General Purpose Relays MKS Exceptionally Reliable General Purpose Relay now available with Lockable Test Button * IEC Rating of 7A 250 V AC 50/60 Hz, General use 100,000 cycles. * Mechanical indicator standard for all models. * Optional features include lockable test button, LED indicator, diode surge suppression, varistor, reverse polarity, and alternate wiring styles. * UL (RU/CRU), CE and TUV approved. * RoHS Compliant. Features Two-way Action Test Button (Models with Lockable Test Button) Relay in Normal Operation For Momentary Operation Yellow button Slide the latching lever to the first position, then press the yellow button with an insulated tool to operate the contact. For Lock Operation Slide the latching lever to the second position. (The contact is now in the locked position.) Note: The latching lever is Red for AC Coil versions and Blue for DC Coil versions. Model Number Structure Model Number Legend MKS@@@@@-@-@ 1 2 3 4 5 6 7 1. Contact Form 2: DPDT 3: 3PDT 2. Terminals P: Plug-in 3. Mechanical Indicator/Test Button Blank:Mechanical indicator I: Mechanical indicator and lockable test button 4. LED Indicator Blank: Standard N: LED indicator 5. Coil Polarity Blank: Standard 1: Reverse polarity (DC coil only) 6. Surge Absorption Blank:Standard D: Surge absorber diode (DC coil only) V: Surge absorber varistor (AC coil only) 7. Internal Connections DPDT Blank: Standard 2 or 5: Non-standard connections.(Refer to "Terminal Arrangement/Internal Connection (Bottom View)".) 8. Rated Voltage (Refer to "Coil Ratings".) General Purpose Relays MKS 299 Ordering Information List of Models Type Terminals Contact form Basic Models Plug-in DPDT 3PDT Models with LED Indicator (See note 2.) DPDT 3PDT Models with Diode (See note 2.) DPDT 3PDT Models with LED Indicator and Diode DPDT 3PDT Models with Varistor DPDT 3PDT Models with LED Indicator and Varistor DPDT 3PDT Internal connections (See note 3.) With mechanical indicator With mechanical indicator Coil ratings and lockable test button Standard MKS2P MKS2PI Non Standard MKS2P-2 MKS2PI-2 Standard MKS3P MKS3PI Non Standard MKS3P-2 MKS3PI-2 MKS3P-5 MKS3PI-5 Standard MKS2PN(1) MKS2PIN(1) Non Standard MKS2PN(1)-2 MKS2PIN(1)-2 Standard MKS3PN(1) MKS3PIN(1) Non Standard MKS3PN(1)-2 MKS3PIN(1)-2 MKS3PN(1)-5 MKS3PIN(1)-5 Standard MKS2P(1)-D MKS2PI(1)-D Non Standard MKS2P(1)-D-2 MKS2PI(1)-D-2 Standard MKS3P(1)-D MKS3PI(1)-D Non Standard MKS3P(1)-D-2 MKS3PI(1)-D-2 MKS3P(1)-D-5 MKS3PI(1)-D-5 Standard MKS2PN-D MKS2PIN-D Non Standard MKS2PN-D-2 MKS2PIN-D-2 Standard MKS3PN-D MKS3PIN-D Non Standard MKS3PN-D-2 MKS3PIN-D-2 MKS3PN-D-5 MKS3PIN-D-5 Standard MKS2P-V MKS2PI-V Non Standard MKS2P-V-2 MKS2PI-V-2 Standard MKS3P-V MKS3PI-V Non Standard MKS3P-V-2 MKS3PI-V-2 MKS3P-V-5 MKS3PI-V-5 Standard MKS2PN-V MKS2PIN-V Non Standard MKS2PN-V-2 MKS2PIN-V-2 Standard MKS3PN-V MKS3PIN-V Non Standard MKS3PN-V-2 MKS3PIN-V-2 MKS3PN-V-5 MKS3PIN-V-5 AC/DC AC/DC DC DC AC AC Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications. Example: MKS2P DC48 Rated voltage 2. The DC coil comes in two types: standard coil polarity and reverse coil polarity. Refer to Terminal Arrangement and Internal Connections. Example: MKS3PN1-5 DC24 Reverse coil polarity 3. Refer to Terminal Arrangement and Internal Connections for all wiring diagrams. 