Product Folder Sample & Buy Support & Community Tools & Software Technical Documents LM73 SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 LM73 2.7-V, SOT-23, 11- to 14-Bit Digital Temperature Sensor With 2-Wire Interface 1 Features 3 Description * The LM73 is an integrated, digital-output temperature sensor featuring an incremental Delta-Sigma ADC with a two-wire interface that is compatible with the SMBus and I2C interfaces. The host can query the LM73 at any time to read temperature. 1 * * * * * * * * * Single Address Pin Offers Choice of Three Selectable Addresses Per Version for a Total of Six Possible Addresses. SMBus and I2C-compatible Two-Wire Interface Supports 400-Khz Operation Shutdown Mode With One-shot Feature Available for Very Low Average Power Consumption Programmable Digital Temperature Resolution From 11 Bits to 14 Bits Fast Conversion Rate Ideal for Quick Power Up and Measuring Rapidly Changing Temperature Open-Drain ALERT Output Pin Goes Active When Temperature is Above a Programmed Temperature Limit Very Stable, Low-noise Digital Output UL Recognized Component Key Specifications - Supply Current - Operating - 320 A (Typical) - 495 A (Maximum) - Shutdown - 8 A (Maximum) - 1.9 A (Typical) - Temperature Accuracy - -10C to 80C: 1.0C (Maximum) - -25C to 115C: 1.5C (Maximum) - -40C to 150C: 2C (Maximum) - Resolution - 0.25C to 0.03125C - Conversion Time - 11-Bit (0.25C): 14 ms (Maximum) - 14-Bit (0.03125C): 112 ms (Maximum) Available in a 6-pin SOT package, the LM73 occupies very little board area while operating over a wide temperature range (-40C to 150C) and providing 1C accuracy from -10C to 80C. The user can optimize between the conversion time and the sensitivity of the LM73 by programming it to report temperature in any of four different resolutions. Defaulting to 11-bit mode (0.25C/LSB), the LM73 measures temperature in a maximum time of 14 ms, making it ideal for applications that require temperature data very soon after power-up. In its maximum resolution, 14-bit mode (0.03125C/LSB), the LM73 is optimized to sense very small changes in temperature. A single multi-level address line selects one of three unique device addresses. An open-drain ALERT output goes active when the temperature exceeds a programmable limit. Both the data and clock lines are filtered for excellent noise tolerance and reliable communication. Additionally, a time-out feature on the clock and data lines causes the LM73 to automatically reset these lines if either is held low for an extended time, thus exiting any bus lock-up condition without processor intervention. Device Information(1) PART NUMBER LM73 PACKAGE BODY SIZE (NOM) SOT (6) 2.90 mm x 1.60 mm (1) For all available packages, see the orderable addendum at the end of the datasheet. Typical Application VDD = 2.7V to 5.5V Typical bypass 0.1 PF 3 2 Applications * * * * * Portable Electronics Notebook Computers Automotive System Thermal Management Office Electronics Address (set as desired for one of three addresses) To / from processor 2-wire interface ADDR SMBDAT SMBCLK 1 6 LM73 5 ALERT To hardware shutdown 4 2 1 An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA. LM73 SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 www.ti.com Table of Contents 1 2 3 4 5 6 Features .................................................................. Applications ........................................................... Description ............................................................. Revision History..................................................... Pin Configuration and Functions ......................... Specifications......................................................... 1 1 1 2 3 4 6.1 6.2 6.3 6.4 6.5 6.6 4 4 4 4 5 Absolute Maximum Ratings ...................................... ESD Ratings ............................................................ Recommended Operating Conditions....................... Thermal Information .................................................. Temperature-to-Digital Converter Characteristics..... Logic Electrical Characteristics- Digital DC Characteristics ........................................................... 6.7 Logic Electrical Characteristics- SMBus Digital Switching Characteristics........................................... 6.8 Typical Characteristics .............................................. 7 7.2 7.3 7.4 7.5 8 Functional Block Diagram ......................................... 9 Feature Description................................................... 9 Device Functional Modes........................................ 15 Register Map........................................................... 16 Application and Implementation ........................ 20 8.1 Application Information............................................ 20 8.2 Typical Application ................................................. 20 9 Power Supply Recommendations...................... 22 10 Layout................................................................... 22 10.1 Layout Guidelines ................................................. 22 10.2 Layout Example .................................................... 22 11 Device and Documentation Support ................. 23 6 7 8 Detailed Description .............................................. 9 7.1 Overview ................................................................... 9 11.1 11.2 11.3 11.4 Community Resources.......................................... Trademarks ........................................................... Electrostatic Discharge Caution ............................ Glossary ................................................................ 23 23 23 23 12 Mechanical, Packaging, and Orderable Information ........................................................... 23 4 Revision History Changes from Revision E (January 2015) to Revision F * Changed Temperature Accuracy spec typo on the front page............................................................................................... 1 Changes from Revision D (May 2009) to Revision E * 2 Page Page Added Pin Configuration and Functions section, ESD Ratings table, Feature Description section, Device Functional Modes, Application and Implementation section, Power Supply Recommendations section, Layout section, Device and Documentation Support section, and Mechanical, Packaging, and Orderable Information section .............................. 