1
CSM_E6A2-C_DS_E_7_1
Incremental 25-mm-dia. Rotary Encoder
E6A2-C
Compact Encoder with External
Diameter of 25 mm
Incremental model
External diameter of 25 mm.
Resolution of up to 500 ppr.
Be sure to read Safety Precautions on
page 3.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Ordering Information
Encoders [Refer to Dimensions on page 4.]
* Only a 2-m cable is available for the 20P/R Model.
Accessories (Order Separately) [Refer to Dimensions on Rotary Encoder Accessories.]
Refer to Accessories for details.
Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model
5 to 12 VDC
Voltage output
Phases A, B, and Z
100, 200, 360 E6A2-CWZ3E (resolution) 0.5M
Example: E6A2-CWZ3E 100P/R 0.5M
500
Open-collector output
(NPN output)
100, 200, 360 E6A2-CWZ3C (resolution) 0.5M
Example: E6A2-CWZ3C 100P/R 0.5M
500
12 to 24 VDC 100, 200, 360 E6A2-CWZ5C (resolution) 0.5M
Example: E6A2-CWZ5C 100P/R 0.5M
500
5 to 12 VDC
Voltage output
Phases A and B
100, 200, 360 E6A2-CW3E (resolution) 0.5M
Example: E6A2-CW3E 100P/R 0.5M
500
Open-collector output
(NPN output)
100, 200, 360 E6A2-CW3C (resolution) 0.5M
Example: E6A2-CW3C 100P/R 0.5M
500
12 to 24 VDC 100, 200, 360 E6A2-CW5C (resolution) 0.5M
Example: E6A2-CW5C 100P/R 0.5M
500
5 to 12 VDC
Voltage output
Phase A
10, (20) *, 60, 100, 200, 300,
360 E6A2-CS3E (resolution) 0.5M
Example: E6A2-CS3E 10P/R 0.5M
500
Open-collector output
(NPN output)
10, 20, 60, 100, 200, 300, 360 E6A2-CS3C (resolution) 0.5M
Example: E6A2-CS3C 10P/R 0.5M
500
12 to 24 VDC 10, 20, 60, 100, 200, 300, 360 E6A2-CS5C (resolution) 0.5M
Example: E6A2-CS5C 10P/R 0.5M
500
Name Model Remarks
Coupling E69-C04B Provided with the product.
Servo Mounting Bracket E69-1 Provided with the E6A2-CWZ@.
2
E6A2-C
Ratings and Specifications
*1. An inrush current of approximately 9 A will flow for approximately 0.3 ms when the power is turned ON.
*2. The maximum electrical response speed is determined by the resolution and maximum response frequency as follows:
This means that the E6A2-C Rotary Encoder will not operate electrically if its speed exceeds the maximum electrical response speed.
*3. No protection is provided against water or oil.
Item
Model E6A2-
CWZ3E
E6A2-
CWZ3C
E6A2-
CWZ5C E6A2-CW3E E6A2-CW3C E6A2-CW5C E6A2-CS3E E6A2-CS3C E6A2-CS5C
Power supply
voltage
5 VDC 5% to 12 V +10%
ripple (p-p): 5% max.
12 VDC
10% to
24 VDC
+15%, ripple
(p-p): 5%
max.
5 VDC 5% to 12 V +10%,
ripple (p-p): 5% max.
12 VDC
10% to
24 VDC
+15%, ripple
(p-p): 5%
max.
5 VDC 5% to 12 V +10%,
ripple (p-p): 5% max.
12 VDC
10% to
24 VDC
+15%, ripple
(p-p): 5%
max.
Current
consumption*150 mA max. 30 mA max. 30 mA max. 20 mA max. 30 mA max. 20 mA max.
Resolution (pulses/
rotation) 100, 200, 360, 500 10, 20, 60, 100, 200, 300, 360, 500
Output phases Phases A, B, and Z Phases A and B Phase A
Output configuration Voltage out-
put NPN open-collector output Voltage out-
put NPN open-collector output Voltage out-
put NPN open-collector output
Output capacity
Output resis-
tance: 2 kΩ
Output cur-
rent: 20 mA
max.
Residual volt-
age: 0.4 V
max.
(Output cur-
rent: 20 mA
max.)
Applied voltage: 30 VDC
max.
Sink current: 30 mA max.
Residual voltage: 0.4 V max.
