12 Power Electronics Systems - SEMISTACK 17-03-2004 © by SEMIKRON
Power Electronics Systems SEMISTACK
1) Currents are calculated for a forced air configuration without thermal stacking, heat sink for SKiiP 3 is PX16, with SKF16B fan.
First value: Maximal permanent current without overload; Second value: nominal current, with 150 % overload at 2 Hz (U/f constant)
Ratings are: Vdc = 350, 540 or 950 Vdc, switching frequency = 3 kHz, ambient temperature = 35 °C, Vac = 230, 400 or 690 VRMS sinus output current
2) Power rating is for a cos ϕ = 0,85 and constant nominal conditions
SEMISTACK® with SKiiP® 3
Mains voltage SKiiP Type Nominal current1) Power rating2)
VRMS AkW
400
SKiiP 1803 GB 123 810 / 680 475
SKiiP 2013 GB 123 900 / 800 530
SKiiP 2403 GB 123 990 / 845 580
690
SKiiP 1803 GB 172 570 / 485 580
SKiiP 2013 GB 172 640 / 555 650
SKiiP 2403 GB 172 680 / 590 690
Standard air range up to 700 kW without paralleling
Standard water range up to 1 MW without paralleling
Extremely high power density
Electrolytic or polypropylene capacitors
High reliability thanks to SKiiP technology
Improved protection features
Designed according to EN 50178
All SEMISTACKs can be manufactured for a wide range of current and power ratings and also cooling methods (natural, forced-air
or water), depending on customer-specific requirements. Please contact SEMIKRON for more information.
Modular SEMISTACK® using SKiiP® 3 to give 1/6th of a
4-Quadrant Converter (700 kW, 660 Arms) for wind generators up to 2 MW
SEMISTACK® using SKiiP® 3 for wind generators (detail view)
Options
Low inductance
busbar
DC filtering capacitors
Heat sinks
Thermal Management
•Fans
Drivers
Thermal switches