CSM_M16_DS_E_6_1
1
Indicator (Cylindrical 16-dia.)
M16
Cylindrical 16-dia. Indicator
Same basic design as the A16 Pushbutton Switch.
Refer to Safety Precautions for All Pushbutton Switches and
Safety Precautions on page 11.
List of Models
Appearance Model
Solder
terminals
Rectangular M16-J
Square M16-A
Round M16-T
Voltage-
reduction
lighting
M16-@
Screw-less
Clamp M16-@
M16
2
Model Number Structure
Model Number Legend ..... The model numbers used to order sets of Units are illustrated below. One set comprises the Display, Case,
Lamp, and Socket.
For information on combinations, refer to Ordering Information on the following pages.
Sets ................................. Select an Operation Unit Set (Operation Unit and Case) and a Socket Unit Set (Lamp and Socket Unit).
Lighted Models
Display Unit
Socket Unit Set with Voltage-reduction Lighting Socket Unit Set with Screw-less Clamp Connector
(1) (2) (3) (4) (5)
M 1 6 5 - T R - 24D - S
(2) Shape of Display
Symbol Shape
J Rectangular
A Square
T Round
(1) Degree of Protection
Symbol Protection
No
symbol IP40
5 IP65 oil-resistant
(4) Light Source
Voltage Reduction Unit (24-V Built-in LED)
Solder terminals are available only with 100-V models.
Screw-less clamp connectors are used for 200-V models.
Symbol
Type Operating voltage Rated voltage
5
Incandescent
lamp
5 VAC/VDC 6 VAC/VDC
12 12 VAC/VDC 14 VAC/VDC
24 24 VAC/VDC 28 VAC/VDC
5D
LED
5 ±5% VDC 5 VDC
12D 12 ±5% VAC/VDC 12 VAC/VDC
24D 24 ±5% VAC/VDC 24 VAC/VDC
Symbol
Type Operating voltage Rated voltage
T1 LED 100/110 VAC/VDC
110 VAC/VDC
T2 200/220 VAC/VDC
220 VAC/VDC
(5) Terminal Type
Symbol Terminal type
No symbol Solder terminals
S Screw-less Clamp
(3) Color of Display
Color illuminated models
are also available (see
page 4).
Order the parts separately.
Symbol Color
RRed
G Green
YYellow
PY Pure yellow
WWhite
PW Pure white
ABlue
Rectangular, Square, Round
Voltage-reduction
lighting
Lamp Lamp
M16
3
Ordering Information
Ordering as a Set ................................. The model numbers used to order sets of Units are given in the following tables. One set comprises
the Display, Case, Lamp, and Socket.
M16@-J (Rectangular) Models
Solder Terminal Models
* Enter the desired color symbol into the box in the model number.
M16@-A (Square) Models
Solder Terminal Models
* Enter the desired color symbol into the box in the model number.
M16@-T (Round) Models
Solder Terminal Models
Note: Neon lamps are not available with models that are ordered as a set. They must be ordered individually if required.
* Enter the desired color symbol into the box in the model number.
Appearance Degree of protection
Lighting IP40 IP65 oil-resistant Display color symbol *
Rectangular (M16-J)
LED without Voltage
Reduction Unit
5 VDC M16-J@-5D M165-J@-5D R: red
Y: yellow
G: green
A: blue
W: white
PY: pure yellow
PW: pure white
12 VAC/VDC M16-J@-12D M165-J@-12D
24 VAC/VDC M16-J@-24D M165-J@-24D
Incandescent lamp
5 VAC/VDC M16-J@-5 M165-J@-5 R: red
Y: yellow
G: green
A: blue
W: white
PY: pure yellow
12 VAC/VDC M16-J@-12 M165-J@-12
24 VAC/VDC M16-J@-24 M165-J@-24
Appearance Degree of protection
Lighting IP40 IP65 oil-resistant Display color symbol *
Square (M16-A) LED without Voltage
Reduction Unit
5 VDC M16-A@-5D M165-A@-5D R: red
Y: yellow
G: green
A: blue
W: white
PY: pure yellow
PW: pure white
12 VAC/VDC M16-A@-12D M165-A@-12D
24 VAC/VDC M16-A@-24D M165-A@-24D
Incandescent lamp
5 VAC/VDC M16-A@-5 M165-A@-5 R: red
Y: yellow
G: green
A: blue
W: white
PY: pure yellow
12 VAC/VDC M16-A@-12 M165-A@-12
24 VAC/VDC M16-A@-24 M165-A@-24
Appearance Degree of protection
Lighting IP40 IP65 oil-resistant Display color symbol *
Round (M16-T) LED without Voltage
Reduction Unit
5 VDC M16-T@-5D M165-T@-5D R: red
Y: yellow
G: green
A: blue
W: white
PY: pure yellow
PW: pure white
12 VAC/VDC M16-T@-12D M165-T@-12D
24 VAC/VDC M16-T@-24D M165-T@-24D
Incandescent lamp
5 VAC/VDC M16-T@-5 M165-T@-5 R: red
Y: yellow
G: green
A: blue
W: white
PY: pure yellow
12 VAC/VDC M16-T@-12 M165-T@-12
24 VAC/VDC M16-T@-24 M165-T@-24
Accessories, replacements, and tools: Refer to the A16.
