Indicator (Cylindrical 16-dia.) M16 CSM_M16_DS_E_6_1 Cylindrical 16-dia. Indicator * Same basic design as the A16 Pushbutton Switch. Refer to Safety Precautions for All Pushbutton Switches and Safety Precautions on page 11. List of Models Appearance Solder terminals Model Rectangular M16-J Square M16-A Round M16-T Voltagereduction lighting M16-@ Screw-less Clamp M16-@ 1 M16 Model Number Structure Model Number Legend ..... The model numbers used to order sets of Units are illustrated below. One set comprises the Display, Case, Lamp, and Socket. For information on combinations, refer to Ordering Information on the following pages. (1) (2) (3) (4) (5) M 1 6 5 - T R - 24D - S (5) Terminal Type Symbol No symbol S Terminal type Solder terminals Screw-less Clamp (1) Degree of Protection (2) Shape of Display (3) Color of Display (4) Light Source Symbol No symbol 5 Protection Symbol IP40 J A T IP65 oil-resistant Shape Rectangular Square Round Symbol R G Y PY W PW A Symbol Type Operating voltage Rated voltage 5 VAC/VDC 6 VAC/VDC 5 Incandescent 12 12 VAC/VDC 14 VAC/VDC lamp 24 24 VAC/VDC 28 VAC/VDC 5D 5 5% VDC 5 VDC 12D LED 12 5% VAC/VDC 12 VAC/VDC 24D 24 5% VAC/VDC 24 VAC/VDC Color Red Green Yellow Pure yellow White Pure white Blue Voltage Reduction Unit (24-V Built-in LED) * Color illuminated models are also available (see page 4). * Order the parts separately. Symbol T1 T2 Type LED Operating voltage Rated voltage 100/110 VAC/VDC 110 VAC/VDC 200/220 VAC/VDC 220 VAC/VDC * Solder terminals are available only with 100-V models. * Screw-less clamp connectors are used for 200-V models. Sets ................................. Select an Operation Unit Set (Operation Unit and Case) and a Socket Unit Set (Lamp and Socket Unit). Display Unit Rectangular, Square, Round Lighted Models Socket Unit Set with Voltage-reduction Lighting Voltage-reduction lighting Lamp Socket Unit Set with Screw-less Clamp Connector Lamp 2 M16 Ordering Information Ordering as a Set ................................. The model numbers used to order sets of Units are given in the following tables. One set comprises the Display, Case, Lamp, and Socket. M16@-J (Rectangular) Models Solder Terminal Models Appearance Degree of protection IP40 IP65 oil-resistant M16-J@-5D M165-J@-5D LED without Voltage 12 VAC/VDC Reduction Unit M16-J@-12D M165-J@-12D 24 VAC/VDC M16-J@-24D M165-J@-24D 5 VAC/VDC M16-J@-5 M165-J@-5 12 VAC/VDC M16-J@-12 M165-J@-12 24 VAC/VDC M16-J@-24 M165-J@-24 Lighting 5 VDC Rectangular (M16-J) Incandescent lamp Display color symbol * R: red Y: yellow G: green A: blue W: white PY: pure yellow PW: pure white R: red Y: yellow G: green A: blue W: white PY: pure yellow * Enter the desired color symbol into the box in the model number. M16@-A (Square) Models Solder Terminal Models Appearance Degree of protection IP40 IP65 oil-resistant M16-A@-5D M165-A@-5D LED without Voltage 12 VAC/VDC Reduction Unit M16-A@-12D M165-A@-12D 24 VAC/VDC M16-A@-24D M165-A@-24D 5 VAC/VDC M16-A@-5 M165-A@-5 12 VAC/VDC M16-A@-12 M165-A@-12 24 VAC/VDC M16-A@-24 M165-A@-24 Lighting 5 VDC Square (M16-A) Incandescent lamp Display color symbol * R: red Y: yellow G: green A: blue W: white PY: pure yellow PW: pure white R: red Y: yellow G: green A: blue W: white PY: pure yellow * Enter the desired color symbol into the box in the model number. M16@-T (Round) Models Solder Terminal Models Appearance Degree of protection Lighting 5 VDC IP40 IP65 oil-resistant M16-T@-5D M165-T@-5D LED without Voltage 12 VAC/VDC Reduction Unit M16-T@-12D M165-T@-12D 24 VAC/VDC M16-T@-24D M165-T@-24D 5 VAC/VDC M16-T@-5 M165-T@-5 