10A Sockets (Order Separately) Item Type Track-mounted Socket PF083A-E 11-pin PF113A-E 8-pin PF083A-D 11-pin PF113A-D Hold-down Clip (For PF083A-E and PF113A-E) 300 Model 8-pin General Purpose Relays PFC-A1 MKS Specifications Ratings Coil Ratings Rated voltage Rated current 50 Hz AC DC Coil resistance 60 Hz 6V 443 mA 385 mA 3.1 12 V 221 mA 193 mA 13.7 24 V 110 mA 96.3 mA 48.4 100 V 26.6 mA 23.1 mA 760 110 V 24.2 mA 21.0 mA 932 120 V 22.2 mA 19.3 mA 1,130 200 V 13.3 mA 11.6 mA 3,160 220 V 12.1 mA 10.5 mA 3,550 230 V 11.5 mA 10.0 mA 4,250 240 V 11.0 mA 9.6 mA 4,480 6V 224 mA 26.7 12 V 112 mA 107 24 V 55.8 mA 430 48 V 28.1 mA 1,710 100 V 13.5 mA 7,390 110 V 12.3 mA 8,960 125 V 10.8 mA 11,576 Must operate voltage Must release voltage Max. voltage Power consumption 80% max. of rated 30% min. of rated 110% of rated voltvoltage voltage at 60 Hz age 25% min. of rated voltage at 50 Hz Approx. 2.3 VA at 60 Hz Approx. 2.7 VA at 50 Hz 15% min. of rated voltage Approx. 1.4 W Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of +15%/-20% for AC rated current and 15% for DC coil resistance. 2. Performance characteristic data are measured at a coil temperature of 23C. 3. The maximum voltage is one that is applicable instantaneously to the Relay coil at 23C and not continuously. 4. For DC-operated Relays with the LED indicator built-in, add an LED current of approx. 5 mA to the rated current. Contact Ratings Load Resistive load (cos = 1) Contact mechanism Single Contact material Rated load AgSnIn NO 10 A, 250 VAC 10A, 30 VDC NC 5 A, 250 VAC 5 A, 30 VDC Rated carry current 10 A Max. switching voltage 250 VAC, 250 VDC Max. switching current Max. switching capacity Inductive load (p.f. = 0.4) 7 A, 250 VAC 10 A NO 2,500 VA/300 W NC 1,250 VA/150 W General Purpose Relays MKS 301 Characteristics Contact resistance 100 m max. Operate time AC: 20 ms max. DC: 30 ms max. Release time 20 ms max.(40 ms max. for built-in diode models) Max. operating frequency Mechanical: 18,000 operations/hr (no load) Electrical:1,800 operations/hr (at rated load) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC 50/60 Hz for 1 min. between coil and contacts 1,000 VAC 50/60 Hz for 1 min. between contacts of same polarity and terminals of the same polarity 2,500 VAC 50/60 Hz for 1 min. between current-carrying parts, non-current-carrying parts, and opposite polarity Insulation method Basic insulation Impulse withstand voltage 4.5 kV between coil and contacts (with 1.2 x 50 s impulse wave) 3.0 kV between contacts of different polarity (with 1.2 x 50 s impulse wave) Pollution degree 3 Rated insulation voltage 250 V Vibration resistance Destruction:10 to 55 Hz, 1.5 mm double amplitude Malfunction:10 to 55 Hz, 1.0 mm double amplitude Shock resistance Destruction:1,000 m/s2 (approx. 100 G) Malfunction:100 m/s2 (approx. 10 G) Life expectancy Mechanical: 5,000,000 operations min. Electrical:100,000 operations min. Min. permissible load 10 mA at 1 VDC P level: 60=0.1 x 10-6 / ops Ambient temperature Operating: -40 to 60C (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight Approx. 90 g Note: 1. The values given above are initial values. 