Ratings and characteristics: Refer to the A16.
Dimensions: Refer to pages 9 to 10.
Individual models: Refer to pages 4 to 7.
(The Display, Lamp, Case, and Switch can be ordered separately.)
M16
4
Ordering Information
Ordering Individually..........................Displays, Cases, Lamps, and Sockets can be ordered separately. Combinations that are not
available as sets can be created using individual parts. Also, store the parts as spares for
maintenance and repairs.
Lighted Models
For colored illumination, order the Display, Case, Lamp, and Socket Unit separately.
Display (Refer to page 6.)
Case (Refer to page 7.)
Lamp (Refer to page 7.)
Socket (Refer to page 7.)
Rectangular Square Round
Note: Use IP40 Displays in combination with IP40
Sockets and use IP65 Displays in
combination with IP65 Sockets.
The Display has a legend plate built in.
Note: Display Units, which are combinations of Displays and
Cases, are also available.
LED Incandescent Lamp
Note: Socket Units, which are combinations of Lamps and Sockets, are
also available.
Solder Terminals
(Without Voltage Reduction Unit)
M16
5
Ordering Information
Sets.................................. Sets that combined a Display and Cases are also available.
Display Set
Insert one of the following symbols into the box in the model number.
* Use this pushbutton color if the illumination color of the LED is white or pure
white.
Appearance Classification Model
IP40
Rectangular (2-way guard) A16-J@M
Square (2-way guard) A16-A@M
Round (projecting model) A16-T@M
Oil-resistant IP65
Rectangular (2-way guard) A165-J@M
Square (2-way guard) A165-A@M
Round (projecting model) A165-T@M
Symbol Color Remarks
RRed
LED and incandes-
cent lamps
YYellow
PY Pure yellow
ABlue
WWhite*
GY Green LED only
G Green Incandescent only
Socket Unit Sets with Incandescent Lamps Socket Unit Sets with LEDs
Appearance Classification Model
5 V
Solder terminals
M16-5
12 V M16-12
24 V M16-24
Appearance Classification Model
Solder terminals
M16-@
1 -@
2
I
nsert sym
b
o
l
s
i
nto t
h
e
b
oxes w
i
t
h
c
i
rc
l
e
d
num
b
ers.
@
1
@
2
Symbol Color
RRed
YYellow
ABlue
WWhite
G Green
Symbol Type Operating
voltage
5D
LED
5 VDC
12D 12 VAC/VDC
24D 24 VAC/VDC
Socket Unit Sets with Voltage-reduction Lighting (Solder Terminals)
Note: The LED has 24-VAC/VDC circuit built in.
Socket Unit Sets with Screw-less Clamp Connectors
Note: 1. The LED built into the 100-V model is 24 VAC/VDC.
2. The LED built into the 200-V model is high-intensity 24 VAC/VDC.
Appearance Classification Model
100/110 VAC/VDC M16-@
1 -T1
Appearance Classification Model
Display
No voltage-reduction lighting M16-@
1 -@
2 -S
Voltage-reduc-
tion lighting
(See note.)
100/110 VAC/VDC M16-@
1 -T1-S
200/220 VAC/VDC
M16-@
1 -T2-S
M16
6
Ordering Information
Ordering Individually..........................Displays, Cases, Lamps, and Sockets can be ordered separately. Combinations that are not
available as sets can be created using individual parts. Also, store the parts as spares for
maintenance and repairs.
Display
For LED-lighted Models
Incandescent Lamps (With the exception of green, the Units are the same as for LEDs.)
