DOC-DTS-005-02, VCCM600S Industrial datasheet
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 459 1161 | www.vox-power.com
ENVIRONMENTAL SPECIFICATIONS
Operational limits subject to appropriate de-ratings
EN 60068-2-27: Half sine, 3 axes, 3 positive & 3 negative.
810G: Method 516.6, Procedure IV, Transit drop
EN 60068-2-6: Sine,10 – 500 Hz, 3 axes, 1 oct/min., 10 cycles each axis
EN 60068-2-64: Random, 5 – 500 Hz, 3 axes, 30 min.
810G: Method 514.6, Procedure I (General Vibration)
Category 4 (Trucks & Trailers, Composite wheeled vehicle), Figure 514.6C-3.
Category 7 (Aircraft, Jet cargo), Figure 514.6C-5 General exposure
Category 24, (All, Minimum integrity) Figure 514.6E-1
MIL-STD-810G Method 503.5 Procedure I-C. Multi-cycle. 3 shocks.
Notes 1. Some specifications may not be met below -20°C.
ELECTROMAGNETIC COMPLIANCE – EMISSIONS
Radiated emissions, electric field
Radiated emissions, electric field, 30Hz-18GHz.
MIL-STD-461F: RE102 (Ground, Fixed)
Compliant (When mounted in enclosure)
EN55011/22, FCC part 15, CISPR 22/11
Conducted emissions, power leads, 10kHz-10Mhz.
Compliant (External filter may be required)
ELECTROMAGNETIC COMPLIANCE – IMMUNITY
Test level 4: 15kV air, 8kV contact
Test Level 3: (10V/m, 80MHz-2.7GHz) sine wave AM 80% 1kHz
Proximity fields from RF wireless communications
equipment
Test levels as per IEC60601-1-2:2014 Table 9
Radiated susceptibility, electric field, 2 MHz to 40 GHz.
Electrical Fast Transients/bursts
Test Level 3: (2kV Power, 1kV I/O) 5kHz(ed3) & 100kHz(ed4)
Conducted susceptibility, Bulk cable injection, impulse
excitation
Test Level 3: 1kV L-N, 2kV L-E
Conducted susceptibility, damped sinusoidal transients,
cables and power leads, 10kHz-100MHz
Shipboard Electric Power. Voltage Spike Test
MIL-STD-1399, SECTION 300A
Type 1, 115V 60Hz single phase
Conducted disturbances induced by RF fields
Test Level 3: 10V, 0.15 to 80Mhz sine wave AM 80% 1kHz
Conducted susceptibility, power leads, 30Hz-150kHz
Conducted susceptibility, Bulk cable injection, 10kHz-
200Mhz
Power Frequency Magnetic Fields
Radiated susceptibility, Magnetic field, 30Hz-100kHz
0% 10ms, 0% 20ms (Criterion A)
70% 0.5s, 40% 200mS (Criterion A at 240V and Criterion B at 100V)
0% 20mS, 80% 1s,80% 10s,90% continuous (Criterion A)
70% 0.5s, 50% 200mS (Criterion A at 240V and Criterion B at 100V)
Criterion A is achieved for full power when Vin >=160V
Criterion A is achieved at all input voltages when Pout <= 350W
0% 250/300 cycle as per IEC60601-1-2:2014 (Criterion B)
Aircraft Electric Power Characteristic
SAC102,104,105,109,110 (MIL-HDBK-704-2) &
SXF102,104,105,109,110 (MIL-HDBK-704-6)
Notes:
1. Criterion A = No degradation of performance or loss of function.
Criterion B = Temporary degradation of performance or loss of function is allowed, provided the function is self-recoverable.
Criterion C = Temporary loss of function is allowed but requires operator intervention to recover.
2. Tested at nominal range (100V to 240V). Line deratings applied where appropriate.
IEC 60950-1:2005+AMD1:2009+AMD2:2013
CAN/CSA - C22.2 No. 60950-1-07
(R2012):2007+AMD1:2011+AMD2:2014
Information Technology Equipment - Safety - Part 1: General Requirements
LVD 2014/35/EU, EMC 2014/30/EU
CB certificate and report available on request