12 VAC/VDC M16-T@-12 M165-T@-12 24 VAC/VDC M16-T@-24 M165-T@-24 Round (M16-T) Incandescent lamp Display color symbol * R: red Y: yellow G: green A: blue W: white PY: pure yellow PW: pure white R: red Y: yellow G: green A: blue W: white PY: pure yellow Note: Neon lamps are not available with models that are ordered as a set. They must be ordered individually if required. * Enter the desired color symbol into the box in the model number. Individual models: Refer to pages 4 to 7. (The Display, Lamp, Case, and Switch can be ordered separately.) Accessories, replacements, and tools: Refer to the A16. Ratings and characteristics: Refer to the A16. Dimensions: Refer to pages 9 to 10. 3 M16 Ordering Information Ordering Individually ..........................Displays, Cases, Lamps, and Sockets can be ordered separately. Combinations that are not available as sets can be created using individual parts. Also, store the parts as spares for maintenance and repairs. Display (Refer to page 6.) Rectangular Square Round Note: Use IP40 Displays in combination with IP40 Sockets and use IP65 Displays in combination with IP65 Sockets. The Display has a legend plate built in. Case (Refer to page 7.) Note: Display Units, which are combinations of Displays and Cases, are also available. Lighted Models Lamp (Refer to page 7.) LED Incandescent Lamp Socket (Refer to page 7.) Solder Terminals (Without Voltage Reduction Unit) Note: Socket Units, which are combinations of Lamps and Sockets, are also available. * For colored illumination, order the Display, Case, Lamp, and Socket Unit separately. 4 M16 Ordering Information Sets.................................. Sets that combined a Display and Cases are also available. Display Set Appearance Classification IP40 Oil-resistant IP65 Model Rectangular (2-way guard) A16-J@M Square (2-way guard) A16-A@M Round (projecting model) A16-T@M Rectangular (2-way guard) A165-J@M Square (2-way guard) A165-A@M Round (projecting model) A165-T@M Insert one of the following symbols into the box in the model number. Symbol R Y PY A W GY G Color Red Yellow Pure yellow Blue White* Green Green Remarks LED and incandescent lamps LED only Incandescent only * Use this pushbutton color if the illumination color of the LED is white or pure white. Socket Unit Sets with Incandescent Lamps Appearance Classification 5V Socket Unit Sets with LEDs Model Appearance Classification Model M16-5 12 V Solder terminals 24 V M16-12 1 -@ 2 M16-@ Solder terminals M16-24 Socket Unit Sets with Voltage-reduction Lighting (Solder Terminals) Appearance Classification Model Insert symbols into the boxes with circled numbers. 1 @ Symbol 100/110 VAC/VDC 1 -T1 M16-@ Note: The LED has 24-VAC/VDC circuit built in. Socket Unit Sets with Screw-less Clamp Connectors Appearance Classification No voltage-reduction lighting Display Model 1 -@ 2 -S M16-@ 1 -T1-S Voltage-reduc- 100/110 VAC/VDC M16-@ tion lighting (See note.) 1 -T2-S 200/220 VAC/VDC M16-@ Color R Red Y Yellow A Blue W White G Green Symbol Type 2 @ 5D 12D 24D Operating voltage 5 VDC LED 12 VAC/VDC 24 VAC/VDC Note: 1. The LED built into the 100-V model is 24 VAC/VDC. 2. The LED built into the 200-V model is high-intensity 24 VAC/VDC. 5 M16 Ordering Information Ordering Individually ..........................Displays, Cases, Lamps, and Sockets can be ordered separately. Combinations that are not available as sets can be created using individual parts. Also, store the parts as spares for maintenance and repairs. Display For LED-lighted Models Sealing IP40 Rectangular Square IP65 oil-resistant Round Rectangular