ABS6....ABS10 1.0 Amp. Miniature Single Phase Glass Passivated Surface Mount Bridge Rectifier Current 1.0 A Voltage 600 V to 1000 V THIN MINI-DIP FEATURES Saves space on printed circuit boards Ideal for automated placement High surge current capability Solder dip 260C, 10s Component in accordance to RoHS 2002/95/EC and WEEE 2002/96/EC Meets MSL level 1, per J-STD-020, LF maximum peak of 260 C Halogen-free available according to IEC 61249-2-21 definition MECHANICAL DATA Case : THIN MINI-DIP. Epoxy meets UL 94V-0 flammability rating. Polarity: As marked on body. Terminals : Matte tin plated leads, solderable per MIL-STD-750 Method 2026, J-STD-002 and JESD22-B102. Consumer grade, meets JESD 201 class 1A whisker test. TYPICAL APPLICATIONS Used in general purpose ac-to-dc bridge full wave rectification for power supply, lighting ballaster, Battery charger, home appliances, office equipement, and telecommunication applications. Maximun Ratings and Electrical Characteristics at 25C Marking Code Halogen Free Marking Code ABS6 ABS8 ABS10 ABS6 ABS8 ABS10 ABS6 HF 600 ABS8 HF 800 ABS10 HF 1000 VRRM Maximum Recurrent Peak Reverse Voltage (V) VRMS Maximum RMS Voltage (V) 420 560 700 VDC Maximum DC Blocking Voltage (V) Maximum average Forward Rectified Current On glass-Epoxy P.C.B. On aluminum substrate 600 800 1000 IF(AV) IFSM Rth (j-l) Rth (j-a) Peak Forward Surge Current, 8.3 ms Single Half Sine-wave Superimposed on Rated Load (JEDEC method) Typical Thermal Resistance Junction to Lead On aluminum substrate On Glass-Epoxy substrate 0.8 A 1.0 A 30 A 25 C/W 62.5 C/W 80 C/W Tj Operating Temperature Range -50 to + 150 C Tstg Storage Temperature Range -50 to + 150 C Electrical Characteristics at Tamb = 25 C VF IR Maximum Instantaneous Forward Voltage @ 0.4A Maximum DC Reverse Current @ TA = 25 C 0.95 V 10 A at Rated DC Blocking Voltage @ TA = 125 C 150 A www.fagorelectronica.com Document Name: abs Version: Nov-11 Page Number: 1/4 ABS6....ABS10 1.0 Amp. Miniature Single Phase Glass Passivated Surface Mount Bridge Rectifier Ordering information PREFERRED P/N PACKAGE CODE DELIVERY MODE BASE QUANTITY UNIT WEIGHT (g) ABS6 TR TR 13" diameter tape and reel 5,000 0.12 ABS10 HF TR TR 13" diameter tape and reel 5,000 0.12 A Mounting Pad Layout 0.85 0.65 0.7 0.6 www.fagorelectronica.com Document Name: abs 3.45 3.25 4.1 3.9 1.1 0.25 0.15 5.6 Week code 0.7 0.3 Marking code Year code 10 MC WWY 0~ 6.4 4.5 4.3 6 1.1 A 10:1 0.15 0.05 0.15 0.05 5.1 4.9 THIN MINI-DIP 1.5 MAX. 1.42 1.22 Package Outline Dimensions: (mm) 4 Version: Nov-11 Page Number: 2/4 ABS6....ABS10 1.0 Amp. Miniature Single Phase Glass Passivated Surface Mount Bridge Rectifier MAXIMUM FORWARD CURRENT DERATING CURVE 50 20 10 5 Tj = 150 C (Typ) Tj = 25 C (Typ) 2 1 0.5 0.2 0.1 0 0.2 0.4 0.6 0.8 1.0 1.2 VF, forward voltage (V) 1.4 1.6 IF(AV), average forward Current (A) TYPICAL FORWARD CHARACTERISTIC 1.6 1.4 1.2 40 35 30 25 20 IFSM 15 10 ms 10 ms 1 Cycle 10 Non-repetitive Sine wave, Tj = 25C Before Surge current is applied 5 0 1 10 Number of cycles (Cycle) 100 Alumina substrate 50.8 mm x 50.8 mm Soldeering lang 1 mm x 1mm Conductor layer 20 m Substrate thickness 0.64mm SIN 1.0 0.8 0.6 0.4 0.2 0 0 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT 20 40 60 80 100 120 140 160 Tamb, ambient temperature (C) FORWARD POWER DISSIPATION Forward power dissipation (pF) IFSM, peak forward surge current (A) IF, instantaneous forward current (A) Ratings and Characteristics (Ta 25 C unless otherwise noted) 2.5 SIN 2 1.5 1 0.5 0 0 0.2 0.4 0.6 0.8 1 IF(AV), average forward current (A) 1.2 IF(AV), average forward current (A) MAXIMUM FORWARD CURRENT DERATING CURVE 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 0 20 40 60 80 100 120 140 160 TL, lead temperature (C) www.fagorelectronica.com Document Name: abs Version: Nov-11 Page Number: 3/4 ABS6....ABS10 1.0 Amp. Miniature Single Phase Glass Passivated Surface Mount Bridge Rectifier Disclaimer All product, product specifications and data are subject to change without notice to improve reliability, function or design or otherwise. Fagor Electronica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge of typical requirements that are often placed on Fagor products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed therein. Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Fagor product could result in personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their respective owners. www.fagorelectronica.com Document Name: abs Version: Nov-11 Page Number: 4/4