1 Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 LM73 www.ti.com SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 5 Pin Configuration and Functions SOT-23 6 PINS TOP VIEW ADDR 1 GND 2 VDD 3 LM73 6 SMBDAT 5 ALERT 4 SMBCLK Pin Functions PIN NO. 1 NAME ADDR TYPE CMOS Logic Input (three levels) EQUIVALENT CIRCUIT FUNCTION VDD PIN Snap Back D1 2.5k D2 Address Select Input: One of three device addresses is selected by connecting to ground, left floating, or connecting to VDD. D3 GND 2 GND Ground Ground 3 VDD Power Supply Voltage SMBCLK CMOS Logic Input PIN 4 Snap Back D1 Serial Clock: SMBus clock signal. Operates up to 400 kHz. Low-pass filtered. GND VDD 5 ALERT OpenDrain Output PIN Snap Back D1 125 D2 Digital output which goes active whenever the measured temperature exceeds a programmable temperature limit. D3 GND PIN 6 SMBDAT OpenDrain Input/Outp ut Snap Back D1 Serial Data: SMBus bi-directional data signal used to transfer serial data synchronous to the SMBCLK. Low-pass filtered. GND Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 3 LM73 SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 www.ti.com 6 Specifications 6.1 Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted) (1) (2) MIN NOM -0.3 Supply Voltage MAX UNIT V to 6 V 6 V -0.3 V to V Voltage at SMBCLK and SMBDAT pins -0.3 Voltage at All Other Pins (VDD + 0.5) 6 V 5 mA 150 C Input Current at Any Pin (3) -65 Storage Temperature, Tstg (1) (2) (3) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. Soldering process must comply with Texas Instruments' Reflow Temperature Profile specifications. Refer to www.ti.com/packaging.. Reflow temperature profiles are different for lead-free and non-lead-free packages. When the input voltage (VI) at any pin exceeds the power supplies (VI < GND or VI > VDD), the current at that pin should be limited to 5 mA. 6.2 ESD Ratings VALUE V(ESD) (1) Electrostatic discharge Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001 (1) 2000 Machine Model 200 UNIT V JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. 6.3 Recommended Operating Conditions over operating free-air temperature range (unless otherwise noted) MIN MAX UNIT LM73CIMK-0, LM73CIMK-1 -40 150 C Supply Voltage Range (VDD) 2.7 5.5 V 6.4 Thermal Information LM73 THERMAL METRIC (1) DDC (SOT) UNIT 6 PINS RJA Junction-to-ambient thermal resistance 224 RJC(top) Junction-to-case (top) thermal resistance 89 (1) 4 C/W For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953. Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 LM73 www.ti.com SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 6.5 Temperature-to-Digital Converter Characteristics Unless otherwise noted, these specifications apply for VDD = 2.7 V to 5.5 V. All limits TA = TJ = 25C, unless otherwise noted. TA is the ambient temperature. TJ is the junction temperature. PARAMETER TEST CONDITIONS VDD = 2.7V to VDD = 4.5V Accuracy (2) VDD > 4.5V to VDD = 5.5V MIN 1 C TA = -25C to 115C TA = TJ =TMIN to TMAX 1.5 C TA = -40C to 150C TA = TJ =TMIN to TMAX 2 C TA = -10C to 80C TA = TJ =TMIN to TMAX 1.5 C TA = -25C to 115C TA = TJ =TMIN to TMAX 2 C TA = -40C to 150C TA = TJ =TMIN to TMAX 2.5 12 RES1 Bit = 1, RES0 Bit = 1 Continuous Conversion Mode, SMBus inactive Shutdown, bus-idle timers on Shutdown, bus-idle timers off (1) (2) (3) Bits C/LSB 13 Bits 0.0625 C/LSB 14 Bits 0.03125 C/LSB 10.1 TA = TJ =TMIN to TMAX 14 20.2 TA = TJ =TMIN to TMAX 28 (3) RES1 Bit = 1, RES0 Bit = 0 C/LSB 0.125 RES1 Bit = 1, RES0 Bit = 1 RES1 Bit = 0, RES0 Bit = 1 Bits 0.25 RES1 Bit = 1, RES0 Bit = 0 RES1 Bit = 0, RES0 Bit = 0 C 11 Resolution Power-On Reset Threshold UNIT TA = TJ =TMIN to TMAX RES1 Bit = 0, RES0 Bit = 1 Quiescent Current MAX (1) TA = -10C to 80C RES1 Bit = 0, RES0 Bit = 0 Temperature Conversion Time TYP 40.4 TA = TJ =TMIN to TMAX 56 80.8 TA = TJ =TMIN to TMAX 112 320 TA = TJ =TMIN to TMAX 495 120 TA = TJ =TMIN to TMAX 175 1.9 TA = TJ =TMIN to TMAX Measured on VDD input, falling edge TA = TJ =TMIN to TMAX 8 0.9 ms ms ms ms A A A V Limits are specified to AOQL (Average Outgoing Quality Level). Local temperature accuracy does not include the effects of self-heating. The rise in temperature due to self-heating is the product of the internal power dissipation of the LM73 and the thermal resistance. This specification is provided only to indicate how often temperature data is updated. The LM73 can be read at any time without regard to conversion state (and will yield last conversion result). Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 5 LM73 SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 www.ti.com 6.6 Logic Electrical Characteristics- Digital DC Characteristics Unless otherwise noted, these specifications apply for VDD = 2.7 V to 5.5 V. All limits TA = TJ = 25C, unless otherwise noted. TA is the ambient temperature. TJ is the junction temperature. PARAMETER TEST CONDITIONS MIN TYP (1) MAX (2) UNIT SMBDAT, SMBCLK INPUTS VIH Logical 1 Input Voltage TA = TJ =TMIN to TMAX VIL Logical 0 Input Voltage TA = TJ =TMIN to TMAX 0.7 x VDD V 0.3 x VDD SMBDAT and VIN;HYST SMBCLK Digital Input Hysteresis 0.07 x VDD IIH Logical 1 Input Current VIN = VDD IIL Logical 0 Input Current VIN = 0 V CIN Input Capacitance V 0.01 TA = TJ =TMIN to TMAX 2 -0.01 TA = TJ =TMIN to TMAX V -2 5 A A pF SMBDAT, ALERT OUTPUTS IOH High Level Output VOH = VDD Current VOL SMBus Low Level IOL = 3 mA Output Voltage 0.01 TA = TJ =TMIN to TMAX 2 TA = TJ =TMIN to TMAX 0.4 A V ADDRESS INPUT VIH;ADD Address Pin High Input Voltage TA = TJ =TMIN to TMAX VIL;ADDR Address Pin Low Input Voltage ESS TA = TJ =TMIN to TMAX RESS IIH; ADDRESS IIL;ADDR ESS (1) (2) 6 Address Pin High Input Current VIN = VDD Address Pin Low Input Current VIN = 0 V VDD - 0.100 V 0.100 0.01 TA = TJ =TMIN to TMAX 2 -0.01 TA = TJ =TMIN to TMAX -2 V A A Typicals are at TA = 25C and represent most likely parametric norm. Limits are specified to AOQL (Average Outgoing Quality Level). Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 LM73 www.ti.com SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 6.7 Logic Electrical Characteristics- SMBus Digital Switching Characteristics Unless otherwise noted, these specifications apply for VDD = 2.7 V to 5.5 V, CL (load capacitance) on output lines = 400 pF. All limits TA = TJ = 25C, unless otherwise noted. See Figure 1. PARAMETER TEST CONDITIONS MIN TYP (1) MAX (2) UNIT fSMB SMBus Clock Frequency No minimum clock frequency if TimeOut feature is disabled. tLOW SMBus Clock Low Time TA = TJ =TMIN to TMAX 300 ns tHIGH SMBus Clock High Time TA = TJ =TMIN to TMAX 300 ns tF;SMB Output Fall Time CL = 400 pF IPULL-UP 3 mA (3) O TA = TJ =TMIN to TMAX 400 TA = TJ =TMIN to TMAX kHz 250 ns 45 ms SMBDAT and SMBCLK Time Low for Reset of Serial Interface TA = TJ =TMIN to TMAX 15 Data In Setup Time to SMBCLK High TA = TJ =TMIN to TMAX 100 ns tHD;DA Data Hold Time: Data In Stable after SMBCLK Low TI TA = TJ =TMIN to TMAX 0 ns tHD;DA Data Hold Time: Data Out Stable after SMBCLK Low TO TA = TJ =TMIN to TMAX 30 ns tTIMEO UT tSU;DAT (4) tHD;STA Start Condition SMBDAT Low to SMBCLK Low (Start condition hold before the first clock falling edge) TA = TJ =TMIN to TMAX 60 ns tSU;ST Stop Condition SMBCLK High to SMBDAT Low (Stop Condition Setup) TA = TJ =TMIN to TMAX 50 ns SMBus Repeated Start-Condition tSU;STA Setup Time, SMBCLK High to SMBDAT Low TA = TJ =TMIN to TMAX 50 ns SMBus Free Time Between Stop and Start Conditions TA = TJ =TMIN to TMAX 1.2 s O tBUF tPOR (1) (2) (3) (4) (5) Power-On Reset Time (5) TA = TJ =TMIN to TMAX 1 ms Typicals are at TA = 25C and represent most likely parametric norm. Limits are specified to AOQL (Average Outgoing Quality Level). The output fall time is measured from (VIH;MIN + 0.15V) to (VIL;MAX - 0.15V). Holding the SMBDAT and/or SMBCLK lines Low for a time interval greater than tTIMEOUT will reset the LM73's SMBus state machine, setting SMBDAT and SMBCLK pins to a high impedance state. Represents the time from VDD reaching the power-on-reset level to the LM73 communications being functional. After an additional time equal to one temperature conversion time, valid temperature is available in the Temperature Data Register . tLOW tR tF VIH SMBCLK VIL tHD;STA tHD;DAT tBUF SMBDAT VIH VI tHIGH tSU;STA tSU;DAT tSU;STO P L S S P Figure 1. SMBus Communication Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 7 LM73 SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 www.ti.com 6.8 Typical Characteristics 8 Figure 2. Accuracy vs. Temperature Figure 3. Operating Current vs. Temperature Figure 4. Shutdown Current vs.Temperature Figure 5. Typical Output Noise Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 LM73 www.ti.com SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 7 Detailed Description 7.1 Overview The LM73 is a digital temperature sensor that senses the temperature of its die using a sigma-delta analog-todigital converter and stores the temperature in the Temperature Register. The LM73's 2-wire serial interface is compatible with SMBus 2.0 and I2C. Please see the SMBus 2.0 specification for a detailed description of the differences between the I2C bus and SMBus. The temperature resolution is programmable, allowing the host system to select the optimal configuration between sensitivity and conversion time. The LM73 can be placed in shutdown to minimize power consumption when temperature data is not required. While in shutdown, a 1-shot conversion mode allows system control of the conversion rate for ultimate flexibility. 7.2 Functional Block Diagram 2.7V to 5.5V VDD Temperature Sensor Circuitry 11-Bit to 14-Bit Delta-Sigma A/D Converter LM73 Manufacturer's ID Register Control/Status Register Configuration Register Pointer Register and Decode Logic Temperature Register THIGH Register Set-Point Comparator ALERT TLOW Register ADDR Two-Wire Serial Interface SMBDAT SMBCLK GND 7.3 Feature Description The LM73 features the following registers. See LM73 Registers for a complete list of the pointer address, content, and reset state of each register. * Pointer Register Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 9 LM73 SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 www.ti.com Feature Description (continued) * * * * * * Temperature Register Configuration Register THIGH Register TLOW Register Control/Status Register Identification Register 7.3.1 Power-On Reset The power-on reset (POR) state is the point at which the supply voltage rises above the power-on reset threshold (specified in the Electrical Characteristics), generating an internal reset. Each of the registers contains a defined value upon POR and this data remains there until any of the following occurs: * The first temperature conversion is completed, causing the Temperature Register and various status bits to be updated internally, depending on the value of the measured temperature. * The master writes different data to any Read/Write (R/W) bits, or * The LM73 is powered down. 7.3.2 One-Shot Conversion The LM73 features a one-shot conversion bit, which is used to initiate a single conversion and comparison cycle when the LM73 is in shutdown mode. While the LM73 is in shutdown mode, writing a 1 to the One-Shot bit in the Configuration Register will cause the LM73 to perform a single temperature conversion and update the Temperature Register and the affected status bits. Operating the LM73 in this one-shot mode allows for extremely low average-power consumption, making it ideal for low-power applications. When the One-Shot bit is set, the LM73 initiates a temperature conversion. After this initiation, but before the completion of the conversion and resultant register updates, the LM73 is in a "one-shot" state. During this state, the Data Available (DAV) flag in the Control/Status register is 0 and the Temperature Register contains the value 8000h (-256C). All other registers contain the data that was present before initiating the one-shot conversion. After the temperature measurement is complete, the DAV flag will be set to 1 and the temperature register will contain the resultant measured temperature. 7.3.3 Temperature Data Format The resolution of the temperature data and the size of the data word are user-selectable through bits RES1 and RES0 in the Control/Status Register. By default, the LM73 temperature stores the measured temperature in an 11-bit (10 bits plus sign) word with one least significant bit (LSB) equal to 0.25C. The maximum word size is 14 bits (13-bits plus sign) with a resolution of 0.03125 C/LSB. CONTROL BIT DATA FORMAT RES1 RES0 WORD SIZE 0 0 11 bits RESOLUTION 0.25 C/LSB 0 1 12 bits 0.125 C/LSB 1 0 13 bits 0.0625 C/LSB 1 1 14 bits 0.03125 C/LSB The temperature data is reported in 2's complement format. The word is stored in the 16-bit Temperature Register and is left justified in this register. Unused temperature-data bits are always reported as 0. Table 1. 11-Bit (10-Bit Plus Sign) TEMPERATURE 10 DIGITAL OUTPUT BINARY HEX 150C 0100 1011 0000 0000 4B00h 25C 0000 1100 1000 0000 0C80h 1C 0000 0000 1000 0000 0080h 0.25C 0000 0000 0010 0000 0020h Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 LM73 www.ti.com SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 Table 1. 11-Bit (10-Bit Plus Sign) (continued) TEMPERATURE DIGITAL OUTPUT BINARY HEX 0C 0000 0000 0000 0000 0000h -0.25C 1111 1111 1110 0000 FFE0h -1C 1111 1111 1000 0000 FF80h -25C 1111 0011 1000 0000 F380h -40C 1110 1100 0000 0000 EC00h Table 2. 