PCB Power Relay
Miniature Power Relay for
Switching 8 A
Low-profile height of 15 mm (approx. 60% the height of the Omron
G2R model).
Capable of switching with 8 A at 250 VAC despite its small size.
High sensitivity with 220mW power consumption.
Offers high insulation with insulation distance of 8 mm and impulse
withstand voltage of 10kV between coil and contacts.
Satisfies ambient operating temperature requirement of 85°C.
Standard model conforms to VDE standards.
RoHS Compliant
Application Examples
Control equipments
Characteristics
Note. The data given above are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop
method.
*2. Measurement conditions: The insulation resistance
was measured with a 500 VDC megohmmeter at the
same locations as the dielectric strength was
measured.
*3. Test conditions: With diode
*4. This value was measured at a switching frequency of
120 operations/min.
Contact resistance *1 100 m
Ω
max.
Operate time 15 ms max.
Release time 5 ms max.
Insulation resistance *2 1,000 M
Ω
min.
Dielectric
strength
Between
coil and
contacts
4,000 VAC, 50/60 Hz for 1 min
Between
contacts of
the same
polarity
1,000 VAC, 50/60 Hz for 1 min
Impulse withstand
voltage (between coil
and contacts)
10,000 V (1.2 x 50
μ
s)
Insulation
distance
Between
coil and
contacts
Clearance: 8 mm,
Creepage: 8 mm
Vibration
resistance
Destruction
10 to 55 to 10 Hz, 0.75 mm
single amplitude
(1.5 mm double amplitude)
Malfunction
10 to 55 to 10 Hz
NO: 0.75 mm single amplitude
(1.5 mm double amplitude)
NC: 0.4 mm single amplitude
(0.8 mm double amplitude)
Shock
resistance
Destruction
1,000 m/s
2
Malfunction
NO: 100 m/s
2
NC:: 50 m/s
2
Durability
Mechanical
10,000,000 operations min.
(at 36,000 operations/hr)
Electrical *3
50,000 operations min.
(8 A at 250 VAC, resistive load)
50,000 operations min.
(5 A at 30 VDC, resistive load)
(at 360 operations/hr under
rated load)
Failure rate (P level)
(reference value) *4 10 mA at 5 VDC
Ambient operating
temperature
-40
°
C to 85
°
C (with no icing or
condensation)
Ambient operating
humidity 5% to 85%
Weight Approx. 9 g
Model Number Legend
G6RN-@@
——
12
1. Number of Poles
1: 1-pole
2. Contact Form
None: SPDT (1c)
A: SPST-NO (1a)
Ordering Information
Ratings
Coil
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
*2. The operating characteristics are measured at a coil temperature of 23°C.
*3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Contacts
Classification Enclosure
rating Contact form Terminal shape Model Rated coil
voltage
Minimun
packing unit
Standard Fully sealed
SPST-NO (1a) PCB
terminals
G6RN-1A 5, 6, 12 VDC
20 pcs/tube
24 VDC
SPDT (1c) G6RN-1 5, 6, 12 VDC
24 VDC
Item
Rated voltage
Rated
current
(mA)
Coil
resistance
(Ω)
Must operate
voltage
(V)
Must release
voltage
(V)
Max.
voltage
(V)
Power
consumption
(mW)
% of rated voltage
5 VDC 43.9 114
70% max. 10% min. 150%
(at 23°C) Approx. 220
6 VDC 36.6 164
12 VDC 18.3 655
24 VDC 9.2 2,620
Load
Item Resistive load
Contact type Single
Contact material Ag-Alloy + gold plating
(Cd free)
Rated load 8 A at 250 VAC
5 A at 30 VDC
Rated carry
current 8 A
Max. switching
voltage 250 VAC, 30 VDC
Max. switching
current 8 A
Note. When ordering, add the rated coil voltage to the model number.
Example: G6RN-1A DC5
However, the notation of the coil voltage on the product case will be marked as @@VDC.
Rated coil voltage
2
G6RN PCB Power Relay
G
6
R
N
Engineering Data
Dimensions
Maximum Switching Capacity Durability Ambient Temperature vs.
Maximum Coil Voltage
Note. The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
Ambient Temperature vs.
Maximum Coil Voltage
Shock Malfunction
G6RN-1
0 3 5 10 30 50 100 250 500
Switching current (A)
Switching Voltage (V)
50
30
10
8
5
3
1
0.5
0.3
0.1
DC resistive load AC resistive load
100
50
30
10
5
3
1
0 2 4 6 8 10
Durability (x 104 operations)
Switching Current (A)
250 VAC resistive load
30 VDC resistive load
200
180
160
150
140
130
120
110
100
80
0
-40 20 23 30 40 50 60 70 80 90 100
Maximum coil voltage (%)
Ambient Temperature (°C)
100
80
60
40
20
0
-40 -20 0 20 40 60 80 100
Operate/Release voltage (percentage of rated value) (%)
Ambient Temperature (°C)
Must operate voltage
Must release voltage
Sample:
G6RN-1 12 VDC
Number of Relays:
5 pcs
max.
min.
X
max.
min.
X
Z'
Z
Unit: m/s
2
Y
Y'
X
X'
1,000
1,000
1,000
1,0001,000
1,000
contact A
contact B 88.2
Z
Z'
Shock direction
Y
Y'
XX'
Sample: G6RN-1 24 VDC
Number of Relays: 5 pcs
Test conditions: The value at which
malfunction occurred was measured
after applying shock to the test piece 3
times each in 6 directions along 3 axes.
Standard value: 100m/s2 at contact A,
50m/s2 at contact B
28.5
±0.5
10
±0.5
15
±0.5
3.2
3.219
3.5
7.62
0.5
21
453
(1.19)
7.62
±0.1
Five, 1.3-dia. holes
(1.19)
(1.5)
(1.6)
19
±0.1
3.2
±0.1
3.2
±0.1
21
53
28.5±0.5 10±0.5
15±0.5
19 5.1
3.5
7.62
0.5
(1.19)
(1.19)
(2.8)(1.6)
Four, 1.3-dia. holes
7.62±0.1
19±0.1
5.1±0.1
3
G6RN PCB Power Relay
G
6
R
N
Approved Standards
The rated values approved by each of the safety standards may be different from the performance characteristics individually defined
in this catalog.
UL Recognized (File No. E41515)
CSA Certified (File No. 31928)
EN/TÜV Certified (Certificate No. 6135)
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
Model Number of
poles Coil ratings Contact ratings Number of test
operations
G6RN-1 1 5 to 24 VDC 8 A, 250 VAC 85°C
8 A, 30 VDC 85°C 6,000
Model Number of
poles Coil ratings Contact ratings Approved switching
operations
G6RN-1
G6RN-1A 1 5, 6, 12, 24 VDC 8 A, 250 VAC (Resistive)
85°C 10,000
Creepage distance 8 mm
Clearance distance 8 mm
Insulation material group IIIa
Rated Insulation voltage 250 V
Pollution degree 2
Rated voltage system 250 V
Overvoltage category III
Tracking Index of relay base PTI 250 V min. (housing parts)
Flammability class according to UL94 V-0
Ball pressure test (IEC 60695-10-2) 160°C
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. J182-E1-04
1116(0207)(O)
Note: Do not use this document to operate the Unit.