SPECIFICATION
GST220A series
ORDER NO.
DC VOLTAGE Note.2
SAFETY MODEL NO.
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
VOLTAGE RANGE Note.7
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS Note. 8
SAFETY &
EMC
(Note. 9)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
GST220A15
GST220A15-R7B
GST220A12
GST220A12-R7B
GST220A20
GST220A20-R7B
GST220A24
GST220A24-R7B
GST220A48
GST220A48-R7B
15V12V 20V 24V 48V
100mVp-p80mVp-p 120mVp-p 150mVp-p 200mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION
±5.0%±5.0% ±4.0% ±3.0% ±2.0%
±1.0%±1.0% ±1.0% ±1.0% ±1.0%
±5.0%±5.0% ±4.0% ±3.0% ±2.0%
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.91 / 230VAC PF>0.98 / 115VAC at full load
90%
90% 92% 93.5% 94.5%
4A / 115VAC 2A / 230VAC
0.75mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P: 3KVAC I/P-FG: 2KVAC O/P-FG:SHORT
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
209.4K hrs min. MIL-HDBK-217F(25 )℃
-30 ~ +70 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃℃0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
210*85*46mm (L*W*H)
1.1Kg; 12pcs/14.2Kg/0.96CUFT
CONNECTOR
PLUG
CABLE See page ; Other type available by customer requested
4~5
See page ; Other type available by customer requested
4~5
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
8. The demand for Malaysia safety is processed with the order no. GST220A -SIRIM by request. Please contact MEAN WELL for details.
9.
The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
OVERLOAD
OVER VOLTAGE
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
13.4A15A 11A 9.2A 4.6A
0 ~ 13.4A0 ~ 15A 0 ~ 11A 0 ~ 9.2A
0 ~ 4.6A
201W180W 220W 221W 221W
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
2000ms, 50ms / 230VAC 2000ms, 50ms / 115VAC at full load
20ms / 230VAC 20ms / 115VAC at full load
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
220WAC-DC High Reliability IndustrialAdaptor
Protection type : H modeiccup @ 10%load
UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J60950-1 ,,AS/NZS 60950.1
BIS IS13252, KC K60950-1, approvedEAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional)
(UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J60950-1,AS/NZS 60950.1
for GST220A36-R7B)
EMC IMMUNITY
EMC EMISSION
Parameter Standard
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN61000-3-2,GB9254
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11 >.95% dip 0 5 periods, 30% dip 25 periods,
95% interruptions 250 periods>
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
μ
μ
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
RF field susceptibility
EFT bursts
Surge susceptibility
Level 4, 15KV air; Level 4, 8KV contact
Conducted susceptibility
Magnetic field immunity
Voltage dips , interruption
Level 2, 3V/m
Level 3, 1KV/Line-Line , 2KV/Line-FG
Level 2, 3A/m
Level 2, 3V
Level 2, 1KV
File Name:GST220A-SPEC 2019-05-20
GST220A36
GST220A36-R7B
36V
200mVp-p
±2.0%
±1.0%
±2.0%
6.1A
0 ~ 6.1A
219.6W
93%
Cold start
95A / 115VAC 120A / 230VAC