12-Bit (11-Bit Plus Sign) TEMPERATURE DIGITAL OUTPUT BINARY HEX 150C 0100 1011 0000 0000 4B00h 25C 0000 1100 1000 0000 0C80h 1C 0000 0000 1000 0000 0080h 0.125C 0000 0000 0001 0000 0010h 0C 0000 0000 0000 0000 0000h -0.125C 1111 1111 1111 0000 FFF0h FF80h -1C 1111 1111 1000 0000 -25C 1111 0011 1000 0000 F380h -40C 1110 1100 0000 0000 EC00h Table 3. 13-Bit (12-Bit Plus Sign) TEMPERATURE DIGITAL OUTPUT BINARY HEX 150C 0100 1011 0000 0000 4B00h 25C 0000 1100 1000 0000 0C80h 1C 0000 0000 1000 0000 0080h 0.0625C 0000 0000 0000 1000 0008h 0C 0000 0000 0000 0000 0000h -0.0625C 1111 1111 1111 1000 FFF8h -1C 1111 1111 1000 0000 FF80h -25C 1111 0011 1000 0000 F380h -40C 1110 1100 0000 0000 EC00h Table 4. 14-Bit (13-Bit Plus Sign) TEMPERATURE DIGITAL OUTPUT BINARY HEX 150C 0100 1011 0000 0000 4B00h 25C 0000 1100 1000 0000 0C80h 1C 0000 0000 1000 0000 0080h 0.03125C 0000 0000 0000 0100 0004h 0C 0000 0000 0000 0000 0000h -0.03125C 1111 1111 1111 1100 FFFCh -1C 1111 1111 1000 0000 FF80h -25C 1111 0011 1000 0000 F380h -40C 1110 1100 0000 0000 EC00h Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 11 LM73 SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 www.ti.com 7.3.4 SMBus Interface The LM73 operates as a slave on the SMBus. The SMBDAT line is bidirectional. The SMBCLK line is an input only. The LM73 never drives the SMBCLK line and it does not support clock stretching. The LM73 uses a 7-bit slave address. It is available in two versions. Each version can be configured for one of three unique slave addresses, for a total of six unique address. PART NUMBER ADDRESS PIN DEVICE ADDRESS LM73-0 Float Ground VDD 1001 000 1001 001 1001 010 LM73-1 Float Ground VDD 1001 100 1001 101 1001 110 The SMBDAT output is an open-drain output and does not have internal pull-ups. A "high" level will not be observed on this pin until pull-up current is provided by some external source, typically a pull-up resistor. Choice of resistor value depends on many system factors but, in general, the pull-up resistor should be as large as possible without effecting the SMBus desired data rate. This will minimize any internal temperature reading errors due to internal heating of the LM73. The LM73 features an integrated low-pass filter on both the SMBCLK and the SMBDAT line. These filters increase communications reliability in noisy environments. If either the SMBCLK or SMBDAT line is held low for a time greater than tTIMEOUT (see Logic Electrical Characteristics for the value of tTIMEOUT), the LM73 state machine will reset to the SMBus idle state, releasing the data line. Once the SMBDAT is released high, the master may initiate an SMBus start. 7.3.5 ALERT Function The ALERT output is an over-temperature indicator. At the end of every temperature conversion, the measured temperature is compared to the value in the THIGH Register. If the measured temperature exceeds the value stored in THIGH, the ALERT output goes active (see Figure 6). This over-temperature condition will also cause the ALRT_STAT bit in the Control/Status Register to change value (this bit mirrors the logic level of the ALERT pin). The ALERT pin and the ALRT_STAT bit are cleared when any of the following occur: * The measured temperature falls below the value stored in the TLOW Register * A 1 is written to the ALERT Reset bit in the Configuration Register * The master resets it through an SMBus Alert Response Address (ARA) procedure If ALERT has been cleared by the master writing a 1 to the ALERT Reset bit, while the measured temperature still exceeds the THIGH setpoint, ALERT will go active again after the completion of the next temperature conversion. Each temperature reading is associated with a Temperature High (THI) and a Temperature Low (TLOW) flag in the Control/Status Register. A digital comparison determines whether that reading is above the THIGH setpoint or below the TLOW setpoint. If so, the corresponding flag is set. All digital comparisons to the THIGH, and TLOW values are based on an 11-bit temperature comparison. Regardless of the resolution setting of the LM73, the lower three temperature LSBs will not affect the state of the ALERT output, THI flag, and TLOW flag. 12 Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 LM73 www.ti.com SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 Measured Temperature TEMPERATURE THIGH Limit TLOW Limit ALERT pin TIME Figure 6. ALERT Temperature Response Cleared When Temperature Crosses TLOW ALERT 5HVHW %LW VHW WR 1 Measured Temperature TEMPERATURE THIGH Limit TLOW Limit ALERT (Active Low) One Conversion Time TIME Figure 7. ALERT Temperature Response Cleared by Writing a 1 to the ALERT Reset Bit. 7.3.6 Communicating With the LM73 The data registers in the LM73 are selected by the Pointer Register. At power-up the Pointer Register is set to 00h, the location for the Temperature Register. The Pointer Register latches the last location it was set to. Note that all Pointer Register bits are decoded; any incorrect pointer values will not be acknowledged and will not be stored in the Pointer Register. NOTE A write to an invalid pointer address is not allowed. If the master writes an invalid address to the Pointer Register, the LM73 will not acknowledge the address and the Pointer Register will continue to contain the last value stored in it. A Write to the LM73 will always include the address byte and the pointer byte. A Read from the LM73 can occur in either of the following ways: * If the location latched in the Pointer Register is correct (that is, the Pointer Register is pre-set prior to the read), then the read can simply consist of an address byte, followed by retrieving the data byte. Most of the time it is expected that the Pointer Register will point to Temperature Registers because that will be the data most frequently read from the LM73. * If the Pointer Register needs to be set, then an address byte, pointer byte, repeat start, and another address byte will accomplish a read. The data byte is read out of the LM73 by the most significant bit first. At the end of a read, the LM73 can accept either an Acknowledge or No Acknowledge bit from the Master. No Acknowledge is typically used as a signal to the slave that the Master has read its last byte. Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 13 LM73 SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 www.ti.com 7.3.6.1 Reading from the LM73 1 9 1 9 1 9 SMBCLK SMBDAT 1 0 0 1 A2 A1 A0 D15 D14 D13 D12 D11 D10 R/W D9 D8 Ack by LM73 Start by Master D7 D6 D5 D4 D3 D2 D1 D0 Ack by Master Frame 1 Serial Bus Address Byte NoAck Stop by by Master Master Frame 2 Data Byte from LM73 Frame 3 Data Byte from LM73 Figure 8. Typical Read from a 2-Byte Register with Preset Pointer 1 9 1 9 SMBCLK SMBDAT 1 0 0 1 A2 A1 A0 0 R/W 0 0 0 SMBDAT (continued) P2 P1 P0 Ack by LM73 Frame 1 Serial Bus Address Byte Frame 2 Pointer Byte 1 SMBCLK (continued) 0 Ack by LM73 Start by Master 1 9 0 0 1 A2 A1 A0 9 D15 D14 D13 D12 D11 D10 R/W Repeat Start by Master 1 D9 1 D8 Ack by LM73 D7 9 D6 D5 D4 D3 D2 D1 Ack by Master Frame 3 Serial Bus Address Byte D0 NoAck Stop by by Master Master Frame 4 Data Byte from LM73 Frame 5 Data Byte from LM73 Figure 9. Typical Pointer Set Followed by Immediate Read of a 2-Byte Register 1 9 1 9 SMBCLK SMBDAT 1 0 0 1 A2 A1 A0 R/W Start by Master Frame 1 Serial Bus Address Byte D7 D6 Ack by LM73 D5 D4 D3 D2 D1 Frame 2 Data Byte from LM73 D0 NoAck Stop by by Master Master Figure 10. Typical Read from a 1-Byte Register with Preset Pointer 14 Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 LM73 www.ti.com SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 1 9 1 9 SMBCLK SMBDAT 1 0 0 1 A2 A1 A0 0 R/W 0 0 0 0 P2 P1 P0 Ack by LM73 Start by Master Ack by LM73 Frame 1 Serial Bus Address Byte Frame 2 Pointer Byte 1 9 1 9 SMBCLK (continued) SMBDAT (continued) 1 0 0 1 A2 A1 A0 D7 R/W D6 D5 D4 D3 D2 D1 D0 NoAck Stop by by Master Master Ack by LM73 Repeat Start by Master Frame 3 Serial Bus Address Byte Frame 4 Data Byte from LM73 Figure 11. Typical Pointer Set Followed by Immediate Read of a 1-Byte Register 7.3.6.2 Writing to the LM73 1 9 1 1 9 9 SMBCLK SMBDAT 1 0 0 1 A2 A1 A0 0 R/W Start by Master 0 0 0 0 P2 P1 D7 P0 Ack by LM73 D6 D5 D4 D3 D2 Ack by LM73 Frame 1 Serial Bus Address Byte D1 D0 Ack Stop by by LM73 Master Frame 2 Pointer Byte Frame 3 Data Byte to LM73 Figure 12. Typical 1-Byte Write 1 9 1 9 SMBCLK SMBDAT 1 0 0 1 A2 A1 A0 0 R/W 0 0 0 0 P2 P1 P0 Ack by LM73 Start by Master Ack by LM73 Frame 1 Serial Bus Address Byte Frame 2 Pointer Byte 1 9 1 9 SMBCLK (continued) SMBDAT (continued) D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 Ack by LM73 Frame 3 Data Byte to LM73 D1 D0 Ack Stop by by LM73 Master Frame 4 Data Byte to LM73 Figure 13. Typical 2-Byte Write 7.4 Device Functional Modes 7.4.1 Shutdown Mode Shutdown Mode is enabled by writing a "1" to the Full Power Down Bit, Bit 7 of the Configuration Register, and holding it high for at least the specified maximum conversion time at the existing temperature resolution setting. (see Temperature Conversion Time specifications under the Temperature-to-Digital Converter Characteristics). For example, if the LM73 is set for 12-bit resolution before shutdown, then Bit 7 of the Configuration register must go high and stay high for the specified maximum conversion time for 12-bits resolution. Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 15 LM73 SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 www.ti.com Device Functional Modes (continued) The LM73 will always finish a temperature conversion and update the temperature registers before shutting down. Writing a "0" to the Full Power Down Bit restores the LM73 to normal mode. The user should wait at least the specified maximum conversion time, at the existing resolution setting, before accurate data appears in the temperature register. 7.5 Register Map 7.5.1 LM73 Registers The LM73's internal registers are selected by the Pointer register. The Pointer register latches the last location that it was set to. The pointer register and all internal registers are described below. All registers reset at device power up. 7.5.1.1 Pointer Register The diagram below shows the Pointer Register, the six internal registers to which it points, and their associated pointer addresses. SMBDAT Interface SMBCLK Address Data Pointer Register (selects register for communication) Temperature (Read-Only) Pointer = 00000000 Configuration (Read-Write) Pointer = 00000001 THIGH (Read-Write) Pointer = 00000010 TLOW (Read-Write) Pointer = 00000011 Control/Status (Read-Write) Pointer = 00000100 Identification (Read-Only) Pointer = 00000111 16 P7 P6 P5 P4 P3 0 0 0 0 0 P2 Submit Documentation Feedback P1 P0 Register Select Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 LM73 www.ti.com SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 Bits Name Description 7:3 Not Used Must write zeros only. 2:0 Register Select Pointer address. Points to desired register. See table below. (1) P2 P1 P0 REGISTER (1) 0 0 0 Temperature 0 0 1 Configuration 0 1 0 THIGH 0 1 1 TLOW 1 0 0 Control / Status 1 1 1 Identification A write to an invalid pointer address is not allowed. If the master writes an invalid address to the Pointer Register, (a) the LM73 will not acknowledge the address and (b) the Pointer Register will continue to contain the last value stored in it. 7.5.1.2 Temperature Data Register Pointer Address 00h (Read Only) Reset State: 7FFCh (+255.96875C) One-Shot State: 8000h (-256C) D15 D14 D13 D12 D11 D10 D9 D8 SIGN 128C 64C 32C 16C 8C 4C 2C D7 D6 D5 D4 D3 D2 D1 D0 1C 0.5C 0.25C 0.125C 0.0625C 0.03125C reserved reserved Bits Name Description 15:2 Temperature Data Represents the temperature that was measured by the most recent temperature conversion. On Power-up, this data is invalid until the Data Available (DAV) bit in the Control/Status register is high (after the completion of the first temperature conversion). The resolution is user-programable from 11bit resolution (0.25C/LSB) through 14-bit resolution (0.03125C/LSB). The desired resolution is programmed with bits 5 and 6 of the Control/Status register. 1:0 Not Used Return zeros upon read. Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 17 LM73 SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 www.ti.com 7.5.1.3 Configuration Register Pointer Address 01h (R/W) Reset State: 40h D7 D6 D5 D4 D3 D2 PD reserved ALRT EN ALRT POL ALRT RST ONE SHOT D1 D0 reserved Bits Name Description 7 Full Power Down Writing a 1 to this bit and holding it high for at least the specified maximum conversion time, at the existing temperature resolution setting, puts the LM73 in shutdown mode for power conservation. Writing a 0 to this bit restores the LM73 to normal mode. Waiting one specified maximum conversion time for the existing resolution setting assures accurate data in the temperature register. 