180
HY-RELAYS
Non-polarized
1 Form C Relay
mm inch
7.4
.291
10.1
.398
12
.472
FEATURES
• High sensitivity: 150 mW/200 mW
• A wide range of ambient temperature: –40
°
C to +70
°
C –40
°
F to +158
°
F
• Sealed construction
• Rating: 1 A 30 V DC
SPECIFICATIONS
Contact
Coil
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section
*
2
Detection current: 10mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10
µ
s
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10
µ
s
*
7
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)
Characteristics (at 25
°
C 77
°
F, 50% Relative humidity)
Arrangement 1 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) 100 m
Ω
Contact material Gold-clad silver
Rating
(resistive)
Nominal switching capacity 1 A 30 V DC
Max. switching power 30 W
Max. switching voltage 60 V DC
Max. switching current 1 A
Max. carrying current 2 A
Expected life
(min. operations)
Mechanical (at 180 cpm) 10
7
Electrical (at 20 cpm)
1 A 30 V DC 10
5
Nominal operating
power Standard type 200 mW
High sensitivity type 150 mW
Max. operating speed 20 cpm (at nominal voltage)
Initial
insulation
resistance*
1
Between contacts Min. 100 M
Ω
at 500 V DC
Between contact and
coil Min. 100 M
Ω
at 500 V DC
Initial
breakdown
voltage*
2
Between open
contacts 500 Vrms
Between contacts and
coil 1,000 Vrms
Operate time*
3
(at nominal voltage) Max. 5 ms (approx. 2 ms)
Release time (without diode)*
3
(at nominal voltage) Max. 4 ms (approx. 1 ms)
Temperature rise at nominal voltage
Contact carrying current 1 A at 20
°
CMax. 50
°
C
Shock resistance Functional*
4
Min. 98 m/s
2
(10 G)
Destructive*
5
Min. 980 m/s
2
(100 G)
Vibration resistance Functional*
6
58.8 m/s
2
{6 G}, 10 to 55 Hz
at double amplitude of 1 mm
Destructive 117.6 m/s
2
{12 G}, 10 to 55 Hz
at double amplitude of 2 mm
Conditions for opera-
tion, transport and
storage*
7
(Not freez-
ing and condensing
at low temperature)
Ambient
temp. –40
°
C to +70
°
C
–40
°
F to +158
°
F
Humidity 5 to 85% R.H.
Unit weight 1.8 g .063 oz
TYPICAL APPLICATIONS
• Automotive: Switching to small motor
1) Automirrow controller
2)Retractable head light controller
• Push button device: Dial pulsing
• Low-voltage signal switching and motor
control of small home appliances such as
portable video tape recorders and audio
devices.
• Operating of dish-control motors for PCs
and word processors
ORDERING INFORMATION
1Ex. HY Z
Contact arrangement Sensitivity Coil voltage (DC)
Nil: High sensitivity 150 mW
Z: Standard 200 mW
1: 1 Form C 1.5, 3, 4.5, 5, 6, 9, 12, 24 V
Standard packing: Carton: 100 pcs. Case 500 pcs.
3V