Square Round Appearance Color of Display Red A16L-JR A16L-AR A16L-TR A165L-JR A165L-AR A165L-TR Yellow A16L-JY A16L-AY A16L-TY A165L-JY A165L-AY A165L-TY Pure yellow A16L-JPY A16L-APY A16L-TPY A165L-JPY A165L-APY A165L-TPY Green A16L-JGY A16L-AGY A16L-TGY A165L-JGY A165L-AGY A165L-TGY White A16L-JW A16L-AW A16L-TW A165L-JW A165L-AW A165L-TW Blue A16L-JA A16L-AA A16L-TA A165L-JA A165L-AA A165L-TA Incandescent Lamps (With the exception of green, the Units are the same as for LEDs.) Sealing IP40 Rectangular Square IP65 oil-resistant Round Rectangular Square Round Appearance Color of Display Red A16L-JR A16L-AR A16L-TR A165L-JR A165L-AR A165L-TR Yellow A16L-JY A16L-AY A16L-TY A165L-JY A165L-AY A165L-TY Pure yellow A16L-JPY A16L-APY A16L-TPY A165L-JPY A165L-APY A165L-TPY Green A16L-JG A16L-AG A16L-TG A165L-JG A165L-AG A165L-TG White A16L-JW A16L-AW A16L-TW A165L-JW A165L-AW A165L-TW Blue A16L-JA A16L-AA A16L-TA A165L-JA A165L-AA A165L-TA Ordering set combinations: Refer to page 3. Accessories, replacements, and tools: Refer to the A16. Ratings and characteristics: Refer to the A16. Dimensions: Refer to pages 9 to 10. 6 M16 Ordering Information Ordering Individually ......................... Displays, Cases, Lamps, and Sockets can be ordered separately. Combinations that are not available as sets can be created using individual parts. Also, store the parts as spares for maintenance and repairs. Lamp LED Operating voltage Color Red Yellow Green White * Blue Pure white High intensity 5 VDC 12 VAC/VDC 24 VAC/VDC A16-5DSR A16-5DSY A16-5DSG A16-5DSW A16-5DA A16-5DPW A16-12DSR A16-12DSY A16-12DSG A16-12DSW A16-12DA A16-12DPW A16-24DSR A16-24DSY A16-24DSG A16-24DSW A16-24DA A16-24DPW * Use the white LED when the required illumination color is white or pure yellow. Incandescent Lamp Appearance Operating voltage 5 VAC/VDC 12 VAC/VDC Model A16-5 A16-12 24 VAC/VDC A16-24 Case Appearance Classification IP40 IP65 oil-resistant Model number Rectangular Square Round Rectangular Square A16-CJM A16-CAM A16-CTM A165-CJM A165-CAM Round A165-CTM Socket Appearance Classification Model number Solder terminals PCB terminals M16-0P Screw-Less Clamp M16-S Solder terminals Solder terminals M16-0 Screw-less Clamp Ordering set combinations: Refer to page 3. Voltagereduction lighting 100 V M16-T1 100 V M16-T1-S 200 V M16-T2-S Accessories, replacements, and tools: Refer to the A16. Ratings and characteristics: Refer to the A16. Dimensions: Refer to pages 9 to 10. 7 M16 Specifications Approved Standard Ratings UL, cUL (File No. E76675) LED: Incandescent lamp: 24 VDC max. 24 VDC/VAC max. Note: Certification has been obtained for the Socket Unit. For detailed information on individual products that have received certification, consult your supplier. Ratings Ambient operating temperature -10C to 55C (with no icing or condensation) Ambient operating humidity 35% to 85%RH Ambient storage temperature -25C to 65C (with no icing or condensation) Super-bright LED Rated voltage Rated current Operating voltage 5 VDC 5% 5 VDC 12 VAC/VDC 24 VAC/VDC 8 mA 12 VAC/VDC 5% 24 VAC/VDC 5% Built-in limiting resistance Red, yellow, white: 300 Green, blue, pure white: 160 Red, yellow, white: 1 k Green, blue, pure white: 910 2.4 k Incandescent Lamp Rated voltage 6 VAC/VDC 14 VAC/VDC 28 VAC/VDC Rated current 60 mA 40 mA 24 mA Operating voltage 5 VAC/VDC 12 VAC/VDC 24 VAC/VDC Characteristics Screw-less Clamp Item Type Screw-less Clamp Recommended wire size 0.5 mm2 twisted wire or 0.8 mm-dia. solid wire 0.3 mm2 0.5 mm2 0.75 mm2 1.25 mm2 Usable wires Twisted wire Solid wire 0.5 mm dia. 0.8 mm