PEB 20320
PEF 20320
Semiconductor Group 5 12.97
1.3.2 Reset
The RESET behaviour was changed between MUNICH32 V3.3 and MUNICH32 V3.4:
After po wer up a l o gi c al ’1’ at th e re se t pi n of th e M UNICH32 V 3. 4 s ets t he de v ic e int o a
reset state where the complete microprocessor bus interface is tristated and the internal
reset sequence is started.
The trailing edge of the reset starts the last part of the internal reset sequence and takes
about 12 SCLK cl ock cycles. It is no t allowed to give an AR du ring these first 12 SC LK
cycles after the trailing edge of RESET.
1.3.3 New version number
The version number is identified in the interrupt information bits VN(3:1):
these bits are ’110’ for version 3.4.
The version number in the boundary scan ID code is set to ’0110’ for version 3.4.
1.4 Electrical Characteristics
The MUNICH32 V3.4 is available for the extended range of temperature:
All other electrical characteristics are as specified in MUNICH32 User’s Manual 01.96.
Examples:
a) 0x7E, data1, 0x7E... • data1 in RAM
• status SF-Bit set
• FI indi cat ion inte rru pt
generated
• No SF interrupt
• ERR interrupt due to wrong
CRC
b) 0x7E, data=0xFC(or 0xFD, or 0x7F), 0x7E • no data in RAM
• SF, ERR-interrupt
Ambient temperature ratings
Parameter Symbol Limit Values Unit
Ambient temperature under bias: PEB
PEF TA
TA
0 to 70
-40 to 85 °C
°C