2. Ambient temperature of models with LED indicator is -25 to 60C. Approved Standards UL Recognized (File No. E41515) - - Ambient Temp. = 40C Coil ratings Contact ratings Operations 6 to 110 VDC N.O. 6 to 240 VAC contact 10 A, 250 V AC 50/60 Hz (Resistive) 100,000 10 A, 30 V DC (Resistive) 7 A, 250 V AC 50/60 Hz (General Use) N.C. contact 10 A, 250 V AC 50/60 Hz (Resistive) 100,000 10 A, 30 V DC (Resistive) 7 A, 250 V AC 50/60 Hz (General Use) Note: 10A UL ratings are with no load on the other contact set. Number of Poles Contact ratings Operations 6 to 125 VDC 2 6 to 240 VAC 10 A, 250 V AC (Resistive) 10 A, 30 V DC (Resistive) 7 A, 250 V AC (General Use) 100,000 3 10 A, 250 V AC (Resistive) Same Polarity 10 A, 30 V DC (Resistive) Same Polarity 7 A, 250 V AC (General Use) Same Polarity 100,000 302 General Purpose Relays Coil ratings 6, 12, 24, 48, N.O. 100, 110 VDC contact 6, 12, 24, 100, 110, 200, 220, N.C. 240 VAC contact Contact ratings Operations 10 A, 250 V AC 50/60 Hz (Resistive) 100,000 10 A, 30 V DC (Resistive) 7 A, 250 V AC 50/60 Hz (General Use) 5 A, 250 V AC 50/60 Hz (Resistive) 100,000 5 A, 30 V DC (Resistive) 7 A, 250 V AC 50/60 Hz (General Use) Note: Maximum carrying current per TUV Certification is 9 A when new MK-S relays are mounted in PF083A-E or PF113A-E Sockets. CSA Certified (File No. LR35535) Coil ratings IEC Standard/TUV Certification: IEC61810-1 (Certification No. R50104853) MKS Engineering Data Reference Data Rated Carry Current vs. Ambient Rated Temperature Rated carry current (A) Switching current (A) Maximum Switching Power 100 50 30 DC resistive load with NO contact AC resistive load with NO contact 10 UL derating curve 10 5 AC inductive load (p.f. = 0.4) 5 3 AC resistive load with NC contact DC resistive load with NC contact 1 10 30 50 100 300 0 -40 500 1.000 -20 0 20 40 60 80 Ambient temperature (C) Switching voltage (V) Note: The lower limit of the ambient operating temperature for models with built-in operation indicators is -25C. Dimensions Note: All units are in millimeters unless otherwise indicated. Models without Test Button Models with Lockable Test Button 34.5 max. 34.5 max. 34.5 max. 0.8 52.5 max. 34.5 max. 0.8 52.5 max. Track Mounted Sockets See below for Socket dimensions. Poles Finger-protection models -- Maximum carry current 10 A 5A 2 poles PF083A-E PF083A-D PF083A 3 poles PF113A-E PF113A-D PF113A Note: If using the PF083A or PF113A Sockets, be sure the maximum carrying current is 5 A or less. When using finger-protection sockets, make sure the connecting wire terminals are Y-shaped. General Purpose Relays MKS 303 PF083A-E (Conforming to EN 50022) PF113A-E (Conforming to EN 50022) Terminal Arrangement Eight, M3.5 x 7 sems 7 Terminal Arrangement Eleven, M3.5 x 7 sems 4 7 52 max. 4 35.4 52 max. 2 3.5 33 41 max. 35.4 Mounting Holes 21 max. 4 3.5 34 42.8 max. Two, M4 or two 4.5-dia. holes Mounting Holes 2 Two, M4 or two 4.5-dia. holes 31 max. 330.2 330.2 PF113A-D PF083A-D Terminal Arrangement 8 24 6 5.5 Terminal Arrangemen 8 22 12 14 5 4 3 32 24 21 22 12 8 7 6 5 4 5.5 27 4 Eight, M4 screws 27 4 Eight, M4 screws 1 7 8 A2 21 11 9 10 2 3 34 A2 11 1 A1 14 31 11 2 A1 Mounting Holes 65 Mounting Holes 65 Two, M4 or two 4.5-dia. hole Two, M4 or two 4.5-dia. hol 30 30 38 38 Hold-down Clips Mounting Height with Sockets PFC-A1 Three poles (2 pieces per set) 4.6 60.8 Two poles 77.8 (See note.) 74.3 84.3 62 PF083A(-E) 6 87.8 (See note.) PF113A(-E) Note: PF083A(-E) and PF113A(-E) allow either track or screw mounting. 