For more Information
please call
1-800-Belden1
General Description:
18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation,
Duobond® IV quad shield (60% and 40% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
118 Solid BCCS - Bare Copper Covered Steel 1.016
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Material Dia. (mm)
Gas-injected FPE - Foam Polyethylene 4.572
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1Bonded Duofoil® Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100
2Braid AL - Aluminum 60
3Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
4 Braid AL - Aluminum 40
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 7.468 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -40°C To +80°C
Bulk Cable Weight: 43.158 Kg/Km
Max. Recommended Pulling Tension: 720.608 N
Min. Bend Radius/Minor Axis: 76.200 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1189A Coax - Broadband CATV Coax Cable
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Series Type: Series 6
Flame Test
UL Flame Test: UL1685 UL Loading
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 1189AP
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
75
Nom. Inductance:
Inductance (µH/m)
0.318257
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
53.1522
Nominal Velocity of Propagation:
VP (%)
83
Nominal Delay:
Delay (ns/m)
3.9372
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
91.868
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
15.7488
Max. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
52.19827
55 5.2496
211 9.41647
270 10.6304
300 11.2538
350 12.2053
400 13.124
450 13.9771
550 15.4535
750 18.3408
870 19.686
1000 21.4577
Max. Operating Voltage - UL:
Voltage
300 V RMS
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1189A Coax - Broadband CATV Coax Cable
Minimum Structural Return Loss:
Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Min. SRL (dB)
51000 20
Sweep Test
Sweep Testing: 5 MHz - 1 GHz
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
1189A 009U1000 305 MT 15.422 KG WHITE #18 GIFHDLDPE DBL SH PVC
1189A 009U500 152 MT 8.165 KG WHITE #18 GIFHDLDPE DBL SH PVC
1189A 0091000 305 MT 15.422 KG WHITE C #18 GIFHDLDPE DBL SH PVC
1189A 010U1000 305 MT 15.422 KG BLACK #18 GIFHDLDPE DBL SH PVC .
1189A 010U500 152 MT 8.165 KG BLACK #18 GIFHDLDPE DBL SH PVC
1189A 0101000 305 MT 15.422 KG BLACK #18 GIFHDLDPE DBL SH PVC .
1189A 0105000 1,524 MT 83.915 KG BLACK #18 GIFHDLDPE DBL SH PVC
1189A 2901000 305 MT 15.422 KG BEIGE, LIGHT #18 GIFHDLDPE DBL SH PVC
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 4 Revision Date: 08-09-2012
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1189A Coax - Broadband CATV Coax Cable