6 reserved User must write only a 1 to this bit 5 ALERT Enable A 0 in this location enables the ALERT output. A 1 disables it. This bit also controls the ALERT Status bit (the Control/Status Register, Bit 3) since that bit reflects the state of the Alert pin. 4 ALERT Polarity When set to 1, the ALERT pin and ALERT Status bit are active-high. When 0, it is active-low. 3 ALERT Reset Writing a 1 to this bit resets the ALERT pin and the ALERT Status bit. It will always be 0 when read. 2 One Shot When in shutdown mode (Bit 7 is 1), initiates a single temperature conversion and update of the temperature register with new temperature data. Has no effect when in continuous conversion mode (i.e., when Bit 7 is 0). Always returns a 0 when read. 1:0 Reserved User must write only a 0 to these bits. 7.5.1.4 THIGH Upper-Limit Register Pointer Address 02h (R/W) Reset State: 7FE0h (+255.75C) D15 D14 D13 D12 D11 D10 D9 D8 SIGN 128C 64C 32C 16C 8C 4C 2C D4 D3 D2 D1 D0 D7 D6 D5 1C 0.5C 0.25C reserved Bits Name Description 15:5 Upper-Limit Temperature If the measured temperature that is stored in this register exceeds this user-programmable upper temperature limit, the ALERT pin will go active and the THIGH flag in the Control/Status register will be set to 1. Two's complement format. 4:0 Reserved Returns zeros upon read. Recommend writing zeros only in these bits. 7.5.1.5 TLOW Lower-Limit Register Pointer Address 03h (R/W) Reset State: 8000h (-256C) D15 D14 D13 D12 D11 D10 D9 D8 SIGN 128C 64C 32C 16C 8C 4C 2C D7 D6 D5 D4 D3 D2 D1 D0 1C 0.5C 0.25C reserved Bits Name Description 15:5 Lower-Limit Temperature If the measured temperature that is stored in the temperature register falls below this userprogrammable lower temperature limit, the ALERT pin will be deactivated and the TLOW flag in the Control/Status register will be set to 1. Two's complement format. 4:0 Reserved Returns zeros upon read. Recommend writing zeros only in these bits. 18 Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 LM73 www.ti.com SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 7.5.1.6 Control/Status Register Pointer Address 04h (R/W) Reset State: 08h D7 D6 D5 D4 D3 D2 D1 D0 TO_DIS RES1 RES0 reserved ALRT_STAT THI TLOW DAV BITS NAME DESCRIPTION 7 Time-Out Disable Disable the time-out feature on the SMBDAT and SMBCLK lines if set to 1. Setting this bit turns off the bus-idle timers, enabling the LM73 to operate at lowest shutdown current. 6:5 Temperature Resolution Selects one of four user-programmable temperature data resolutions 00: 0.25C/LSB, 11-bit word (10 bits plus Sign) 01: 0.125C/LSB, 12-bit word (11 bits plus Sign) 10: 0.0625C/LSB, 13-bit word (12 bits plus Sign) 11: 0.03125C/LSB, 14-bit word (13 bits plus Sign) 4 reserved Always returns zero when read. Recommend customer write zero only. 3 ALERT Pin Status Value is 0 when ALERT output pin is low. Value is 1 when ALERT output pin is high. The ALERT output pin is reset under any of the following conditions: (1) Cleared by writing a 1 to the ALERT Reset bit in the configuration register, (2) Measured temperature falls below the TLOW limit, or (3) cleared via the ARA sequence. Recommend customer write zero only. 2 Temperature High Flag Bit is set to 1 when the measured temperature exceeds the THIGH limit stored in the programmable THIGH register. Flag is reset to 0 when both of the following conditions are met: (1) measured temperature no longer exceeds the programmed THIGH limit and (2) upon reading the Control/Status register. If the temperature is not longer above the THIGH limit, this status bit remains set until it is read by the master so that the system can check the history of what caused the ALERT output to go active. This bit is not cleared after every read if the measured temperature is still above the THIGH limit. 1 Temperature Low Flag Bit is set to 1 when the measured temperature falls below the TLOW limit stored in the programmable TLOW register. Flag is reset to 0 when both of the following conditions are met: (1) measured temperature is no longer below the programmed TLOW limit and (2) upon reading the Control/Status register. If the temperature is no longer below the TLOW limit, the status bit remains set until it is read by the master so that the system can check the history of what cause the ALERT output to go active. This bit is not cleared after every read if temperature is still below TLOW limit. 0 Data Available Flag This bit is 0 when the LM73 is in the process of converting a new temperature. It is 1 when the conversion is done. After initiating a temperature conversion while operating in the one-shot mode, this status bit can be monitored to indicate when the conversion is done. After triggering the one-shot conversion, the data in the temperature register is invalid until this bit is high (that is, after completion of the conversion). On power-up, the LM73 is in continuous conversion mode; while in continuous conversion mode (the default mode after power-on reset) this bit will always be high. Recommend customer write zero only. 7.5.1.7 Identification Register Pointer Address 07h (Read Only) Reset State: 0190h D15 D14 D13 D12 D11 D10 D9 D8 0 0 0 0 0 0 0 1 D7 D6 D5 D4 D3 D2 D1 D0 1 0 0 1 0 0 0 0 BITS NAME DESCRIPTION 15:8 Manufacturer Identification Byte Always returns 01h to uniquely identify the manufacturer as Texas Instruments. 7:4 Product Identification Nibble Always returns 9h to uniquely identify this part as the LM73 Temperature Sensor. 3:0 Die Revision Step Nibble Always returns 0h to uniquely identify the revision as level zero. Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 19 LM73 SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 www.ti.com 8 Application and Implementation NOTE Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI's customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design implementation to confirm system functionality. 8.1 Application Information 8.1.1 Thermal Path Considerations To get the expected results when measuring temperature with an integrated circuit temperature sensor like the LM73, it is important to understand that the sensor measures its own die temperature. For the LM73, the best thermal path between the die and the outside world is through the LM73's pins. In the SOT23 package, all the pins on the LM73 will have an equal effect on the die temperature. Because the pins represent a good thermal path to the LM73 die, the LM73 will provide an accurate measurement of the temperature of the printed circuit board on which it is mounted. There is a less efficient thermal path between the plastic package and the LM73 die. If the ambient air temperature is significantly different from the printed circuit board temperature, it will have a small effect on the measured temperature. 