Built with
Ti400, Ti300 and Ti200
Advanced Performance
Infrared Cameras
This trio of new Fluke infrared cameras is equipped
with LaserSharp® Auto Focus. Yes, there are other
auto focus systems on the market but Fluke took
it one step further so you get consistently in-focus
images, Every. Single. Time. Every infrared camera
user knows that focus is the single most impor-
tant aspect to ensure when conducting an infrared
inspection. Without an in-focus image temperature
measurements may not be accurate and it’s much
easier to miss a problem. LaserSharp® Auto Focus
tells you exactly where you are focusing. It uses a
laser to calculate the distance to your target before
it focuses. Place the red laser dot on the object you
are inspecting, then pull and release the trigger for
a perfect in-focus image.
Only Fluke Connect™ gives you instant access to
critical dataunlike any other camera on the market
to keep your facility up and running
- Send measurements directly from the inspection
site to your boss or client and get answers and
approvals instantly
Detect and communicate issues faster with patented
Fluke IR-Fusion® technology with AutoBlendTM mode
Faster communication with wireless image transfer
directly to your PC, Apple® iPhone® or iPad®
One-handed, easy-to-use user interface
Ruggedized high resolution 640x480 capacitive
touch screen for quick menu navigation
Capture additional digital images to show location
or additional site details with IR-PhotoNotesTM
Annotation System
Standard and radiometric video recording*
Streaming video (USB and HDMI)
Text* and voice recording and annotation gets
additional details saved with the image file
Optional interchangeable lenses for greater flexibility
in additional applications
High-temperature measurement (up to 1200 °C on
the Ti400)
Included SmartView® and SmartView Mobile App
Analysis and Reporting Software
* Firmware updates for these features are not available yet
in all countries. Users notified via SmartView software when
available.
Technical Data
Ti400 Ti300 Ti200
Now compatible with Fluke
Connect
Mobile App
Fluke Connect with ShareLive video call is the only wireless
measurement system that lets you stay in contact with your entire
team without leaving the field. The Fluke Connect mobile app is
available for Android™ and iOS and works with over 20 different
Fluke products—the largest suite of connected test tools in the world.
And more is on the way. Go to the Fluke website to find out more.
Make the best decisions faster than ever before by viewing all
temperature, mechanical, electrical and vibration measurements
for each equipment asset in one place. Get started saving time and
increasing your productivity.
Download the app at:
See it. Save it. Share it.
All the facts, right in the field.
Smart phone not included with purchase.
Detailed specifications
Ti400 Ti300 Ti200
Temperature
Temperature measurement range
(not calibrated below -10 °C)
-20 °C to +1200 °C
(-4 °F to +2192 °F)
-20 °C to +650 °C
(-4 °F to +1202 °F)
Temperature measurement
accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction Yes (by number and table)
On-screen reflected background
temperature compensation Yes
On-screen transmission correction Yes
Imaging performance
Image capture frequency 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation
Detector type Focal Plane Array, uncooled
microbolometer, 320 x 240 pixels
Focal Plane Array, uncooled
microbolometer, 240 X 180 pixels
Focal Plane Array, uncooled
microbolometer, 200 X 150 pixels
Thermal sensitivity (NETD) ≤ 0.05 °C at 30 °C target temp (50 mK) ≤ 0.075 °C at 30 °C target temp (75 mK)
Total pixels 76,800 43,200 30,000
Infrared spectral band 7.5 μm to 14 μm (long wave)
Visual (visible light) camera Industrial performance 5.0 megapixel
Standard infrared lens type
Field of view 24 ° x 17 °
Spatial resolution (IFOV) 1.31 mRad 1.75 mRad 2.09 mRad
Minimum focus distance 15 cm (approx. 6 in)
Optional telephoto infrared lens type, available soon
Field of view 12 ° x 9 °
Spatial resolution (IFOV) 0.65 mRad 0.87 mRad 1.05 mRad
Minimum focus distance 45 cm (approx. 18 in)
Optional wide-angle infrared lens type, available soon
Field of view 46 ° x 34 °
Spatial resolution (IFOV) 2.62 mRad 3.49 mRad 4.19 mRad
Minimum focus distance 15 cm (approx. 6 in)
Focus mechanism
LaserSharp® Auto Focus System Yes
Advanced Manual Focus Yes
Image presentation
Palettes
Standard Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast™ Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra,
Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
Level and span Smooth auto-scaling and manual scaling of level and span
Fast auto toggle between manual
and auto modes Yes
Fast auto-rescale in manual mode Yes
Minimum span (in manual mode) 2.0 °C (3.6 °F)
Minimum span (in auto mode) 3.0 °C (5.4 °F)
IR-Fusion® information
Picture-In-Picture (PIP) Yes
Full screen infrared Yes
AutoBlend™ mode Yes
Color alarms (temperature alarms) High-temperature , low-temperature, and isotherm (user-selectable)
Image capture and data storage
Image capture, review,
save mechanism One-handed image capture, review, and save capability
Storage medium Micro SD Memory Card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
File formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) Video*: non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3)
No analysis software required for non-radiometric (.bmp, .jpg and .avi*) files
Export file formats w/SmartView®
software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Memory review Thumbnail view navigation and review selection
Other time-saving and productivity features
Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager
IR-PhotoNotes Yes
Wi-Fi connectivity Yes, to PC, iPhone®, iPad® and WiFi to LAN*
Text annotation* Yes
Video recording* Standard and Radiometric
Streaming Video Via USB to PC and HDMI to HDMI compatible screen
CNX™ Wireless System* Yes*
Fluke Connect compatible Yes
Auto capture (temperature and interval)* Yes*
Remote control and operation (for
special and advanced applications)
Yes No No
* Firmware updates for these features are not available yet in all countries.. Users notified via SmartView software when available.
2 Fluke Corporation Ti400, Ti300, and Ti200 Industrial Thermal Imagers
Optimize: Adjust the image to present problems in the most effective way.
Analyze: Use markers and other tools to quantify the severity of problems.
Communicate: Share inspection results by emailing images or reports.
Fluke SmartView Mobile will increase the return on your infrared camera investment.
It’s not just about working faster—it’s about working smarter.
Get the SmartView® Mobile app
Bring your office to your inspection site with the SmartView Mobile
App. Create an inspection report on site and communicate directly
to your client or manager via your Apple® iPhone® or iPad®.
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity 10 % to 95 % non-condensing
Ruggedized Touchscreen
Display (Capacitive)
8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight
Controls and adjustments User selectable temperature scale (°C/°F)
Language selection
Time/Date set
Emissivity selection
Reflected background temperature compensation
Transmission correction
User selectable hot spot and cold spot, and center point on the image
Expandable-contractable Measurement Box with MIN-AVG-MAX temp
Color alarms
User selectable backlight setting
Graphical information display preference
Software SmartView® and SmartView Mobile App - full analysis and reporting software
Batteries Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level, all models
Battery life Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD and average usage)
Battery charge time 2.5 hours to full charge
AC battery charging Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional
12 V automotive charging adapter. All models
AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included.
Power saving User selectable sleep and power off modes
Safety standards UL 61010-1:2012 CAN/CSA-C22.2 No.61010-1-12 IEC 61010-1 3rd Edition (2010)
Electromagnetic compatibility EN 61326-1:2006 IEC 61326-1:2005
C Tick IEC/EN 61326-1
US FCC CFR 47, Part 15 Subpart B Class B
Vibration 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6
Shock 25 g, IEC 68-2-29
Drop Engineered to withstand 2 meter (6.5 feet) with standard lens
Size (H x W x L) 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in)
Weight (battery included) 1.04 Kg (2.3 lb)
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty Two-years (standard), extended warranties are available.
Recommended calibration cycle Two-years (assumes normal operation and normal aging)
Supported Languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chi-
nese, Spanish, Swedish, Traditional Chinese, and Turkish
General specifications
4 Fluke Corporation Ti400, Ti300, and Ti200 Industrial Thermal Imagers
FLK-Ti400 9 Hz Thermal Imager, 9 Hz
FLK-Ti400 60 Hz Thermal Imager, 60 Hz
FLK-Ti300 9 Hz Thermal Imager, 9 Hz
FLK-Ti300 60 Hz Thermal Imager, 60 Hz
FLK-Ti200 9 Hz Thermal Imager, 9 Hz
FLK-Ti200 60 Hz Thermal Imager, 60 Hz
Included
Thermal imager with standard infrared lens; ac power supply and battery pack charger
(including mains adapters); two, rugged lithium ion smart battery packs; USB cable; HDMI video
cable; SmartView® software available via free download; rugged, hard carrying case; soft transport
bag; adjustable hand strap; warranty registration card.
Optional accessories
FLK-LENS/TELE2 Telephoto infrared lens (2X magnification)
FLK-LENS/WIDE2 Wide-angle infrared lens
TI-CAR-CHARGER Thermal imager vehicle charger
FLK-TI-VISOR3 Thermal imager visor
BOOK-ITP Introduction to Thermography Principles book
TI-TRIPOD3 Tripod mounting base accessory
FLK-Ti-SBP3 Additional smart battery
FLK-TI-SBC3 Additional Smart Battery Charger
Kits
FLK-TI400 60HZ/FCA* Thermal Imager, 3000 FC DMM, a3001FC iFlex Module
FLK-TI300 60HZ/FCA* Thermal Imager, 3000 FC DMM, a3001FC iFlex Module
FLK-TI200 60HZ/FCA* Thermal Imager, 3000 FC DMM, a3001FC iFlex Module
FLK-TI400 60HZ/FCC* Thermal Imager, 3-a3001FC iFlex Modules, 805
Vibration Tester, WiFi SD Card
FLK-TI400 9HZ/FCA Thermal Imager, 3000 FC DMM, a3001FC iFlex Module
FLK-TI300 9HZ/FCA Thermal Imager, 3000 FC DMM, a3001FC iFlex Module
FLK-TI200 9HZ/FCA Thermal Imager, 3000 FC DMM, a3001FC iFlex Module
FLK-TI400 9HZ/FCC Thermal Imager, 3-a3001FC iFlex Modules, 805
Vibration Tester, WiFi SD Card
Visit the Fluke website to get complete details on these products or kits or ask your local
Fluke sales representative.
*Only available in certain countries.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2013-2014 Fluke Corporation. All trademarks are the
property of their respective owners.
Specifications subject to change without notice.
Printed in U.S.A. 2/2014 4347232F_EN
Modification of this document is not permitted
without written permission from Fluke Corporation.
Ordering information
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Fluke:
FLK-TI400 60HZ/FCA FLK-TI400 60HZ/FCC FLK-TI200 60HZ/FCA FLK-TI300 60HZ/FCA