(at sink current of 30 mA)
Output resis-
tance: 2 kΩ
Output cur-
rent: 20 mA
max.
Residual volt-
age: 0.4 V
max.
(Output cur-
rent: 20 mA
max.)
Applied voltage: 30 VDC
max.
Sink current: 30 mA max.
Residual voltage: 0.4 V max.
(at sink current of 30 mA)
Output resis-
tance: 2 kΩ
Output cur-
rent: 20 mA
max.
Residual volt-
age: 0.4 V
max.
(Output cur-
rent: 20 mA
max.)
Applied voltage: 30 VDC
max.
Sink current: 30 mA max.
Residual voltage: 0.4 V max.
(at sink current of 30 mA)
Maximum response
frequency*230 kHz
Phase difference
between outputs Phase difference between phases A and B: 90°±45°---
Output duty factor --- 50±25%
Rise and fall times of
output
1.0 μs max.
(Cable
length:
500 mm,
Sink current:
10 mA)
1.0 μs max. (Cable length:
500 mm, Control output volt-
age: 5 V, Load resistance:
1kΩ)
1.0 μs max.
(Cable
length:
500 mm,
Sink current:
10 mA)
1.0 μs max. (Cable length:
500 mm, Control output volt-
age: 5 V, Load resistance:
1kΩ)
1.0 μs max.
(Cable
length:
500 mm,
Sink current:
10 mA)
1.0 μs max. (Cable length:
500 mm, Control output volt-
age: 5 V, Load resistance:
1kΩ)
Starting torque 1 mN·m max.
Moment of inertia 1 × 107 kg·m2 max.
Shaft
loading
Radial 10 N
Thrust 50 N
Maximum
permissible speed 5,000 r/min
Ambient temperature
range Operating: 10 to 55°C (with no icing), Storage: 25 to 80°C (with no icing)
Ambient humidity
range Operating/storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500m/s2 3 times each in X, Y, and Z directions
Degree of
protection*3IEC 60529 IP50
Connection method Pre-wired Models (Standard cable length: 500 mm)
Material Case: Aluminum alloy, Main unit: Aluminum, Shaft: SUS420J2, Mounting Bracket: Galvanized iron
Weight
(packed state) Approx. 35 g
Accessories Coupling, Servo Mounting Bracket (provided with the E6A2-CWZ@), Hexagonal wrench, Instruction manual
Maximum electrical response speed (rpm) = Maximum response frequency
Resolution × 60
E6A2-C
3
I/O Circuit Diagrams
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the Encoder under ambient conditions that exceed the ratings.
Wiring
Spurious pulses may be generated when power is turned ON and
OFF. Wait at least 0.1 s after turning ON the power to the Encoder
before using the connected device, and stop using the connected
device at least 0.1 s before turning OFF the power to the Encoder.
Also, turn ON the power to the load only after turning ON the power
to the Encoder.
Model/Output Circuits Output mode Connection
E6A2-CS3C
E6A2-CS5C
0 V
E6A2-C@@3C: +5 to 12 V
(
E6A2-C@@5C: +12 to 24V
)
Vcc
E6A2
main
circuit
Brown
Blue
Black, white, orange
30 VDC
30 mA max.
(Black: phase A,
White: phase B,
Orange: phase Z)
Output
ON
OFF
T(100%)
1/2T±1/4T (50%±25%)
Output transistor
The ONs in the above timing chart mean that the
output transistor is ON and the OFFs mean that the
output transistor is OFF.
Note: 1. The white and orange wires
of Single Models (E6A2-
CS@@) do not output
signals (no connection).
2. The white and orange wires
of Single Models (E6A2-
CS@@) do not output
signals (no connection).
3. Voltage Output Models are
capable of sinking a
maximum current of 20 mA.
Color Signal
Brown Vcc
Black Phase A
White Phase B
Orange Phase Z
Blue 0 V (common)
E6A2-CW3C
E6A2-CW5C
E6A2-CWZ3C
E6A2-CWZ5C
0 V
E6A2-C@@3C: +5 to 12 V
(
E6A2-C@@5C: +12 to 24V
)
Vcc
E6A2
main
circuit
Brown
Blue
Black, white, orange
30 VDC
30 mA max.