Sealing IP40 IP65 oil-resistant
Appearance
Color of Display
Rectangular Square Round Rectangular Square Round
Red A16L-JR A16L-AR A16L-TR A165L-JR A165L-AR A165L-TR
Yellow A16L-JY A16L-AY A16L-TY A165L-JY A165L-AY A165L-TY
Pure yellow A16L-JPY A16L-APY A16L-TPY A165L-JPY A165L-APY A165L-TPY
Green A16L-JGY A16L-AGY A16L-TGY A165L-JGY A165L-AGY A165L-TGY
White A16L-JW A16L-AW A16L-TW A165L-JW A165L-AW A165L-TW
Blue A16L-JA A16L-AA A16L-TA A165L-JA A165L-AA A165L-TA
Sealing IP40 IP65 oil-resistant
Appearance
Color of Display
Rectangular Square Round Rectangular Square Round
Red A16L-JR A16L-AR A16L-TR A165L-JR A165L-AR A165L-TR
Yellow A16L-JY A16L-AY A16L-TY A165L-JY A165L-AY A165L-TY
Pure yellow A16L-JPY A16L-APY A16L-TPY A165L-JPY A165L-APY A165L-TPY
Green A16L-JG A16L-AG A16L-TG A165L-JG A165L-AG A165L-TG
White A16L-JW A16L-AW A16L-TW A165L-JW A165L-AW A165L-TW
Blue A16L-JA A16L-AA A16L-TA A165L-JA A165L-AA A165L-TA
Ordering set combinations: Refer to page 3. Accessories, replacements, and tools: Refer to the A16.
Ratings and characteristics: Refer to the A16.
Dimensions: Refer to pages 9 to 10.
M16
7
Ordering Information
Ordering Individually ......................... Displays, Cases, Lamps, and Sockets can be ordered separately. Combinations that are not
available as sets can be created using individual parts. Also, store the parts as spares for
maintenance and repairs.
Lamp
LED
* Use the white LED when the required illumination color is white or pure yellow.
Incandescent Lamp
Case
Socket
Operating voltage High intensity
Color 5 VDC 12 VAC/VDC 24 VAC/VDC
Red A16-5DSR A16-12DSR A16-24DSR
Yellow A16-5DSY A16-12DSY A16-24DSY
Green A16-5DSG A16-12DSG A16-24DSG
White *A16-5DSW A16-12DSW A16-24DSW
Blue A16-5DA A16-12DA A16-24DA
Pure white A16-5DPW A16-12DPW A16-24DPW
Appearance Operating voltage Model
5 VAC/VDC A16-5
12 VAC/VDC A16-12
24 VAC/VDC A16-24
Appearance Classification Model number
IP40
Rectangular A16-CJM
Square A16-CAM
Round A16-CTM
IP65 oil-resistant
Rectangular A165-CJM
Square A165-CAM
Round A165-CTM
Appearance Classification Model number
Solder terminals M16-0
PCB terminals M16-0P
Screw-Less Clamp M16-S
Solder terminals
Voltage-
reduction
lighting
100 V M16-T1
Screw-less Clamp
100 V M16-T1-S
200 V M16-T2-S
Solder terminals
Ordering set combinations: Refer to page 3. Accessories, replacements, and tools: Refer to the A16.
Ratings and characteristics: Refer to the A16.
Dimensions: Refer to pages 9 to 10.
M16
8
Specifications
Approved Standard Ratings
UL, cUL (File No. E76675)
LED: 24 VDC max.
Incandescent lamp: 24 VDC/VAC max.
Note: Certification has been obtained for the Socket Unit.
For detailed information on individual products that have received certification, consult your supplier.
Ratings
Super-bright LED
Incandescent Lamp
Characteristics
Screw-less Clamp
Ambient operating
temperature
10
°
C to 55
°
C (with no icing or condensation)
Ambient operating
humidity
35% to 85%RH
Ambient storage
temperature
25
°
C to 65
°
C (with no icing or condensation)
Rated voltage Rated current Operating voltage Built-in limiting resistance
5 VDC
8 mA
5 VDC ±5% Red, yellow, white: 300
Green, blue, pure white: 160
12 VAC/VDC
12 VAC/VDC
±
5%
Red, yellow, white: 1 k
Green, blue, pure white: 910
24 VAC/VDC
24 VAC/VDC
±
5%
2.4 k
Rated voltage Rated current Operating voltage
6 VAC/VDC
60 mA
5 VAC/VDC
14 VAC/VDC 40 mA
12 VAC/VDC
28 VAC/VDC 24 mA
24 VAC/VDC
Item Type Screw-less Clamp
Recommended wire size 0.5 mm2 twisted wire or 0.8 mm-dia. solid wire
Usable wires
and tensile
strength
Twisted wire 0.3 mm20.5 mm20.75 mm21.25 mm2
Solid wire 0.5 mm dia. 0.8 mm dia. 1.0 mm dia. ---
Tensile strength 10 N 20 N 30 N 40 N
Length of exposed wire 10 ±1 mm
Compliant standards JIS C 2811 Terminal Blocks for Industrial Use
M16
9
Dimensions
(Refer to the A16 for details of panel cutout dimensions.) (Unit: mm)
18 15.1
21
24
4
10.8
6
M16×1
4.85
Lamp terminals
Lock ring
Mounting nut
18 dia.
