GN (AGN) TESTING ULTRA-SMALL PACKAGE SLIM POLARIZED RELAY GN RELAYS (AGN) FEATURES 1. Compact slim body saves space Thanks to the small surface area of 5.7 mm x 10.6 mm .224 inch x .417 inch and low height of 9.0 mm .354 inch, the packaging density can be increased to allow for much smaller designs. 2. Outstanding surge resistance. Surge breakdown voltage between contacts and coil: 2,500 V 2x10 s (Telcordia) Surge breakdown voltage between open contacts: 1,500 V 10x160 s (FCC part 68) 3. The use of twin crossbar contacts ensures high contact reliability. AgPd contact is used because of its good sulfide resistance. Adopting lowgas molding material. Coil assembly molding technology which avoids generating volatile gas from coil. 4. Increased packaging density Due to highly efficient magnetic circuit design, leakage flux is reduced and changes in electrical characteristics from components being mounted close-together are minimized. This all means a packaging density higher than ever before. RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ 5. Nominal operating power: 140 mW 6. Outstanding vibration and shock resistance. Functional shock resistance: 750 m/s2 Destructive shock resistance: 1,000 m/s2 Functional vibration resistance: 10 to 55 Hz (at double amplitude of 3.3 mm .130 inch) Destructive vibration resistance: 10 to 55 Hz (at double amplitude of 5 mm .197 inch) 7. Sealed construction allows automatic washing. TYPICAL APPLICATIONS 1. Telephone switchboard 2. Telecommunications equipment 3. Measurement equipment 4. Consumer electronic and audio visual equipment ORDERING INFORMATION AGN 2 0 Contact arrangement 2: 2 Form C Operating function 0: Single side stable 1: 1 coil latching Type of operation 0: Standard type (B.B.M.) Terminal shape Nil: Standard PC board terminal A: Surface-mount terminal A type S: Surface-mount terminal S type Coil voltage (DC) 1H: 1.5V 03: 3V 4H: 4.5V 06: 6V 09: 9V 12: 12V 24: 24V Packing style Nil: Tube packing X: Tape and reel packing (picked from 1/2/3/4 pin side) Z: Tape and reel packing (picked from 5/6/7/8 pin side) All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. GN (AGN) TYPES 1. Standard PC board terminal Nominal coil voltage 1.5V DC 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC Single side stable Part No. AGN2001H AGN20003 AGN2004H AGN20006 AGN20009 AGN20012 AGN20024 1 coil latching Part No. AGN2101H AGN21003 AGN2104H AGN21006 AGN21009 AGN21012 AGN21024 Single side stable Part No. AGN2001H AGN20003 AGN2004H AGN20006 AGN20009 AGN20012 AGN20024 1 coil latching Part No. AGN2101H AGN21003 AGN2104H AGN21006 AGN21009 AGN21012 AGN21024 Standard packing: Tube: 50 pcs.; Case: 1,000 pcs. 2. Surface-mount terminal 1) Tube packing Nominal coil voltage 1.5V DC 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC : For each surface-mounted terminal identification, input the following letter. A type: A, S type: S Standard packing: Tube: 50 pcs.; Case: 1,000 pcs. 2) Tape and reel packing Nominal coil voltage Single side stable Part No. AGN2001HZ AGN20003Z AGN2004HZ AGN20006Z AGN20009Z AGN20012Z AGN20024Z 1.5V DC 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC 1 coil latching Part No. AGN2101HZ AGN21003Z AGN2104HZ AGN21006Z AGN21009Z AGN21012Z AGN21024Z : For each surface-mounted terminal identification, input the following letter. A type: A, S type: S Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs. Notes: 1. Tape and reel packing symbol "-Z" is not marked on the relay. "X" type tape and reel packing (picked from 1/2/3/4-pin side) is also available. 