PX-200
Crystal Oscillator
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Miniature Hybrid Design
16 Pin Flatpack
Frequency Range: 4 MHZ to 500 MHZ
Previous Model: CO-487
Features Applications
PX-200
Parameter Min Typ Max Units Condition
Frequency Stabilities1
vs. operating temperature range
(referenced to +25°C)
-5
-10
-25
-50
-50
-100
+5
+10
+25
+50
+50
+100
ppm
ppm
ppm
ppm
ppm
pbm
0… +50°C
0… +50°C
0… +70°C (standard)
-55… +85°C
-55… +125°C
-55… +125°C
Initial tolerance -50
-25
-15
-10
-1
+50
+25
+15
+10
+1
ppm
ppm
ppm
ppm
ppm
@+25°C
@+25°C
@+25°C
@+25°C
Set via external capacitor (custom number required)
vs. aging / 1 year
vs. aging / year (following years)
-3
-2
+3
+2
ppm
ppm
after 30 days of operation
Supply Voltage (Vs)
Supply voltage (Standard) 14.75 15.0 15.25 VDC
RF Output
Signal Sinewave
Output Power (Standard) +7 dBm
Performance Speci cations
Performance Speci cations
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Parameter Min Typ Max Units Condition
Output Power (Option) +13 dBm (custom number required)
Additional Parameters1
Phase Noise3 (typical 4-100 MHZ) -100
-125
-140
-145
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
100 Hz
1 kHz
10 kHz
100 kHz
Screen Testing of Above Models
SCREEN TEST MIL-STD-883
METHOD
Standard Options
CLASS X CLASS B CLASS S
Stabilization Bake (150°C) X X Class S screen test requirements include 24 hour
additional bake-out, 80 hour additional burn-
in, thermal shock, PIND test and radiographic
inspection in addition to Class B Screening. Has
major cost impact.
Seal Test (Gross and Fine) 1014, Cond A2 X X
Temperature Cycling (Thermal Shock) 1010, Cond B X
Burn-in, operating 160 hours @125°C X
Acceleration (5000g in Y1 axis) 2001, Cond A X
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Dimensions in inches
Type A
Code Height “H Pin Length “L
0 0.17 0.4
Pin Connections
8 Ground
9, 10 Output
11 <200 MHz: no connection
>200 Mhz: 0V, Case
16 Supply
Outline Drawing / Enclosure
Ordering Information
PX - 200 0 - A E T - F K X S - 10M0000000
Product Family
PX: PXO
Package
25 x 25 mm
Height
0: A 0.17”
Supply Voltage
A: 15 Vdc
Accuracy Code
B: ±10ppm
D: ±15ppm
F: ±25ppm
K: ±50ppm
Frequency
Screening Option
S: “S Level screening
B: “B” Level screening
X: No Screening
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Disclaimer
Vectron International reserves the right to make changes to the product(s) and or information contained herein without notice. No liability is assumed as a result of their use or application.
No rights under any patent accompany the sale of any such product(s) or information.
Rev: 2/23/2009 daf
For Additional Information, Please Contact
USA:
Vectron International
267 Lowell Road
Hudson, NH 03051
Tel: 1.888.328.7661
Fax: 1.888.329.8328
Europe:
Vectron International
Landstrasse, D-74924
Neckarbischofsheim, Germany
Tel: +49 (0) 3328.4784.17
Fax: +49 (0) 3328.4784.30
Asia:
Vectron International
1F-2F, No 8 Workshop, No 308 Fenju Road
WaiGaoQiao Free Trade Zone
Pudong, Shanghai, China 200131
Tel: 86.21.5048.0777
Fax: 86.21.5048.1881
RF Output Code
E: Sinewave (+7 dBm)
Temperature Range
A: -55°C to +85°C
C: -55°C to +125°C
P: 0°C to +50°C
T: 0°C to +70°C
Notes:
Contact factory for improved stabilities or additional product options. Not all options and codes are available at all 1.
frequencies.
Unless other stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency 2.
control voltage, load, temperature (25°C).
Phase noise degrades with increasing output frequency.3.
Subject to technical modi cation.4.
Contact factory for availability.5.
Stability Code
A: ±5ppm
B: ±10ppm
F: ±25ppm
K: ±50ppm
S: ±100ppm
Enable Code
X: No Option