14.6 dia.
21.1
28.5
9.3
Packing (t0.5)
(for oil-resistant IP65 only)
Rectangular
M16@-J
Solder terminals
18 15.1
15.1
18
4
10.8
6
M16×1
4.85
Lamp terminals
Lock ring
Mounting nut
18 dia.
14.6 dia.
21.1
28.5
9.3
Packing (t0.5)
(for oil-resistant IP65 only)
Square
M16@-A
Solder terminals
18
18
4
10.8
6
M16×1
4.85
Lamp terminals
Lock ring
Mounting nut
18 dia.
14.6 dia.
21.1
28.5
9.3
Packing (t0.5)
(for oil-resistant IP65 only)
15.1 dia.
18 dia.
Round
M16@-T
Solder terminals
2.6
Terminal Hole Dimensions
0.9
1.5
2.8
14.6 dia.
4
10.8
18 dia.
Lamp terminals
M16
10
Dimensions (Unit: mm)
Case
Operation Unit
9.5 21.1
Marking face
189.8
0.5
Direction-indication arrow
M16×1
42.7
50.1
(22.4)
24
18
21
15.1
20.6
10.86
4
16.68.8
Socket
Mounting ring
Lock ring
Packing (t0.5)
(for oil-resistant IP65 only)
2.8
24 min.
23 min.
16+ 0.2
0
dia.
Panel Cutouts
Rectangular
M16@-J@-T1
Voltage-reduction lighting,
solder terminals
Mounting ring
Lock ringSocket dismounting lever
Packing (t0.5)
(for oil-resistant IP65 only)
27.4(31.7) 23.5
23.924
9.5
6
48.9
21
15.1
24
18
M16×1
4
10.8
2
25 min.
33 min.
16+ 0.2
0
dia.
Panel Cutouts
Rectangular
M16@-J@-S
Screw-less Clamp
M16
11
Dimensions (All units are in millimeters unless otherwise indicated.)
Terminal Arrangement
Accessories, Replacements, and Tools
The accessories, replacements, and tools are also used with the A16 Pushbutton Switch. Refer to the A16 datasheet.
Safety Precautions
Refer to Safety Precautions for All Pushbutton Switches and Safety Precautions for the A16.
Mounting
When mounting the Case onto the Socket Unit, ensure that the
orientation is correct. Perform mounting with the dimple on the
Case and the TOP mark on the Socket Unit facing in the same
direction.
Wiring
When using stranded wire, gather the ends of the strands together
before wiring.
When wiring, insert the wire until it comes into contact with
something. After wiring is completed, pull on the wires to confirm
that they are connected securely.
After wiring, ensure that continuous pressure is not applied to the
terminals.
Refer to internal connections diagrams and confirm the terminal
numbers before performing wiring.
Screw-less Clamps
Mounting Procedure
1. Strip a length of 10 mm off the end of the wire (allowable range:
10±1 mm).
2. Bunch wire strands together and straighten them.
3. Insert the wire into the insertion hole while pressing the release
button at the side of the hole. (Using a precision screwdriver is
recommended.)
4. Let go of the release button to lock the wire into place.
5. After locking, pull on the wire gently to confirm that it is securely
locked.
Removing Procedure
1. Remove wires by pulling them while pressing the release button.
Note: When reusing wires that have already been locked, cut off the end of the
wire and strip the wire again before using.
Solder Terminals Screw-less Clamp Voltage-reduction Lighting
L +
L -
The L+ is not shown on the Socket Unit.
(BOTTOM VIEW)
-
+
+
(BOTTOM VIEW)
Side with TOP indicated
-
+
+
Red
Black
Side with TOP indicated
-
+
+
(BOTTOM VIEW)
Models with voltage-reduction lighting have a
circuit to reduce voltage built in.
Precautions for Correct Use
Socket Unit
TOP mark
Case
dimple
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2011.1
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2011 All Right Reserved.