2. Please inquire if you require a relay, between 1.5 and 24 V DC, with a voltage not listed. RATING 1. Coil data 1) Single side stable type Nominal coil voltage Pick-up voltage (at 20C 68F) Drop-out voltage (at 20C 68F) Nominal operating current [10%] (at 20C 68F) Coil resistance [10%] (at 20C 68F) Nominal operating power Max. allowable voltage (at 20C 68F) 140mW 150%V of nominal voltage 1.5V DC 93.8mA 16 3V DC 4.5V DC 6V DC 9V DC 12V DC 46.7mA 31mA 23.3mA 15.5mA 11.7mA 64.2 145 257 579 1,028 9.6mA 2,504 230mW 120%V of nominal voltage Nominal operating current [10%] (at 20C 68F) Coil resistance [10%] (at 20C 68F) Nominal operating power Max. allowable voltage (at 20C 68F) 1.5V DC 66.7mA 22.5 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC 33.3mA 22.2mA 16.7mA 11.1mA 8.3mA 5.0mA 90 202.5 360 810 1,440 4,800 100mW 150%V of nominal voltage 75%V or less of nominal voltage* (Initial) 10%V or more of nominal voltage* (Initial) 24V DC 2) 1 coil latching type Nominal coil voltage Set voltage (at 20C 68F) 75%V or less of nominal voltage* (Initial) Reset voltage (at 20C 68F) 75%V or less of nominal voltage* (Initial) *Pulse drive (JIS C 5442-1996) All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. 120mW GN (AGN) 2. Specifications Characteristics Contact Rating Item Arrangement Initial contact resistance, max. Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Min. switching capacity (Reference value)*1 Single side stable Nominal operating power 1 coil latching Specifications 2 Form C Max. 100 m (By voltage drop 6 V DC 1A) Stationary contact: AgPd+Au clad Movable contact: AgPd 1 A 30 V DC, 0.3 A 125 V AC 30 W (DC), 37.5 V A (AC) 110 V DC, 125 V AC 1A 10A 10 mV DC 140mW (1.5 to 12 V DC), 230mW (24 V DC) 100mW (1.5 to 12 V DC), 120mW (24 V DC) Min. 1,000M (at 500V DC) Measurement at same location as "Initial breakdown voltage" section. 750 Vrms for 1min. (Detection current: 10mA) 1,500 Vrms for 1min. (Detection current: 10mA) 1,000 Vrms for 1min. (Detection current: 10mA) 1,500 V (10x160s) (FCC Part 68) 2,500 V (2x10s) (Telcordia) Max. 50C (By resistive method, nominal voltage applied to the coil; contact carrying current: 1A.) Max. 4 ms [Max. 4 ms] (Nominal voltage applied to the coil, excluding contact bounce time.) Max. 4 ms [Max. 4 ms] (Nominal voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10s.) Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10s.) 10 to 55 Hz at double amplitude of 5 mm Min. 5 x 107 (at 180 cpm) Min. 105 (1 A 30 V DC resistive), 105 (0.3 A 125 V AC resistive) (at 20 cpm) Ambient temperature: -40C to +85C -40F to +185F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 cpm Approx. 1 g .035 oz Insulation resistance (Initial) Between open contacts Between contact and coil Between contact sets Between open contacts Between contacts and coil Breakdown voltage (Initial) Electrical characteristics Surge breakdown voltage (Initial) Temperature rise (at 20C 68F) Operate time [Set time] (at 20C 68F) Release time [Reset time] (at 20C 68F) Mechanical characteristics Expected life Conditions Functional Destructive Functional Vibration resistance Destructive Mechanical Electrical Shock resistance Conditions for operation, transport and storage*2 Max. operating speed (at rated load) Unit weight Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT. REFERENCE DATA 1. Max. switching capacity 2. Life curve 3. Mechanical