http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TEN 6N Series 6 Watt
Input Specifications
Input current at no load 12 Vin models: 40 mA typ.
24 Vin models: 20 mA typ.
48 Vin models: 10 mA typ.
Input current at full load 12 Vin, 3.3VDC models: 440 mA typ.
12 Vin other models: 610 mA typ.
24 Vin, 3.3VDC models: 220 mA typ.
24 Vin other models: 300 mA typ.
48 Vin, 3.3VDC models: 110 mA typ.
48 Vin other models: 150 mA typ.
Recommended input fuse (slow blow) 12 Vin models: 1500 mA
24 Vin models: 700 mA
48 Vin models: 350 mA
Start-up voltage / under voltage shut down 12 Vin models: 9.0 VDC / 8.5 VDC (or lower)
24 Vin models: 18 VDC / 16 VDC (or lower)
48 Vin models: 36 VDC / 35 VDC (or lower)
Surge voltage (1 sec. max.) 12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
Conducted noise internal filter to meet EN 55022 class A
Output Specifications
Voltage set accuracy ±2 %
Regulation – Input variation Vin min. to Vin max. 0.5 % max.
– Load variation 0 – 100 % single output models: 1.2 % max.
dual output models balanced load: 1.2 % max.
dual output models 50%/100% unbalanced load: 3.0 % max.
Minimum load not required
Temperature coefficient ±0.02 %/K
Ripple and noise (20 MHz Bandwidth) 80 mVp-p max.
Dynamic load response (change from 75 % to 100 % load) ±3 % peak variation typ.
300 μS response time typ.
Current limitation 145 % of Iout max. typ., constant power
Short circuit protection continuous, automatic recovery
Capacitive load 3.3 & 5.0 VDC models: 470 μF max.
12 & 15 VDC models: 100 μF max.
24 VDC models: 47 μF max.
dual output models: 100 μF max. (each output)
General Specifications
Temperature ranges – Operating –40°C to +85°C
– Case temperature +100°C max.
– Storage –50°C to +125°C
Derating 3.3 & 5.0 VDC models: 2.5 %/K above +60°C
other models: 3.3 %/K above +70°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >1 Mio. h
Isolation voltage (60 sec.) – Input/Output 1’500 VDC (functional insulation)
Isolation capacitance – Input/Output (100 KHz, 1 V) 1000 pF typ.
Isolation resistance – Input/Output (500 VDC) >1‘000 M Ohm
Switching frequency 330 kHz typ.