G2SBA20, G2SBA60, G2SBA80 Vishay General Semiconductor Glass Passivated Single-Phase Bridge Rectifier FEATURES * UL recognition file number E54214 * Ideal for printed circuit boards * High surge current capability * Typical IR less than 0.1 A * High case dielectric strength ~ ~ ~ ~ * Solder dip 275 C max. 10 s, per JESD 22-B106 * Compliant to RoHS Directive 2002/95/EC and in accordance to WEEE 2002/96/EC Case Type GBL * Halogen-free according to IEC 61249-2-21 definition TYPICAL APPLICATIONS General purpose use in AC/DC bridge full wave rectification for monitor, TV, printer, SMPS, adapter, audio equipment, and home appliances applications. PRIMARY CHARACTERISTICS IF(AV) 1.5 A VRRM 200 V, 600 V, 800 V IFSM 60 A IR 5 A VF 1.0 V TJ max. 150 C MECHANICAL DATA Case: GBL Molding compound meets UL 94 V-0 flammability rating Base P/N-M3 - halogen-free and RoHS compliant, commercial grade Terminals: Matte tin plated leads, solderable per J-STD-002 and JESD 22-B102 M3 suffix meets JESD 201 class 1A whisker test Polarity: As marked on body MAXIMUM RATINGS (TA = 25 C unless otherwise noted) PARAMETER SYMBOL G2SBA20 G2SBA60 G2SBA80 UNIT Maximum repetitive peak reverse voltage VRRM 200 600 800 V Maximum RMS voltage VRMS 140 420 560 V Maximum DC blocking voltage VDC 200 600 800 V Maximum average forward rectified output current at TA = 25 C IF(AV) 1.5 A Peak forward surge current single sine-wave superimposed on rated load IFSM 60 A I2t 15 A2 s TJ, TSTG - 55 to + 150 C Rating for fusing (t < 8.3 ms) Operating junction and storage temperature range ELECTRICAL CHARACTERISTICS (TA = 25 C unless otherwise noted) PARAMETER TEST CONDITIONS Maximum instantaneous forward voltage drop per diode 0.75 A VF 1.00 V Maximum DC reverse current at rated DC blocking voltage per diode TA = 25 C TA = 125 C IR 5.0 300 A Document Number: 89303 Revision: 16-Nov-11 SYMBOL G2SBA20 G2SBA60 For technical questions within your region, please contact one of the following: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com G2SBA80 UNIT www.vishay.com 1 G2SBA20, G2SBA60, G2SBA80 Vishay General Semiconductor THERMAL CHARACTERISTICS (TA = 25 C unless otherwise noted) PARAMETER SYMBOL G2SBA20 G2SBA60 RJA RJC Typical thermal resistance G2SBA80 UNIT 40 12 C/W Note (1) Unit mounted on PCB with 0.5" x 0.5" (12 mm x 12 mm) copper pads and 0.375" (9.5 mm) lead length ORDERING INFORMATION (Example) PREFERRED P/N UNIT WEIGHT (g) PREFERRED PACKAGE CODE BASE QUANTITY DELIVERY MODE G2SBA60-M3/45 2.017 45 20 Tube G2SBA60-M3/51 2.017 51 400 Anti-static PVC tray RATINGS AND CHARACTERISTICS CURVES (TA = 25 C unless otherwise noted) 100 Instantaneous Forward Current (A) Average Forward Output (IF(AV)) 2.0 P.C.B. Mounting, TA 1.5 1.0 0.5 25 50 75 100 125 150 0.1 1.0 1.4 1.8 2.2 2.6 3.0 3.4 Temperature (C) Instantaneous Forward Voltage (V) Figure 1. Derating Curve Output Rectified Current Figure 3. Typical Forward Characteristics Per Diode 100 Instantaneous Reverse Current (A) 100 Peak Forward Surge Current (A) 1 0.01 0.6 0 0 10 80 60 40 20 1.0 Cycle TA = 125 C 10 1 0.1 TA = 25 C 0.01 0 1 10 100 0 20 40 60 80 100 Number of Cycles at 60 Hz Percent of Rated Peak Reverse Voltage (%) Figure 2. Maximum Non-Repetitive Peak Forward Surge Current Per Diode Figure 4. Typical Reverse Characteristics Per Diode www.vishay.com 2 For technical questions within your region, please contact one of the following: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com Document Number: 89303 Revision: 16-Nov-11 G2SBA20, G2SBA60, G2SBA80 Vishay General Semiconductor 100 Transient Thermal Impedance (C/W) Junction Capacitance (pF) 100 10 1 0.1 1 10 10 1 0.1 0.01 0.01 100 0.1 1 10 100 Reverse Voltage (V) t - Heating Time (s) Figure 5. Typical Junction Capacitance Per Diode Figure 6. Typical Transient Thermal Impedance PACKAGE OUTLINE DIMENSIONS in inches (millimeters) Case Type GBL 0.125 (3.17) x 45 Chamfer 0.825 (20.9) 0.815 (20.7) 0.421 (10.7) 0.411 (10.4) 0.080 (2.03) 0.060 (1.50) 0.098 (2.5) 0.075 (1.9) 0.718 (18.2) 0.682 (17.3) Lead Depth 0.022 (0.56) 0.018 (0.46) 0.095 (2.41) 0.080 (2.03) 0.098 (2.5) 0.075 (1.9) 0.050 (1.27) 0.040 (1.02) 0.210 (5.3) 0.190 (4.8) 0.040 (1.02) 0.030 (0.76) 0.022 (0.56) 0.018 (0.46) 0.140 (3.56) 0.128 (3.25) Polarity shown on front side of case, positive lead beveled corner Document Number: 89303 Revision: 16-Nov-11 For technical questions within your region, please contact one of the following: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com www.vishay.com 3 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Revision: 12-Mar-12 1 Document Number: 91000