life Tested sample: AGN2004H, 15 pcs. Operating speed: 180 cpm 0.3 4 3.5 Pick-up voltage Max. 50 40 3 Voltage, V 1.0 No. of operations, x 104 Switching current, A 100 DC resistive load AC resistive load 30 DC 30V resistive load 20 Min. 2.5 2 Drop-out voltage Max. 1.5 Min. AC 125V resistive load 10 1 0.5 30 0 100 Contact voltage, V 0.2 0.4 0.6 0.8 1.0 0 0 1.2 10 30 50 No. of operations, x10 Switching current, A 4 4. Electrical life (1A 30V DC resistive load) 5. Coil temperature rise Tested sample: AGN2004H, 6 pcs. Operating speed: 20 cpm Tested sample: AGN2004H, AGN20024, 6 pcs. Point measured: Inside the coil Ambient temperature: Room temperature Change of contact resistance 100 90 90 80 70 Pick-up voltage Max. Min. 60 50 40 Drop-out voltage Max. 30 Min. 20 10 0 0 70 N.C. contact N.O. contact 80 70 60 50 X X 40 30 No. of operations, x10 10 4 4.5V DC type 24V DC type 60 50 1A 0A 40 1A 0A 30 20 20 10 10 5 Temperature rise, C 100 Contact resistance, m Ratio against the rated voltage, %V Change of pick-up and drop-out voltage 0 0 5 No. of operations, x10 10 0 4 All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. 100 110 120 130 140 150 Coil applied voltage, % GN (AGN) 6-(2). Operate and release time (with diode) 7. Ambient temperature characteristics Tested sample: AGN2004H, 6 pcs. Tested sample: AGN2004H, 6 pcs. Tested sample: AGN2004H, 6 pcs. Operate time Release time 2.5 Max. 2 Min. 1.5 1 Max. Min. 3 Operate and release time, ms Operate and release time, ms 3 Operate time Release time 2.5 Max. Drop-out voltage -40 -20 0 2 1.5 Min. Max. Min. Pick-up voltage 1 0.5 0.5 0 0 Rate of change, %V 6-(1). Operate and release time (without diode) 50 40 30 20 x x 10 20 40 60 80 100 -10 Ambient temperature, C -20 -30 -40 80 90 100 110 120 Coil applied voltage, %V 80 90 100 110 -50 120 Coil applied voltage, %V 9-(2). Influence of adjacent mounting Tested sample: AGN20012, 6 pcs. Tested sample: AGN20012, 6 pcs. Y 1,000m/s 2 Deenergized condition Energized condition X 1,000m/s2 Z 1,000m/s2 1,000m/s2 Z' 1,000m/s2 X' 1,000m/s2 Y' 10 5 ON ON Pick-up voltage 0 -5 ON -10 10 OFF 5 OFF Drop-out voltage 0 -5 -10 0 OFF 2 4 6 8 10 12 .079 .157 .236 .315 .394 .472 Inter-relay distance , mm inch All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. Rate of change, %V Z X X' Rate of change, %V Z' Y Y' Rate of change, %V 9-(1). Influence of adjacent mounting Tested sample: AGN2004H Rate of change, %V 8. Malfunctional shock 10 5 ON Pick-up voltage 0 ON -5 ON -10 10 OFF 5 Drop-out voltage 0 -5 -10 0 OFF OFF 2 4 6 8 10 12 .079 .157 .236 .315 .394 .472 Inter-relay distance , mm inch GN (AGN) DIMENSIONS (Unit: mm inch) 1. PC board terminal External dimensions PC board pattern Schematic (Bottom view) Standard type Single side stable 7.60 .299 5.700.3 .224.012 10.600.3 .417.012 3.20 .126 0.400.1 .016.004 0.250.1 .010.004 2.200.15 .087.006 3.200.15 .126.006 (1.50) (.059) 3.200.15 .126.006 2 3 4 8 7 6 5 1 coil latching 0.85 dia. .033 dia. (Reset condition) 0.400.1 .016.004 (1.50) (.059) 0.250.1 .010.004 0.400.1 .016.004 (1.50) (.059) 5.30 .209 0.80 .031 7.400.3 .291.012 5.700.3 .224.012 10.600.3 .417.012 S type 3.10 .122 3.200.15 .126.006 2.200.15 .087.006 3.200.15 .126.006 8 7 6 5 1 2 3 4 2.20 .087 3.20 .126 (0.50) 9.000.3 (.020) .354.012 Max. 10.00 .394 2.25 .089 3.200.15 .126.006 2.200.15 .087.006 3.200.15 .126.006 5.700.3 .224.012 Schematic (Top view) Single side stable 2.20 .087 3.20 .126 (0.50) 9.000.3 (.020) .354.012 Max. 10.00 .394 0.250.1 .010.004 A type 1 coil latching 8 7 6 5 1 2 3 4 Direction indication Direction indication (Deenergized condition) (Reset condition) 7 6 5 (Deenergized condition) Tolerance: 0.1 .004 5.700.3 .224.012 10.600.3 .417.012 8 Direction indication Suggested mounting pad (Tolerance: 0.1 .004) Single side stable and 1 coil latching External dimensions Single side stable and 1 coil latching 2 3 4 Direction indication 2.20 .087 2. Surface-mount terminal Type 1 3.20 .126 (0.50) 9.000.3 (.020) .354.012 3.500.3 .138.012 1 All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. 4.45 .175 0.80 .031 GN (AGN) NOTES 5. Packing style 1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below. Orientation (indicates PIN No.1)stripe Stopper (green) Stopper (red) 2) Tape and reel packing (A type) (1)-1 Tape dimensions A mm inch Relay polarity bar (Z type) 4.00 .157 2.00 .079 1.50 +0.1 0 dia. dia. .059 +.004 0 0.40 .016 11.50 .453 1.75 .069 11.10 .437 10.700.2 .421.008 2.00 dia. .079 dia. GN relays 6. Automatic insertion To maintain the internal function of the relay, the chucking pressure should not exceed the values below. Chucking pressure in the direction A: 4.9 N {500gf} or less Chucking pressure in the direction B: 9.8 N {1 kgf} or less Chucking pressure in the direction C: 9.8 N {1 kgf} or less 16.00 .630 24.000.3 .945.012 8.00 .315 Tape coming out direction General tolerance 0.1 mm .004 inch .059 +.004 dia. 0 2.00 .079 4.00 2.0 dia. .157 .079 dia. 1.75 .069 10.700.2 .421.008 0.40 .016 11.50 .453 24.000.3 .945.012 11.10 .437 GN relays 16.00 .630 6.3 .248 Tape coming out direction General tolerance 0.1 mm .004 inch (2) Dimensions of plastic peel mm inch 210.8 dia. .827.031 dia. 2.00.5 .079.020 *1001 dia. 3.937.039 dia. *3702 dia. 14.567.079 dia. 130.2 dia. .512.008 dia. 24.4 +2 0 .961 +.079 0 B Please chuck the portion. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be avoided. (S type) (1)-2 Tape dimensions Relay polarity bar (Z type) 1.50 +0.1 0 dia. C ; ; ; ; ; 1. Coil operating power 1) As a general rule, only a pure DC power supply should be used for the coil drive. 2) To ensure proper operation, the voltage applied to both terminals of the coil should be 5% (at 20C 68F) the rated operating voltage of the coil. Also, be aware that the pick-up and drop-out voltages will fluctuate depending on the ambient temperature and operating conditions. 3) The ripple factor for the voltage applied to the coil should be less than 5%. 4) For set and reset latching relays, the rated operating voltage should be applied to the coil for 10 ms or more. 2. Coil connection When connecting coils, refer to the wiring diagram to prevent mis-operation or malfunction. 3. External magnetic field Since GN relays are highly sensitive polarized relays, their characteristics will be affected by a strong external magnetic field. Avoid using the relay under that condition. 4. Cleaning In automatic cleaning, cleaning with the boiling method is recommended. Avoid ultrasonic cleaning which subject the relay to high frequency vibrations. It may cause the contacts to stick. It is recommended that a fluorinated hydrocarbon or other alcoholic solvent be used. 2.00.2 .079.008 Note: Dimensions of items produced after December 2006 have changed as shown below. 1001 dia. 3.937.039 dia. 801 dia. 3.150.039 dia.; 3702 dia. 14.567.079 dia. 3802 dia. 14.961.079 dia. For Cautions for Use, see Relay Technical Information. All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd.