ISO 9001 ISO 14001 AS 9100 CERTIFIED
Mini-Circuits
®
P.O. Box 350166, Brooklyn, New York 11235-0003 (718) 934-4500 Fax (718) 332-4661
The Design Engineers Search Engine Provides ACTUAL Data Instantly at
®
Notes: 1. Performance and quality attributes and conditions not expressly stated in this specification sheet are intended to be excluded and do not form a part of this specification sheet. 2. Electrical specifications
and performance data contained herein are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. 3. The parts covered by this specification sheet are subject to
Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard
Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp.
For detailed performance specs
& shopping online see web site
minicircuits.com
IF/RF MICROWAVE COMPONENTS
Outline Drawing
Maximum Ratings
Outline Dimensions ( )
inch
mm
Operating Temperature -55°C to 100°C
Storage Temperature -55°C to 100°C
RF Power Input 0.5W max.
Applications
• labuse
• transmitters/receivers
• radiocommunications
NHP-250+
REV. C
M113397
NHP-250+
090820
50Ω 225 to 3000 MHz
CASE STYLE: FF57
Connectors Model Price Qty.
N-Type NHP-250+ $36.95 ea. (1-9)
electrical schematic
typical frequency response
High Pass Filter Electrical Specifications
High Pass Filter
Coaxial
STOPBAND
(MHz)
fco (MHz)
Nom.
PASSBAND
(MHz)
VSWR
(:1)
(loss>40dB) (loss>20dB) (loss3dB) (loss<1dB)
Stopband
Typ.
Passband
Typ.
DC-100 100-150 205 225-3000 17 1.3
Features
• ruggedshieldedcase
• otherstandardandcustomNHPmodelsavailable
withwideselectionoffco
Frequency
(MHz)
Insertion Loss
(dB)
Return Loss
(dB)
Frequency
(MHz)
Group Delay
(nsec)
_
xσ
INSERTION LOSS
0
1
10
100
0 600 1200 1800 2400 3000
FREQUENCY (MHz)
INSERTION LOSS (dB)
at RF level of 0 dBm
RETURN LOSS
0
5
10
15
20
25
30
35
40
0 600 1200 1800 2400 3000
FREQUENCY (MHz)
RETURN LOSS (dB)
at RF level of 0 dBm
GROUP DELAY
0.0
2.0
4.0
6.0
8.0
10.0
12.0
0 600 1200 1800 2400 3000
FREQUENCY (MHz)
GROUP DELAY (nsec)
at RF level of 0 dBm
10.00 72.15 5.67 0.03 100.00 2.23
100.00 57.26 0.27 0.08 129.00 2.63
129.00 41.25 0.45 0.17 130.00 2.59
130.00 40.71 0.46 0.18 140.00 2.90
140.00 35.39 0.54 0.20 150.00 3.17
150.00 30.09 0.62 0.22 160.00 3.63
160.00 24.78 0.73 0.26 166.00 4.00
166.00 21.57 0.80 0.29 170.00 4.32
170.00 19.43 0.85 0.34 180.00 5.39
180.00 14.04 0.97 0.53 190.00 7.09
190.00 8.77 1.03 1.02 199.00 9.19
199.00 4.65 0.89 2.21 200.00 9.41
200.00 4.26 0.86 2.43 201.00 9.63
201.00 3.90 0.83 2.67 202.00 9.83
202.00 3.56 0.79 2.93 203.00 10.02
203.00 3.24 0.75 3.23 204.00 10.18
204.00 2.94 0.70 3.56 205.00 10.32
205.00 2.66 0.66 3.91 206.00 10.43
206.00 2.41 0.61 4.31 210.00 10.58
210.00 1.60 0.42 6.27 225.00 8.03
225.00 0.55 0.03 23.49 300.00 2.94
300.00 0.30 0.02 30.05 400.00 1.59
500.00 0.19 0.00 33.64 500.00 1.09
600.00 0.19 0.00 30.85 600.00 0.83
700.00 0.19 0.01 28.81 700.00 0.67
800.00 0.20 0.01 28.48 800.00 0.58
900.00 0.20 0.01 29.04 900.00 0.52
1000.00 0.20 0.00 29.79 1000.00 0.47
2000.00 0.29 0.00 27.11 2000.00 0.34
3000.00 0.51 0.02 16.22 3000.00 0.32
Typical Performance Data
+ RoHS compliant in accordance
with EU Directive (2002/95/EC)
The +Suffix has been added in order to identify RoHS
Compliance. See our web site for RoHS Compliance
methodologies and qualifications.
20
40
3
1
Attenuation, dB
F requency/fco
DC .5 .75 11.1