(Black: phase A,
White: phase B,
Orange: phase Z)
Output
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T(360˚)
1/4±1/8T (90˚±45˚) 1/4±1/8T (90˚±45˚)
T(360˚)
Phase A
Phase B
Phase Z
Phase A
Phase B
Phase Z
CW CCW
E6A2-CW3E
E6A2-CWZ3E
0 V
2 kΩ
Vcc (+5 to 12 V)
E6A2
main
circuit
Brown
Blue
20 mA
max.
Black, white, orange
Output (Black: phase A,
White: phase B,
Orange: phase Z)
Outputtransistor
Direction of rotation: CW
(as viewed from end of shaft)
Direction of rotation: CCW
(as viewed from end of shaft)
Note: Phase A is 1/4 T ± 1/8 T
faster than phase B.
Note: Phase A is 1/4 T ± 1/8 T
slower than phase B.
H
L
H
L
H
L
H
L
H
L
H
L
T(360˚)
1/4±1/8T(90˚±45˚) 1/4±1/8T(90˚±45˚)
T(360˚)
Phase A
Phase B
Phase Z
Phase A
Phase B
Phase Z
CW CCW
“H” and “L” in the diagrams are the output voltage
levels of phases A, B, and Z.
E6A2-CS3E
0 V
2 kΩ
Vcc (+5 to 12 V)
E6A2
main
circuit
Brown
Blue
20 mA
max.
Black, white, orange
Output (Black: phase A,
White: phase B,
Orange: phase Z)
“H” and “L” in the diagrams are the output voltage
levels.
H
L
T(100%)
1/2T±1/4T (50%±25%)
Output transistor
WARNING Precautions for Correct Use
4
E6A2-C
(Unit: mm)
Dimensions Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
Encoder
Accessories (Order Separately)
Coupling Servo Mounting Bracket
E69-C04B E69-1
Refer to Accessories for details.
12
0
-
0.05
dia.
4
0
-0.012
dia.
3.6
22 dia.
1.5
1.5
8
(46.5)
22910
*
6
5.5
25 dia.
18±
0.2
* 4-dia. vinyl-insulated round cable with 5 conductors (Conductor cross
section: 0.14 mm2, Insulator diameter: 0.9 mm),
Standard length: 500 mm
Two, M3 holes,
Depth: 4
E6A2-C
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyers request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.1
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
E6A2-CS3C 100P/R 0.5M E6A2-CS3C 10P/R 0.5M E6A2CS3C 200P/R 0.5M E6A2-CS3C 200P/R 2M E6A2-CS3C
300P/R 0.5M E6A2-CS3C 360P/R 0.5M E6A2-CS3C 360P/R 2M E6A2-CS3C 500P/R 0.5M E6A2-CS3C 60P/R 0.5M
E6A2-CS3E 100P/R 0.5M E6A2-CS3E 10P/R 0.5M E6A2-CS3E 200P/R 0.5M E6A2-CS3E 300P/R 0.5M E6A2-
CS3E 360P/R 0,5M E6A2-CS3E 60P/R 0.5M E6A2-CS5C 100P/R 0.5M E6A2-CS5C 100P/R 2M E6A2-CS5C 10P/R
0.5M E6A2-CS5C 10P/R 2M E6A2-CS5C 200P/R 0.5M E6A2-CS5C 300P/R 0.5M E6A2-CS5C 360P/R 0.5M E6A2-
CS5C 500P/R 0.5M E6A2-CS5C 60P/R 0.5M E6A2-CS5C 60P/R 2M E6A2-CW3C 100P/R 0.5M E6A2-CW3C 100P/R
2M E6A2-CW3C 200P/R 0.5M E6A2-CW3E-100P/R 0.5M E6A2-CW3E 200P/R 0.5M E6A2-CW5C 100P/R 0.5M
E6A2-CW5C100 P/R 2M E6A2-CW5C 200P/R 0.5M E6A2-CW5C 200P/R 2M E6A2-CWZ3C 100P/R 0.5M E6A2-
CWZ3C 100P/R 2M E6A2-CWZ3C 200P/R 0.5M E6A2-CWZ3E 100P.R 0.5M E6A2-CWZ3E 200P/R 0.5M E6A2-
CWZ5C 360P/R 0.5M E6A2-CW3C 200P/R 2M E6A2-CW5C 500P/R 0.5M E6A2-CWZ5C 500P/R 0.5M E6A2-CS3C
200P/R 0.5M E6A2-CW5C-100P/R 2M E6A2-CS3E 360P/R 2M