www.clare.com
2
LAA125L
Rev. 10
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Current Continuous IL- - 150 mA
Peak Load Current 10ms max ILPK - - 400 mA
Load Current Limiting ICL 190 235 280 mA
On-Resistance IL=Load Current RON - - 18 Ω
Off-State Leakage Current VL=350V ILEAK - - 1 μA
Switching Speeds
Turn-On IF=5mA, VL=10V TON - - 5 ms
Turn-Off IF=5mA, VL=10V TOFF - - 5 ms
Output Capacitance 50V; f=1MHz COUT - 50 - pF
Input Characteristics @ 25°C
Input Control Current IL=170mA IF5 - - mA
Input Dropout Current - - 0.4 0.7 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR- - 10 μA
Input to Output Capacitance - CI/O - 3 - pF
Parameter Ratings Units
Blocking Voltage 350 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
Isolation Voltage Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
Absolute Maximum Ratings (@ 25˚ C)
Electrical Characteristics