dia. 1.0 mm dia. --and tensile strength Tensile strength 10 N 20 N 30 N 40 N Length of exposed wire 10 1 mm Compliant standards JIS C 2811 Terminal Blocks for Industrial Use 8 M16 Dimensions (Refer to the A16 for details of panel cutout dimensions.) Rectangular M16@-J Solder terminals Packing (t0.5) (for oil-resistant IP65 only) M16x1 (Unit: mm) Square M16@-A Solder terminals Packing (t0.5) (for oil-resistant IP65 only) M16x1 14.6 dia. 18 dia. 14.6 dia. 18 dia. 4 4 10.8 21.1 28.5 15.1 9.3 4.85 Lamp terminals 10.8 6 6 9.3 18 Lamp terminals 21.1 28.5 4.85 18 15.1 21 24 15.1 Mounting nut Round M16@-T Solder terminals Mounting nut 18 Lock ring Lock ring Packing (t0.5) (for oil-resistant IP65 only) M16x1 18 dia. 15.1 dia. 14.6 dia. 18 dia. 10.8 4 4 Lamp terminals 10.8 6 9.3 Terminal Hole Dimensions 21.1 28.5 2.6 0.9 18 Lamp terminals 4.85 1.5 2.8 14.6 dia. 18 dia. 18 Mounting nut Lock ring 9 M16 Dimensions (Unit: mm) Rectangular M16@-J@-T1 Voltage-reduction lighting, solder terminals 50.1 42.7 9.5 6 21.1 10.8 4 Direction-indication arrow 0.5 M16x1 Case Panel Cutouts 9.8 18 Operation Unit 16+ 0.2 0 dia. 24 min. Marking face Packing (t0.5) Lock ring (for oil-resistant IP65 only) Mounting ring Socket 23 min. (22.4) 15.1 18 8.8 16.6 20.6 2.8 21 24 Rectangular M16@-J@-S Screw-less Clamp 2 9.5 6 48.9 10.8 4 24 M16x1 Socket dismounting lever Panel Cutouts 23.9 16+ 0.2 0 dia. 25 min. Lock ring Mounting ring 33 min. (31.7) 27.4 18 15.1 21 24 23.5 Packing (t0.5) (for oil-resistant IP65 only) 10 M16 Dimensions (All units are in millimeters unless otherwise indicated.) Terminal Arrangement Solder Terminals Screw-less Clamp (BOTTOM VIEW) Black Voltage-reduction Lighting (BOTTOM VIEW) (BOTTOM VIEW) Side with TOP indicated Side with TOP indicated - L+ L- - + + + + + + The L+ is not shown on the Socket Unit. Red Models with voltage-reduction lighting have a circuit to reduce voltage built in. Accessories, Replacements, and Tools The accessories, replacements, and tools are also used with the A16 Pushbutton Switch. Refer to the A16 datasheet. Safety Precautions Refer to Safety Precautions for All Pushbutton Switches and Safety Precautions for the A16. Precautions for Correct Use Mounting * When mounting the Case onto the Socket Unit, ensure that the orientation is correct. Perform mounting with the dimple on the Case and the TOP mark on the Socket Unit facing in the same direction. TOP mark dimple Case Screw-less Clamps Mounting Procedure 1. Strip a length of 10 mm off the end of the wire (allowable range: 101 mm). 2. Bunch wire strands together and straighten them. 3. Insert the wire into the insertion hole while pressing the release button at the side of the hole. (Using a precision screwdriver is recommended.) 4. Let go of the release button to lock the wire into place. 5. After locking, pull on the wire gently to confirm that it is securely locked. Removing Procedure Socket Unit Wiring * When using stranded wire, gather the ends of the strands together before wiring. * When wiring, insert the wire until it comes into contact with something. After wiring is completed, pull on the wires to confirm that they are connected securely. * After wiring, ensure that continuous pressure is not applied to the terminals. * Refer to internal connections diagrams and confirm the terminal numbers before performing wiring. 1. Remove wires by pulling them while pressing the release button. Note: When reusing wires that have already been locked, cut off the end of the wire and strip the wire again before using. 11 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved.