Yes -- 2 C or 2 % (at 25 C nominal, whichever is greater) Yes 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation 320 X 240 Focal Plane Array, uncooled microbolometer 0.05 C at 30 C target temp. (50 mK) -- 9 Hz refresh rate 160 X 120 Focal Plane Array, uncooled microbolometer Thermal sensitivity (NETD) 0.1 C at 30 C target temp. (100 mK) 0.2 C at 30 C target temp. (200 mK) Infrared spectral band 7.5 m to 14 m (long wave) Visual (visible light) camera Industrial performance 2.0 megapixel Industrial performance 1.3 megapixel Minimum focus distance 46 cm (approx. 18 in) Standard infrared lens type Field of view 23 x 17 Spatial resolution (IFOV) 1.25 mRad 2.5 mRad 2.5 mRad Minimum focus distance 15 cm (approx. 6 in) Optional telephoto infrared lens type Field of view 11.5 x 8.7 -- Spatial resolution (IFOV) 0.63 mRad -- Minimum focus distance 45 cm (approx. 18 in) -- Optional wide-angle infrared lens type Field of view 46 x 34 -- Spatial resolution (IFOV) 2.50 mRad -- Minimum focus distance 7.5 cm (approx. 3 in) -- Focus mechanism Manual, one-handed Smart Focus capability Image presentation Palettes Standard Ironbow, Blue-Red, High Contrast, Ironbow, Blue-Red, High Contrast, Ironbow, Blue-Red, Amber, Amber Inverted, Hot Metal, Amber, Hot Metal, Grayscale High Contrast, Grayscale Grayscale, Grayscale Inverted Ironbow Ultra, Blue-Red Ultra, High ConUltra ContrastTM trast Ultra, Amber Ultra, Amber Inverted -- Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra Level and span Smooth auto-scaling and manual scaling of level and span Fast auto toggle between manual Yes -- and auto modes Fast auto-rescale in manual mode Yes -- Minimum span (in manual mode) 2.5 C (4.5 F) 5 C (9 F) Minimum span (in auto mode) 5 C (9 F) 10 C (18 F) IR-Fusion(R) information Automatically aligned (parallax Yes corrected) visual and IR blending Picture-In-Picture (PIP) Three levels of on-screen IR blending displayed in center of LCD 100 % IR displayed in center of LCD Full screen infrared Three levels of on-screen IR blending displayed on LCD 100 % IR displayed on LCD Color alarms (temperature alarms) High-temperature alarm (user-selectable) -- Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager -- Image capture and data storage The Ti32 allows user to adjust palette, The Ti25 allows user to adjust palette, blending, level, span, IR-Fusion(R) mode, blending, level, span, IR-Fusion(R) mode, emissivity, and reflected background emissivity, and reflected background -- temperature compensation, and temperature compensation on a captured transmission correction on a captured image before it is stored. image before it is stored. Image capture, review, save One-handed image capture, review, and save capability mechanism Storage medium SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader File formats Non-radiometric (.bmp) or (.jpeg) or Non-radiometric (.bmp) or fully-radiometric (.is2) fully-radiometric (.is2) No analysis software required for No analysis software required for non-radiometic bitmap (.bmp) files non-radiometric (.bmp and .jpeg) files Export file formats w/SmartView(R) BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF software Memory review Thumbnail view navigation and Sequential image navigation and review review selection 2 Fluke Corporation Ti32, Ti25 and Ti10 Industrial Thermal Imagers General specifications -10 C to +50 C (14 F to 122 F) -20 C to +50 C (-4 F to 122 F) without batteries 10 % to 95 % non-condensing 9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover User selectable temperature scale (C/F) Language selection Time/Date set Emissivity selection (Ti32 and Ti25 only) Reflected background temperature compensation (Ti32 and Ti25 only) Transmission correction (Ti32 only) User selectable hot spot and cold spot, and center point on the image (other custom markers and shapes in SmartView(R) software) (Ti32 and Ti25 only) High temperature alarm (Ti32 only) User selectable backlight: "Full Bright" or "Auto" Information display preference (Ti32 only) Software SmartView(R) full analysis and reporting software included Batteries Ti32: Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level Ti25 and Ti10: Internal rechargeable battery pack (included) Battery life Ti32: Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD) Ti25 and Ti10: Three to four hours continuous use (assumes 50 % brightness of LCD) Battery charge time 2.5 hours to full charge AC battery charging Ti32: Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter. Ti25 and Ti10: AC adapter/charger (110 V ac to 220 V ac, 50/60 Hz) (included), charges battery while imager is operating or turned off, ac mains adapters included. AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included. Power saving Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 Electromagnetic compatibility Meets all applicable requirements in EN61326-1:2006 C Tick IEC/EN 61326-1 US FCC CFR 47, Part 15 Class B Vibration 0.03 g2/Hz (3.8 grms), IEC 68-2-6 Shock 25 g, IEC 68-2-29 Drop Ti32: 2 meter (6.5 feet) with standard lens, Ti25 and Ti10: 2 meter (6.5 feet) Size (H x W x L) Ti32: 27.7 cm x 12.2 cm x 17.0 cm (10.9 in x 4.8 in x 6.7 in), Ti25 and Ti10: 26.7 cm x 12.7 cm x 15.2 cm (10.5 in x 5.0 in x 6.0 in) Weight (battery included) Ti32 1.05 kg (2.3 lb), Ti25 and Ti10: 1.2 kg (2.6 lb) Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions) Warranty Two-years (standard) Recommended calibration cycle Two-years (assumes normal operation and normal aging) Supported Languages Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish Operating temperature Storage temperature Relative humidity Display Controls and adjustments Ordering information FLK-Ti32 9Hz Industrial-Commercial Thermal Imager, 9 Hz FLK-Ti32 60Hz Industrial-Commercial Thermal Imager, 60 Hz Included with Ti32 models Thermal imager with standard infrared lens; ac power supply and battery pack charger (including mains adapters); two, rugged lithium ion smart battery packs; SD memory card; multi-format USB memory card reader for downloading images into your computer; SmartView(R) software with free software upgrades for life; rugged, hard carrying case; soft transport bag; adjustable hand strap; printed users manual; warranty registration card; interactive training DVD. Fluke. Not just infrared. Infrared you can use.TM FLK-Ti25 9Hz Thermal Imager FLK-Ti10 9Hz Thermal Imager Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Included with Ti25 and Ti10 models Thermal imager with standard infrared lens, ac power supply/battery charger (including mains adapters); SD memory card; multi-format USB memory card reader for downloading images into your computer; SmartView(R) software with free software upgrades for life; rugged, hard carrying case; soft transport bag; adjustable hand strap; printed users manual; warranty registration card; interactive training DVD. Optional accessories FLK-LENS/TELE1 Telephoto Infrared Lens (Ti32 only) FLK-LENS/WIDE1 Wide-angle Infrared Lens (Ti32 only) TI-CAR-CHARGER Thermal Imager Vehicle Charger TI-VISOR Thermal Imager Visor BOOK-ITP Introduction to Thermography Principles Book TI-TRIPOD Tripod Mounting Base Accessory Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com (c)2009 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 8/2009 3467124D D-EN-N Modification of this document is not permitted without written permission from Fluke Corporation. 3 Fluke Corporation Ti32, Ti25 and Ti10 Industrial Thermal Imagers Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Fluke: FLK-TI32 60HZ