4.5 Mounting Tracks PFP-100N, PFP-50N (Conforming to EN 50022) PFP-100N2 (Conforming to EN 50022) 16 7.30.15 4.5 4.5 350.3 15 25 25 10 25 1000 (500)* 10 25 ** 15 (5) 1 * The figure in parenthesis is for PFP-50N. 304 General Purpose Relays 350.3 27 270.15 15 25 25 10 25 10004 25 15 10 ** A total of twelve 25 x 4.5 elliptic holes is provided with six holes cut from each track end at a pitch of 10 mm. MKS 24 29.2 1 1.5 Terminal Arrangement/Internal Connection (Bottom View) Basic Models (AC/DC Coil) MKS2P(I) 4 MKS2P(I)-2 5 3 4 6 MKS3P(I) 3 6 6 5 7 7 1 2 8 7 1 MKS2P(I)N 4 3 4 6 2 7 1 MKS2P(I)N-2 5 2 7 6 5 7 4 9 3 8 MKS2P(I)N 4 3 4 6 2 7 1 MKS2P(I)N-2 5 2 7 6 5 4 3 4 6 2 7 1 9 3 2 7 6 5 4 3 4 6 2 7 1 8 9 3 2 7 6 5 4 3 4 6 2 7 1 8 6 7 4 8 3 9 2 10 11 1 MKS3P(I)N1-5 8 4 9 3 2 6 5 7 8 3 9 2 10 10 1 11 MKS3P(I)-D-2 7 4 11 MKS3P(I)-D-5 4 8 3 9 6 5 4 8 3 10 9 2 MKS3P(I)1-D 8 3 9 2 10 MKS3P(I)1-D-2 11 1 11 1 7 4 10 11 6 5 7 MKS3P(I)1-D-5 5 3 6 2 7 1 6 1 8 MKS2P(I)1-D-2 5 MKS3P(I)N-5 10 5 7 1 MKS2P(I)1-D 11 1 11 MKS3P(I)N1-2 11 2 Diode Type (DC Coil: Reverse Polarity) 9 2 10 MKS3P(I)-D 6 1 9 10 2 5 3 8 8 1 8 MKS2P(I)-D-2 5 8 5 7 3 7 4 1 MKS2P(I)-D 6 4 10 2 Diode Type (DC Coil: Standard Polarity) 7 3 10 5 11 MKS3P(I)N1 6 1 6 4 5 3 8 11 MKS3P(I)N-5 11 MKS3P(I)N-2 8 MKS2P(I)N1-2 5 2 1 8 4 1 MKS2P(I)N1 9 7 2 LED Indicator Type (DC Coil: Reverse Polarity) 8 3 10 MKS3P(I)N 6 1 1 5 3 8 9 10 5 7 4 11 1 6 5 8 2 LED Indicator Type (DC Coil: Standard Polarity) 8 2 10 MKS3P(I)N-2 7 3 11 1 MKS3P(I)N 6 1 9 2 11 6 4 5 3 8 8 3 10 2 1 LED Indicator Type (AC Coil) MKS3P(I)-5 5 7 4 9 3 8 6 5 8 4 2 MKS3P(I)-2 5 6 5 7 8 4 3 9 8 2 10 1 11 6 5 4 8 3 9 2 10 1 6 5 7 8 9 3 2 10 1 11 General Purpose Relays 7 4 MKS 11 305 LED Indicator and Diode Type (DC Coil) MKS2P(I)N-D 4 MKS2P(I)N-D-2 5 3 4 6 6 5 7 8 4 2 2 7 1 8 7 1 3 8 9 2 MKS2P(I)-V 4 MKS2P(I)-V-2 5 3 4 1 8 7 1 6 5 MKS2P(I)N-V 4 3 8 9 2 MKS2P(I)N-V-2 5 3 4 2 1 8 6 5 10 11 1 MKS3P(I)-V-5 8 9 2 8 3 9 2 10 11 1 11 MKS3P(I)N-V-2 7 4 10 1 6 5 7 3 11 6 5 7 7 3 9 8 2 10 1 11 6 5 8 4 1 9 2 10 4 10 MKS3P(I)N-V 6 2 7 8 3 11 MKS3P(I)-V-2 7 4 MKS3P(I)N-V-5 5 3 6 2 7 8 1 LED Indicator and Varistor Type (AC Coil) 9 1 MKS3P(I)-V 6 2 7 8 3 6 5 7 4 11 4 2 MKS3P(I)N-D-5 5 3 6 6 5 10 1 Varistor Type (AC Coil) MKS3P(I)N-D-2 5 3 6 MKS3P(I)N-D 4 8 9 3 2 10 1 6 5 7 7 4 8 3 9 2 11 10 1 11 Safety Precautions Safety Precautions for Correct Use Installation Recommend mounting MK-S Relay so that side with wiring diagram is facing down. Handling Check coil polarity when wiring LED Indicator and Diode Models. Test Button Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely. Check that the test button is released before turning ON relay circuits. If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. Use an insulated tool when you operate the test button. Models with test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the Relay is in a complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only the requirements for basic insulation are fulfilled. 306 General Purpose Relays MKS MEMO General Purpose Relays MKS All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC Global - http://www.omron.com USA - http://www.components.omron.com 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X301-E-1b 09/11 General Purpose Relays Specifications subject to change without notice MKS Printed in USA