8.1.2 Output Considerations: Tight Accuracy, Resolution and Low Noise The LM73 is well suited for applications that require tight temperature measurement accuracy. In many applications, the low temperature error can mean better system performance and, by eliminating a system calibration step, lower production cost. With digital resolution as fine as 0.03125 C/LSB, the LM73 senses and reports very small changes in its temperature, making it ideal for applications where temperature sensitivity is important. For example, the LM73 enables the system to quickly identify the direction of temperature change, allowing the processor to take compensating action before the system reaches a critical temperature. The LM73 has very low output noise, typically 0.015C rms, which makes it ideal for applications where stable thermal compensation is a priority. For example, in a temperature-compensated oscillator application, the very small deviation in successive temperature readings translates to a stable frequency output from the oscillator. 8.2 Typical Application VDD = 2.7V to 5.5V Typical bypass 0.1 PF 3 Address (set as desired for one of three addresses) To / from processor 2-wire interface ADDR SMBDAT SMBCLK 1 6 LM73 5 ALERT To hardware shutdown 4 2 Figure 14. Digital Temperature Sensing 8.2.1 Design Requirements The LM73 requires positive supply voltage of 2.7 V to 5.5 V to be applied between +VDD and GND. For best results, bypass capacitors of 100 nF and 10 F are recommended. 20 Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 LM73 www.ti.com SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 Typical Application (continued) 8.2.2 Detailed Design Procedure The temperature resolution is programmable, allowing the host system to select the optimal configuration between sensitivity and conversion time. The LM73 can be placed in shutdown to minimize power consumption when temperature data is not required. While in shutdown, a 1-shot conversion mode allows system control of the conversion rate for ultimate flexibility. 8.2.3 Application Curve Figure 15. Typical Performance Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 21 LM73 SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 www.ti.com 9 Power Supply Recommendations In systems where there is a large amount of capacitance on the VDD node, the LM73 power supply ramp-up time can become excessively long. Slow power-supply ramp times may result in abnormal temperature readings. A linear power-on-ramp of less than 0.7 V/msec and an exponential ramp with an RC time constant of more than 1.25 msec is categorized as a slow power-supply ramp. To avoid errors, use the power up sequence described below. The software reset sequence is as follows: 1. Allow VDD to reach the specified minimum operating voltage, as specified in the Recommended Operating Conditions section. 2. Write a 1 to the Full Power Down bit, Bit 7 of the Configuration Register, and hold it high for the specified maximum conversion time for the initial default of 11-bits resolution. This ensures that a complete reset operation has occurred. See the Temperature Conversion Time specifications within the Temperature-toDigital Converter Characteristics for more details. 3. Write a 0 to the Full Power Down bit to restore the LM73 to normal mode. 10 Layout 10.1 Layout Guidelines To achieve the expected results when measuring temperature with an integrated circuit temperature sensor like the LM73, it is important to understand that the sensor measures its own die temperature. For the LM73, the best thermal path between the die and the outside world is through the LM73's pins. In the SOT-23 package, all the pins on the LM73 will have an equal effect on the die temperature. Because the pins represent a good thermal path to the LM73 die, the LM73 will provide an accurate measurement of the temperature of the printed circuit board on which it is mounted. 10.2 Layout Example R1 VDD SMBDAT GND LM73 C1 R2 VDD SMBCLK Figure 16. PBC Layout 22 Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 LM73 www.ti.com SNIS141F - OCTOBER 2005 - REVISED OCTOBER 2015 11 Device and Documentation Support 11.1 Community Resources The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use. TI E2ETM Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help solve problems with fellow engineers. Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and contact information for technical support. 11.2 Trademarks E2E is a trademark of Texas Instruments. All other trademarks are the property of their respective owners. 11.3 Electrostatic Discharge Caution These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. 11.4 Glossary SLYZ022 -- TI Glossary. This glossary lists and explains terms, acronyms, and definitions. 12 Mechanical, Packaging, and Orderable Information The following pages include mechanical, packaging, and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation. Submit Documentation Feedback Copyright (c) 2005-2015, Texas Instruments Incorporated Product Folder Links: LM73 23 PACKAGE OPTION ADDENDUM www.ti.com 28-Feb-2017 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan Lead/Ball Finish MSL Peak Temp (2) (6) (3) Op Temp (C) Device Marking (4/5) LM73CIMK-0/NOPB ACTIVE SOT-23-THIN DDC 6 1000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM -40 to 150 T730 LM73CIMK-1/NOPB ACTIVE SOT-23-THIN DDC 6 1000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM -40 to 150 T731 LM73CIMKX-0/NOPB ACTIVE SOT-23-THIN DDC 6 3000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM -40 to 150 T730 LM73CIMKX-1/NOPB ACTIVE SOT-23-THIN DDC 6 3000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM -40 to 150 T731 (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. (4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device. (5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device. (6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish value exceeds the maximum column width. Addendum-Page 1 Samples PACKAGE OPTION ADDENDUM www.ti.com 28-Feb-2017 Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. OTHER QUALIFIED VERSIONS OF LM73 : * Automotive: LM73-Q1 NOTE: Qualified Version Definitions: * Automotive - Q100 devices qualified for high-reliability automotive applications targeting zero defects Addendum-Page 2 PACKAGE MATERIALS INFORMATION www.ti.com 3-Mar-2017 TAPE AND REEL INFORMATION *All dimensions are nominal Device Package Package Pins Type Drawing SPQ Reel Reel A0 Diameter Width (mm) (mm) W1 (mm) B0 (mm) K0 (mm) P1 (mm) LM73CIMK-0/NOPB SOT23-THIN DDC 6 1000 178.0 8.4 LM73CIMK-1/NOPB SOT23-THIN DDC 6 1000 178.0 LM73CIMKX-0/NOPB SOT23-THIN DDC 6 3000 LM73CIMKX-1/NOPB SOT23-THIN DDC 6 3000 3.2 3.2 1.4 4.0 8.0 Q3 8.4 3.2 3.2 1.4 4.0 8.0 Q3 178.0 8.4 3.2 3.2 1.4 4.0 8.0 Q3 178.0 8.4 3.2 3.2 1.4 4.0 8.0 Q3 Pack Materials-Page 1 W Pin1 (mm) Quadrant PACKAGE MATERIALS INFORMATION www.ti.com 3-Mar-2017 *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) LM73CIMK-0/NOPB SOT-23-THIN DDC 6 1000 210.0 185.0 35.0 LM73CIMK-1/NOPB SOT-23-THIN DDC 6 1000 210.0 185.0 35.0 LM73CIMKX-0/NOPB SOT-23-THIN DDC 6 3000 210.0 185.0 35.0 LM73CIMKX-1/NOPB SOT-23-THIN DDC 6 3000 210.0 185.0 35.0 Pack Materials-Page 2 IMPORTANT NOTICE Texas Instruments Incorporated (TI) reserves the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. TI's published terms of sale for semiconductor products (http://www.ti.com/sc/docs/stdterms.htm) apply to the sale of packaged integrated circuit products that TI has qualified and released to market. Additional terms may apply to the use or sale of other types of TI products and services. Reproduction of significant portions of TI information in TI data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such reproduced documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyers and others who are developing systems that incorporate TI products (collectively, "Designers") understand and agree that Designers remain responsible for using their independent analysis, evaluation and judgment in designing their applications and that Designers have full and exclusive responsibility to assure the safety of Designers' applications and compliance of their applications (and of all TI products used in or for Designers' applications) with all applicable regulations, laws and other applicable requirements. Designer represents that, with respect to their applications, Designer has all the necessary expertise to create and implement safeguards that (1) anticipate dangerous consequences of failures, (2) monitor failures and their consequences, and (3) lessen the likelihood of failures that might cause harm and take appropriate actions. Designer agrees that prior to using or distributing any applications that include TI products, Designer will thoroughly test such applications and the functionality of such TI products as used in such applications. TI's provision of technical, application or other design advice, quality characterization, reliability data or other services or information, including, but not limited to, reference designs and materials relating to evaluation modules, (collectively, "TI Resources") are intended to assist designers who are developing applications that incorporate TI products; by downloading, accessing or using TI Resources in any way, Designer (individually or, if Designer is acting on behalf of a company, Designer's company) agrees to use any particular TI Resource solely for this purpose and subject to the terms of this Notice. TI's provision of TI Resources does not expand or otherwise alter TI's applicable published warranties or warranty disclaimers for TI products, and no additional obligations or liabilities arise from TI providing such TI Resources. TI reserves the right to make corrections, enhancements, improvements and other changes to its TI Resources. TI has not conducted any testing other than that specifically described in the published documentation for a particular TI Resource. Designer is authorized to use, copy and modify any individual TI Resource only in connection with the development of applications that include the TI product(s) identified in such TI Resource. NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT OF TI OR ANY THIRD PARTY IS GRANTED HEREIN, including but not limited to any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information regarding or referencing third-party products or services does not constitute a license to use such products or services, or a warranty or endorsement thereof. Use of TI Resources may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. TI RESOURCES ARE PROVIDED "AS IS" AND WITH ALL FAULTS. TI DISCLAIMS ALL OTHER WARRANTIES OR REPRESENTATIONS, EXPRESS OR IMPLIED, REGARDING RESOURCES OR USE THEREOF, INCLUDING BUT NOT LIMITED TO ACCURACY OR COMPLETENESS, TITLE, ANY EPIDEMIC FAILURE WARRANTY AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS. TI SHALL NOT BE LIABLE FOR AND SHALL NOT DEFEND OR INDEMNIFY DESIGNER AGAINST ANY CLAIM, INCLUDING BUT NOT LIMITED TO ANY INFRINGEMENT CLAIM THAT RELATES TO OR IS BASED ON ANY COMBINATION OF PRODUCTS EVEN IF DESCRIBED IN TI RESOURCES OR OTHERWISE. IN NO EVENT SHALL TI BE LIABLE FOR ANY ACTUAL, DIRECT, SPECIAL, COLLATERAL, INDIRECT, PUNITIVE, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF TI RESOURCES OR USE THEREOF, AND REGARDLESS OF WHETHER TI HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Unless TI has explicitly designated an individual product as meeting the requirements of a particular industry standard (e.g., ISO/TS 16949 and ISO 26262), TI is not responsible for any failure to meet such industry standard requirements. Where TI specifically promotes products as facilitating functional safety or as compliant with industry functional safety standards, such products are intended to help enable customers to design and create their own applications that meet applicable functional safety standards and requirements. Using products in an application does not by itself establish any safety features in the application. Designers must ensure compliance with safety-related requirements and standards applicable to their applications. Designer may not use any TI products in life-critical medical equipment unless authorized officers of the parties have executed a special contract specifically governing such use. Life-critical medical equipment is medical equipment where failure of such equipment would cause serious bodily injury or death (e.g., life support, pacemakers, defibrillators, heart pumps, neurostimulators, and implantables). Such equipment includes, without limitation, all medical devices identified by the U.S. Food and Drug Administration as Class III devices and equivalent classifications outside the U.S. TI may expressly designate certain products as completing a particular qualification (e.g., Q100, Military Grade, or Enhanced Product). Designers agree that it has the necessary expertise to select the product with the appropriate qualification designation for their applications and that proper product selection is at Designers' own risk. Designers are solely responsible for compliance with all legal and regulatory requirements in connection with such selection. Designer will fully indemnify TI and its representatives against any damages, costs, losses, and/or liabilities arising out of Designer's noncompliance with the terms and provisions of this Notice. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright (c) 2017, Texas Instruments Incorporated Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Texas Instruments: LM73CIMK-0/NOPB LM73CIMK-1/NOPB LM73CIMKX-0/NOPB LM73CIMKX-1/NOPB LM73EVAL/NOPB